• 제목/요약/키워드: MLSS Concentration

검색결과 127건 처리시간 0.026초

오존을 이용한 도시하수슬러지의 처리 (Treatment of Municipal Sewage Sludge by Ozonization)

  • 윤용수
    • 환경위생공학
    • /
    • 제17권3호
    • /
    • pp.83-88
    • /
    • 2002
  • This study was performed to determine the possibility of sludge treatment by ozone for reducing the sludge production in sewage treatment. To evaluate the characteristics of the release of organic matters and nutrient from sludge degradation by ozone, SCOD, SBOD/TCOD, T-N and T-P were analyzed. From the results, we concluded that the concentration of soluble organic matters(SCOD) was increased with reaction time. Also, The concentration of T-N and T-P were increased with time like as organic matters. Quantities of released SCOD, SBOD, T-N and T-P by ozonization were 0.038g, 0.058 g, 0.011 g, 0.012 g per g MLSS, respectively.

생물학적 고도처리공법에 적용된 두 형태의 장방형 이차침전지 성능 파악 (Evaluating Two Types of Rectangular Secondary Clarifier Performance at Biological Nutrient Removal Facilities)

  • 이병희
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.561-570
    • /
    • 2013
  • There are two types of rectangular secondary clarifier at biological nutrient removal (BNR) facility to settle MLSS; conventional activated sludge secondary clarifier and Gould Type I clarifier. In this study, the performances of two types at respective biological nutrient removal facility are compared using weekly operational data. Surface Overflow Rate (SOR), Surface Loading Rate (SLR), Sludge Volume Index (SVI), secondary effluent SS concentration are studied. It has found that Gould Type I has 3.5 times less average secondary effluent SS concentration that is 2.4 mg/L than that of conventional activated sludge secondary clarifier. Both SOR and SLR have shown little effect on secondary effluent SS concentrations at Gould Type I clarifier in contrary that SOR affects the secondary effluent SS concentrations at conventional activated sludge rectangular secondary clarifier. From this study, it is recommended that Gould Type I must be considered for secondary clarifier when BNR plant is designed.

하수재이용시설 농축수가 하수처리장 생물반응조 운영에 미치는 영향 (Effects of Membrane Filtration Concentrate of Sewage Reuse Facility on Performance of Bioreactor in Sewage Treatment Facility)

  • 임지영;김현식;배민수;김진한
    • 유기물자원화
    • /
    • 제26권3호
    • /
    • pp.5-14
    • /
    • 2018
  • 하수재이용시설 막여과 농축수가 하수처리장 생물반응조 미생물에 미치는 영향을 알아보기 위하여 기 운영 중인 하수재이용시설 농축수를 채취 분석하고 농축수 주입에 따른 산소섭취율 변화 및 연속식 활성슬러지 실험을 수행하였다. 기 운영 중인 하수재이용시설 농축수를 분석한 결과 농축수의 유기물과 T-P 농도는 SS 농도와 밀접한 관계가 있고 농축수 내의 이온성 물질은 $Cl^-$ > $Na^+$ > $Ca^{2+}$ > $K^+$ > $Mg^{2+}$ > $F^-$순으로 높게 나타났으며 농축수의 항목별 분석값은 농축수 채취시기에 따라 크게 변함을 알 수 있었다. 농축수 비율에 따른 미생물 산소섭취율(OUR) 실험을 실시한 결과 농축수 비율이 증가함에 따라 농축수가 활성슬러지 미생물에 유기물로 작용하여 산소섭취율이 증가함을 알 수 있었으며 OUR 실험만으로는 독성영향을 주는 농축수 비율을 산정할 수 없었다. 연속 활성슬러지 실험을 실시한 결과 농축수 주입비율이 증가함에 따라 MLSS 농도, 유기물 제거효율 그리고 T-N 제거효율은 서서히 감소하였다. 따라서, 실험결과 농축수가 활성슬러지의 처리효율에 영향을 주기 시작하는 주입비율은 25% 이상인 것으로 판단된다.

Treatment of High Concentration Organic Wastewater with a Sequencing Batch Reactor (SBR) Process Combined with Electro-flotation as a Solids-liquid Separation Method

  • Choi, Younggyun;Park, Minjeong;Park, Mincheol;Kim, Sunghong
    • Environmental Engineering Research
    • /
    • 제19권4호
    • /
    • pp.395-399
    • /
    • 2014
  • Operation characteristics of the sequencing batch reactor (SBR) process with electro-flotation (EF) as a solid liquid separation method (EF-SBR) were investigated. EF-SBR process showed excellent solid-liquid separation performance which enabled to separate biosolids from liquid phase within 30 min and to extend cyclic reaction time. Although influent organic loading rate was increased stepwise from 5 to 15 g COD/day, food to microorganisms (F/M) ratio could be maintained about 0.3 g COD/g VSS/day in EF-SBR because biomass concentration could be easily controlled at desired level by EF. However, it was impossible to increase biomass concentration at the same level in control SBR (C-SBR) process because solid-liquid separation by gravity settling showed a limitation at higher mixed liquor suspended solids (MLSS) concentration with 60 min of settling time. Total chemical oxygen demand (TCOD) removal efficiency of EF-SBR process was not decreased although influent organic loading rate became 3 times higher than initial value. However, it was seriously deteriorated in C-SBR process after increasing the rate over 10 g COD/day, which was accounted for insufficient organic removal by relatively higher food to microorganisms (F/M) ratio as well as biosolids wash-out by a limitation of gravity sedimentation.

