• Title/Summary/Keyword: MARK

Search Result 2,212, Processing Time 0.039 seconds

A Study on the Direction of Ubiquitous Space Development through the Analysis on Case Studies (연구 사례 분석을 통한 유비쿼터스 공간 개발 방향에 관한 연구)

  • 홍관선;이혁수
    • Archives of design research
    • /
    • v.16 no.3
    • /
    • pp.391-400
    • /
    • 2003
  • As the change of information and digital technology progresses, ubiquitous space is attracting attention as a new space concept in which the physical and digital spaces are connected to each other. As its meaning in latin itself - 'there exist everywhere at the same time'- implies, however, the ubiquitous space has been mostly discussed in a non-physical aspect, such as in a technological area, rather than its physical intrinsic property until now. Although theories regarding a ubiquitous city have been rarity suggested, in most cases, technological aspects such as the systemization or networking of individual information service have been the focus. However, one of the intentions induced in the concept that scholars including Mark weiser and Sakamura Ken introduced was to place humans in the center of the space in which the technology has been placed instead of humans. For this purpose, the renovation of human interface must be required. As technology develops, the achievement of ubiquitous space may be possible, and efforts to apply this to real space are making an appearance. The examples of the present research are the spaces that have a characteristic of the laboratory separated from life in the city, and the construct scale is in the level of an individual facility; therefore, further studies should functionally and spaciously connect all subjects existing in space and effectively relate this to real world. The present research is intended to demonstrate the investigation on several projects that are currently underway and the developmental direction of new, ubiquitous space.

  • PDF

The three dimensional measuring system for ELF magnetic fields with the multiturn loop-type sensors (멀티턴 루우프형 센서를 이용한 3차원 ELF 자장측정계)

  • Lee, Bok-Hee;Lee, Jeong-Gee;Kil, Gyung-Suk;Ahn, Chang-Hwan;Park, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.29-36
    • /
    • 1996
  • With the three dimensional magnetic field measuring system dealt with in this paper, accurate measurements and analyses of extremely low frequency(ELF) magnetic fields caused by starting and/or operating electric devices and power installations can be conducted. To obtain high performance for lower frequency and spatial components without any distortion, the measuring system is designed as three dimensionally including the multiturn loop-type magnetic field sensors, differential amplifiers and active integrators. As the results of calibration experiments, the frequency response characteristics of the measuring system range from 8[Hz] to about 53[kHz] for each direction of x, y, z axes, and the response sensitivities are 9.54, 9.21, $10.89[mV/{\mu}T]$, respectively. The actual survey experiments by using an oscillating impulse current generator confirm a reliability of the proposed measuring system. Also, through the other experiments by using small-sized induction motors, the magnetic field intensities when starting and steady-state operating mark 15.8, $8.61[{\mu}T]$ as maximum value, respectively. And those intensities decrease steeply according as the measuring distance increases.

  • PDF

Isolation and Structural Analysis of Acetyl Soyasaponin $A_1$ from Hypocotyl of Soybean (콩 Hypocotyl에서 Acetyl Soyasaponin $A_1$의 분리 및 구조 분석)

  • Kim, Sun-Lim;Bang, Myun-Ho;Kim, Jung-Tae;Chi, Hee-Youn;Chung Ill-Min;Kim, Hyun-Bok;Berhow Mark A.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.spc1
    • /
    • pp.166-173
    • /
    • 2006
  • Soyasaponins are phytochemicals of major interest fur their health benefits. Chemical investigation of a soybean phytochemical concentrate resulted in the isolation and identification of triterpenoid saponins. The MeOH extraction of defatted hypocotyl separated from soybeans was peformed by the automated solvent extractor (ASE). Fractionation was performed on a flash column ($150mm{\times}40mm$ i.d.) packed with a preparative $C_{18}$ reverse phase bulk packing material $(125\AA,\;55-105{\mu}m)$ and monitored at 210 nm, and collected 14 fractions. Consequent Fsat preparative column liquid chromatography (Fast PCLC) was performed for the purification of Fraction-I (Fr-I) collected from the fraction 8 and 9 of flash chromatography. Fsat PCLC was performed on a Luna $C_{18}\;10{\mu}m,\;100{\AA}$, semipreparative reverse phase column ($250cm{\times}50mm$ i.d.) for the purification of isolated unknown compound (Fr-I-2). Chemical structure of acetyl soyasaponin $A_1\;(MW:1436.6,\;C_{67}H_{104}O_{33})$ was identified and determined by a combination of extensive NMR ($^1H-NMR$, 400 MHz; $^{13}C-NMR$, 100 MHz; DEPT), IR, UV, and ESI-MS analysis.

