• Title/Summary/Keyword: MC method

Search Result 932, Processing Time 0.025 seconds

A Novel Channel Estimation Method Using Pilot Channels for Frequency-Interleaved MC-CDMA Systems (주파수 인터리빙된 MC-CDMA 시스템에서 파일럿 채널을 이용한 새로운 채널 추정 기법)

  • Cho Young-bo;Lee Jae-Gu;Oh seong-Mok;Kang Chang-eon;Hong Dae-sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.12C
    • /
    • pp.1186-1192
    • /
    • 2005
  • In this paper, we propose a novel channel estimation method based on pilot channel in a frequency interleaved multicarrier code division multiple access (MC-CDMA). Using the chip interleaving (CI) technique in the frequency domain make it possible to achieve higher frequency diversity gain than the system with conventional symbol interleaving. However, in CI-MC-CDMA systems, a pilot channel-based channel estimation (PCCE) cannot be applied because the orthogonality between pilot symbols and the data symbol is not maintained. The proposed method alters the system structure in order to maintain orthogonality between data and pilot channels over two consecutive subcarriers. Therefore, it can obtain accurate channel state information (CSI) in CI-MC-CDMA.

A Study on the Channel Estimation for MC-CDMA System (MC-CDMA 시스템을 위한 채널 추정에 관한 연구)

  • 박형근;이윤호;김응배;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8A
    • /
    • pp.1179-1186
    • /
    • 1999
  • Multi-carrier CDMA technique is more attractive in wireless communication system. It can support the effect of frequency diversity with higher spectral efficiency. In this paper, pilot symbol structure was proposed to estimate chann디 paramenters for MC-CDMA system and we analyzed the perfoemance of proposed MC-CDMA which compensates the received signals using the pilot symbols for link transmission. At first, we proposed the new method of pilot's usage for reverse link transmission that can distinguish accessing users whose signals undergo diggerent channels. And we analyzed the performance of coherent MC-CDMA reception using estimated channel parameters

  • PDF

Efficient Performance Evaluation Method for IS-95 System (IS-95 시스템 역방향 채널에서의 효율적인 성능평가 기법)

  • 전재춘;고윤진;정미선;황인관
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4B
    • /
    • pp.345-352
    • /
    • 2002
  • In this paper, in order to evaluate the performance of IS-95 system reverse link in white gaussian noise and rayleigh fading environment, we suggest epochal proposal to improve computer run-time and its efficiency is verified in terms of the number of samples. MC(Monte Carlo) simulation is the most popular simulation technique lately, but MC simulation requires a number of samples at low bit error rate. Therefore, MC cannot avoid the limit of computer run-time. To alleviate these problems, we apply the suggested method called central moment technique to the reverse link of the IS-95 system and can obtain discrete probability mass functions from Nth order central moments of the less number of received signal samples than those required in MC. Continuous cumulative probability distribution function can be accurately estimated by using interpolation and the improvement effect for the number of samples is proven.

Discrimination of Hanwoo from Holstein/black Angus meat by PCR-RFLP of MC1R gene (MC1R 유전자의 PCR-RFLP를 이용한 한우육과 젖소육/black Angus 수입육의 구분)

  • Kim, Tae-Jung;Lee, Jae-Il
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.3
    • /
    • pp.335-339
    • /
    • 2005
  • The melanocortin 1 receptor (MC1R) plays an important role in regulation of melanin pigment synthesis within mammalian melanocytes. Mutations within the gene encoding MC1R have been shown to explain coat color variations within several mammalian species including cattle. To develope a rapid and accurate method for the identification of Hanwoo, we performed a modified PCR-RFLP analysis of MC1R gene using single nucleotide polymorphism (SNP) within MC1R as a target. A size of 538 bp (537 bp for Hanwoo) was amplified by PCR, digested with Hpa II, and electrophoresed on a 1.5% agarose gel. A PCR product from Hanwoo showed a single band of 537 bp, whereas two fragments of 328 bp and 210 bp were detected in both Holstein and Black angus. The current result suggests that the PCR-RFLP using our primers and enzyme digestion system would be very accurate, easy and reproducible method to discriminate between Hanwoo and Holstein/Black angus meat.

UNCERTAINTY PROPAGATION ANALYSIS FOR YONGGWANG NUCLEAR UNIT 4 BY MCCARD/MASTER CORE ANALYSIS SYSTEM

  • Park, Ho Jin;Lee, Dong Hyuk;Shim, Hyung Jin;Kim, Chang Hyo
    • Nuclear Engineering and Technology
    • /
    • v.46 no.3
    • /
    • pp.291-298
    • /
    • 2014
  • This paper concerns estimating uncertainties of the core neutronics design parameters of power reactors by direct sampling method (DSM) calculations based on the two-step McCARD/MASTER design system in which McCARD is used to generate the fuel assembly (FA) homogenized few group constants (FGCs) while MASTER is used to conduct the core neutronics design computation. It presents an extended application of the uncertainty propagation analysis method originally designed for uncertainty quantification of the FA FGCs as a way to produce the covariances between the FGCs of any pair of FAs comprising the core, or the covariance matrix of the FA FGCs required for random sampling of the FA FGCs input sets into direct sampling core calculations by MASTER. For illustrative purposes, the uncertainties of core design parameters such as the effective multiplication factor ($k_{eff}$), normalized FA power densities, power peaking factors, etc. for the beginning of life (BOL) core of Yonggwang nuclear unit 4 (YGN4) at the hot zero power and all rods out are estimated by the McCARD/MASTER-based DSM computations. The results are compared with those from the uncertainty propagation analysis method based on the McCARD-predicted sensitivity coefficients of nuclear design parameters and the cross section covariance data.

