• Title/Summary/Keyword: MM

Search Result 35,933, Processing Time 0.054 seconds

Detection of Delamination inside Concrete Using Ground Penetrating Radar (GPR을 이용한 콘크리트 내 공동 탐사)

  • Rhim, Hong-Chul;Lee, Soong-Jae;Woo, Sang-Kyun;Song, Young-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.177-184
    • /
    • 2003
  • A series of experimental work has been conducted to evaluate the capability of Ground Penetrating Radar (GPR) system in detecting delamination inside concrete. Three antenna at 900 MHz, 1000 MHz, and 1500 MHz frequency are used in the experiments for laboratory size specimens, and 400 MHz antenna has been used for a large size specimen. The laboratory size specimens have the dimensions of 1,000 mm (length) ${\times}$ 600 mm (width) ${\times}$ 140 mm (thickness) with a delamination of 200 mm (length) ${\times}$ 600 mm (width) ${\times}$ 140 mm (thickness). The cover depth of the delamination is varied as follows: 20 mm, 30 mm, 60 mm, and 70 mm. In all cases, the delamination has been successfully identified. The property of three frequencies was seized about detecting delamination. Also, it was shown that the image results in GPR were improved by signal processing.

한국산 해마의 서식지 보고 및 초기생활사

  • Roh, Seom;Choi, Yeong-Ung;Yoon, Yeong-Seok;Chung, Min-Min
    • Proceedings of the Korean Aquaculture Society Conference
    • /
    • 2003.10a
    • /
    • pp.56-57
    • /
    • 2003
  • 실고기과(Syngnathidae)에 속하는 해마류는 5300만년전부터 지구상에 존재해온 어류로 전 세계적으로 72%에 해당하는 32종이 인도-태평양연안에서 서식하는 것으로 알려져 있다. 그리고 약제와 관상무역에서 넓은 시장을 형성하며 그 수요가 지속적으로 증가하고 있다. 그러나, 국내에서는 아직 해마의 서식지와 초기생활사에 대한 연구가 전무한 실정으로 이번 연구에서는 최근 발견된 한국산 해마의 서식지와 채집된 2종 해마의 치어 초기생활사를 보고한다. 2003년 8~9월에 전라남도 여수시와 고흥군 주변해역에서 해마, Hippocampus coronatus 18마리(전장 40.8~79.5mm), 산호해마 H, japonicus 80마리(전장 28.1~56.3mm)가 채집되었고, 순환여과식 사육수조에서 사육하면서 자연산란한 치어를 대상으로 초기생활사를 관찰하였다. 사육은 유리로 된 사각수조(50$\times$30$\times$28cm)에 여과조(26$\times$26$\times$28cm)를 연결한 순환여과시스템에서 실시하였으며, 사육수온은 26.0$\pm$0.5$^{\circ}C$, 염분 32$\textperthousand$ 전후, pH 7.74 전후 그리고 DO 6.8mg/$\ell$ 전후였다. 먹이는 부화 2일령까지는 로티퍼, Brachionus rotundiformis를 단독 급이하였고, 부화 후 3일령부터는 로티퍼와 알테미아, Artemia sp.를 혼합 급이하였다. 치어의 성장 측정은 만능투영기를 이용하여 각 20마리를 무작위 추출하여 측정하였고 각 측정 부위별로 0.001mm까지 측정하였다. 이번 조사에서 전라남도 여수시와 고흥군 주변해역에서 채집된 해마류는 해마(H. coronatus) 18개체, 산호해마(H. japonicus) 80개체의 2종이 채집되었고 순환여과시스템에 사육하던 중 5회 산란하였다. 해마(H. coronatus)는 부화 후 9~10일째에 Total length 11.67~15.98mm(평균 5.19mm, n=20), Trunk length 2.48~3.31mm(평균 2.63mm, n=20), Head length 1.31~2.27mm(평균 1.76mm, n=20) 그리고 Snout length 0.74~l.67mm(평균 1.09mm, n=20) 이었다. 한편, 부화 직후 산호해마(H. japonicus)의 치어는 난황을 거의 흡수한 상태였으며 부화 후 2~3일째 Total length 4.29~5.70mm(평균 5.09mm, n=30), Trunk length 2.06~2.73mm(평균 2.55mm, n=30), Head length 1.50~l.79mm(평균 1.06mm, n=30) 그리고 Snout length 0.81~l.14mm(평균 0.97mm, n=30)였다. 그리고 부화 후 5~6일째에는 Total length 4.33~6.33mm(평균 5.19mm, n=20), Trunk length로 2.48~3.31mm(평균 2.63mm, n=20), Head length 1.31~2.27mm(평균 1.76mm, n=20) 그리고 Snout length 0.74~l.67mm(평균 1.09mm, n=20) 이었다.

