• 제목/요약/키워드: MLA (micro lens array)

검색결과 16건 처리시간 0.018초

Combination Treatment of Nd:YAG Picosecond-domain Laser and Fractional CO2 Laser for Contracted Neck Scar with Hyperpigmentation

  • Choi, Woo Jung;Park, Eun Soo;Tak, Min Sung;Kang, Sang Gue
    • Medical Lasers
    • /
    • 제10권1호
    • /
    • pp.52-54
    • /
    • 2021
  • There is growing interest in minimizing postoperative scarring after a thyroidectomy. Among the many treatment types, laser therapy, especially picosecond-domain laser therapy, is accepted as a standard method. In the present case, a patient with a pigmented, contracted scar was treated using the combination of a picosecond laser and ablative fractional (AF) CO2 laser. After 15 sessions of 1,064-nm picosecond with micro lens array (MLA) and AF CO2 laser application, the patient showed significant improvement in their pigmented lesions and scar contracture with no noticeable side effects for 16 months. These results suggest that a combination of picosecond laser with MLA and AF CO2 laser can treat pigmented, contracted scars safely and effectively.

RIE 공정을 이용한 유기발광다이오드의 광 산란층 제작 (Fabrication of Scattering Layer for Light Extraction Efficiency of OLEDs)

  • 배은정;장은비;최근수;서가은;장승미;박영욱
    • 반도체디스플레이기술학회지
    • /
    • 제21권1호
    • /
    • pp.95-102
    • /
    • 2022
  • Since the organic light-emitting diodes (OLEDs) have been widely investigated as next-generation displays, it has been successfully commercialized as a flexible and rollable display. However, there is still wide room and demand to improve the device characteristics such as power efficiency and lifetime. To solve this issue, there has been a wide research effort, and among them, the internal and the external light extraction techniques have been attracted in this research field by its fascinating characteristic of material independence. In this study, a micro-nano composite structured external light extraction layer was demonstrated. A reactive ion etching (RIE) process was performed on the surfaces of hexagonally packed hemisphere micro-lens array (MLA) and randomly distributed sphere diffusing films to form micro-nano composite structures. Random nanostructures of different sizes were fabricated by controlling the processing time of the O2 / CHF3 plasma. The fabricated device using a micro-nano composite external light extraction layer showed 1.38X improved external quantum efficiency compared to the reference device. The results prove that the external light extraction efficiency is improved by applying the micro-nano composite structure on conventional MLA fabricated through a simple process.

자외선 차단이 가능한 유기발광다이오드의 효율 향상을 위한 친환경 아웃 커플링 필름 (Environmental Friendly Out-Coupling Film to Enhance the Efficiency of Organic Light Emitting Diode with UV protection)

  • 장현준;성백상;한소라;이주호;김용현;이재현;이종희
    • 전기전자학회논문지
    • /
    • 제28권3호
    • /
    • pp.329-336
    • /
    • 2024
  • 유기발광다이오드(OLED)는 층간 굴절률 차이로 내부 전반사가 발생하며 낮은 광추출 효율의 원인이 된다. 그 결과, MLA와 같은 구조체를 활용하는 광추출 기술들이 연구되고 있다. 하지만 MLA와 같은 석유계 고분자를 활용한 기술들은 폐기 과정에서 환경 문제를 야기한다. 따라서 본 연구에서는 친환경 고분자 hydroxyethyl cellulose(HEC)와 tannic acid(TA)를 활용하여 외부 광추출 필름을 제작하고자 한다. HEC는 생분해가 가능하며 높은 투명도를 가져 친환경 외부 광추출 필름으로 제작하는데 적합하다. 첨가제로 사용된 TA는 폴리페놀 화합물로 HEC와 견고한 수소결합을 형성할 것으로 예상된다. 또한, TA는 페놀 그룹을 통해 자외선으로부터 OLED가 손상되는 것을 방지할 수 있다. HECTA MLA 필름은 추가적인 용매를 사용하지 않고 물에 HEC와 TA를 용해시킨 후 MLA 몰드에 임프린팅 하여 제작하였다. HECTA MLA 필름을 OLED 외부에 부착하여 분석한 결과, 80% 이상의 높은 흐림도를 보였으며 OLED의 외부 양자 효율과 전류 효율이 기준 대비 각각 38%, 39% 향상되었다.

