• 제목/요약/키워드: MF membrane filtration

검색결과 64건 처리시간 0.021초

고도정수처리에서 사여과와 정밀여과의 유기물처리특성에 관한 연구 (Treatment Characteristics of Sand Filtration and Microfiltration (MF) in Advanced Water Treatment)

  • 김형석;이병호
    • 상하수도학회지
    • /
    • 제24권6호
    • /
    • pp.723-734
    • /
    • 2010
  • With a belief of high water quality production and less chemical usage, membrane technology including Microfiltration (MF), Ultrafiltration (UF), and Nanofiltration(NF) is being employed more and more in drinking water treatment process. However, due to higher energy consumption of UF and NF, MF is normally used for drinking water treatment especially in a plant of large scale. In this investigation, performance ofsand filtration and membrane filtration was compared regarding removal of various water quality parameters, such as TOC, DOC, KMnO4 consumption, THMFP, and HAAFP. Two lines of pilot plant have been operated, one of which line is a traditional advanced water treatment process which includes sedimentation, sand filtration, ozonation, and activated carbon, and the other line is an alternative treatment process which includes sedimentation with inclined plate, MF membrane, ozonation, and activated carbon. For the first about 4months of period, MF filtration showed similar or little bit higher performance than sand filtration. However, after about 4month later, sand filtration showed much higher performance in removing all parameters monitored in the investigation. It was found that sand filtration is a better option than MF filtration as far as microbial community is fully activated in sand filter bed.

에너지절약형 VSA MF Membrane 수처리 시스템 (Effective Water Treatment Process by Hollow Fiber MF Membranes; VAS(Vibrating & Stripping by Air ) Process)

  • 김정학
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 Energy Saving Membrane Separtion Systems 에너지 절약형 막분리 시스템
    • /
    • pp.93-116
    • /
    • 1999
  • MF membrane element was specially designed for water purification and VSA process which can solve the fouling problem. Especially VSA process is developed for the SK Chemicals' asymmetric microfiltration hollow fiber membranes. In case of outside-to-in filtration process, MF membrane element showed the excellent flux stability caused by cleaning ability of VSA process . Simultaneous back-washing with VSA consideratbly enhances cleaning efficiency. From the result the possibility of the replacement of chemical coagulation and sand filtration process with newly developed VSA process was revealed.

  • PDF

완속모래여과 공정에서 세라믹 MF 막의 적용 (Application of Ceramic MF Membrane at the Slow Sand Filtration Process)

  • 최광훈;박종율;김수한;김정숙;강임석
    • 대한환경공학회지
    • /
    • 제35권12호
    • /
    • pp.877-882
    • /
    • 2013
  • 최근 음용수를 위한 UF, MF 막의 적용이 증가하고 있다. UF/MF 막은 재래식 수처리 공정에 비하여 원수 수질 변화에도 안정적인 운전이 가능하고 부지 면적이 작으며 자동화 운전이 가능하다는 장점을 가지고 있다. 현재 대부분의 UF/MF 막시설은 고분자 막을 사용하고 있다. 최근 세라믹 막은 고분자막에 비하여 경쟁력이 있다고 알려지고 있다. 세라믹 막은 높은 투과유량과 약품세정 빈도가 작으며 막의 수명 또한 길어 최근 적용 사례가 증가하고 있다. 따라서 본 연구는 MF 세라믹 막 pilot plant를 완속모래여과 정수장에 적용하였다. 본 연구에 사용된 세라믹 Pilot plant는 3개의 계열이 있으며, 각 계열별로 원수와 모래 여과수를 막의 유입수로 각각 사용하였다. 또한 세라믹 막 공정의 최적화를 위하여 전처리 응집공정으로서 PACl 응집제를 사용하였다. 그리고 화학세정(Chemical Enhanced Backwashing, CEB)은 황산 (500 mg/L)과 차아염소산 (200 mg/L)을 1.5일에 1번씩 모든 계열에 주입하여 이루어졌다. 본 연구 결과 세라믹 막 공정의 전처리 응집공정에서 최적의 응집제 사용은 막의 유입수로 원수와 모래 여과수에 대한 막의 flux를 크게 증가시켰다. 또한 본 연구에서 사용된 최적 응집제 주입량에서 차압상승률은 원수(25 mg/L)의 경우 2.173 kPa/cycle이며, 모래 여과수(5 mg/L)의 경우 0.301 kPa/cycle으로 나타났다.

