• Title/Summary/Keyword: MG Safety System

Search Result 213, Processing Time 0.019 seconds

TLC, HPTLC FINGERPRINTING AND ACUTE ORAL TOXICITY EVALUATION OF HABB-E-AZARAQI: A NUX-VOMICA-BASED TRADITIONAL UNANI FORMULATION

  • Ara, Shabnam Anjum;Viquar, Uzma;Zakir, Mohammed;Husain, Gulam Mohammed;Naikodi, Mohammed Abdul Rasheed;Urooj, Mohd;Kazmi, Munawwar Husain
    • CELLMED
    • /
    • v.11 no.3
    • /
    • pp.13.1-13.9
    • /
    • 2021
  • Background and Objective: Nux-vomica based traditional Unani formulation, Habb-e-Azaraqi (HAZ) is an important drug used by Unani physicians since several decades. It possesses Muqawwi-i-A'sab (nervine tonic), Muharrik-i-A'sab (nervine stimulant) properties and is an effective treatment option for diseases like Laqwa (facial palsy), Falij (paralysis), Niqris (gout) and Waja'al-Mafasil (arthritis) etc. The aim of the study is to access and provide information of HAZ for its TLC, HPTLC Fingerprinting defining its clear qualitative perspective and acute oral toxicity evaluation for its safety assessment which was not done earlier, thus contributing in the field of research. Materials and Methods: The chief ingredient, nux-vomica was detoxified as per method mentioned in Unani Pharmacopeia before its use in formulation. TLC and HPTLC was developed under four detection system i.e., UV 366nm, UV 254nm, exposure to iodine vapours and after derivatization with anisaldehyde sulphuric acid. Acute toxicity studies were performed as per OECD Guidelines 425 at a limit dose of 2000 mg/kg. Observations were done for signs of toxicity, body weight, and feed consumption at regular intervals followed by haematological and biochemistry evaluation. Results: The generated data proved the authenticity and established the TLC and HPTLC profile of the formulation. Acute toxicity revealed no significant differences in HAZ-treated animals with respect to body weight gain, feed consumption, haematology, clinical biochemistry evaluation. No significant gross pathological observation was noticed in necropsy. Conclusion: Data of the present study is substantial and scientific proof of HAZ in terms of standardization and toxicity study that can be utilize in future research activities.

Analysis of activated colloidal crud in advanced and modular reactor under pump coastdown with kinetic corrosion

  • Khurram Mehboob;Yahya A. Al-Zahrani
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4571-4584
    • /
    • 2022
  • The analysis of rapid flow transients in Reactor Coolant Pumps (RCP) is essential for a reactor safety study. An accurate and precise analysis of the RCP coastdown is necessary for the reactor design. The coastdown of RCP affects the coolant temperature and the colloidal crud in the primary coolant. A realistic and kinetic model has been used to investigate the behavior of activated colloidal crud in the primary coolant and steam generator that solves the pump speed analytically. The analytic solution of the non-dimensional flow rate has been determined by the energy ratio β. The kinetic energy of the coolant fluid and the kinetic energy stored in the rotating parts of a pump are two essential parameters in the form of β. Under normal operation, the pump's speed and moment of inertia are constant. However, in a coastdown situation, kinetic damping in the interval has been implemented. A dynamic model ACCP-SMART has been developed for System Integrated Modular and Advanced Reactor (SMART) to investigate the corrosion due to activated colloidal crud. The Fickian diffusion model has been implemented as the reference corrosion model for the constituent component of the primary loop of the SMART reactor. The activated colloidal crud activity in the primary coolant and steam generator of the SMART reactor has been studied for different equilibrium corrosion rates, linear increase in corrosion rate, and dynamic RCP coastdown situation energy ratio b. The coolant specific activity of SMART reactor equilibrium corrosion (4.0 mg s-1) has been found 9.63×10-3 µCi cm-3, 3.53×10-3 µC cm-3, 2.39×10-2 µC cm-3, 8.10×10-3 µC cm-3, 6.77× 10-3 µC cm-3, 4.95×10-4 µC cm-3, 1.19×10-3 µC cm-3, and 7.87×10-4 µC cm-3 for 24Na, 54Mn, 56Mn, 59Fe, 58Co, 60Co, 99Mo, and 51Cr which are 14.95%, 5.48%, 37.08%, 12.57%, 10.51%, 0.77%, 18.50%, and 0.12% respectively. For linear and exponential coastdown with a constant corrosion rate, the total coolant and steam generator activity approaches a higher saturation value than the normal values. The coolant and steam generator activity changes considerably with kinetic corrosion rate, equilibrium corrosion, growth of corrosion rate (ΔC/Δt), and RCP coastdown situations. The effect of the RCP coastdown on the specific activity of the steam generators is smeared by linearly rising corrosion rates, equilibrium corrosion, and rapid coasting down of the RCP. However, the time taken to reach the saturation activity is also influenced by the slope of corrosion rate, coastdown situation, equilibrium corrosion rate, and energy ratio β.

Electrode Characteristics of K+ Ion-Selective PVC Membrane Electrodes with AC Impedance Spectrum (AC 임피던스 분석법을 이용한 K+ 이온선택성 PVC막 전극 특성)

  • Kim, Yong-Ryul;An, Hyung-Hwan;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.870-877
    • /
    • 1998
  • With impedance spectrum measurements, impedance was studied in the interface between sample solutions for $K^+-ion$ selective PVC membrane electrode containing neutral carriers [dibenzo-18-crown-6 (D18Cr6) and valinomycine (Val)]. Response characteristics of electrode were examined by measuring AC impedance spectra that were resulted from the chemical structure and the content of carrier, variation of plasticizer, membrane thickness, doping of base electrolytes, and concentration variation of sample solution. Transport characteristics of PVC membrane electrode were also studied. It was found that the equivalent circuit for the membrane in $K^+$ solution could be expressed by a series combination of solution resistance and a parallel circuit consisting of the bulk resistance and geometric capacitance of the membrane system. But the charge transfer resistance and Warburg resistance were overlapped a little in the low concentration and low frequency ranges. The carrier, D18Cr6 was best for electrode and impedance characteristics, and ideal electrode characteristics were appeared especially in case of doping of the base electrolyte[potassium tetraphenylborate(TPB)]. The optimum carrier content was about 3.23 wt% in case of D18Cr6 and Val. DBP was best as a plasticizer. As membrane thickness decreased the impedance characteristics was improved, but electrode characteristics were lowered for membrane thickness below the optimum. In the case of D18Cr6, the selectivity coefficients by the mixed solution method for the $K^+$ ion were the order of $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF