• 제목/요약/키워드: MDL

검색결과 159건 처리시간 0.025초

Reversible Data Hiding Using a Piecewise Autoregressive Predictor Based on Two-stage Embedding

  • Lee, Byeong Yong;Hwang, Hee Joon;Kim, Hyoung Joong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.974-986
    • /
    • 2016
  • Reversible image watermarking, a type of digital data hiding, is capable of recovering the original image and extracting the hidden message with precision. A number of reversible algorithms have been proposed to achieve a high embedding capacity and a low distortion. While numerous algorithms for the achievement of a favorable performance regarding a small embedding capacity exist, the main goal of this paper is the achievement of a more favorable performance regarding a larger embedding capacity and a lower distortion. This paper therefore proposes a reversible data hiding algorithm for which a novel piecewise 2D auto-regression (P2AR) predictor that is based on a rhombus-embedding scheme is used. In addition, a minimum description length (MDL) approach is applied to remove the outlier pixels from a training set so that the effect of a multiple linear regression can be maximized. The experiment results demonstrate that the performance of the proposed method is superior to those of previous methods.

Combined Isobutoxycarbonylation and tert-Butyldimethylsilylation for the GC/MS-SIM Detection of Alkylphenols, Chlorophenols and Bisphenol A in Mackerel Samples

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • 제26권9호
    • /
    • pp.697-705
    • /
    • 2003
  • The alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) followed by two work-up methods for comparison: isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. Eleven endocrine disrupting chemicals (EDCs) of phenols in biological samples were extracted with acetonitrile and then the acetonitrile layer underwent freezing filtration 6$0^{\circ}C$ for 2 hours. Solid-phase extraction (SPE) was used with XAD-4 and subsequent conversion to isoBOC or TBDMS derivatives for sensitivity analysis with the GC/MS-SIM mode. For isoBOC derivatization and TBDMS derivatization the recoveries were 92.3∼150.6% and 93.8∼108.3%, the method detection limits (MDLs) of bisphenol A for SIM were 0.062 $\mu$ g/kg and 0.010 $\mu$ g/kg, and the SIM responses were linear with the correlation coefficient varying by 0.9755∼0.9981 and 0.9908∼0.9996, respectively. When these methods were applied to mackerel samples, the concentrations of the 11 phenol EDCs were below the MDL.

5-HT1A receptors mediate the analgesic effect of rosavin in a mouse model of oxaliplatin-induced peripheral neuropathic pain

  • Li, Daxian;Park, Sangwon;Lee, Kyungjoon;Jang, Dae Sik;Kim, Sun Kwang
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제25권5호
    • /
    • pp.489-494
    • /
    • 2021
  • Oxaliplatin, a third-generation platinum derivative, is the mainstay of current antineoplastic medications for advanced colorectal cancer therapy. However, peripheral neuropathic complications, especially cold allodynia, undermine the life-prolonging outcome of this anti-cancer agent. Rosavin, a phenylpropanoid derived originally from Rhodiola rosea, exhibits a wide range of therapeutic properties. The present study explored whether and how rosavin alleviates oxaliplatin-induced cold hypersensitivity in mice. In the acetone drop test, cold allodynia behavior was observed from days 3 to 5 after a single injection of oxaliplatin (6 mg/kg, i.p.). Cold allodynia was significantly attenuated following rosavin treatment (10 mg/kg, i.p.). Specific endogenous 5-HT depletion by three consecutive pretreatments with parachlorophenylalanine (150 mg/kg/day, i.p.) abolished the analgesic action of rosavin; this effect was not observed following pretreatment with naloxone (opioid receptor antagonist, 10 mg/kg, i.p.). Furthermore, 5-HT1A receptor antagonist WAY-100635 (0.16 mg/kg, i.p.), but not 5-HT3 receptor antagonist MDL-72222 (1 mg/kg, i.p.), blocked rosavin-induced analgesia. These results suggest that rosavin may provide a novel approach to alleviate oxaliplatin-induced cold allodynia by recruiting the activity of 5-HT1A receptors.

2008년과 2010년 지정 VOC 계열 신규악취성분들에 대한 분포특성 조사: 도심 하수환경 중 빗물받이에 대한 연구 (Measurements of Volatile Organics, Newly Designated Offensive Odorants in Korea in 2008 and 2010: a Case Study on Gutter System)

  • 안지원;홍원필;이은희;김기현
    • 한국대기환경학회지
    • /
    • 제26권3호
    • /
    • pp.305-317
    • /
    • 2010
  • In this research, a total of 11 newly designated offensive odorants in Korea in 2008 and 2010 (styrene (S), toluene (T), p-xylene (p-X), methyl ethyl ketone (MEK), methyl isobutyl ketone (MIBK), butyl acetate (BuAc), isobutyl alcohol (i-BuAl), propionic acid (PA), butyric acid (BA), isovaleric acid (IA), and valeric acid (VA)) were selected as target compounds and analyzed from two types of gutter system in the urban environment. Because of the environmental significance of these compounds as offensive odorants, the results are meaningful enough to explore their behavior and distribution in the urban environmental systems. In the course of this study, samples were collected three times a day from two different gutter systems representing the wet (W) and dry (D) conditions. A large fraction of volatile organic compounds (VOCs) data fell into method detection limit (MDL) range with exceptions of toluene, p-xylene, and methyl ethyl ketone. In contrast, the results of organic fatty acids were distinguished by the relative dominance of butyric acid and propionic acid over others. If the concentration data of all odorants were converted into odor intensity (OI), the results of aromatics, ketones, acetate, and alcohol groups approached zero level. However, odor intensity of organic fatty acids was noticeably higher with the value of 2.8 (on average) from both W and D system, suggesting their potent roles as odorants in gutter system.