EFFECTIVE WATER TREATMENT PROCESS BY HOLLOW FIBER MEMBRANES : VAS (VIBRATING & STRIPPING BY AIR) PROCESS

  • Kim, Jeong-Hak
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 The 7th Summer Workshop of the Membrane Society of Korea
    • /
    • pp.63-66
    • /
    • 1999
  • MF membrane element was specially designed for water purification and VSA process which can solve the fouling problem. Especially VSA process is developed for the SK Chemical's asymmetric microfiltration hollow fiber membranes. In case of outside-to-in filtration process, MF membrane element showed the excellent flux stability caused by cleaning ability of VSA process. Simultaneous back- washing with VSA considerably enhances cleaning efficiency. Form the result, the possibility of the replacement of chemical coagulation and sand filtration process with newly developed VSA process was revealed.

  • PDF

고농도 휴믹성분이 포함된 강 원수에서 응집-침전 및 오존 공정을 전처리로 적용한 오존 내성막 pilot plant에서의 운전성 및 투과수 수질변화에 관한 연구 (Pre-Coagulation and Pre-Ozonation for Ozone Resisting Microfiltration Membrane Filtration System of a High Humic Contained Surface Water)

  • 이상협;와타나베 요시마사;이석헌;안규홍
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.598-607
    • /
    • 2004
  • In this study, the effects of two pre-treatment processes were observed prior to membrane filtration: pre-coagulation and pre-ozonation. To compare the effect of two above-mentioned pre-treatments, we adopted the four schemes: first one is direct membrane filtration of river surface water, second one is membrane filtration after pre-coagulation, third one is membrane filtration after pre-ozonation and fourth one is membrane filtration after pre-coagulation and pre-ozonation. There are two exceptional characteristics in applied processes. One is the usage of the MF membrane which has high ozone resisting characteristic. Therefore, ozone resides in membrane module during filtration. The other is adoption of Jet Mixed Separator (JMS) as coagulation-sedimentation process. The change in transmembrane pressure and permeate water quality were also examined. As a result, considering the filtration performance efficiency and permeate water quality, the process composed of filtration with combination of both pre-coagulation and pre-ozonation was proved most effective. The improved efficiency was due to the reduction of loading rate of fouling inducing materials to membrane module by coagulation process as well as variable reactions, such as degradation, particle destabilization and coagulation, occurred by residual ozone in membrane module. The additional effect of pre-coagulation before pre-ozonation is suppression of AOC, one of the by-products induced by ozonation. Therefore, combination of pre-coagulation and pre-ozonation is the effective process to overcome the major de-merit of ozonation i.e. by-products formation.

Biofilter pretreatment for the control of microfiltration membrane fouling

  • Park, Jae-Hyung;Satoshi Takizawa;Hiroyuki Katayama;Shinichiro Ohgaki
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2003년도 춘계 총회 및 학술발표회
    • /
    • pp.31-38
    • /
    • 2003
  • A pilot scale biofilter pretreatment-microfiltration system (BF-MF) was operated to investigate the effect of biofilter treatment in fouling reduction of microfiltration. Biofiltration was expected to reduce the membrane fouling by removal of turbidity and metal oxides. The hollow-fiber MF module with a nominal pore size of 0.1$\mu$m and a surface area of 8m$^2$ was submerged in a filtration tank and microfiltration was operated at a constant flux of 0.5 m/d. Biofiltration using polypropylene pellets was performed at a high filtration velocity of 320 m/d. Two experimental setups composed of MF and BF/MF, i.e., without and with biofilter pretreatment, were compared. Throughout the experimental period of 9 months, biofilter pretreatment was effective to reduce the membrane fouling, which was proved by the result of time variations of trans-membrane pressure and backwash conditions. The turbidity removal rate by biofiltration varied between 40% to 80% due to the periodic washing for biofilter contactor and raw water turbidity. In addition to turbidity, metals, especially Mn, Fe and Al were removed effectively with average removal rates of 89.2%, 67.8% and 64.9%, respectively. Further analysis of foulants on the used membranes revealed that turbidity and metal removal by biofiltration was the major effect of biofiltration pretreatment against microfiltration fouling.