  • PDF

Early Osteological Development of the Larvae and Juveniles in Sebastes oblongus (Pisces: Scorpaenidae) (황점볼락(Sebastes oblongus) 자치어의 골격발달)

  • Byun, Soon-Gyu;Kang, Chung-Bae;Myoung, Jung-Goo;Cha, Ban-Seok;Han, Kyeong-Ho;Jung, Choon-Goo
    • Korean Journal of Ichthyology
    • /
    • v.24 no.2
    • /
    • pp.67-76
    • /
    • 2012
  • Skeletal development in the oblong rockfish, Sebastes oblongus, was studied based on extensive larval rearing conditions from December 2007 to March 2008. Newly-hatched larvae lacked osteological elements. After 3 days of bearing, jaw bones were ossified almost simultaneously with the frontal, parietal, clavicle, opercle, preopercle and branchiostegal rays at 8.0 mm average total length (TL). Ossification of the opercular was completed by 12.3 mm and the full complement of ossified elements of cranium and pectoral girdle were completed by 16.2 mm. Ossification of the cartilaginous caudal complex began to at 9.8 mm, and completely ossified by 18.0 mm. The fusing of the first and second, and the third and fourth hypurals initially occurred by 10.8 mm, and their fusion was finally completed at 18.0 mm. Notochord flexion occurred and formed an individual centrum by 8.5 mm and 10.8 mm, respectively, and all 26 centra were ossified by 13.2 mm. The preorbital bone began to ossify on the anterior region of eye at 10.8 mm, and the $1^{st}$ suborbital bone appeared ossified on the lower of eye by 12.3 mm, and all elements were ossified at 27.5 mm. Finally, after 71 days of bearing, the juveniles became 27.5 mm, and ossification was completed at this stage.

Osteological Development of the Larvae and Juvenile in Konosirus punctatus (전어(Konosirus punctatus) 자치어 발육단계에 따른 골격발달과정)

  • Ji-Hoon Seo;KwanSeok Kim;Jin Lee;Won-Jun Choi;Sang-Hun Cha;Tae-Sik Yu;Sung-Hun Lee;Kyeong-Ho Han
    • Korean Journal of Ichthyology
    • /
    • v.35 no.2
    • /
    • pp.83-90
    • /
    • 2023
  • Five days after hatching in Konosirus punctatus, the larvae were 5.86~6.21 mm (mean 5.96 mm) in TL and ossified parasphenoid, prefrontal, premaxillary, dentary. Sixteen days after hatching, the larvae were 9.66~10.18 mm (mean 9.96 mm) in TL and ossified prootic, opisthotic, ectopterygoid, and epihyal. Twenty-five days after hatching, the larvae were 11.02~12.64 mm (mean 11.03 mm) in TL and ossified supraclavicle, posttemporal, four actinost. Twenty-eight days after hatching, the larvae were 11.98~12.81 mm (mean 12.34 mm) in TL and ossified frontal, pterotic, epiotic, exoccipital, basioccipital, preorbital, maxillary, hyomadibular, preopercle, opercle, hypohyal. Thirty-six days after hatching, the larvae were 15.26~16.39 mm (mean 16.11 mm) in TL and ossified scapula. 37 days after hatching, the larvae were 15.33~16.87 mm (mean 16.25 mm) in TL and ossified ethmoid, nasal, parietal, supraoccipital, and suborbital. Forty-five days after hatching, the larvae were 20.01~21.83 mm (mean 21.14 mm) in TL, and the shoulder girdle was completed by coracoid formation. Forty-eight days after hatching, the larvae were 22.46~24.03 mm (mean 23.20 mm) in TL and ossified articular and subopercle. When the juvenile reached 27.11~34.09 mm (mean 30.11 mm) in TL (53 days after hatching) completed ossification of the cranium, vertebrae, pelvic girdle, shoulder girdle, caudal bone, and pterygiophore.

