• 제목/요약/키워드: MLSS Concentration

Search Result 127, Processing Time 0.021 seconds

혐기-호기 공정을 이용한 염료페수의 생물학적 처리 (Biological Treatemnt of Dye Wastewater Using an Anaerobic-Aerobic System)

  • 박영식;문정현;안갑환
    • 한국환경과학회지
    • /
    • 제11권6호
    • /
    • pp.569-576
    • /
    • 2002
  • Anaerobic/aerobic reactor system was used to treat a synthetic wastewater with glucose as carbon sources(0.38~2.29 kg COD/m3.day) and Acid Red 14(1.05 "24.00 g Acid Red 141m3.day, color degree of 570 ~ 1710). COD removal efficiency by the anaerobic stage in operation period were above 90 % organic loading rate of 0.38 ~ 2.29 kg COD/m3.day(except, adaptation period) and the removal efficiency of the whole system were above 96 %. The decolorization of the Acid Red 14 was through the alteration of the dye structure(or cleavage of the Azo bond) during the anaerobic treatment. In the A/A system, the anaerobic stage played an essential role in removing both color and COD. In addition it also improves biodegradability of dye f3r further aerobic treatment. After operation, average MLSS concentration of anaerobic sludge reactor, anaerobic fixed-bed reactor and aerobic fixed-bed reactor were 17100mg/L, 20000mg/L, and 10000mg/L, respectively.

활성슬러지공정에 의한 유기인계 농약폐수처리 (A Study on Agricultural the Treatment of Organic Phosphorous Agricultural Pesticides Wastewater by the Activated Sludge Process)

  • 최택열;최규철
    • 한국환경보건학회지
    • /
    • 제21권2호
    • /
    • pp.36-41
    • /
    • 1995
  • In order to treat effectively various type of wastewater discharged from the manufacture factory of organic phosphorous agricultural pesticides by the activated sludge process. The acclimation test of sludge was carried out by the dilution of completely mixed raw wastewater. The results of experiment were obstained as follows. 1. The moderate dilution rate of mixed raw wastewater was founded to about 30 times. 2. The available range of BOD-SS loading was 0.1~0.15 $kg\cdot BOD/kg\cdot SS\cdot day$ and it was similar to the case of extended aeration activated sludge process. 3. After the acclimation of activated sludge, the concentration of MLSS was 2000 mg/L, removal efficiency of BOD more than 90%, and SVI 100, respectively. 4. The oxygen respiratory rate of acclimated sludge was $47 mg\cdot O_2/g\cdot hr$ and this was increased about 5 times than $10 mg\cdot O_2/g\cdot hr$ of ordinary sludge.

  • PDF

막오염현상이 중공사정밀여과막의 물투과특성에 미치는 영향 (Influences of Membrane Fouling on Water Permeability of Hollow Fiber Microfiltration Membrane)

  • 김부길
    • 상하수도학회지
    • /
    • 제10권3호
    • /
    • pp.92-99
    • /
    • 1996
  • The effects of membrane fouling on the water permeability were examined using the hollow fiber microfiltration (HMF)membrane. A membrane module with a pore size of 0.1 micron was submerged in the permeation tank and water bath. The applied pressure was 12.4 kPa for direct solid-liquid separation of activated sludge. As the concentration of MLSS(880~2180mg/l) of the feed solution increased, the decreasing rates of the water flux increased and the membrane was clogged more rapidly. The water flux through the membrane did not increase effectively even with the increase in the applied pressure(40.0~93.3kPa). When the membrane was cleaned with water, the recovery rate of water flux were larger for lower applied pressure. The results indicated that the process of direct solid-liquid separation using HMF membrane was effective at lower pressure.

  • PDF

침지형 membrane을 이용한 생활오수처리 (Municipal Wastewater Treatment by Submerged Membrane Process)

  • 김광남;정순형;정우영;윤용수
    • 환경위생공학
    • /
    • 제14권2호
    • /
    • pp.105-112
    • /
    • 1999
  • The removal characteristic of BOD, COD,T-N, and T-P was investigated in municipal wastewater treatment with anoxic and membrane submerged aerobic reactor. It was found that BOD and COD removal rate were obtained 90% and 92%, respectively, for 90 days operation. BOD and COD loading rate did not affect to the removal efficiency because MLSS concentration in aerobic tank was highly maintained.In the case of first reactor operated with anoxic and second reactor operated as aerobic, T-N, T-P removal rate were obtained 93% and 99% respectively.It was shown that removal efficiency could be maintained stable due to the complete removal of SS and sludge production decreased with increasing of sludge retention time.

  • PDF

연속회분식 반응기를 이용한 수산물 가공폐수 처리 (Treatment of Fish Processing Wastewater Using Sequencing Batch Reactor (SBR))

  • 백병천;신항식
    • 상하수도학회지
    • /
    • 제8권1호
    • /
    • pp.18-26
    • /
    • 1994
  • This research investigated efficient operation mode for the successful performance of SBR(sequencing batch reactor) treating fish processing wastewater, and the effect of sodium chloride (NaCl) on treatment efficiency. 2-hour-annerobic, 6-hour-aerobic and 3-hour-anoxic operation during reaction period was found an effective operating method for organic and nitrogen removal from fish processing wastewater in SBR system. The average removal efficiencies of COD, BOD, and total nitrogen in SBR operated continuousely were 91%, 95%, and 67.1%, respectively. The estimated values of biomass yield coefficient(Y), microbial decay coefficient($K_d$), and bioreaction rate constant(K) were $0.35gMLSS/gCOD_{removed}$, $0.015day^{-1}$, and $0.209hr^{-1}$, respectively. As NaCl concentration increased from 5 to 30g/L, sludge settleability was cnhanced but organic removal in the reactor was decreased. NaCl of influent had considerable relationship with COD removal, whereas it did not significant affect nitrogen removal.

