• Title/Summary/Keyword: MC method

Search Result 932, Processing Time 0.028 seconds

Research on the PAPR Reduction Method using Selection of Extra Code Set in PB/MC-CDMA System (PB/MC-CDMA 시스템에서 여분의 코드집합을 이용한 PAPR 감쇄기법에 관한 연구)

  • Lee, Kyu-Jin;Lee, Dong-Joon;Lee, Kye-San;Kim, Jin-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.1
    • /
    • pp.110-118
    • /
    • 2009
  • The PB/MC-CDMA(Partial Block Multi Carrier Code Division Multilple Access) system can improve the performance by reducing the ICI(Inter-Code Interference) between users. Also, this system can achieve the frequency diversity gain by avoiding ISI(Inter Symbol Interference). Therefore, the performance of PB/MC-CDMA system is better than that of conventional MC-CDMA(Multi Carrier Code Division Multiple Access) system. However, similarly to other multi-carrier systems, it still has a PAPR(Peak to Average Power Ratio) issue. In this paper, we propose a peak power reduction technique involving optimized spreading code selection without side information for the PB/MC-CDMA. The PB/MC-CDMA system in each block of units reuses the code so the extra code will be remained. This extra code is divided into several groups to calculate the PAPR and solving the PAPR problem by transferring the selected code which has minimum peak power.

  • PDF

Performance Analysis of Multicarrier Code Selection CDMA System for PAPR Reduction in Multipath Fading Channel (PAPR을 줄이기 위한 Multicarrier Code Select CDMA시스템의 다중 경로 페이딩 채널에서 성능 분석)

  • Ryu Kwan Woong;Park Yong Wan;Hong Een Kee;Kim Myovng Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.12A
    • /
    • pp.1319-1332
    • /
    • 2004
  • Multicarrier direct sequence code-division multiple access CDMA(MC DS-CDMA) is an attractive technique for achieving high data rate transmission even if the potentially large peak-to-average power ratio(PAPR) is an important factor for its application. On the other hand, code select CDMA(CS-CDMA) is an attractive technique with constant amplitude transmission of multicode signal irregardless of subchannels by introducing code selection method. In this paper we propose a new multiple access scheme based on the combination of MC DS-CDMA and CS-CDMA. Proposed scheme, which we called MC CS-CDMA, includes the sutclasses of MC DS-CDMA and CS-CDMA as special cases. The performance of this system is investigated for multipath Sequency selective fading channel and maximal ratio combining with rake receiver. In addition the PAPR of proposed system is compare with that of both MC BS-CDMA and CS-CDMA. Simulation results show that proposed system improves PAPR reduction than MC DS-CDMA at the expense of the complexity of receiver and the number of available non. Also, the numerical result shows that the proposed system is better performance than MC DS-CDMA due to the increasing processing gain and the number of time diversity gain.

Uncertainty Assessment Using Monte Carlo Simulation in Gas Flow Measurement (기체 유량 측정에서 몬테 카를로 모사를 이용한 측정불확도 평가)

  • Lee, Dae-Sung;Yang, In-Young;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1758-1765
    • /
    • 2003
  • Monte Carlo simulation(MC) method was used as an uncertainty assessment tool for gas flow measurement in this paper. Uncertainty sources for gas flow measurement were analyzed, and probability distribution characteristics of each source were discussed. Detailed MC methodology was described including the effect of the number of simulation. The uncertainty result was compared with that of the conventional sensitivity coefficient method, and it was revealed that the results were different from each other for this particular gas flow measurement case of which the modelling equation was nonlinear. The MC was comparatively simple, convenient and accurate as an uncertainty assessment method, especially in cases of complex, nonlinear measurement modelling equations. It was noted that the uncertainty assessment method should be selected carefully according to the mathematical characteristics of the measurement.

