• Title/Summary/Keyword: MCCB

Search Result 93, Processing Time 0.032 seconds

Improvement of Short Circuit Performance in 460[V]/400[A]/85[kA] Molded Case Circuit Breakers (460[V]/400[A]/85[kA] 배선용 차단기의 그리드 및 아크런너 변형을 통한 차단성능 향상)

  • Lee, Seung-Su;Jung, Eui-Hwan;Yoon, Jae-Hun;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1451_1452
    • /
    • 2009
  • Owing to the increasing number of intelligent homes(or called Smart home), the corresponding cost is much higher. Low voltage circuit breakers are widely used in the intelligent homes to interrupt fault current rapidly and to assure the reliability of the power supply. The distribution of magnetic field induced by arc current in the contact system of molded case circuit breaker depends on the shape, arrangement, and kinds of material of grids. This paper is focused on understanding the interrupting capability, more specifically of the grid and the arc runner, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF

Qualitative Assessment for Hazard on the Electric Power Installations of a Construction Field using FMEA (FMEA를 이용한 건설현장 전력설비의 위험성에 대한 정성적 평가)

  • Kim Doo-hyun;Lee Jong-ho
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.36-41
    • /
    • 2004
  • This paper presents an qualitative assessment for hazard on the electric power installations of a construction field using FMEL The power installations have the mission to maintain the highest level of service reliability on the works. The more capital the electric power invest the higher service reliability they plausibly will achieve. However, because of limited resources, how effectively budgets can be allocated to achieve service reliability as high as possible. The assessment typically generates recommendations for increasing component reliability, thus improving the power installation safety. The FMEA tabulates the failure modes of components and how their failure affects the power installations being considered. Tn order to estimate the risks of a failures, the FMEA presents criticality estimation or risk priority number using the severity, occurrence, and detectability. The results showed that the highest components of the risk priority number among components were condenser, transformer, MCCB and LA. And In case of the criticality estimation, the potential failure modes were abnormal temperature rise, insulation oil leakage, deterioration for the transformer, overcurrent for the MCCB and operation outage fir the LA.

Highly Sensitive Partial Discharge Sensor with Remote Monitoring Capabilities (원격감시 기능을 갖는 고감도 부분방전센서)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.349-356
    • /
    • 2015
  • Remote monitoring partial discharge sensor, equipping with hybrid filter combining optical and electrical noise reduction capabilities and with signal integrating function to calculate total arc energy, was investigated. Hybrid filter showed insensitivity to fluorescent and incandescent lamps under simulated distribution panel condition. Signal integrating function showed selective detection capability corresponding to different arc energy levels, while convention arc sensor had difficulty to discriminate arc energy level due to bursty arc waveform and peak level detection characteristics. The sensor showed possibility for application to remote monitoring partial discharge sensor, since it detected arc energy level corresponding to normal open and close discharge in low voltage 100A MCCB at 2m distance.

Methods for Increasing the Interrupting Performance of Are Chamber in 460V / 50KA / 100AF Molded Case Circuit Breaker (460V / 50KA / 100AF 급 배선용 차단기의 소호부 차단 성능 향상 방법)

  • Cho, Sung-Hoon;Jung, Eui-Hwan;Lee, Han-Ju;Lim, Kee-Joe;Kim, Kil-Sou
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.105-105
    • /
    • 2010
  • Voltage circuit breakers are widely used in power distribution systems to interrupt fault current rapidly and to assure the reliability of the power supply. Power distribution system requires the transformer with higher capacity than ever, but this ever, but this may be the cause. of the increasing of short circuit current in contrast to conventional one when short-circuit accident is occurred. Therefore molded case circuit breaker improved in aspects of interrupting capacity of short circuit current in this system is needed. By using the proposed methods in this paper, such as new arc quenching structure of grid would contribute to minimizing the MCCB, realization of high interrupting performance and reducing the design time and development cost.

  • PDF

Web-based Controlled Delivery and Consumption of Multimedia in MPEG-21 Framework

  • Hendry Hendry;Cha Kyung-Ae;Park Keunsoo;Kim Munchurl
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.43-46
    • /
    • 2004
  • MPEG-21 is an on-progress project of the Moving Picture Expert Group (MPEG) that has been started in many independent parts such as part for standardizing the declaration of a digital item (MPEG-21 Part 2: Digital Item Declaration), right expression language (MPEG-21 Part S: Rights Expression Language), way to process the digital item (MPEG-21 Part 10: Digital Item Processing), etc. All this part is intended to form a framework to enable transparent and augmented use of multimedia resources across a wide range of networks and devices (1). In this paper, we show our research initiative to develop a web-based application that utilized many parts of MPEG-21 technology. The implemented concept uses a digital item and license providers in the server side while the MPEG-21 Conformant application is implemented as a plug-in application that will be downloaded to the user terminal when user accesses the webpage for the frist time. The result of this research shows that with some combination of MPEG-21 parts, we can develop an authorized multimedia delivery and consumption application.

  • PDF

고조파에 의한 증성선 과전류 개선사례

  • Gang, Chang-Won;Lee, Jin-Seok
    • Electric Engineers Magazine
    • /
    • v.215 no.7
    • /
    • pp.17-21
    • /
    • 2000
  • Hook-On Meter로 중선선전류를 측정하면 큰 전류가 흘러 현장의 담당자를 어리둥절하게 만든다. 대부분의 기술자는 이 경우 누전에 의한 것이 아닌가 하는 의구심을 갖게 되나 실은 영상분 고조파에 의한 것임을 밝혀둔다. 최근 OA기기를 많이 쓰는 빌딩은 전부 이 문제를 가지고 있다. 이 영상분 고조파는 변압기, 케이블, MCCB 과열의 원인이 되고 대지전위상승 등 Noise 원으로 작용해 큰 피해가 우려된다

  • PDF

Change in Cognitive Function after Antipsychotics Treatment : A Pilot Study of Long-Acting Injectable versus Oral Form (항정신병약물 치료 후 인지기능 변화 차이 연구 : 장기 지속형 주사제와 경구제 비교의 예비 연구)

  • Sung, Kiyoung;Kim, Seoyoung;Kim, Euitae
    • Korean Journal of Schizophrenia Research
    • /
    • v.21 no.2
    • /
    • pp.74-80
    • /
    • 2018
  • Objectives : This study investigated whether long-acting injectable (LAI) paliperidone is different from its oral form in terms of the effect on cognitive function in schizophrenia spectrum and other psychotic disorders. Methods : We reviewed the medical records of patients in Seoul National University Bundang Hospital who were diagnosed as having schizophrenia and/or other psychotic disorders based on DSM-5 from 2016 to 2017. Seven patients were treated with oral paliperidone and 11 were treated with paliperidone palmitate. All patients underwent clinical and neuropsychological assessment, including the Korean version of the MATRICS Consensus Cognitive Battery (MCCB) at their first visit or within one month of their initial treatment. MCCB was repeated within three to 12 months after the initial assessment. Results : There was no significant difference between the two groups in most cognitive domains including speed of processing, attention and vigilance, working memory, verbal learning, visual learning and reasoning and problem solving domain. However, patients treated with paliperidone palmitate showed better improvement in social cognition domain than those taking oral paliperidone. The standardized values of social cognition domain scores had significantly improved over time in patients under paliperidone palmitate, demonstrating a significant time-by-group interaction. Conclusion : Our results show that long-acting injectable paliperidone could be helpful in some aspects of improving cognitive function in schizophrenia spectrum and other psychotic disorders. Further studies with other antipsychotics are necessary to generalize the results.

A Study on the Optimal Shape of Arc Chute for Molded Case Circuit Breakers (배선용 차단기 Arc Chute의 최적형상에 관한 연구)

  • Kim, J.S.;Lee, C.R.;Song, T.H.;Choi, M.J.;Kim, D.J.;Lee, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.926-928
    • /
    • 2002
  • Much progress has been made during the past two decades in numerical analysis of electromagnetic forces in molded case circuit breakers (MCCB) for increasing arc voltage due to the change of the configuration of arc chute and fixed conductor. A review on this topic is given. which mainly covers the past research activities associated with that of our company.

  • PDF

Failure Mode Analysis of Molded Case Circuit Breakers for the Reliability Assessment (배선용차단기의 신뢰성평가를 위한 고장모드해석)

  • Kim, Min-Kyu;Lee, Jeong-Gi;Jeong, Ju-Young;Kim, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1994-1996
    • /
    • 2004
  • 본 논문에서는 배전반 또는 분전반에서 널리 이용되고 있는 1000 V 이하의 배선용 차단기, 즉 MCCB(Molded Case Circuit Breakers)의 신뢰성을 평가하기 위한 시험계획 및 시험방법을 검토하기 위한 전단계에서 반드시 필요한 고장모드영향분석(FMEA)의 결과를 서술하고, 또한 고장모드별로 대응되는 스트레스를 이용한 신뢰성평가 방안에 대해서 제시한다.

  • PDF

신소호구조가 차단성능에 미치는 영향

  • Kim, Gil-Su;Lee, Seung-Su;Im, Gi-Jo;Gang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.227-227
    • /
    • 2009
  • To prevent such accidents, molded case circuit breakers with improved short-circuit current interrupting capacity are needed. This paper is focused on understanding the interrupting capability with respect to double contact structure and puffer assisted self quenching that are based on the shape of the contact system in the current molded case circuit breaker. The new arc quenching structure for increasing the interrupting capacity of molded case circuit breakers is investigated by simulation and experiment.

  • PDF