  • PDF

SMBR을 이용한 음식폐수의 고도처리 (Application of SMBR process in food wastewater advanced treatment)

  • 윤용수;강광남;정순형
    • 환경위생공학
    • /
    • 제16권1호
    • /
    • pp.34-39
    • /
    • 2001
  • Submerged Membrane Bio-Reacter(SMBR) process was used to food wastewater treatment. From laboratory pilot-scale experiment data, it was confirmed that this process was very effective process for organics, suspended solid, and N, P treatment. It was found that BOD and COD removal rate were obtained 90% and 92%, respectively, for 150 days operation. Organics loading rate did not affect to the removal efficiency because MLSS concentration in aerobic tank was highly maintained. IN the case of first reactor operated with anoxic and second reactor operated as aerobic, T-N, T-P removal rate were obtained 93% and 95%, respectively. It was shown that removal efficiency could be maintained stable due to the complete removal of SS and sludge production decreased with increasing of sludge retention time.

  • PDF

SBR에서 호기성 입상슬러지의 형성 (Shape and Formation of Aerobic Granulation in SBR)

  • 윤주환;장희란;한종훈;한혜정
    • 한국물환경학회지
    • /
    • 제20권5호
    • /
    • pp.534-538
    • /
    • 2004
  • Granulation characteristics have been studied with an aerobic sequencing batch reactor(SBR). Organic loading of 2.46kg COD/$m^3$/day followed by 4.14kg COD/$m^3$/day had been applied to the lab-scale SBR with a very short settling time during the operating cycle. The granulation proceeded to the diameter range of 3 to 5 mm with MLSS concentration of 12,000mg/L at 45th days of operation while COD removal efficiency remained almost consistent after the granule formation. It has been noticed that aerobic granulation under the higher loading with a very short settling time seemed to be due to the microbial selection of better flocculating species.

장기폭기식 마을배수처리에서 간헐폭기 및 DO제어에 의한 질소제거 및 에너지 절약(지역환경 \circled3) (Energy Saving and Nitrogen Removal by DO Control and Intermittent Aeration Using Extended Aeration System)

  • 김형중;김선주;단헌이
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.599-604
    • /
    • 2000
  • A laboratory scale extended aeration system was installed to study the effects of DO control and intermittent aeration on energy saving and nitrogen removal. The sensors of pH, DO, ORP, MLSS, and WT were installed in the aerator to monitor them and automatically control DO concentration as 2 mg/$\ell$. In the conditions showing nitrate knee on the ORP curves, nitrogen removal rates were kept over 91%. A 72.4 % of energy saving was achieved by intermittent aeration comparing with continuous aeration.

  • PDF

교차흐름 막결합형 생물반응기에서의 막오염 연구 (Study of membrane fouling in the crossflow MBR system)

  • 최중구;김인철;최남석;홍서표;탁태문
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 추계 총회 및 학술발표회
    • /
    • pp.150-152
    • /
    • 1998
  • Now the lack of water is serious problem all over the world because of the growth of population and expansion of industrial activities. So wastewater recycle and reuse is essential in many countries. One of the most popular wastewater treatment processes is conventional activated sludge system. In spite of significant degree of treatment rate the biological process has some operational difficulties and capital disadvantages. In conventional activated sludge process, sludge settling condition is getting worse in case of sludge bulking, it is common that overall process fails due to wash-out of biomass causing low concentration of MLSS in the aeration tank. Because of the absence of claifier the membrane bioreactor(MBR) process is less affected by such problems.

  • PDF

Sludge Returned CMAS에 의한 전기부속품제조공장 폐수처리

  • 김남천;이시진
    • 한국미생물·생명공학회지
    • /
    • 제25권4호
    • /
    • pp.427-433
    • /
    • 1997
  • Sludge Returned CMAS process was applied to treat the wastewater from electric accessory manufacturing company while this type of wastewater was usually treated by chemical process. This result show that the removal rate of TCOD was about 70-80% regardless of hydraulic retention time, On the contrary, the removal rate of BOD was abtained in a range of 77-92% depending on hydraulic retention time. In order to remove more than 80% of organic materials with the proposed process, the F/M ratio should be maintained below 0.17. In this case, the calculated value of organic removal rate, Km, was calculated to be 1.26 hr$^{-1}$, and the ratio of cell synthesis/total energy was 0.32 and 0.26 for COD and BOD base, respectively. The yield coefficient was calculated to be 0.242 and the half velocity coefficient was 0.3 hr$^{-1}$. The value of endogenous respiration coefficient was 0.02 hr$^{-1}$. The measured effluent BOD concentration, MLSS concentration in aeration tank, oxygen uptake rate, and sludge production were matched relatively well with the calculated values using above coefficients, In order to optimize the dewatering of sludge, the hydraulic retention time was recommended to be 15. 6 hrs. These results indicate that the wastewater from an eletric accessory manufacturing company can be treated safely with a biological process.