• Title/Summary/Keyword: ME test

Search Result 467, Processing Time 0.027 seconds

Experimental investigation on the degradation of SiGe LNAs under different bias conditions induced by 3 MeV proton irradiation

  • Li, Zhuoqi;Liu, Shuhuan;Ren, Xiaotang;Adekoya, Mathew Adefusika;Zhang, Jun;Liu, Shuangying
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.661-665
    • /
    • 2022
  • The 3 MeV proton irradiation effects on SiGe low noise amplifier (LNA) (NXP BGU7005) performance under different voltage supply VCC (0 V, 2.5 V) conditions were firstly experimental studied in this present work. The S parameters including S11, S22, S21, 1 dB compression point and noise figure (NF) of the test samples under different bias voltage supply were measured and compared before and after 3 MeV proton irradiation. The total proton irradiation fluence was 1 × 1015 protons/cm2. The maximum degradation quantities of the gain S21 and NF of the test samples under zero bias are measured respectively 1.6 dB and 1.2 dB. Compared with the samples under 2.5 V bias supply, the maximum degradation of S21 and NF are respectively 1.1 dB and 0.8 dB in the whole frequency band. It is noteworthy that the gain and NF of SiGe LNAs under zero-bias mode suffer enhanced degradation compared with those under normal bias supply. The key influence factors are discussed based on the correlation of the SiGe device and the LNA circuit. Different process of the ionization damage and displacement damage under zero-bias and 2.5 V bias voltage supply contributed to the degradation difference. The underlying physical mechanisms are analyzed and investigated.

Effects of bacterial β-mannanase on apparent total tract digestibility of nutrients in various feedstuffs fed to growing pigs

  • Ki Beom Jang;Yan Zhao;Young Ihn Kim;Tiago Pasquetti;Sung Woo Kim
    • Animal Bioscience
    • /
    • v.36 no.11
    • /
    • pp.1700-1708
    • /
    • 2023
  • Objective: The objective of this study was to determine the effects of β-mannanase on metabolizable energy (ME) and apparent total tract digestibility (ATTD) of protein in various feedstuffs including barley, copra meal, corn, corn distillers dried grains with solubles (DDGS), palm kernel meal, sorghum, and soybean meal. Methods: A basal diet was formulated with 94.8% corn and 0.77% amino acids, minerals, and vitamins and test diets replacing corn-basal diets with barley, corn DDGS, sorghum, soybean meal, or wheat (50%, respectively) and copra meal or palm kernel meal (30%, respectively). The basal diet and test diets were evaluated by using triplicated or quadruplicated 2×2 Latin square designs consisting of 2 diets and 2 periods with a total of 54 barrows at 20.6±0.6 kg (9 wk of age). Dietary treatments were levels of β-mannanase supplementation (0 or 800 U/kg of feed). Fecal and urine samples were collected for 4 d following a 4-d adaptation period. The ME and ATTD of crude protein (CP) in feedstuffs were calculated by a difference procedure. Data were analyzed using Proc general linear model of SAS. Results: Supplementation of β-mannanase improved (p<0.05) ME of barley (10.4%), palm kernel meal (12.4%), sorghum (6.0%), and soybean meal (2.9%) fed to growing pigs. Supplementation of β-mannanase increased (p<0.05) ATTD of CP in palm kernel meal (8.8%) and tended to increase (p = 0.061) ATTD of CP in copra meal (18.0%) fed to growing pigs. Conclusion: This study indicates that various factors such as the structure and the amount of β-mannans, water binding capacity, and the level of resistant starch vary among feedstuffs and the efficacy of supplemental β-mannanase may be influenced by these factors.

Differences in facial soft tissue deviations in Class III patients with different types of mandibular asymmetry: A cone-beam computed tomography study

  • Ho-Jin Kim;Hyung-Kyu Noh;Hyo-Sang Park
    • The korean journal of orthodontics
    • /
    • v.53 no.6
    • /
    • pp.402-419
    • /
    • 2023
  • Objective: This study assessed the differences in soft tissue deviations of the nose, lips, and chin between different mandibular asymmetry types in Class III patients. Methods: Cone-beam computed tomography data from 90 Class III patients with moderate-to-severe facial asymmetry were investigated. The sample was divided into three groups based on the extent of mandibular rolling, yawing, and translation. Soft tissue landmarks on the nose, lips, and chin were investigated vertically, transversely, and anteroposteriorly. A paired t test was performed to compare variables between the deviated (Dv) and nondeviated (NDv) sides, and one-way analysis of variance with Tukey's post-hoc test was performed for intergroup comparisons. Pearson's correlation coefficient was calculated to assess the relationship between the soft and hard tissue deviations. Results: The roll-dominant group showed significantly greater differences in the vertical positions of the soft tissue landmarks between the Dv and NDv than other groups (P < 0.05), whereas the yaw-dominant group exhibited larger differences in the transverse and anteroposterior directions (P < 0.05). Moreover, transverse lip cant was correlated with the menton (Me) deviation and mandibular rolling in the roll-dominant group (P < 0.001); the angulation of the nasal bridge or philtrum was correlated with the Me deviation and mandibular yawing in the yaw-dominant group (P < 0.01). Conclusions: The three-dimensional deviations of facial soft tissue differed based on the mandibular asymmetry types in Class III patients with similar amounts of Me deviation. A precise understanding of soft tissue deviation in each asymmetry type would help achieve satisfactory facial esthetics.