Distribution of Airborne Hexavalent Chromium Concentrations in Large Industrial Complexes in Korea

  • Kang, Byung-Wook;Lee, Hak-Sung;Kim, Jong-Ho;Hong, Ji-Hyung;Kim, Rok-Ho;Seo, Young-Kyo;Han, Jin-Seok;Baek, Kyung-Min;Kim, Min-Ji;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권4호
    • /
    • pp.208-216
    • /
    • 2016
  • This paper reports the results of a field evaluation which used sampling and analytical methods to determine the levels of airborne hexavalent chromium Cr(VI) in major industrial complexes in Korea over a seven year period (2007-2013). Cr(VI) concentrations were determined using cellulose filter sampling and ion chromatography analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control (QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of Cr(VI) for the nine industrial complexes in Korea were in the range of 0.09 to $1.40ng/m^3$, which is similar to of the concentrations in other industrial areas around the world. The impacts of Cr(VI) emissions from industrial areas on Cr(VI) concentrations in neighboring-residential areas were considerably low, and the dispersion of Cr(VI) from industrial areas to residential areas was estimated to be 'not-significant'. Cr(VI) levels were not affected by seasonal variation, which suggests that chromium was emitted continuously from the industrial sources throughout the year. The concentration of Cr(VI) measured accounted for 0.7 to 9.4 percent of the total chromium level, which is a low percentage compared to those in other urban areas around the world. This is the first report in an international journal of a field study conducted in Korea to determine the concentration of Cr(VI) in the ambient air of industrial and residential areas.

DNPH cartridge/LC-MS 방법에 의한 반월.시화산업단지의 폼알데하이드 분석에 관한 연구 (Analysis of formaldehyde using DNPH cartridge/LC-MS in the Ban-Woll.Shi-Hwa Industrial Complex)

  • 조덕희;송일석;김인구;김웅수;김종보;김태현;황선민;남우경
    • 환경위생공학
    • /
    • 제21권1호
    • /
    • pp.35-43
    • /
    • 2006
  • Formaldehyde is important because of their irritant and toxic properties, mutagenicity and carcinogenicity. In this study, liquid chromatography-mass spectrometry (LC-MS) is used for the analysis of formaldehyde after derivatization with 2,4-dinitrophenylhydrazine (DNPH) cartridge. Analytical parameters such as linearity, repeatability and minimum detection limit were evaluated. The linearity ($r^2$) was 0.9997 when analyte concentration ranges from 25 to $200{\mu}g/l$. The relative standard deviation (%RSD) was 1.25 % for concentration of $200{\mu}g/l$. The minimum detection limit (MDL) was 0.73 ppbv. It was shown that LC-MS method has a great potential for formaldehyde analysis. The results of formaldehyde from the survey of Ban-Woll and Shi-Hwa Industrial Complex samples, the highest level was 6.20, 3.93 ppb, respectively. The highest emission level of formaldehyde at chemical plants in the Ban-Woll' Shi-Hwa Industrial Complex was 5421.25 ppb.

4-Way 캐쉬의 선택된 Element를 이용한 향상된 동적 분기 예측기 구현 (An Improved Dynamic Branch Predictor by Selective Access of a Specific Element in 4-Way Cache)

  • 황인성;황선영
    • 한국통신학회논문지
    • /
    • 제38A권12호
    • /
    • pp.1094-1101
    • /
    • 2013
  • 본 논문은 4-Way 캐쉬의 선택된 element만을 사용하여 어플리케이션 수행 사이클을 줄인 향상된 동적 분기 예측기를 제안한다. 제안된 동적 분기 예측기는 분기명령어가 페치되면 MRU 버퍼를 참조하여 4-Way 캐쉬의 선택된 element에서 타깃 주소를 얻으므로, 모든 element에 접근하는 기존의 동적 분기 예측기보다 제한된 전력하에서 BTAC entry 수를 증가시킬 수 있어 분기 예측 성공률과 어플리케이션의 수행속도가 상당히 향상된다. 제안된 동적 분기 예측기의 효율성을 SMDL 시스템에 의해 생성된 코어가 벤치마크 어플리케이션을 수행하여 검증한다. 실험결과 동적 분기 예측기가 없는 코어에 비해 생성된 코어의 어플리케이션 수행 사이클은 평균 10.1% 감소하고 어플리케이션의 전력소모는 7.4% 증가한다. 기존 동적 분기 예측기를 사용하는 코어에 비해 수행 사이클은 평균 4.1% 줄어든다.

