• Title/Summary/Keyword: MLSS Concentration

Search Result 127, Processing Time 0.027 seconds

Effects of MLSS Concentration and Influent C/N Ratio on the Nitrogen Removal Efficiency of Alternately Intermittently Aerated Nonwoven Fabric Filter Bioreactors (교차 간헐 포기식 부직포 여과막 생물반응조에서 MLSS 농도 및 유입수 C/N 비가 질소 제거효율에 미치는 영향)

  • Jung, Kyoung-Eun;Bae, Min-Su;Lee, Jong-Ho;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.501-510
    • /
    • 2006
  • To investigate the effects of MLSS concentration and influent C/N ratio on the nitrogen removal efficiency of alternately intermittently aerated nonwoven fabric filter bioreactors, the MLSS concentrations of the reactors were maintained at approximately 5,500 mg/L, 10,000 mg/L and 15,000 mg/L, and the influent TCOD/TKN ratio was decreased gradually from 5 to 2 by adding $NH_4Cl$. The influent was prepared by diluting a food waste leachate to a TCOD concentration of about 300 mg/L. The results of the experiment showed F/M ratios less than 0.112 g TCOD/g MLSS-day, average TCOD removal efficiencies of above 95%, and an average observed microbial yield coefficient of 0.283 g MLSS/g COD removed. The nitrification efficiencies were computed to be always better than 96% except one case where the nitrification efficiency was 90.5% when the MLSS concentration and the influent TCOD/TKN ratio was 5,500 mg/L and 2, respectively. The denitrification efficiency deteriorated as the influent TCOD/TKN ratio decreased. The average denitrification efficiency at the MLSS concentration of 10,000 mg/L was 10.7% better than that at the MLSS concentration of 5,500 mg/L, and the denitrification rate improved at a rate of 2.66 mg NL as the MLSS concentration increased by 1,000 mg/L. When the MLSS concentration was 15,000 mg/L, however, the average denitrification efficiency was merely 4.6% higher compared to when the MLSS concentration was 5,500 mg/L, and the denitrification rate increased at a rate of 0.75 mg N/L per 1,000 mg/L MLSS increase. Therefore, no strict proportional relationship was found between MLSS concentration and endogenous denitrification rate. The average alkalinity consumption rate was 3.36 mg alkalinity/mg T-N removed, which is similar to the theoretical value of 3.57 mg alkalinity/mg T-N removed, but the rate increased as the influent TCOD/TKN ratio decreased.

The Effects of HRT, MLSS and DO on Nitrogen Removal Efficiency in MBR Process with Internal Baffle (내부 Baffle을 설치한 MBR 공정에서 HRT와 MLSS농도, DO농도 변화가 질소제거 효율에 미치는 영향)

  • Whang, Gye-Dae;Park, Joo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.527-537
    • /
    • 2009
  • Three sets of parallel MBRs (reactor No.1, reactor No.2, reactor No.3) maintaining an MLSS of 4,000 mg/L, 6,000 mg/L and 8,000 mg/L, respectively, were operated to investigate the effect of various HRTs and DO concentration of MBRs on the removal efficiency of organic matters and nitrogen. The HRTs were operated on 4 hr, 6 hr, 8 hr. DO concentrations were ranged 1.5~2.0 mg/L and 0.5~1.0 mg/L respectively on each HRT conditions. MBR was divided into an aerated part and non-aerated part by baffle placed under the water. DO concentrations were controlled by altering the position of baffle. In terms of TSS and CODCr, all systems had a similar level of the removal under varied HRTs and MLSS. TSS removal efficiency was more than 99% and CODCr removal was ranged 94~97% under all conditions. Under the same condition on the HRT and MLSS concentrations, DO concentrations did not affect the organic removal efficiency. On the nitrification efficiency, with high DO concentration, as HRT or MLSS increased, the slight increment of nitrification efficiency was observed. However, under the low DO concentration, increase of MLSS and HRT resulted in larger increase of the nitrification efficiency. At the same HRT and MLSS, the nitrification efficiency increased greatly with up to 16% as DO increased. When the HRT increased from 4hr to 8hr, the denitrification efficiency slightly increased under most of conditions. However, the increase of MLSS resulted in about 19~39% denitrification efficiency increment. MLSS concentrations showed great effect on the denitrification. The increase of the DO concentration at the same HRT and MLSS resulted in decrease of denitrification efficiency with up to 27%. In all systems, the denitrification efficiency had more influence on the TN removal efficiency than nitrification efficiency. So, MLSS concentration has greater effect on the TN removal than HRT and DO. The TN removal efficiency increased as MLSS increased with up to 37%. As a result, the highest TN removal efficiency was observed 79.0% at the condition showed the highest denitrification efficiency that DO of 0.5~1.0 mg/L, an HRT of 8 hr, and 8,000 mg/L of MLSS concentration were maintained.