A Full Scale Fossil Power Plant Simulator For Hadong (하동 화력 발전소 전범위 시뮬레이터 개발)

  • 김성호;김종현;조창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.204-204
    • /
    • 2000
  • This paper describes the development of training simulator for Hadong fossil Power Plant. The simulator was developed to train operator, test new control Logic and evaluate alternative operating procedure for expert engineer of control system. The most control logics such as Siemens TELEPERM ME and GE Mark V are translated directly from microprocessors. Those HMI are also directly emulated. The simulation was performed by ProTRAX modeling software. The paper discusses the configuration of simulator and the simulation results of 30%, 50%, 75% and 100% normal rate load test.

  • PDF

Evaluation of X-ray System for Nondestructive Testing on Radioactive Waste Drums (방사성폐기물 드럼 비파괴 검사를 위한 X-ray 장비 평가)

  • Park, Jong-Kil;Maeng, Seong-Jun;Lee, Yeon-Ee;Hwang, Tae-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.189-203
    • /
    • 2008
  • The physical and chemical properties of radioactive waste drums, which have been temporarily stored on site, should be characterized before their shipment to a disposal facility in order to prove that the properties meet the acceptance guideline. The investigation of NDT(Nondestructive Test) method was figured out that the contents in drum, the quantitative analysis of free standing water and void fraction can be examined with X-ray NDT techniques. This paper describes the characteristics of X-ray NDT such as its principles, the considerations for selection of X-ray system, etc. And then, the waste drum characteristics such as drum type and dimension, contents in drum, etc. were examined, which are necessary to estimate the optimal X-ray energy for NDT of a drum. The estimation results were that: $(R)\acute{A}$ the proper X-ray energy is under 3 MeV to test the drums of 320 ${\beta}\S$ and less; $(R)\ddot{E}$ both X-ray systems of 450 keV and/or 3 MeV might be needed considering the economical efficiency and the realization. The number of drums that can be tested with 450 keV and 3 MeV X-ray system was figured out as 42,327 and 18,105 drums (based on storage of 2006. 12), respectively. Four testing scenarios were derived considering equipment procurement method, outsourcing or not, etc. The economical and feasibility assessment for the scenarios was resulted in that an optimal scenario is dependent on the acceptance guide line, the waste generator's policy on the waste treatment and the delivery to a disposal facility, etc. For example, it might be desirable that a waste generator purchases two 450 keV mobile system to examine the drums containing low density waste, and that outsourcing examination for the high density drums, if all NDT items such as quantitative analysis for 'free standing water' and 'void fraction', and confirmation of contents in drum have to be characterized. However, one 450 keV mobile system seems to be required to test only the contents in 13,000 drums per year.

  • PDF

Comparison of longitudinal treatment effects with facemask and chincup therapy followed by fixed orthodontic treatment on Class III malocclusion (상악전방견인장치와 이모장치 및 고정식 교정장치 치료를 받은 III급 부정교합 환자의 치료효과에 대한 종단적 비교)

  • Lee, Nam-Ki;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.362-371
    • /
    • 2009
  • Objective: The purpose of this study was to compare the longitudinal treatment effects of facemask with rapid maxillary expansion (FM/RME) and chincup (CC) therapy followed by fixed orthodontic treatment (FOT) in Class III malocclusion (CIII) patients. Methods: The samples consisted of twenty-one CIII patients who had similar skeletal and dental characteristics before FM/RME or CC therapy and good retention results (Class I molar/canine relationship and positive overbite/overjet) after FOT (Group 1, FM/RME, n = 11; Group 2, CC, n = 10). Lateral cephalograms were taken before (T0) and after FM/RME or CC therapy (T1), and after FOT and retention (T2). Skeletal and dental variables were measured. Mann-Whitney U-test and Wilcoxon signed-rank test were used for statistical analysis. Results: During T0-T1, FM/RME therapy induced forward movement of point A, and labioversion of the upper incisors. Both groups showed posterior repositioning of the mandible. FM/RME resulted in increase of the vertical dimension; however, CC caused an increase in articular angle and decrease in gonial angle. During T1-T2, both groups exhibited forward growth of point A. Group 1 showed forward growth and counterclockwise rotation of the mandible and increase of IMPA; however, Group 2, showed increase of ANS-Me/N-Me and decrease of overbite. Conclusions: The key factor for successful FM/RME and CC therapy and good retention results might be a harmonized forward growth of the maxilla that could keep pace with the growth and rotation of the mandible.

The Removal of Carbon-14 Scrubber for Removal of Environmental Radioactive Carbon in a Heavy Water Reactor (중수로 환경방출 방사성이산화탄소 제거 장치 개발)

  • 강덕원;지준화;엄희문
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.509-513
    • /
    • 2003
  • The radioactive Carbon, C-14, although present in small amount, emits a high energy(up to 0.156MeV) $\beta$ ray and has extremely long half-life(5730years). So special monitoring and management on its generation and discharge is inevitable. A PHWR, due to its own specific designs generates about six times as much C-14 as a PWR does and over 90% of the discharged C-14 comes from the Moderator system and discharged in to the environment through the process of periodic purging of the moderator cover gas system. The present study focussed on the development of effective C-14 scrubber and after production of a test facility and experiments using it, we found that our test facility is very efficient in $CO_2$ removal.

  • PDF

Proton induced Effects on Commercial Single-mode Optical Fibers (상용 단일모드 광섬유의 양성자 영향)

  • Kim, Jong-yeol;Kim, Young-woong;Ryu, Guk-been;Hwang, Young-gwan;Lee, Min-Woong;Song, Keun-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.623-625
    • /
    • 2022
  • In this paper, the proton induced attenuation characteristics were evaluated for 5 types of commercial single-mode optical fibers using a proton accelerator. The proton beam used in the irradiation test has a high energy of 100 MeV class, and the test was performed by setting the uniformity of the beam irradiation area to 10% or less. According to the type of optical fiber (internal material, impurities), the radiation induced attenuation by the proton irradiation showed a noticeable difference.

  • PDF