Determination of trace bromate in various water samples by direct-injection ion chromatography and UV/Visible detection using post-column reaction with triiodide

  • Kim, Jungrae;Sul, Hyewon;Song, Jung-Min;Kim, Geon-Yoon;Kang, Chang-Hee
    • 분석과학
    • /
    • 제33권1호
    • /
    • pp.42-48
    • /
    • 2020
  • Bromate is a disinfection by-product generated mainly from the oxidation of bromide during the ozonation and disinfection process in order to remove pathogenic microorganism of drinking water, and classified as a possible human carcinogen by International Agency for Research of Cancer (IARC) and World Health Organization (WHO). For the purpose of determining the trace level concentration of bromate, several sensitive techniques are applied mostly based on suppressed conductivity detection and UV/Visible detection after postcolumn reaction (PCR). In this study, the suppressed conductivity detection method and the PCR-UV/Visible detection method through the triiodide reaction were compared to analyze the trace bromate in water samples and estimated for the availability of these analytical methods. In addtion, the state-of-the-art techniques was applied for the determination of trace level bromate in various water matrices, i.e., soft drinking water, hard drinking water, mineral water, swimming pool water, and raw water. In comparison of two analytical methods, it was found that the conductivity detection had the suitable advantage to simultaneously analyze bromate and inorganic anions, however, the bromate might not be precisely quantified due to the matrix effect especially by chloride ion. On the other hand, the trace bromate was analyzed effectively by the method of PCR-UV/Visible detection through triiodide reaction to satisfactorily minimize the matrix interference of chloride ion in various water samples, showing the good linearity and reproducibility. Furthermore, the method detection limit (MDL) and recovery were 0.161 ㎍/L and 101.0-108.1 %, respectively, with a better availability compared to conductivity detection.

흡착튜브 - 열탈착 정량분석 기법에 기반한 과일시료로부터 자연적 휘발성유기화합물의 배출특성 연구 (Biogenic Volatile Organic Compounds (BVOC) Emissions from Fruit Samples Based on Sorbent Tube Sampling and Thermal Desorption (ST-TD) Analysis)

  • 안정현;김기현
    • 한국대기환경학회지
    • /
    • 제29권6호
    • /
    • pp.757-772
    • /
    • 2013
  • In this study, a combination of sorbent tube (ST)-thermal desorption (TD)-gas chromatography (GC)-mass spectrometry (MS) was used for quantitative analysis of liquid phase standards of 10 BVOC ((1) (+)-${\alpha}$-pinene, (2) (+)-${\beta}$-pinene, (3) ${\alpha}$-phellandrene, (4) (+)-3-carene, (5) ${\alpha}$-terpinene, (6) p-cymene, (7) (R)-(+)-limonene, (8) ${\gamma}$- terpinene, (9) myrcene, and (10) camphene). The results of BVOC calibration yielded comparatively stable pattern with response factor (RF) of 23,560~50,363 and coefficient of determination ($R^2$) of 0.9911~0.9973. The method detection limit (MDL) of BVOC was estimated at 0.03~0.06 ng with the reproducibility of 1.30~5.13% (in terms of relative standard error (RSE)). Emissions of BVOC were measured from four types of fruit samples ((1) tangerine (TO), (2) tangerine peel (TX), (3) strawberry (SO), and (4) sepals of strawberry (SX)). The sum of BVOC flux (${\sum}flux$ (BVOC) in ng/hr/g) for each sample was seen on the descending order of (1) TX=291,614, (2) TO=2,190, (3) SO=1,414, and (4) SX=2,093. If the results are compared between the individual components, the highest flux was seen from (R)-(+)-limonene (265,395 ng/hr/g) from TX sample.

LC/MS/MS 분석을 위한 microcystins 전처리 단계별 효율성 연구 (Evaluation of Pre-treatment Stages for Microcystins Analysis using LC/MS/MS)

  • 김화빈;박혜경;문정숙
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.720-726
    • /
    • 2009
  • We investigated the most effective pre-treatment processes and LC/MS/MS condition for microcystins analysis. With a step-by-step pre-treatment, efficiencies of several established methods were compared. At the level of cell burst, sonication method was found to be the most efficient. As a mycrocystins first extraction solvent, 5% acetic acid showed the highest efficiency. An isolation and recovery rate of mycrocystins of ODS Sep-Pak $C_{18}$ cartridge was higher than HLB SPE cartridge. As a final elution solvent from cartridge, 100% MeOH had a better efficiency than others. Using a LC/MS/MS, effective analytical methods were established. C18 reverse column was used and gradient elution was performed with using acetonitrile, 0.1% formic acid as a mobile phase. We analysed to 0.8 mL/min flow rate fit to the $5{\mu}m$ particle size column and $55^{\circ}C$ housing temperature. The validity of established analytical method was evaluated that MDL as average $0.050{\pm}0.014{\mu}g/L$ and LOQ as average $0.160{\pm}0.045{\mu}g/L$ had a good sensitivity over 40 magnification rather than $2{\mu}g/L$ detection limit of HPLC.