• 제목/요약/키워드: MLA(Microlens array)

검색결과 19건 처리시간 0.026초

Polydeoxyribonucleotide and Microlens Array-type, Nanosecond-domain Neodymium:Yttrium-aluminum-garnet Laser Treatment for Scars from Costal Cartilage Harvest Surgery: Case Series of 9 Patients

  • Ahn, Keun Jae;Kim, Do Yeon;Cheon, Gwahn-Woo;Park, Hyun Jun;Ahn, Tae Hwan
    • Medical Lasers
    • /
    • 제10권2호
    • /
    • pp.90-95
    • /
    • 2021
  • Background and Objectives Surgery for harvesting costal cartilage is often required for revision septorhinoplasty due to a lack of septal cartilage in patients with a severely contracted nose, and postoperative scarring on the anterolateral rib cage commonly requires additional treatment. This study aimed to evaluate the therapeutic efficacy and safety of combined polydeoxyribonucleotide (PDRN) and microlens array (MLA)-type nanosecond-domain neodymium (Nd):yttrium-aluminum-garnet (YAG) laser treatment for postoperative scars after costal cartilage harvest surgery. Materials and Methods Nine Korean patients with scars after costal cartilage harvest surgery treated with PDRN injections and MLA-type Nd:YAG laser treatments were retrospectively reviewed. Results Most of the scar lesions exhibited clinical improvement at 2 weeks after PDRN and MLA-type nanosecond-domain laser treatments, and the lesions further improved after adding more treatment sessions. The median Vancouver Scar Scale (VSS) score decreased from 6 (interquartile range [IQR]: 6-7) before combined intralesional PDRN injection and MLA-type, nanosecond-domain Nd:YAG laser treatments to 3 (IQR: 2-4) thereafter. Patient satisfaction after the combination treatments was rated as satisfactory. None of our patients reported major adverse events. Conclusion This case series study demonstrated that combined PDRN and MLA-type, nanosecond-domain Nd:YAG laser treatments are effective and safe for treating scars from costal cartilage harvest surgery.

다중 배열 니들 코팅을 이용한 LED 스크린용 Anti-Moiré 필터 제작 (Fabrication of Anti-Moiré Filter Using Multi-Array Needle Coating for LED Screens)

  • 전경준;이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제20권1호
    • /
    • pp.77-82
    • /
    • 2021
  • Using a multi-array needle module developed for coating of high-density cylindrical microlens array (C-MLA), we have fabricated an anti-Moiré filter for LED screens. The Moiré phenomenon appears due to the interference between the array pattern of image sensors in a camera and the non-emission area (grid pattern) of a LED screen. To suppress it, we have employed poly(methyl methacrylate) (PMMA) and coated it on a glass substrate in the form of a grid and non-grid (parallel lines). We have rotated the needle module in order to increase the number of C-MLAs. With this scheme, we have fabricated the 150 mm × 150 mm anti-Moiré filters where 836 microlens lines are formed. They show the average width of 255.4 ㎛, the average distance between CMLs of 94.6 ㎛, and C-MLA width non-uniformity of 4.7%. We have shown that the Moiré patterns still appear in the presence of the parallel (non-grid)-type filter, whereas they disappeared completely by the grid-type filter. It is due to the fact that the Moiré patterns are diffused more effectively by the grid-type C-MLA.

투명 OLED 면광원 광 추출 향상 기술 (Enhancement of Light Extraction from Transparent OLED Lighting Panels)

  • 박준범;신동균;한승조;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제16권4호
    • /
    • pp.41-45
    • /
    • 2017
  • We have investigated the light extraction efficiency of large-area OLED lighting panels with a microlens array (MLA) or external scattering layer (ESL) by ray tracing simulation. The application of MLA and ESL to transparent OLEDs (TOLEDs) with an auxiliary metal electrode is also studied. It is found that MLA shows higher light extraction efficiency, compared with ESL. However, we have demonstrated that ESL is more suitable for TOLEDs having dual-sided equal light emission. Namely, equal light emission from the front and rear surfaces of TOLED can be achieved by increasing the scattering particle density of ESL. To compensate for a loss in light emission induced by auxiliary metal electrode, we come out with an OLED structure partially covered with MLA at the outer surface of glass substrate, which is aligned with metal electrode. With this scheme, it is observed that the light extraction efficiency can be boosted more than 20% from opaque OLED and 50% from transparent OLED.