An Analytic Study on the Figure of Number Line (수직선 표기법에 대한 분석 연구)

  • Suh, Bo Euk;Shin, Hyun Yong;Na, Jun Young
    • Journal of Educational Research in Mathematics
    • /
    • v.23 no.2
    • /
    • pp.135-152
    • /
    • 2013
  • The purpose of this study is to navigate to the desired direction for the figure of number line through the extensive analysis of number line in middle school textbooks and literatures. For the efficient achievement of this purpose, three research questions were posed as follows: First, we compare the figures of number line in textbooks of Korea and other countries. Korean math textbooks mark the arrow on both sides of number line. But, however, coordinate plane was marked with arrow on only positive direction of number line. In contrast, the majority of secondary school textbooks in several foreign countries has the arrow only on positive direction. Second, the change in the figure of number line has been analyzed historically from two perspectives. From the first to 2007-revised curriculum, math textbooks of Korea were analyzed. Since the 6th curriculum, the number of textbooks with arrows on both sides has increased sharply. That is, textbooks with one arrow almost have disappeared. It is strange that any explanation for this abrupt change can't be found. The following analysis was also performed on published foreign literatures since Descartes. There was no arrow in the early figures of number line. But after 19th century, number lines with one arrow have begun to appear. Third, based on the previous study, we propose a reasonable way for the figure of number line. In fact, we claim that, in terms of linguistic symbols, the number line should be with only one arrow on positive side.

  • PDF

A Study on the Health Benefits Labeling for Livestock Products (축산물의 유용성 표시에 대한 고찰)

  • Jang, Ae-Ra;Chae, Hyun-Seok;Yoo, Young-Mo;Ham, Jun-Sang;Jeong, Seok-Geun;Lee, Seung-Gyu;Ahn, Chong-Nam;Kim, Dong-Hoon;Lee, Sung-Ki;Lee, Eui-Soo
    • Food Science of Animal Resources
    • /
    • v.29 no.5
    • /
    • pp.599-611
    • /
    • 2009
  • This article concerns the labeling guideline for health benefits of livestock products. In recent years, livestock products with health benefits have emerged as a key market for livestock product industries. However, the current labeling regulation for functional foods severely prohibits livestock product industries from attaching most of the health benefits claims to the products. Also, manufacturers have some difficulties in labeling the health benefits of certain livestock products because of a lack of guidelines on health benefit claims for livestock products. Therefore, some livestock product industries and scientists have strongly demanded a revision of labeling regulation, Appended Chart No. 14 provided by Article 52 (2) of Enforcement Regulation of the Processing of Livestock Products Act, so they could mark the health benefits on their products. To support the 'revision of labeling regulation', the goals of this article were as follows; 1) to assess the current situation on nutrition labeling and nutrition claims on foods, 2) to determine the current situation on health claim regulatory systems used in foreign countries (CODEX, USA, Japan, EU, and Australia/New Zealand), 3) to assess the current situation on the health claim or health benefit claim regulations for functional foods, conventional foods, and livestock products in Korea, and 4) to determine the need for complement in health benefit claim for livestock products. In conclusion, guidelines for the use of health benefit claims on livestock products should be prepared as soon as possible and the guidelines should be viable and easy for manufacturers and control authorities to understand. Also, nutrient profiles should be developed to identify whether the livestock products are eligible to bear health benefit claims and to help consumers make the right choices.