The effect of front edge on efficiency for point and volume source geometries in p-type HPGe detectors

  • Esra Uyar ;Mustafa Hicabi Bolukdemir
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4220-4225
    • /
    • 2022
  • Monte Carlo (MC) simulations are increasingly being used as an alternative or supplement to the gamma spectrometric method in determining the full energy peak efficiency (FEPE) necessary for radionuclide identification and quantification. The MC method is more advantageous than the experimental method in terms of both cost and time. Experimental calibration with standard sources is difficult, especially for specimens with unusually shaped geometries. However, with MC, efficiency values can be obtained by modeling the geometry as desired without using any calibration source. Modeling the detector with the correct parameters is critical in the MC method. These parameters given to the user by the manufacturer are especially the dimensions of the crystal and its front edge, the thickness of the dead layer, dimensions, and materials of the detector components. This study aimed to investigate the effect of the front edge geometry of the detector crystal on efficiency, so the effect of rounded and sharp modeled front edges on the FEPE was investigated for <300 keV with three different HPGe detectors in point and volume source geometries using PHITS MC code. All results showed that the crystal should be modeled as a rounded edge, especially for gamma-ray energies below 100 keV.

Performance Evaluation of Direct Broadcasting Satellite Channel using a MC and QA Method (MC기법과 QA기법을 이용한 직접위성방송채널 성능평가)

  • 정지원;조형래;고성찬
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.4
    • /
    • pp.839-847
    • /
    • 1999
  • This paper presents the performance evaluation of direct broadcasting satellite by monte-carlo(MC) and quasi-analytic(QA) simulation method in the existence of uplink/downlink adjacent channel interference(ACI), co-channel interference(CCI), and gaussian noise. Korea's satellite system parameters and link design are used at the simulation. MC and QA simulation methods are a valuable adjunct to analytical performance.

  • PDF

Development of an open-source GUI computer program for modelling irradiation of multi-segmented phantoms using grid-based system for PHITS

  • Hiroshi Watabe;Kwan Ngok Yu;Nursel Safakatti;Mehrdad Shahmohammadi Beni
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.373-377
    • /
    • 2023
  • The Monte Carlo (MC) method has become an indispensable part of the nuclear radiation research field. Several widely used and well-known MC packages were developed for simulation of radiation transport and interaction with matter. All these MC packages require users to prepare an input script. The input script can become lengthy for complex models. The process of preparing these input scripts is time-consuming and error-prone. In the present work, we have developed an open-source GUI computer program for modelling radiation transport and interaction in multi-segmented slab phantoms using grid-based system for the widely used PHITS MC package. The developed tools would be useful for future users of PHITS MC package and particularly inexperienced users. The present program is distributed under GPL license and all users can freely download, modify and redistribute the program without any restrictions.

Comparison between Old and New Versions of Electron Monte Carlo (eMC) Dose Calculation

  • Seongmoon Jung;Jaeman Son;Hyeongmin Jin;Seonghee Kang;Jong Min Park;Jung-in Kim;Chang Heon Choi
    • Progress in Medical Physics
    • /
    • v.34 no.2
    • /
    • pp.15-22
    • /
    • 2023
  • This study compared the dose calculated using the electron Monte Carlo (eMC) dose calculation algorithm employing the old version (eMC V13.7) of the Varian Eclipse treatment-planning system (TPS) and its newer version (eMC V16.1). The eMC V16.1 was configured using the same beam data as the eMC V13.7. Beam data measured using the VitalBeam linear accelerator were implemented. A box-shaped water phantom (30×30×30 cm3) was generated in the TPS. Consequently, the TPS with eMC V13.7 and eMC V16.1 calculated the dose to the water phantom delivered by electron beams of various energies with a field size of 10×10 cm2. The calculations were repeated while changing the dose-smoothing levels and normalization method. Subsequently, the percentage depth dose and lateral profile of the dose distributions acquired by eMC V13.7 and eMC V16.1 were analyzed. In addition, the dose-volume histogram (DVH) differences between the two versions for the heterogeneous phantom with bone and lung inserted were compared. The doses calculated using eMC V16.1 were similar to those calculated using eMC V13.7 for the homogenous phantoms. However, a DVH difference was observed in the heterogeneous phantom, particularly in the bone material. The dose distribution calculated using eMC V16.1 was comparable to that of eMC V13.7 in the case of homogenous phantoms. The version changes resulted in a different DVH for the heterogeneous phantoms. However, further investigations to assess the DVH differences in patients and experimental validations for eMC V16.1, particularly for heterogeneous geometry, are required.

Advances for the time-dependent Monte Carlo neutron transport analysis in McCARD

  • Sang Hoon Jang;Hyung Jin Shim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2712-2722
    • /
    • 2023
  • For an accurate and efficient time-dependent Monte Carlo (TDMC) neutron transport analysis, several advanced methods are newly developed and implemented in the Seoul National University Monte Carlo code, McCARD. For an efficient control of the neutron population, a dynamic weight window method is devised to adjust the weight bounds of the implicit capture in the time bin-by-bin TDMC simulations. A moving geometry module is developed to model a continuous insertion or withdrawal of a control rod. Especially, the history-based batch method for the TDMC calculations is developed to predict the unbiased variance of a bin-wise mean estimate. The developed methods are verified for three-dimensional problems in the C5G7-TD benchmark, showing good agreements with results from a deterministic neutron transport analysis code, nTRACER, within the statistical uncertainty bounds. In addition, the TDMC analysis capability implemented in McCARD is demonstrated to search the optimum detector positions for the pulsed-neutron-source experiments in the Kyoto University Critical Assembly and AGN201K.