컴퓨터 시뮬레이션을 이용한 최적 이차침전지 형상 파악 (Defining optimum configuration for secondary clarifier using computer simulation)

  • 이병희
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.219-230
    • /
    • 2010
  • Computer simulation has been widely used to design and optimize the operation of wastewater treatment plants since 1980. For secondary clarifiers, the simulation has been a tool to optimize the performance by providing dimensions for flocculation well. However, there has been no attempt to find the optimized geometrical parameters in circular secondary clarifier using simulation tools. In this study, three SVIs (Sludge Volume Indexes), two well types (feed and flocculation wells), 8 SWDs (Side Water Depths) and 9 bottom slopes were variables for simulation. Diurnal inflow and associated MLSS (Mixed Liquor Suspended Solid) concentrations were used for input loadings. When flocculation well was installed, 48% less concentration at lowest ESS (Effluent Suspended Solid) concentrations was produced and the diurnal ESS concentration range had been reduced by 52%. From these results, flocculation well must be installed to produce lower and stable ESS from circular secondary clarifiers. Under same loading conditions with $300m{\ell}$/g of SVI, The lowest ESS was produced when SWD was 4.5m with 4% of bottom slope. Therefore, SWD and bottom slope must not be deeper than 4.5m and must be near 4%, respectively, in circular clarifier with flocculation well to produce the lowest ESS concentration.

기상조건이 하수발생량 및 하수처리장 운전인자에 미치는 영향에 관한 통계적 분석 (Study on the Relationship between Weather Conditions, Sewage and Operational Variables of WWTPs using Multivariate Statistical Methods)

  • 이재현
    • 한국물환경학회지
    • /
    • 제28권2호
    • /
    • pp.285-291
    • /
    • 2012
  • Generally, the rainfall and the influent of wastewater treatment plants (WWTPs) have strong relationship at the case of combined sewers. With the fact that the influent variations in terms of quantity and sewage quality is the most common and significant disturbance, the impact factor to the characteristics of sewage should be searched for. In this paper, the relationship between weather conditions such as humidity, temperature and rainfall and influent flowrate and contaminant concentration was analysed using factor analysis. Additionally, 3 influent types were deduced using cluster analysis and the distributions of operational variables were compared to the each groups by one-way ANOVA. The applied dataset were clustered to three groups that have the similar weather and influent conditions. These different conditions can cause the different operating conditions at WWTPs. That is, the Group 1 is for the condition with high humidity and rainfall, so DO concentration in the reactor was very high but MLSS concentration was very low because of too large flowrate. However, the Group 3 is classified to the case having low humidity, temperature, and rainfall, therefore, the SRT was the longest and the SVI was the highest due to the worst settleability in the winter for a year.

침지식 평막 MBR 내 응집제 투여에 따른 사인파형 연속투과 운전 방식의 막간차압 (Transmembrane Pressure of the Sinusoidal Flux Continuous Operation Mode for the Submerged Flat-sheet Membrane Bioreactor in Coagulant Dosage)

  • 원인혜;김대천;정건용
    • 멤브레인
    • /
    • 제25권1호
    • /
    • pp.7-14
    • /
    • 2015
  • 본 연구에서는 MBR 내에 침지된 분리막 오염을 평가하기 위하여 운전시간에 따른 막간차압(TMP)을 측정하였다. 유효 막면적이 $0.02m^2$이고 공칭 세공크기가 $0.15{\mu}m$인 정밀여과용 평막 모듈을 MLSS 5,000 mg/L인 활성슬러지 용액에 침지시켰다. 운전/휴직(R/S) 및 사인파형 투과유속 연속운전(SFCO) 방식에 따른 TMP를 비교하기 위하여 동시에 투과 실험을 수행하였다. SFCO 운전방법에 따른 TMP는 R/S에 비하여 최대 93% 낮게 유지되었으며 투과유속이 증가함에 따라서 TMP 감소 효과는 줄어들었다. 또한 응집제인 $FeCl_3$를 활성슬러지 용액에 500 mg/L 농도로 주입시키면 SCFO 운전방식의 경우, 투과 운전시간을 5배 이상 증가시켜도 한계 운전 TMP인 55 kPa의 40% 미만으로 유지됨을 확인할 수 있었다.