Performance Analysis of Dualrate MC-CDMA Systems Based on Code Grouping (코드그룹화에 의한 이중전송률 MC-CDMA 시스템의 성능분석)

  • Kim, Nam-Sun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.4
    • /
    • pp.112-120
    • /
    • 2006
  • Multicarrier code division multiple access(MC-CDMA) system that combines multicarrier modulation with CDMA offers robustness to frequency selective fading and can support higher rate data transmission with higher spectral efficiency. A new asynchronous MC-CDMA system to implement multiple data rate communications is proposed in this paper. In a W-CDMA downlink the orthogonal variable spreading factor(OVSF) code is used for variable spreading factor for various multimedia traffic. Proposed system utilizes the OVSF code that generated by generation property for spreading. The proposed MC-CDMA system use different lengths of OVSF code as a spreading code according to their data rate. The groupwise processing is accomplished by code grouping in OVSF code generation tree. For the analysis of average BER performance, numerical method and computer simulation were used. We also compare the system performance with that of a single rate MC-CDMA system used orthogonal code as a spreading code.

  • PDF

Comparison of Feature Selection Methods Applied on Risk Prediction for Hypertension (고혈압 위험 예측에 적용된 특징 선택 방법의 비교)

  • Khongorzul, Dashdondov;Kim, Mi-Hye
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.3
    • /
    • pp.107-114
    • /
    • 2022
  • In this paper, we have enhanced the risk prediction of hypertension using the feature selection method in the Korean National Health and Nutrition Examination Survey (KNHANES) database of the Korea Centers for Disease Control and Prevention. The study identified various risk factors correlated with chronic hypertension. The paper is divided into three parts. Initially, the data preprocessing step of removes missing values, and performed z-transformation. The following is the feature selection (FS) step that used a factor analysis (FA) based on the feature selection method in the dataset, and feature importance (FI) and multicollinearity analysis (MC) were compared based on FS. Finally, in the predictive analysis stage, it was applied to detect and predict the risk of hypertension. In this study, we compare the accuracy, f-score, area under the ROC curve (AUC), and mean standard error (MSE) for each model of classification. As a result of the test, the proposed MC-FA-RF model achieved the highest accuracy of 80.12%, MSE of 0.106, f-score of 83.49%, and AUC of 85.96%, respectively. These results demonstrate that the proposed MC-FA-RF method for hypertension risk predictions is outperformed other methods.

Biopharmaceutical Evaluation of Sustained-Release $Eudragit^{\circledR}$ Microcapsules Containing Cephalexin (서방성 $Cephalexin-Eudragit^{\circledR}$ 마이크로캅셀의 생물약제학적 평가)

  • Han, Kun;Kim, Kwang-Dug;Chung, Youn-Bok;Jee, Ung-Kil;Kim, Shin-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.2
    • /
    • pp.103-110
    • /
    • 1993
  • Microcapsules(Mc) of cephalexin (CEPH), using Eudragit RS, RL, L, S and polyethylene glycol 1540, were evaluated biopharmaceutically. The area under the curve of CEPH-Eudragit RS/RL Mc administered orally once was larger than that of cephalexin powder twice every 6 hrs. Controlledrelease effectiveness and the absorption rate effectiveness, two important parameters of Vallner's method, of CEPH-Eudragit RS/RL Mc indicate that these Mc can be good sustained-release preparations. And a simple pharmacokinetic model is introduced which allows the gastric emptying and intestinal-transit rates of a drug itself and a solid-state drug contained in Mc. Decreasing $K_r$, without change in $K_a$, showed that the rate-limiting step of absorption moved from absorption step to releasestep.

  • PDF

SPECTROPHOTOMETRIC ANALYSIS ON THE SEALING EFFECT OF ULTRASONIC OBTURATION OF THE ROOT CANAL (초음파(超音波) 근관충진법(根管充眞法)의 폐쇄효과(閉鎖效果)에 관(關)한 분광광도계(分光光度界) 측정(測定))