Three dimensional finite element method for stress distribution on the length and diameter of orthodontic miniscrew and cortical bone thickness (교정용 미니스크류 식립 시 스크류의 길이, 직경 및 피질골 두께에 따른 응력 분포에 관한 3차원 유한요소법적 연구)

  • Lim, Jong-Won;Kim, Wang-Sik;Kim, Il-Kyu;Son, Choong-Yul;Byun, Hyo-In
    • The korean journal of orthodontics
    • /
    • v.33 no.1 s.96
    • /
    • pp.11-20
    • /
    • 2003
  • The purpose of the present study is to evaluate the stress distribution on the length and diameter of the miniscrew and cortical bone width. Three dimensional finite element models were made of diameter 1.2mm, 1.6mm, 2.0mm and length 6.0mm, 8.0mm, 10.0mm, 12.0mm and cortical bone width 1.0mm. Also, another three dimensional finite element models were made of diameter 1.2mm, 1.6mm, 2.0mm and length 8.0mm and cortical bone width 1.0mm, 1.5mm, 2.0mm, 2.5mm. Two-hundred grams horizontal force were applied on the center of the miniscrew head and at that stress distribution and its magnitude had been analyzed by ANSYS, which is three dimensional finite element analysis program. The obtained results were as follows : 1. The comparison of the maximum von-Mises stress in the miniscrew showed that as the diameter increases from 1.2mm to 2.0mm stress has been decreased, while on the same diameter stress was not changed regardless of the length change. 2. The comparison of the maximum von-Mises stress in the cortical and cancellous bone showed that as the diameter increases from 1.2mm to 2.0mm stress has been decreased, while on the same diameter stress was not changed regardless of the length change. 3. In the analysis of the stress distribution in the cortical and cancellous bone, the most of the stress had been absorbed in the cortical bone, and did not transmitted much to the cancellous bone. 4. In the analysis of the maximum von-Mises stress according to the cortical bone width, the same diameter of the miniscrew showed a constant stress value regardless of the cortical bone width change. The above results suggest that the maintenance of the miniscrew is more reliable on diameter than length of the miniscrew.

Investigation of the Distance from One Tooth Center to Adjacent Tooth Center and Dental Arch Size to Develope New Removable Die System for Fabrication of Dental Prosthetic Appliance (치과보철물 제조용 모형 조립체(가철식 치형 시스템) 개발을 위한 인접 치아 중심 간격 및 악궁 크기 조사)

  • Kim, Bu-Sob;Ma, Seung-Ho;Jeong, Kyung-Mok;Byun, Tae-Hee
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.151-161
    • /
    • 2007
  • To obtain the information of dental arch size and the distance from one tooth center to adjacent tooth center of occlusal surface of each tooth which is perforated by Pindex system on working cast for removable die system, 600 dental casts in Busan were examined. The distance of center of occlusal surface of each tooth and dental arch size were digitized. The results were as follows; 1. Mean values of the distance from center of maxillary central incisor to maxillary lateral incisor(tooth number 11$\sim$12, 21$\sim$22) is 5,7 mm, 12$\sim$13(22$\sim$23) is 5.9 mm, 13$\sim$14(23$\sim$24) is 6.9 mm, 14$\sim$15(24$\sim$25) is 7.1 mm, 15$\sim$16(25$\sim$26) is 8.4 mm, 16$\sim$17(26$\sim$27) is 10.2 mm, 11$\sim$21 is 7.30 mm. Mean values of the distance from center of mandibular central incisor to mandibular lateral incisor(tooth number 31$\sim$32, 41$\sim$42) is 4.5 mm, 32$\sim$33(42$\sim$43) is 4.8 mm, 33$\sim$34(43$\sim$44) is 6.3 mm, 34$\sim$35(44$\sim$45) is 7.2 mm, 35$\sim$36(45$\sim$46) is 9.2 mm, 36$\sim$37(46$\sim$47) is 10.7 mm, 31$\sim$41 is 4.7 mm. 2. Mean values of the distance from the center of maxillary right central incisor to the center of maxillary left central incisor(11$\sim$21) is 7.3 mm, 12$\sim$22 is 18.2 mm, 13$\sim$23 is 26.9 mm, 14$\sim$24 is 37.2 mm, 15$\sim$25 is 43.2 mm, 16$\sim$26 is 48.5 mm, 17$\sim$27 is 53.5 mm. Mean values of the distance from the center of mandibular right central incisor to the center of mandibular left central incisor(31$\sim$41) is 4.7 mm, 32$\sim$42 is 13.3 mm, 33$\sim$43 is 21.7 mm, 34$\sim$44 is 31.9 mm, 35$\sim$45 is 38.2 mm, 36$\sim$46 is 44.8 mm, 37$\sim$47 is 50.7 mm. 3. Mean values of the distance from the line of between 11$\sim$21 to 12$\sim$22 is 10.9 mm, 12$\sim$22 to 13$\sim$23 is 8.7 mm, 13$\sim$23 to 14$\sim$24 is 10.3 mm, 14$\sim$24 to 15$\sim$25 is 6.0 mm, 15$\sim$25 to 16$\sim$26 is 5.3 mm, 16$\sim$26 to 17$\sim$27 is 5.0 mm. 31$\sim$41 to 32$\sim$42 is 8.6 mm, 32$\sim$42 to 33$\sim$43 is 8.4 mm, 33$\sim$43 to 34$\sim$44 is 10.2 mm, 34$\sim$44 to 35$\sim$45 is 6.3 mm, 35$\sim$45 to 36$\sim$46 is 6.6 mm, 36$\sim$46 to 37$\sim$47 is 5.9 mm. 4. We checked the bottom side of cast to verify the position of dowel pin. There is no difference upper side and lower side.