A gene expression database for the molecular pharmacology of cancer

  • Scherf, Uwe;Ross, Douglas-T.;Waltham, Mark;Smith, Lawrence-H.;Lee, Jae-K.;Tanbe, Lorraine;Kohn, Kurt-W.;Reinhold, William-C.;Mayers, Timothy-G.;Andrews, Darren-T.;Scudiero, Dominic-A.;Eisen, Michael-B.;Sausville, Edward-A.;Pommier, Yves;Botstein, David;Brown, Patrick-O.;Weinstein, John-N.
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2001.08a
    • /
    • pp.129-137
    • /
    • 2001
  • We used cDNA microarrays to assess gene expression profiles in 60 human cancer used in a drug discovery screen by the National Cancer Institute. Using these data, we linked bioinformatics and chemoinformatics by correlating gene expression and drug activity pattens in the NCI60 lines. Clustering the cell lines on the basis of gene expression yielded relationships very different from those obtained by clustering the cell lines on the basis of their response to drugs. Gene-drug relationships for the clinical agents 5-fluorouracil and L-asparaginase exemplify how variations in the transcript levels of particular genes relate to mechanisms of drug sensitivity and resistance. This is the first study to intergrate large databases on gene expression and molecular pharmacology.

  • PDF

COMPARISON OF LINEAR AND NON-LINEAR NIR CALIBRATION METHODS USING LARGE FORAGE DATABASES

  • Berzaghi, Paolo;Flinn, Peter C.;Dardenne, Pierre;Lagerholm, Martin;Shenk, John S.;Westerhaus, Mark O.;Cowe, Ian A.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1141-1141
    • /
    • 2001
  • The aim of the study was to evaluate the performance of 3 calibration methods, modified partial least squares (MPLS), local PLS (LOCAL) and artificial neural network (ANN) on the prediction of chemical composition of forages, using a large NIR database. The study used forage samples (n=25,977) from Australia, Europe (Belgium, Germany, Italy and Sweden) and North America (Canada and U.S.A) with information relative to moisture, crude protein and neutral detergent fibre content. The spectra of the samples were collected with 10 different Foss NIR Systems instruments, which were either standardized or not standardized to one master instrument. The spectra were trimmed to a wavelength range between 1100 and 2498 nm. Two data sets, one standardized (IVAL) and the other not standardized (SVAL) were used as independent validation sets, but 10% of both sets were omitted and kept for later expansion of the calibration database. The remaining samples were combined into one database (n=21,696), which was split into 75% calibration (CALBASE) and 25% validation (VALBASE). The chemical components in the 3 validation data sets were predicted with each model derived from CALBASE using the calibration database before and after it was expanded with 10% of the samples from IVAL and SVAL data sets. Calibration performance was evaluated using standard error of prediction corrected for bias (SEP(C)), bias, slope and R2. None of the models appeared to be consistently better across all validation sets. VALBASE was predicted well by all models, with smaller SEP(C) and bias values than for IVAL and SVAL. This was not surprising as VALBASE was selected from the calibration database and it had a sample population similar to CALBASE, whereas IVAL and SVAL were completely independent validation sets. In most cases, Local and ANN models, but not modified PLS, showed considerable improvement in the prediction of IVAL and SVAL after the calibration database had been expanded with the 10% samples of IVAL and SVAL reserved for calibration expansion. The effects of sample processing, instrument standardization and differences in reference procedure were partially confounded in the validation sets, so it was not possible to determine which factors were most important. Further work on the development of large databases must address the problems of standardization of instruments, harmonization and standardization of laboratory procedures and even more importantly, the definition of the database population.

