• 제목/요약/키워드: MCG

검색결과 160건 처리시간 0.022초

LONG-TERM X-RAY VARIABILITIES OF THE SEYFERT GALAXY MCG-2-58-22 : SECULAR FLUX DECREASE AND FLARES

  • CHOI CHUL-SUNG;DOTANI TADAYASU;CHANG HEON- YOUNG;YI INSU
    • 천문학회지
    • /
    • 제35권1호
    • /
    • pp.1-7
    • /
    • 2002
  • We have studied the long-term X-ray light curve (2-10 keV) of the luminous Seyfert 1 galaxy MCG-2-58-22 by compiling data, from various X-ray satellites, which together cover more than 20 years. We have found two distinct types of time variations in the light curve. One is a gradual and secular decrease of the X-ray flux, and the other is the episodic increase of X-ray flux (or flare) by a factor of 2-4 compared with the level expected from the secular variation. We detected 3 such flares in total; a representative duration for the flares is $\~$2 years, with intervening quiescent intervals lasting $\~$6-8 years. We discuss a few possible origins for these variabilities. Though a standard disk instability theory may explain the displayed time variability in the X-ray light curve, the subsequent accretions of stellar debris, from a tidal disruption event caused by a supermassive black hole in MCG-2-58-22, cannot be ruled out as an alternative explanation.

웨이브릿 변환을 기반으로 한 심자도 신호의 국소 적응잡음제거 (Local Adaptive Noise Cancellation for MCG Signals Based on Wavelet Transform)

  • 김용주;박희준;원철호;이용호;김인선;김명남;조진호
    • Progress in Superconductivity
    • /
    • 제5권1호
    • /
    • pp.26-30
    • /
    • 2003
  • Magneto-cardiogram(MCG) signals may be highly distorted by the environmental noise, such as power-line interference, broadband white noise, surrounding magnetic noise, and baseline wondering. Several kinds of digital filters and noise cancellation methods have been designed and realized by many researchers, but these methods gave some problems that the original signal may be distorted by digital filter due to the wideband characteristics of background noise. To eliminate noise effectively without distortion of MCG signals, we performed multi-level frequency decomposition using wavelet packets and local adaptive noise cancellation in each local frequency range. In addition to the proposed wavelet filter to eliminate these various non-stationary noise elements, the local adaptive filter using the least mean square(LMS) algorithm and the soft threshold do-noising method are introduced in this paper. The signal to noise ratio(SNR) and the reconstruction square error(RSE) are calculated to evaluate the performance of the proposed method and compared with the results of the conventional wavelet filter and adaptive filter. The experimental results show that the proposed local adaptive filtering method is better than the conventional methods.

  • PDF

The latest trend in magnetocardiogram measurement system technology

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.1-5
    • /
    • 2020
  • Heart consists of myocardium cells and the electrophysiological activity of the cells generate magnetic fields. By measuring this magnetic field, magnetocardiogram (MCG), functional diagnosis of the heart diseases is possible. Since the strength of the MCG signals is weak, typically in the range of 1-10 pT, we need sensitive magnetic sensors. Conventionally, superconducting quantum interference devices (SQUID)s were used for the detection of MCG signals due to its superior sensitivity to other magnetic sensors. However, drawback of the SQUID is the need for regular refill of a cryogenic liquid, typically liquid helium for cooling low-temperature SQUIDs. Efforts to eliminate the need for the refill in the SQUID system have been done by using cryocooler-based conduction cooling or use of non-cryogenic sensors, or room-temperature sensors. Each sensor has advantage and disadvantage, in terms of magnetic field sensitivity and complexity of the system, and we review the recent trend of MCG technology.

열린 자기차폐실의 심자도 시스템 (Magnetocardiography System in Open-door Magnetically-shielded Room)

  • 김진목;이용호;권혁찬;유권규;김기웅;박용기
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.50-55
    • /
    • 2007
  • We have installed a 61-channel magnetocardiography (MCG) system inside a magnetically shielded room (MSR) with a size of $2.4\;m\;{\times}2.4\;m\;{\times}2.4\;m$. The MCG system consists of 1st-order axial gradiometers containing double relaxation oscillation SQUIDs (DROSs) with pick-up coils of a base line of 70 mm. The MSR holds a shielding factor of 50 at 0.1 Hz and 10000 at 100 Hz, when its door in the middle on a front wall is closed. On opening the MSR door, we have obtained the characteristics of the MCG system with a 2.9 Hz noise generated from an air conditioning unit at 13 m distance off the MSR. In an open-door MSR ($140^{\circ}$ opening), a noise at the center channel increases up to $700\;fT/Hz^{l/2}$ at 2.9 Hz and $1.7\;pT/Hz^{1/2}$ at 60 Hz. MCG signals for a healthy human do not show distortion until the door opens to $45^{\circ}$, but show the effect of noise when the door opens further at $90^{\circ}$ and $140^{\circ}$. With the door opens to $45^{\circ}$, MCG measurement can be performed with ease of door operation and without creating claustrophobia for the patient.