Wire bonding 자동 전단력 검사를 위한 wire의 3차원 위치 측정 시스템 개발 (3D Measurement System of Wire for Automatic Pull Test of Wire Bonding)

  • 고국원;김동현;이지연;이상준
    • 제어로봇시스템학회논문지
    • /
    • 제21권12호
    • /
    • pp.1130-1135
    • /
    • 2015
  • The bond pull test is the most widely used technique for the evaluation and control of wire bond quality. The wire being tested is pulled upward until the wire or bond to the die or substrate breaks. The inspector test strength of wire by manually and it takes around 3 minutes to perform the test. In this paper, we develop a 3D vision system to measure 3D position of wire. It gives 3D position data of wire to move a hook into wires. The 3D measurement method to use here is a confocal imaging system. The conventional confocal imaging system is a spot scanning method which has a high resolution and good illumination efficiency. However, a conventional confocal systems has a disadvantage to perform XY axis scanning in order to achieve 3D data in given FOV (Field of View) through spot scanning. We propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array to remove XY scan. 2D imaging system can detect 2D location of wire and it can reduce time to measure 3D position of wire. In the experimental results, the proposed system can measure 3D position of wire with reasonable accuracy.

평판 디스플레이용 Laser Direct Imaging에 관한 연구( I ) (A Study on the Laser Direct Imaging for FPD ( I ))

  • Kang, H.S.;Kim, K.R.;Kim, H.W.;Hong, S.K.
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.37-41
    • /
    • 2005
  • When screen size of the Flat Panel Display (FPD) becomes larger, the traditional photo-lithography using photomasks and UV lamps might not be possible to make patterns on Photo Resist (PR) material due to limitation of the mask size. Though the maskless photo-lithography using UV lasers and scanners had been developed to implement large screen display, it was very slow to apply the process for mass-production systems. The laser exposure system using 405 nm semi-conductor lasers and Digital Micromirror Devices (DMD) has been developed to overcome above-mentioned problems and make more than 100 inches FPD devices. It makes very fine patterns for full HD display and exposes them very fast. The optical engines which contain DMD, Micro Lens Array (MLA) and projection lenses are designed for 10 to 50 ${\mu}m$ bitmap pattern resolutions. The test patterns for LCD and PDP displays are exposed on PR and Dry Film Resists (DFR) which are coated or laminated on some specific substrates and developed. The fabricated edges of the sample patterns are well-defined and the results are satisfied with tight manufacturing requirements.

  • PDF

Usefulness of a 1,064 nm Microlens Array-type, Picosecond-dominant Laser for Pigmented Scars with Improvement of Vancouver Scar Scale

  • Ahn, Kwang Hyeon;Park, Eun Soo;Nam, Seung Min
    • Medical Lasers
    • /
    • 제8권1호
    • /
    • pp.19-23
    • /
    • 2019
  • Background and Objectives The picosecond 755 nm alexandrite laser was first approved by the US FDA in 2012. A previous study described the use of a 1,064 nm picosecond laser with a micro-lens array (MLA) in peri-areolar scarring from breast reconstruction surgery and reported significant improvement in the texture and aesthetic appearance of the scar without other wound complications. The purpose of this study was to evaluate the improvement of overall scarring, not just pigmentation, in the picosecond laser treatment of patients with pigmentations. Materials and Methods Sixteen patients who underwent 1,064 nm picosecond laser treatment from June 2016 to December 2018 were enrolled in this study. Patients received two to six sessions of picosecond laser treatment at intervals of 4 weeks. Before and after the laser treatment, the patients evaluated their own satisfaction score and a physician evaluated the Vancouver Scar Scale. To evaluate the satisfaction score and complication rate, a retrospective chart review was done. Results Seven were female and nine were male. The mean of the patients' satisfaction score before the treatment was 1.44 (interquartile range [IQR], 1-2) and 3.00 (IQR 2.25-3.75) six months after treatment. The mean of the Vancouver Scar Scale before the treatment was 9.69 (IQR 8-11), and 6.25 (IQR 5-7.75) six months after treatment. All the results were statistically significant (p<0.01). Conclusion This study provides evidence that the use of a 1,064 nm picosecond laser treatment for pigmented scars can be effective in improving the pigmentation and overall scar status, including vascularity, height, and pliability, with the results of a decrease in the VSS scores between treatments.