  • PDF

Effects of variety, region and season on near infrared reflectance spectroscopic analysis of quality parameters in red wine grapes

  • Esler, Michael B.;Gishen, Mark;Francis, I.Leigh;Dambergs, Robert G.;Kambouris, Ambrosias;Cynkar, Wies U.;Boehm, David R.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1523-1523
    • /
    • 2001
  • The wine industry requires practical methods for objectively measuring the composition of both red wine grapes on the vine to determine optimal harvest time; and of freshly harvested grapes for efficient allocation to vinery process streams for particular red wine products, and to determine payment of contract grapegrowers. To be practical for industry application these methods must be rapid, inexpensive and accurate. In most cases this restricts the analyses available to measurement of TSS (total soluble solids, predominantly sugars) by refractometry and pH by electropotentiometry. These two parameters, however, do not provide a comprehensive compositional characterization for the purpose of winemaking. The concentration of anthocyanin pigment in red wine grapes is an accepted indicator of potential wine quality and price. However, routine analysis for total anthocyanins is not considered as a practical option by the wider wine industry because of the high cost and slow turnaround time of this multi-step wet chemical laboratory analysis. Recent work by this ${group}^{l,2}$ has established the capability of near infrared (NIR) spectroscopy to provide rapid, accurate and simultaneous measurement of total anthocyanins, TSS and pH in red wine grapes. The analyses may be carried out equally well using either research grade scanning spectrometers or much simpler reduced spectral range portable diode-array based instrumentation. We have recently expanded on this work by collecting thousands of red wine grape samples in Australia. The sample set spans two vintages (1999 and 2000), five distinct geographical winegrowing regions and three main red wine grape varieties used in Australia (Cabernet Sauvignon, Shiraz and Merlot). Homogenized grape samples were scanned in diffuse reflectance mode on a FOSE NIR Systems6500 spectrometer and subject to laboratory analysis by the traditional methods for total anthocyanins, TSS and pH. We report here an analysis of the correlations between the NIR spectra and the laboratory data using standard chemometric algorithms within The Unscrambler software package. In particular, various subsets of the total data set are considered in turn to elucidate the effects of vintage, geographical area and grape variety on the measurement of grape composition by NIR spectroscopy. The relative ability of discrete calibrations to predict within and across these differences is considered. The results are then used to propose an optimal calibration strategy for red wine grape analysis.

  • PDF

STANDARDISATION OF NIR INSTRUMENTS, INFLUENCE OF THE CALIBRATION METHODS AND THE SIZE OF THE CLONING SET

  • Dardenne, Pierre;Cowe, Ian-A.;Berzaghi, Paolo;Flinn, Peter-C.;Lagerholm, Martin;Shenk, John-S.;Westerhaus, Mark-O.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1121-1121
    • /
    • 2001
  • A previous study (Berzaghi et al., 2001) evaluated the performance of 3 calibration methods, modified partial least squares (MPLS), local PLS (LOCAL) and artificial neural networks (ANN) on the prediction of the chemical composition of forages, using a large NIR database. The study used forage samples (n=25,977) from Australia, Europe (Belgium, Germany, Italy and Sweden) and North America (Canada and U.S.A) with reference values for moisture, crude protein and neutral detergent fibre content. The spectra of the samples were collected using 10 different Foss NIR Systems instruments, only some of which had been standardized to one master instrument. The aim of the present study was to evaluate the behaviour of these different calibration methods when predicting the same samples measured on different instruments. Twenty-two sealed samples of different kind of forages were measured in duplicate on seven instruments (one master and six slaves). Three sets of near infrared spectra (1100 to 2500nm) were created. The first set consisted of the spectra in their original form (unstandardized); the second set was created using a single sample standardization (Clone1); the third was created using a multiple sample procedure (Clone6). WinISI software (Infrasoft International Inc., Port Mathilda, PA, USA) was used to perform both types of standardization, Clone1 is just a photometric offset between a “master” instrument and the “slave” instrument. Clone6 modifies both the X-axis through a wavelength adjustment and the Y-axis through a simple regression wavelength by wavelength. The Clone1 procedure used one sample spectrally close to the centre of the population. The six samples used in Clone 6 were selected to cover the range of spectral variation in the sample set. The remaining fifteen samples were used to evaluate the performances of the different models. The predicted values for dry matter, protein and neutral detergent fibre from the master Instrument were considered as “reference Y values” when computing the statistics RMSEP, SEPC, R, Bias, Slope, mean GH (global Mahalanobis distance) and mean NH (neighbourhood Mahalanobis distance) for the 6 slave instruments. From the results we conclude that i) all the calibration techniques gave satisfactory results after standardization. Without standardization the predicted data from the slaves would have required slope and bias correction to produce acceptable statistics. ii) Standardization reduced the errors for all calibration methods and parameters tested, reducing not only systematic biases but also random errors. iii) Standardization removed slope effects that were significantly different from 1.0 in most of the cases. iv) Clone1 and Clone6 gave similar results except for NDF where Clone6 gave better RMSEP values than Clone1. v) GH and NH were reduced by half even with very large data sets including unstandardized spectra.