활성슬러지 공정에 의한 Kraft 펄프 폐수의 독성 제거 (Removal of Toxicity from Kraft Pulp Mill Effluents by Activated Sludge Process)

  • 김영관
    • 상하수도학회지
    • /
    • 제8권3호
    • /
    • pp.9-18
    • /
    • 1994
  • 활성슬러지 공정을 이용하여 Kraft 펄프공장에서 배출되는 유출수에 잔류하는 만성독성의 제거가능성을 평가하기 위하여 pilot plant를 운전하였다. 독성 이외에도 폐수내의 BOD, SS, resin과 fatty acids, 색도, 그리고 AOX와 같은 오염물질의 제거효과도 측정되었다. Pilot plant는 정상상태에서 약 10주 동안 운전되었으며 운전기간 동안의 평균 F/M 비율은 0.28, 그리고 sludge age는 8.4일로 계산되었다. 평균 MLSS 농도는 4,309mg/l이었으며 이중 휘발성 물질은 57%이었다. 운전기간 동안, BOD 제거계수(k)는 $30^{\circ}C$에서 8.2/일 이었으며 BOD 제거율은 full-scale 운전시보다 3~6% 정도 낮은 84%로 나타났다. 활성슬러지 유출수의 만성독성 시험은 Dinnel 방법과 BML 방법이 활용되었으며, 시험결과 pilot plant 활성슬러지 시스템에서도 효율적인 운전을 통하여 90% 이상의 독성제거가 가능함을 알 수 있었다. Pilot plant의 진 공정을 통해서 색도와 AOX의 제거는 매우 미미하였으나 resin과 fatty acids는 뛰어난 제거율을 나타내었다.

  • PDF

막결합 연속회분식 반응기를 이용한 농촌마을 하수의 고도처리 (Membrane-Coupled Sequencing Batch Reactor System for the Advanced Treatment of Rural Village Sewage)

  • 김승건;이호원
    • 멤브레인
    • /
    • 제24권1호
    • /
    • pp.20-30
    • /
    • 2014
  • C/N 비가 낮은 농촌마을 하수의 고도처리를 위하여 $0.4{\mu}m$의 세공크기를 갖고 있는 평막이 침지된 연속회분식 반응기를 사용하였다. 분말활성탄의 투입, 폭기량 및 유입 유기물 농도가 처리효율과 여과 성능에 미치는 영향을 조사하였다. 54일 이내의 조업 초기에서는 C/N 비가 증가할수록 COD, T-N 및 T-P의 제거율과 MLSS 농도는 증가하였다. 조업 89일 후의 COD, T-N 및 T-P의 제거율은 각각 97.1%, 75.0% 및 48.3%이었다. 막여과에 의해 처리수에서 SS는 검출되지 않았으며, T-P의 제거율이 낮게 나온 이유는 과잉의 슬러지를 배출하지 않았기 때문이다. 분말활성탄을 투여한 경우 조업이 진행됨에 따라 분말활성탄의 혼합강도와 충돌빈도가 증가하여 슬러지의 입자크기가 감소하였으며, 이로 인해 분말활성탄을 투여하지 않은 경우에 비해 TMP 상승이 크게 나타났다.

회분여과 방식을 통한 생물대사산물의 분자량 분포 특성 평가 (Valuation of Molecular Weight Distribution Charteristics of Soluble Microbial Products(SMP) Using the Batch Filtration Test)

  • 정태영;차기철;이영무;한상국
    • 멤브레인
    • /
    • 제12권1호
    • /
    • pp.21-27
    • /
    • 2002
  • 본 연구에서는 회분여과방식을 이용하여 부하율에 따라 생성되는 생물대사성분의 특성 및 분포를 관찰하였다. 실험에 사용된 기질은 단일 탄소인 phenol을 사용하였으며, 분자량 분포실험을 위하여 분자량이 각각 30K, 100K Dalton 및 $0.45{\mu}$ membrane filter를 이용하여 구하였다. 페놀농도가 120, 230 및 440 mg/L 일 때 비기질이용율(q)은 각각 0.639, 1.281, 1.744 (mgTOC/mg MLSS/day)로 나타났으며 Run C일 때 가장 높은 이용율을 나타냈다 . 내생단계에서 미생물의 사멸율($K_d$)는 각각 0.0536, 0.0661, 0.0749($day^1$)이며 생성계수 ($SMP_e$) 는 각각 0.006, 0.0058, 0.0057($day^1$)로 나타났다. 초기 유입된 기질이 기질분해에 의해 생성된 $SMP_s$로 분해되어지며, 시간경과에 따라 $SMP_{nd}$ 로 진행됨을 알수 있었다. 기질분해 완료 후 미생물의 내생단계에 접어들면서 $SMP_e$성분으로 전환되었다. 유입부하율에 따른 분자량 분포 측정결과는 운전시간이 경고함에 따라 점차 저분자 물질이 고분자의 난분해성 물질로 전환되었다.