  • PDF

관상동맥질환 진단을 위한 심자도맵의 분류 방법 (Classification of magnetocardiographic maps in coronary artery disease diagnosis)

  • 권혁찬;김기웅;김진목;이용호;김태은;임현균;고영국;정남식
    • Progress in Superconductivity
    • /
    • 제7권1호
    • /
    • pp.41-45
    • /
    • 2005
  • The diagnostic management of patients with chest pain remains a clinical challenge. Magnetocardiography (MCG) has been proposed as a new non-invasive method for detection of myocardial ischemia. To date, however, MCG technique is not intensively introduced for clinical use. One of the main reasons might be the absence of statistically valid and diagnostically clean criteria, which can determine the presence of certain heart disease. In this work, we suggested a new method to classify the diagnostic value of MCG for the detection of coronary artery disease (CAD) in patients with chest pain. MCG was recorded for three groups (healthy subjects and patients without and with CAD) by means of the 64 channel SQUID gradiometer system installed at a hospital. Using four parameters, which were found to be significantly different between groups, we evaluated a probability, in which parameters can be classified into each group based on the distribution function of the parameter in each group. For all parameters, sum of probabilities was compared between groups to determine the presence of CAD. Our classification method shows that the MCG can be a useful tool to predict the presence of CAD with sensitivity and specificity of higher than $80\%$ each.

  • PDF

응급실에서 심자도의 역할 (Role of Magnetocardiography in Emergency Room)

  • 권혁찬;김기웅;김진목;이용호;김태은;임현균;박용기;고영국;정남식
    • Progress in Superconductivity
    • /
    • 제8권1호
    • /
    • pp.40-45
    • /
    • 2006
  • In emergency rooms, patients with acute chest pain should be diagnosed as quickly as possible with higher diagnostic accuracy for an appropriate therapy to the patients with acute coronary syndrome or for avoiding unnecessary hospital admissions. At present, electrocardiography(ECG) and biochemical markers are generally used to detect myocardial infarction and coronary angiography is used as a gold standard to reveal the degree of narrowing of coronary artery. Magnetocardiography(MCG) has been proposed as a novel and non-invasive diagnostic tool fur the detection of cardiac electrical abnormality associated with myocardial ischemia. In this study, we examined whether the MCG can be used fur the detection of coronary artery disease(CAD) in patients, who were admitted to the emergency room with acute chest pain. MCG was recorded from 36 patients admitted to the emergency room with suspected acute coronary syndrome. The MCG recordings were obtained using a 64-channel SQUID MCG system in a magnetically shielded room. In result, presence of CAD could be found with a sensitivity of 88.2 % in patients with acute chest pain without 57 elevation in ECG, demonstrating a possible use in the emergency room to screen CAD patients.

  • PDF

DROS 자력계의 동작특성 및 심자도 측정 (The characteristics of DROS magnetometer and MCG measurement)

  • 강찬석;이용호;권혁찬;김진목;유권규;박용기;이순걸
    • Progress in Superconductivity
    • /
    • 제8권2호
    • /
    • pp.164-168
    • /
    • 2007
  • We developed a SQUID magnetometer based on Double Relaxation Oscillation SQUID(DROS) for measuring magnetocardiography(MCG). Since DROS provides a 10 times larger flux-to-voltage transfer coefficient than the conventional DC-SQUID, simple flux-locked loop electronics could be used for SQUID operation. Especially, we adopted an external feedback to eliminate the magnetic coupling with adjacent channels. When the DROS magnetometer was operated inside a magnetically shielded room, average magnetic field noise was about 5 $fT/^{\surd}Hz$ at 100 Hz. Using the DROS magnetometer, we constructed a multichannel MCG system. The system consisted of 61 magnetometers are arranged in a hexagonal structure and measures a vertical magnetic-field component to the chest surface. The distance between adjacent channels is 26 mm and the magnetometers cover a circular area with a diameter of 208 mm. We recorded the MCG signals with this system and confirmed the magnetic field distribution and the myocardinal current distribution.

  • PDF

연맥 사일리지에서 분리된 Lactobacillus plantarum의 균특성에 관한 연구 (Studies on the characteristics of Lactobacillus plantarum isolated from oat silage)

  • 정종율;임영택;석호봉
    • 대한수의학회지
    • /
    • 제40권2호
    • /
    • pp.325-332
    • /
    • 2000
  • The growth characteristics and the cellular protein patterns of the Lactobacillus plantarum isolated and identified from oat silage were examined in order to confirm whether it will be used practically as probiotics or not. L plantarum was identified by morphological and biochemical tests including of final conforming by API 50CHL kit. The cultivation in MRS broth of the strain under the condition of different temperature, proved that they grew into $2.0{\times}10^{9}$ in $25^{\circ}C$, into $1.4{\times}10^{9}$ in $35^{\circ}C$ but they decreased into $4.5{\times}10^{5}$ growth in $45^{\circ}C$. The comparison of the growth by measurement of O.D600nm value after 24 hour cultivation between L plantarum and commercial probiotics, showed that the strain had a higher growth than commercial as 1.841 : 1.623. The measurement of it under bile acid's existence, indicated that this isolation was not influenced by bile acid and the tolerance was $3.2{\times}10^{9}$, $3.9{\times}10^{9}$ and $3.2{\times}10^{9}$, respectively, when each of 0%, 1%, and 2% oxigall existed. The examination of their antibiotics susceptibility by disk diffusion test, proved that L plantarum showed resistance against danofloxacin(5mcg), gentamycin(10mcg), kanamycin(30mcg), neomycin(30mcg) and streptomycin(10mcg). Based upon the test of the bacteriocin formation of this L plantarum, it was found out that the inhibition zone was not formed. In growth of L plantarum and E coli in nutrient broth, all E coli died out within 6 hours after cultures.

  • PDF