  • PDF

A Study on the Regional Property for the Agricultural Water Demand (농업용수 수요량의 지역적 특성 조사 연구(관개배수 \circled1))

  • 김선주;이광야;여운식;박재흥
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.120-125
    • /
    • 2000
  • This study analyzes agricultural water demand nationwide which calculated by the estimation system for agricultural water demand(ESAD) with the data are observed in the other Studies. The results are as follows. Maximum, minimum and average values of annual evapotranspiration in paddy in 1,767 boundaries covering all the country are estimated as 819.2mm, 595.2mm and 702.9mm respectively. In the case of transplant seeding, the annual effective rainfall is estimated as 834.7mm to 464.3mm, while the average is 635.3mm. The amount of effective rainfall is largest in case of transplant seedlings and then come watered direct seeding and dry direct seeding regardless of region. Maximum, minimum and average values of annual evapotranspiration in upland in 1,767 boundaries are estimated as 659.97mm, 129.3mm and 411.8mm respectively. The annual effective rainfall is estimated as 607.2mm to 68.3mm while the average is 257.4mm. infiltration ratio in paddy in 1,767 boundaries applied in ESAD is 5.06mm/day in average, varying from 12.0mm/day to 2.0mm/day. Applied conveyance loss is 12.8% in average, varying from 18.0% to 8.0%.

  • PDF

A STUDY OF INTRAORAL ANATOMIC LANDMARKS OF KOREAN ADULT-UPPER JAW (성인 유치악자 상악골의 악궁과 치열궁의 형태에 관한 조사)

  • Oh, Yu-Ree;Lee, Sung-Bok;Park, Nam-Soo;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.753-768
    • /
    • 1995
  • For accurate impression taking of dental patient and esthetic denture treatment of ednetulous patient, measuring between intraoral anatomic landmarks is useful.In this study the subjects selected at a random were two-jundred forty persons with a mean age 22.5(range 21-24) and were taken impression of by irreversible hydrocolloid impression material(Alginate). On the study model made by dental stone, each individual tray was made and final impresion was taken by border moilding. On final model measurings were performed with 3-dimensional measuring device and the values were analyzed by t-test The results is following : ABOUT THE MEASURED VALUES. 1. The width between maxillary right and left canine cusp tip was average 36.44mm(s.d. 2.48), man 36.67mm, woman 35.83mm(p<0.05). 2. The width between labial height of contour of maxillary right and left canine was average 40.08mm(s.d. 2.42), man 40.29mm, woman 39.52mm(p<0.05). 3. The width between mesio-lingual cusps of maxillary first molar was average 43.14mm(s.d. 3.33), man 43.56mm, woman 42.05mm(p<0.05). 4. The width between buccal alveolar ridge on axis of mesiolingual cusp of right and left maxillary first molar was average 64.89mm(s.d. 3.88), man 65.58mm, woman 62.92mm(p<0.05). 5. The width between buccal alveolar ridge on axis of mesiolingual cusp of right and left maxillary second molar was average 68.58mm(s.d. 3.91), man 69.29mm, woman 66.30mm (p<0.05). 6. The width between right and left hamular notch was average 49.80mm(s.d. 3.96), man 50.70mm, woman 48.20mm(p<0.05). 7. The length from labial heigth of contour of maxillary central incisor to center of incisive papilla was average 9.52mm(s.d. 1.18), man 9.46mm, woman 9.63mm(p>0.05). 8. The length from labial heigth of contour of maxillary central incisor to palatine fovea was average 53.27mm(s.d. 2.93), man 53.93mm, woman 52.08mm(p<0.05). 9. The center of incisive papilla ws located posterior to intercanine line at 0.40mm(s.d. 1.16), man 0.51mm, woman 0.11mm(p<0.05). 10. The height from incisal edge of maxillary central incisor to the labial vestibule was average 21.84mm(s.d. 1.38), man 22.01mm, woman 21.00mm(p<0.05). 11. The height from mesiolingual cusp of maxillary first molar to buccalvestible was average 17.45mm(s.d. 1.42), man 17.56mm, woman 17.08mm(p>0.05). 12. The height from hamular notch to standard occlusal plane was average 6.84mm(s.d. 1.06), man 6.91mm, woman 6.70mm(p>0.05). 13. The height from the deepest point of palatal vault to standard occlsalplane was average 19.95 mm(s.d. 2.03), man 20.19mm, woman 19.12mm(p<0.05). ABOUT THE ARCH FORM 1. The arch form was able to classify into four typr by the rate of the measured values. Each arch form distribution was that the 1 group had 32.46% the 2 group 2.19%, the 3 group 52.83%, the 4 group 12.72%. The sexual composition was that in 1 group man had 73.5%, woman 26.5%, in 2 group man had 40.0%, woman 60.0%, in 3 group man had 83.3%, woman 16.7%, and in 4 group man had 55.17%, woman 44.83%. 2. When canine cusp tip was marked as point O, the intersection point between labial height of contour of maxillary central incisor and intermaxillary suture as point A, height of contour of maxillary second molar buccal alveolar ridge as B point, ${\angle}$AOB was measured $133.8^{\circ}$for the 1 group, $133.0^{\circ}$for the 2 group, $132.3^{\circ}$for the 3 group, $128.9^{\circ}$for the 4 group.