  • PDF

무안경 완전시차 입체 재현을 위한 서브픽셀 다중화 (Sub-pixel Multiplexing for Autostereoscopic Full Parallax 3D)

  • 음호민;이광순
    • 한국멀티미디어학회논문지
    • /
    • 제20권12호
    • /
    • pp.2009-2015
    • /
    • 2017
  • A two-dimensional lens is required to reproduce both the horizontal and vertical parallax through an autostereoscopic 3D display. Among the two-dimensional lenses, a hexagonal micro lens array (MLA) having good optical efficiency is mainly used. However, the hexagonal MLA has complex geometric features. The first feature is that the lens cells are zigzagged in the vertical direction, which should be reflected in the view number calculation for each sub-pixel. The second feature is that the four sides of a hexagonal lens cell are tilted, requiring a more careful view index assignment to the lens cell. In this paper, we propose a sub-pixel multiplexing scheme suitable for the features of the hexagonal MLA. We also propose a view-overlay algorithm based on a two-dimensional lens and compare subjective image quality with existing view-selection through autostereoscopic 3D display implementation.

음각, 양각 광학패턴 적용 휴대폰용 도광판 금형 제작 및 광특성 연구 (Replication of concave and convex microlens array of light guide plate for liquid crystal display in injection molding)

  • 황철진;김종선;강정진;홍석관;윤경환
    • Design & Manufacturing
    • /
    • 제2권2호
    • /
    • pp.29-32
    • /
    • 2008
  • A back light unit (BLU) is a key module of a thin film transistor liquid crystal display (TFT-LCD), frequently utilized in various mobile displays. In this study, we experimentally characterize transcription and optical properties of concave and convex microlens arrays (MLAs) of light guide plate (LGP) fabricated by injection molding with polycarbonate as a LGP substrate material. Nickel mold inserts were manufactured by electroforming on the MLA which was fabricated by the thermal reflow of photoresist microstructures patterned by UV-photolithography. For the case of convex microlens, the height of replicated microlens was less than that of the mold insert while maintaining almost the same microlens diameter of the mold insert as the location of the microlens is far from the gate. In contrast, for the concave microlens, the diameter of replicated microlens was larger than that of mold insert, while showing almost the same microlens height as the mold insert. From the optical examination of replicated convex and concave MLAs, it was found that a higher luminance of the LGP was achieved by the concave MLAs compared to the convex MLAs (about 30% enhancement in this case)due to the utilization of a larger amount of light provided by the light sources.

  • PDF

In Vivo and Ex Vivo Skin Reactions after Multiple Pulses of 1,064-nm, Microlens Array-type, Picosecond Laser Treatment

  • Lyu, Herin;Park, Jinyoung;Lee, Hee Chul;Lee, Sang Ju;Kim, Young Koo;Cho, Sung Bin
    • Medical Lasers
    • /
    • 제9권2호
    • /
    • pp.142-149
    • /
    • 2020
  • Background and Objectives A picosecond-domain laser treatment using a microlens array (MLA) or a diffractive optical element elicits therapeutic micro-injury zones in the skin. This study examined the patterns of tissue reactions after delivering multiple pulses of 1,064-nm, MLA-type, picosecond neodymium:yttrium-aluminum-garnet laser treatment. Materials and Methods Multiple pulses of picosecond laser treatment were delivered to ex vivo human or brown micropig skin and analyzed histopathologically. A high-speed cinematographic study was performed to visualize the multiple pulses of picosecond laser energy-induced skin reactions in in vivo human skin. Results In the ex vivo human skin, a picosecond laser treatment at a fluence of 0.3 J/cm2 over 100 non-stacking passes generated multiple lesions of thermally-initiated laser-induced optical breakdown (TI-LIOB) in the epidermis and dermis. In the ex vivo micropig skin, stacking pulses of 20, 40, 60, 80, and 100 at a fluence of 0.3 J/cm2 generated distinct round to oval zones of tissue coagulation in the mid to lower dermis. High-speed cinematography captured various patterns of twinkling, micro-spot reactions on the skin surface over 100 stacked pulses of a picosecond laser treatment. Conclusion Multiple pulses of 1,064-nm, MLA-type, picosecond laser treatment elicit marked TI-LIOB reactions in the epidermis and areas of round to oval thermal coagulation in the mid to deep dermis.