  • PDF

해수담수화 전처리 및 역삼투막여과 공정의 유기물 제거특성 (Removal Characteristics of Organic Matters in Pretreatment and Reverse Osmosis Membrane Processes for Seawater Desalination)

  • 김동관;최준석;이창규;김진호;최정학;이원태
    • 대한환경공학회지
    • /
    • 제36권7호
    • /
    • pp.492-497
    • /
    • 2014
  • 해수담수화 시설에서 전처리와 역삼투막(reverse osmosis, RO) 공정의 유기물 제거특성을 살펴보고, 유기물의 특성변화가 막오염 지수에 미치는 영향을 조사하였다. 연구에서 비교된 전처리 공정은 다중여재여과(dual media filter, DMF), 가압형 정밀여과(MF), 침지형정밀여과(SMF) 이다. 유기물의 특성변화를 알아보기 위해 원수와 공정별 처리수의 탁도, $UVA_{254}$, DOC, size exclusion chromatography (SEC), fluorescence excitation emission matrix (FEEM), transparent exopolymer particles (TEP) 등을 분석하였다. 이온성 물질과 무기물 항목은 전처리 공정의 종류에 관계없이 처리되지 않았고 RO공정을 거치면서 99% 이상 제거되었다. 유기물에 의한 막오염에 큰 영향을 미치는 소수성 유기물은 전처리를 통해 상대적으로 제거가 용이하였다. 전처리 공정의 유기물 제거율은 막여과 공정(MF, SMF)이 기존 DMF 공정에 비해 높았다. 처리수내 유기물의 농도가 감소할수록 막오염지수 중 하나인 silt density index (SDI) 값도 감소하였다. MF로 전처리한 경우 SDI값이 가장 낮게 나타났는데, 처리수 내의 $0.1-0.4{\mu}m$ TEP 농도가 MF와 SMF 막오염지수의 차이와 상관관계를 보였다.

상수처리를 위한 파일롯 규모의 정밀여과/한외여과 시스템 (A Pilot-Scale Microfiltration/Ultrafiltration system for Drinking Water Treatment)

  • 김한승;오정익;김충환
    • 상하수도학회지
    • /
    • 제18권6호
    • /
    • pp.770-777
    • /
    • 2004
  • Three pilot-scale membrane systems were operated using lake water as influent in this study. Microfiltration (MF) membrane with pore size of 0.01 m was used in Systen I of which filtration mode was set at constant pressure of $1kgf/cm^2$. Ultrafiltration (UF) membranes with molecular cutoff (MWCO) of 80,000 and 13,000 were used in System II-1 and II-2, respectively. Constant flow mode was applied at the range between 0.7 and $1.5m^3/m^2{\cdot}d$ (average of $1.1m^3/m^2${\cdot}d) for System II-1 and between 0.37 and $1.65m^3/m^2{\cdot}d$ (average of $1.18m^3/m^2{\cdot}d$) for System II-2. In System I, the flux changed from $1m^3/m^2{\cdot}d$ to $0.2m^3/m^2{\cdot}d$ during the operation time of 5 months. System II showed recovery of 94% under the allowable maximum pressure of $3kgf/cm^2$ during the same operation period. From these results, the efficient operation was observed in constant flow mode with respect to filtration time and recovery. Average filtrate turbidity showed 0.0071 NTU in System I and 0.0054 NTU in System II, which implied that high turbidity removal was obtained in both MF and UF systems with no significant difference between MF and UF. From the fact that membrane flux depends largely on membrane type and operation mode, a guideline of optimum design and operation should be suggested for application of membrane systems to full scale water treatment.

지표수에서의 분변오염지표세균 (대장균군) 검출방법의 비교연구 (Comparative Studies on Detecting Methods of Fecal Indicators (Coliforms) in Surface Water)

  • 박지은;김선덕;조주래;김상현;이혜진;이영옥
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1052-1059
    • /
    • 2006
  • For monitoring the fecal pollution at Nak-Dong River, one of the eutrophicated rivers, the differences between total coliforms (TC) and fecal coliforms (FC) using both of membrane filtration (MF)/MPN method, and also fecal streptococcus (FS) by MF-method was investigated. To evaluate the correlation between TC, FC, and FS statistical analyses were performed by using Minitab. And a part of the presumptive TC/FC and background colonies was purified and identified using API 20E kit (Biomeriux). As results, most (89%) of presumptive FC by MF was identified as Escherichia coli while only 14% (MPN) and 11% (MF) of TC were identified as E. coli. Furthermore, FC by MF was correlated significantly with other fecal indicators (TC/FS by MF and FC by MPN), while TC by MPN was not correlated with any other indicators. Thus, the detection of FC by MF-method may be the most reasonable for monitoring the fecal pollution.