Effects of Biomass Concentration and Sludge Loading Rate on Bioactivity and Membrane Fouling in a Submerged Membrane Bioreactor System (침지형 분리막 생물반응기에서 미생물 농도와 슬러지 부하에 따른 미생물 활성 변화와 막오염 특성 연구)

  • Tak Tae-Moon;Bae Tae-Hyun;Jang Gyoung-Gug
    • Membrane Journal
    • /
    • v.14 no.4
    • /
    • pp.289-297
    • /
    • 2004
  • In this study, membranes were coupled to a sequencing batch reactor for simultaneous removal of organic matter and nitrogen, and the influences of MLSS (mixed liquor suspended solid) concentration and the sludge loading rate on membrane fouling and bioactivity were investigated. The amount of membrane fouling slightly increased with MLSS concentration at both non-aeration and aeration conditions, but effect of MLSS concentration was more significant at aeration condition. Although the effect of MLSS concentration on membrane fouling was found to be insignificant at low concentration level, extremely low sludge loading, which were generated by the maintenance of large amount of biomass in the reactor, caused severe membrane fouling, and air scouring effect decreased significantly in this condition. Specific bioactivity was constantly reduced as sludge loading rate decreased. In spite of high MLSS concentration over 17,000 mg/L, the activity of the reactor decreased at extremely low sludge loading rate presumably due to the lower oxygen transfer and the competition of biomass to deficient substrate.

Modeling of the effect of current density and contact time on membrane fouling reduction in EC-MBR at different MLSS concentration (EC-MBR 공정의 MLSS, 전류밀도 및 접촉시간이 막 오염 감소에 미치는 영향 모델링)

  • Kim, Wan-Kyu;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.111-119
    • /
    • 2019
  • Electro-coagulation process has been gained an attention recently because it could overcome the membrane fouling problems in MBR(Membrane bio-reactor). Effect of the key operational parameters in electro-coagulation, current density(${\rho}_i$) and contact time(t) on membrane fouling reduction was investigated in this study. A kinetic model for ${\rho}_i$ and t required to reduce the membrane fouling was suggested under different MLSS(mixed liquor suspended solids) concentration. Total 48 batch type experiments of electro-coagulations under different sets of current densities(2.5, 6, 12 and $24A/m^2$), contact times(0, 2, 6 and 12 hr) and MLSS concentration(4500, 6500 and 8500mg/L) were carried out. After each electro-coagulation under different conditions, a series of membrane filtration was performed to get information on how much of membrane fouling was reduced. The membrane fouling decreased as the ${\rho}_i$ and t increased but as MLSS decreased. Total fouling resistances, Rt (=Rc+Rf) were calculated and compared to those of the controls (Ro), which were obtained from the experiments without electro-coagulation. A kinetic approach for the fouling reduction rate (Rt/Ro) was carried out and three equations under different MLSS concentration were suggested: i) ${\rho}_i^{0.39}t=3.5$ (MLSS=4500 mg/L), ii) ${\rho}_i^{0.46}t=7.0$ (MLSS=6500 mg/L), iii) ${\rho}_i^{0.74}t=10.5$ (MLSS=8500 mg/L). These equations state that the product of ${\rho}_i$ and t needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.