인체안 단색수차의 타각식 계측을 위한 파면분석기 연구 (Study on the wavefront analyzer for objective measuring the monochromatic aberrations of human eye)

  • 강돈희;고동섭;손진욱;권혁제;김현수
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 제14회 정기총회 및 03년 동계학술발표회
    • /
    • pp.134-135
    • /
    • 2003
  • 인체안의 단색수차는 시력의 한계를 규정하고 또한 안광학 기기의 설계에 있어서 중요한 요소이기 때문에 오래 전부터 많은 관심을 갖게 되었다. 또한 단색수차를 정밀하게 측정함으로써 가장 이상적인 시력 교정 방법을 찾을 수 있다. 본 연구에서는 먼저 그림 1과 같은 Shack-Hartmann (SH) 파면분석기를 구성하였다. 이 파면분석기는 대물렌즈, 결상렌즈, 미소렌즈배열(microlens array, MLA), 그리고 이미지 센서(CCD)로 구성되어 있다. (중략)

  • PDF

Usefulness of a 1,064 nm Microlens Array-type, Picosecond-dominant Laser for Pigmented Scars with Improvement of Vancouver Scar Scale

  • Ahn, Kwang Hyeon;Park, Eun Soo;Nam, Seung Min
    • Medical Lasers
    • /
    • 제8권1호
    • /
    • pp.19-23
    • /
    • 2019
  • Background and Objectives The picosecond 755 nm alexandrite laser was first approved by the US FDA in 2012. A previous study described the use of a 1,064 nm picosecond laser with a micro-lens array (MLA) in peri-areolar scarring from breast reconstruction surgery and reported significant improvement in the texture and aesthetic appearance of the scar without other wound complications. The purpose of this study was to evaluate the improvement of overall scarring, not just pigmentation, in the picosecond laser treatment of patients with pigmentations. Materials and Methods Sixteen patients who underwent 1,064 nm picosecond laser treatment from June 2016 to December 2018 were enrolled in this study. Patients received two to six sessions of picosecond laser treatment at intervals of 4 weeks. Before and after the laser treatment, the patients evaluated their own satisfaction score and a physician evaluated the Vancouver Scar Scale. To evaluate the satisfaction score and complication rate, a retrospective chart review was done. Results Seven were female and nine were male. The mean of the patients' satisfaction score before the treatment was 1.44 (interquartile range [IQR], 1-2) and 3.00 (IQR 2.25-3.75) six months after treatment. The mean of the Vancouver Scar Scale before the treatment was 9.69 (IQR 8-11), and 6.25 (IQR 5-7.75) six months after treatment. All the results were statistically significant (p<0.01). Conclusion This study provides evidence that the use of a 1,064 nm picosecond laser treatment for pigmented scars can be effective in improving the pigmentation and overall scar status, including vascularity, height, and pliability, with the results of a decrease in the VSS scores between treatments.

수치 구경 불일치 플렌옵틱 현미경 성능 예측 방안 연구 (Performance Prediction for Plenoptic Microscopy Under Numerical Aperture Unmatching Conditions)

  • 연하늘;이찬;한석기;이준호
    • 한국광학회지
    • /
    • 제35권1호
    • /
    • pp.9-17
    • /
    • 2024
  • 현미경용 플렌옵틱 광학 시스템은 일반적으로 대물 렌즈, 튜브 렌즈, 마이크로 렌즈 어레이, 그리고 이미지 센서로 구성된다. 플렌옵틱을 통한 라이트 필드 이미징에서 튜브 렌즈와 마이크로 렌즈 어레이 간의 수치 구경을 일치시키고, 이를 바탕으로 공간분해능 및 피사계심도 등의 성능 지표를 예측한다. 하지만 상업적 마이크로 렌즈 어레이 적용시 이러한 수치 구경 일치에 어려움이 있어, 본 논문에서는 기존에 보고된 성능 예측 수식을 수치 구경이 일치하지 않는 경우까지 확장하고, 전산 시뮬레이션을 통한 성능 예측 기법을 제시하며, 이를 수치 구경 일치화가 이루어진 10배율 및 수치 구경 불일치가 발생한 20배율 대물렌즈가 적용된 두 개의 플렌옵틱 광학계 개발 및 실험을 통하여 검증하였다. 10배율 및 20배율 시스템은 확장식에서 각각 12.5 ㎛, 6.2 ㎛의 공간 분해능과 530 ㎛, 88 ㎛의 피사계심도를 가지며, 시뮬레이션에서는 각각 11.5 ㎛, 5.8 ㎛의 공간분해능과 510 ㎛, 70 ㎛의 피사계심도를, 실험에서는 각각 11.1 ㎛, 5.8 ㎛의 공간 분해능과 470 ㎛, 70 ㎛의 피사계심도를 가진다. 확장식 및 시뮬레이션 모두 실험 값과 유사한 결과를 보여 시스템 설계에서는 두 가지 방법 모두 적절할 것으로 판단된다. 다만 피사계심도 예측 정확성에 있어서는 시뮬레이션에 의한 예측이 실험 값과 좀 더 유사하므로, 실제 제작에 앞서 시뮬레이션에 의한 성능 예측을 추천한다.