  • PDF

A Survey on the Status of Shoe-last Production for Handmade Shoes - Focused on Seongsu-dong Complex - (수제화 라스트 생산 현황 조사 - 성수동 지역을 중심으로 -)

  • Hong, Eun-Hee;Park, Myung-Ja;Jeong, Jae-Chul;Uh, Mi-Kyung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.19 no.4
    • /
    • pp.93-104
    • /
    • 2017
  • This study is a basic study to develop shoe last design technology to enhance and revitalize the competitiveness of the handmade shoes. In-depth interviews were conducted with four manufacturers in Seongsu-dong to identify the production status and design technology of shoe lasts. The result of the research is as follows. Firstly, shoe lasts for adults are produced at intervals of 5mm between 245mm-285mm for men's shoes, and between 220-260mm for women's shoes. The production rate of women's shoes was high in the order of general type, boot type, and sandal type while men's shoes mainly produce general type. Secondly, the master last size and ball girth rating for men's and women's shoes were analyzed to EE-EEE grade at 260mm and D grade at 235mm. The length of the master last for men's shoes is 276-290mm, the heel width is 60-65mm, the ball width is 88-90mm, the ball girth is 250mm, and the waist girth is 248mm. The length of the master shoe last for women's shoes is 236-245 mm, the heel width is 50-55mm, the ball width is 78-80mm, the ball girth is 211~213mm, and the waist girth is 213~215mm. Thirdly, the last grading deviation is 5mm in length, the heel width is 0.5mm, the ball girth is 3.5mm, and the ball with is 1.2mm. The ball girth dimensions of Oxford type, slip-on type, and sneakers type are made at 250mm, 248mm, and 245mm for men's shoes. For women's shoes, the ball girth dimensions of pump type, loafer & boot type, and sandal type are made at 211~213mm, 214~215mm, and 211mm. Fourthly, t+he construction of the automation system is insufficient and almost completely depends on manual production.

  • PDF

Fractionated Stereotactic Radiotherapy (FSRT) Using Gold Markers : A Comparison of the Isocenter between Multiple Arcs and Static Conformal Beams (금속표지자를 이용한 다중호형 정위방사선치료와 입체조형 정위방사선치료의 회전중심점 비교)

  • 장지영;김기환;김재성;김준상;송창준;김선환;조문준
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • The aim of the study was to assess the isocenter deviation between multiple arcs and conformal beams in frameless FSRT. Forty seven patients received single isocenter radiosurgery or therapy (SRS/T) using available framelss FSRT system from Aug. 1997 to Dec. 2m. In choosing multiple arc FSRT or conformal FSRT, we had considered one of two techniques with respect to tumor size and tumor shape. In multiple arc FSRT, the average and standard deviation (SD) of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.2 mm (SD 0.2) and 0.3 mm (SD 0.2 mm)in the lateral (x), anterior-posterior (y) and cranio-caudal directions (z). In conformal FSRT, the average deviation and SD of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.3 mm(0.2 mm) and 0.4 mm (SD 0.2 mm) in the x, y and z directions. The average spacial deviation ($\Delta$r) was 0.41 mm and 0.54 mm in multiple arcs and conformal beams, respectively. The isocenter deviation using frameless FSRT system was similar value between multiple arcs and conformal beams. In practice, we believed we can select the appropriate treatment technique according to tumor shape and size.

  • PDF