Minimization of Excess Activated Sludge in Nonwoven Fabric Filter Bioreactor (부직포 여과막 생물반응조에서의 폐활성슬러지 감량화)

  • Jung, Kyoung-Eun;Bae, Min-Su;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.88-96
    • /
    • 2006
  • Among the various methods for minimization of waste activated sludge, maintaining a low F/M ratio in the bioreactor is known to be the most effective reliable one. In this research, various experiments were performed to check the capability of the nonwoven fabric filter bioreactor, which has been proved able to maintain a low F/M ratio by maintaining a high MLSS concentration, for excess sludge minimization. The reactor was intermittently fed with a synthetic wastewater having a COD concentration of approximately 300 mg/L and no SS. Results of the experiments showed that the F/M ratio in the reactor decreased to a minimum value of 0.02 g COD/g MLSS-day as the MLSS concentration increased to a maximum value of 31,010 mg/L. However, the measured endogenous decay coefficients and oxygen uptake rates of the MLSS confirmed that the activity of the MLSS decreased as the MLSS concentration increased. Based on the increase of MLSS in the reactor and the mass balance during the whole experimental period, the average microorganism yield coefficients were computed to be low values of 0.148 and 0.139 g MLSS/g COD, respectively. These results indicate that the nonwoven fabric filter bioreactor employed in this research is effective for minimization of excess sludge production.

The design of an ejector type microbubble generator for aeration tanks

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Membrane and Water Treatment
    • /
    • v.10 no.4
    • /
    • pp.307-311
    • /
    • 2019
  • The ejector type microbubble generator, which is the method to supply air to water by using cavitation in the nozzle, does not require any air supplier so it is an effective and economical. Also, the distribution of the size of bubbles is diverse. Especially, the size of bubbles is smaller than the bubbles from a conventional air diffuser and bigger than the bubbles from a pressurized dissolution type microbubble generator so it could be applied to the aeration tank for wastewater treatment. However, the performance of the ejector type microbubble generator was affected by hydraulic pressure and MLSS(Mixed Liquor Suspended Solid) concentration so many factors should be considered to apply the generator to aeration tank. Therefore, this study was performed to verify effects of hydraulic pressure and MLSS concentration on oxygen transfer of the ejector type microbubble generator. In the tests, the quantity of sucked air in the nozzle, dissolved oxygen(DO) concentration, oxygen uptake rate(OUR), oxygen transfer coefficient were measured and calculated by using experimental results. In case of the MLSS, the experiments were performed in the condition of MLSS concentration of 0, 2,000, 4,000, 8,000 mg/L. The hydraulic pressure was considered up to $2.0mH_2O$. In the results of experiments, oxygen transfer coefficient was decreased with the increase of MLSS concentration and hydraulic pressure due to the increased viscosity and density of wastewater and decreased air flow rate. Also, by using statistical analysis, when the ejector type microbubble generator was used to supply air to wasterwater, the model equation of DO concentration was suggested to predict DO concentration in wastewater.

Influence of mixed liquor suspended solids on the removal efficiency of a hybrid membrane bioreactor

  • Palmarin, Matthew J.;Young, Stephanie
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.11-22
    • /
    • 2016
  • The characterization of treatment performance with respect to mixed liquor suspended solids (MLSS) concentration enables greater control over system performance and contaminant removal efficiency. Hybrid membrane bioreactors (HMBRs) have yet to be well characterized in this regard, particularly in the context of greywater treatment. The aim of this study, therefore, was to determine the optimal MLSS concentration for a decentralized HMBR greywater reclamation system under typical loading conditions. Treatment performance was measured at MLSS concentrations ranging from 1000 to 4000 mg/L. The treated effluent was characterized in terms of biochemical oxygen demand ($BOD_5$), chemical oxygen demand (COD), turbidity, ammonia ($NH_3$), total phosphorus (TP), total kjeldahl nitrogen (TKN), and total nitrogen (TN). An MLSS concentration ranging from 3000 to 4000 mg/L yielded optimal results, with $BOD_5$, COD, turbidity, $NH_3$, TP, TKN, and TN removals reaching 99.2%, 97.8%, 99.8%, 99.9%, 97.9%, 95.1%, and 44.8%, respectively. The corresponding food-to-microorganism ratio during these trials was approximately 0.23 to 0.28. Operation at an MLSS concentration of 1000 mg/L resulted in an irrecoverable loss of floc, and contaminant residuals exceeded typical guideline values for reuse in non-potable water applications. Therefore, it is suggested that operation at or below this threshold be avoided.