  • Kim, Yang-Lag
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.46-57
    • /
    • 1990
  • The purpose of this study was to spectrophotometrically investigate the sealing effect of the ultrasonic canal obturation with softened gutta-percha utilizing an endosonic plugger by means of ultrasonic vibrations and heat. The 120 extracted human central and lateral incisors with single root were randomly selected, and the root canals were instrumented up to size #60 file by conventional method. The prepared canals were obtruated with gutta-percha by lateral condensation method, McSpadden technique and ultrasonic condensation method, with or without sealer. All specimens were immersed in 2% methylene blue in an incubator at $37^{\circ}C$ for 10 days. The teeth were then dissolved in 5ml of 60% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data statistically evaluated usint two-way ANOVA and Student's t-test. The results were as follows : No statistically significant difference in leakage was observed between the lateral condensation method and ultrasonic condensation method, with and without sealer. When sealer was used or not, McSpadden technique showed significantly greater leakage than lateral or ultrasonic condensation method. Statistical analysis of the data indicated that the canals obturated in conjunction with sealer demonstrated less dye leakage than the canals obturated without sealer(p<0.01), except McSpadden technique. The ultrasonic condensation method appeared comparable sealing ability to the lateral condensation method.

  • PDF

Multistage Parallel Nulling-Partial PIC Receiver for Downlink MIMO MC-CDMA Systems (하향링크 다중 안테나 MC-CDMA 시스템을 위한 다단계 병렬 널링 및 병렬 부분 간섭 제거 수신기 설계)

  • 구정회;김경연;심세준;이충용
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.11
    • /
    • pp.1-7
    • /
    • 2004
  • We propose multistage parallel nulling (MPN) partial parallel interference cancellation (PPIC) receiver for downlink multiple-input multiple-output (MIMO) multicarrier (MC)-code division multiple access (CDMA) systems. Though the V-BLAST is a popular MIMO receiver, it shows error floor for multiuser downlink MIMO MC-CDMA systems. The proposed MPN-PPIC receiver does not produce error floor for multiuser case, and achieves substantial performance gains with multistage processing. For single user case, the proposed method also surpasses the V-BLAST receiver with multistage processing for MIMO MC-CDMA systems with chip level interleaving. The system performance of the proposed MPN-PPIC receiver is evaluated through computer simulations.

A Study on the MRC and EGC in Nakagami-m Fading Channel (나까카미-m 페이딩 채널에서 최대비합성과 동이득합성에 관한 연구)

  • Lee, Kwan-Houng;Lee, Myung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.5 s.43
    • /
    • pp.195-201
    • /
    • 2006
  • In multicarrier code division multiple access(MC-CDMA), the total system bandwidth is divided into a number of sub-bands, where each subband may use direct-sequence(DS) spreading and each subband signal is transmitted using a subcarrier frequency. In this paper, the system performance analysis of MC-CDMA using to gain combining(EGC) and maximal ratio combining(MRC) method over frequency selective Nakagami-m fading channel is analyzed. In the proposed system, a data sequence is serial-to-parallel converted, and MC-CDMA is used on each of the parallel data streams. The data streams are spread at both the symbol fraction level and at the chip level by the transmitter. In this paper, the compare to analysis,two standard diversity combining techniques, EGC and MRC, The good performance of system using to MRC more than EGC

  • PDF

Modeling and simulation of VERA core physics benchmark using OpenMC code

  • Abdullah O. Albugami;Abdullah S. Alomari;Abdullah I. Almarshad
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3388-3400
    • /
    • 2023
  • Detailed analysis of the neutron pathway through matter inside the nuclear reactor core is exceedingly needed for safety and economic considerations. Due to the constant development of high-performance computing technologies, neutronics analysis using computer codes became more effective and efficient to perform sophisticated neutronics calculations. In this work, a commercial pressurized water reactor (PWR) presented by Virtual Environment for Reactor Applications (VERA) Core Physics Benchmark are modeled and simulated using a high-fidelity simulation of OpenMC code in terms of criticality and fuel pin power distribution. Various problems have been selected from VERA benchmark ranging from a simple two-dimension (2D) pin cell problem to a complex three dimension (3D) full core problem. The development of the code capabilities for reactor physics methods has been implemented to investigate the accuracy and performance of the OpenMC code against VERA SCALE codes. The results of OpenMC code exhibit excellent agreement with VERA results with maximum Root Mean Square Error (RMSE) values of less than 0.04% and 1.3% for the criticality eigenvalues and pin power distributions, respectively. This demonstrates the successful utilization of the OpenMC code as a simulation tool for a whole core analysis. Further works are undergoing on the accuracy of OpenMC simulations for the impact of different fuel types and burnup levels and the analysis of the transient behavior and coupled thermal hydraulic feedback.