Study on Organic Matter and Nitrogen Removal by Biological Treatment of Wastewater Processing of Chicken, which is the Primary Chemical Processing (1차 화학 처리된 닭 가공 폐수의 생물학적 처리에 의한 유기물 및 질소제거에 관한 연구)

  • Han, Hyung Suk;Choi, Yong Gu;Song, Jin Ho;Kim, Ho
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.3
    • /
    • pp.247-256
    • /
    • 2014
  • A company, which is chicken butcherying-plant, was scheduled to increase up to twice output. We researched the way to increase up to twice the processing efficiency at the target biological treatment tank of A company. We performed for this study to obtain the reason why organic matter and nitrogen removal efficiency is increased when MLSS concentration is increased. It's performed at the target of pressure flotation water on SBR system. We performed the research which MLSS was 12,700 mg/L for 30hours (in aerobic condition for 25 hours and in anoxic condition for 5 hours). As a result, the nitrification was happened completely in aerobic condition within 25 hours. Denitrification efficiency was also over 90% when C/N ratio was over 3:1. After the experiment, we changed the concentration of MLSS 5,600 to 12,700 mg/L. In condition MLSS was about 11,000 mg/L and HRT were 30 hours meet the Effluent quality standard.

A Study on Efficiency of SBR Process by Composition of Artificially Wastewater (인공하수 조성 성분에 따른 SBR 처리 공정의 효율에 관한 연구)

  • Lee Jang-Hoon;Jang Seung-Cheol;Kwon Hyuk-Ku;Kim Dong Wook
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.2 s.83
    • /
    • pp.99-106
    • /
    • 2005
  • The removals of organic matter, nitrogen and phosphate in wastewater were investigated with Sequencing Batch Reactor (SBR). Glucose and sodium acetate were Used for organic carbon source so as to know nutrient removal efficiency in proportion to MLSS concentration. In the case of glucose, the COD removal rate was $74\%,\;41\%\;and\;66\%$ in MLSS 5000, 3000 and 1000, respectively. On equal terms, the BOD was $57\%,\;21\%\;and\;38\%$, the T-N was $24\%,\;13\%\;and\;44\%$, and the T-P was $12\%,\;21\%\;and\;33\%$. As a result, the removal rate of organic materials showed the finest remove when MLSS was 5000, but the nutrient removal rate appeared as was best when MLSS was 1000. In the case of sodium acetate, the COD removal rate was $83\%,\;81\%\;and\;86\%$ in MLSS 5000, 3000 and 1000, respectively. On equal terms, the BOD was appeared by $76\%,\;82\%\;and\;92\%$, the T-N $57\%,\;42\%\;and\;78\%$, and the T-P $48\%,\;52\%\;and\;38\%$. As a result, organic and T-N removal rates were best when MLSS was 1000. But, the T-P removal rates were best when MLSS was 3000. Glucose was shown fast removal in reaction beginning, but screened by more efficient thing though sodium acetate removes organic matter, nitrogen and phosphate. Form of floc was ideal in all reactors regardless of carbon source and MLSS concentration. And its diameter was about $200\~500{\mu}m$.

Characteristics of Advanced Wastewater Treatment Process Using High MLSS in Anoxic Tank (무산소조에서 고농도 미생물을 이용한 하수고도처리공정의 처리특성)

  • Son, Dong-Hun;Lim, Bong-Su;Park, Hye-Sook
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.42-47
    • /
    • 2004
  • This study was accomplished to develope an advanced wastewater treatment process using high MLSS in anoxic tank aimed to improve nutrient removal and to reduce wasting sludge. It was operated with 4 Modes with varing solid concentration and internal recycle ratios. Mode I, II, III was operated 1.0~1.5% MLSS concentration at anoxic tank with 50% sludge recycle rate, however, each internal recycle rate were 100%, 200%, 300% and Mode IV was operated 1.5~2.0% MLSS concentration at anoxic tank with 50% sludge recycle rate and 100% internal recycle rate. The COD removal efficiency didn't show any big difference from Mode I to IV. The average COD removal rate was over than 90%. The T-N removal rate was 73%, the highest rate in all mode. The 36% of SCOD is used for the denitrification and phosphorus release in the anoxic tank. Specific denitrification rate was 3.5mg $NO_3{^-}-N/g$ Mv/hr and denitrification time was 0.7hr. As MLSS concentration is higher in anoxic tank as denitrification time would be shorter. The T-P removal rate was average 70%. The phosphorus release accomplished from the anoxic tank because the anaerobic condition was prevalent in the anoxic due to the prompt completion of denitrification. Sludge production was 0.28 kgVSS/kg $BOD_{removed}$ under the 1.5% MLSS and 17 day SRT. It is prominent result which has 40% sludge reduce comparing with traditional activate sludge system.