  • PDF

Wine quality grading by near infrared spectroscopy.

  • Dambergs, Robert G.;Kambouris, Ambrosias;Schumacher, Nathan;Francis, I. Leigh;Esler, Michael B.;Gishen, Mark
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1253-1253
    • /
    • 2001
  • The ability to accurately assess wine quality is important during the wine making process, particularly when allocating batches of wines to styles determined by consumer requirements. Grape payments are often determined by the quality category of the wine that is produced from them. Wine quality, in terms of sensory characteristics, is normally a subjective measure, performed by experienced winemakers, wine competition judges or winetasting panellists. By nature, such assessments can be biased by individual preferences and may be subject to day-to-day variation. Taste and aroma compounds are often present in concentrations below the detection limit of near infrared (NIR) spectroscopy but the more abundant organic compounds offer potential for objective quality grading by this technique. Samples were drawn from one of Australia's major wine shows and from BRL Hardy's post-vintage wine quality allocation tastings. The samples were scanned in transmission mode with a FOSS NIR Systems 6500, over the wavelength range 400-2500 ㎚. Data analysis was performed with the Vision chemometrics package. With samples from the allocation tastings, the best correlations between NIR spectra and tasting data were obtained with dry red wines. These calibrations used loadings in the wavelengths related to anthocyanins, ethanol and possibly tannins. Anthocyanins are a group of compounds responsible for colour in red wines - restricting the wavelengths to those relating to anthocyanins produced calibrations of similar accuracy to those using the full wavelength range. This was particularly marked with Merlot, a variety that tends to have relatively lower anthocyanin levels than Cabernet Sauvignon and Shiraz. For dry white wines, calibrations appeared to be more dependent on ethanol characteristics of the spectrum, implying that quality correlated with fruit maturity. The correlations between NIR spectra and sensory data obtained using the wine show samples were less significant in general. This may be related to the fact that within most classes in the show, the samples may span vintages, glowing areas and winemaking styles, even though they may be made from only one grape variety. For dry red wines, the best calibrations were obtained with a class of Pinot Noir - a variety that tends to be produced in limited areas in Australia and would represent the least matrix variation. Good correlations were obtained with a tawny port class - these wines are sweet, fortified wines, that are aged for long periods in wooden barrels. During the ageing process Maillard browning compounds are formed and the water is lost through the barrels in preference to ethanol, producing “concentrated” darkly coloured wines with high alcohol content. These calibrations indicated heaviest loadings in the water regions of the spectrum, suggesting that “concentration” of the wines was important, whilst the visible and alcohol regions of the spectrum also featured as important factors. NIR calibrations based on sensory scores will always be difficult to obtain due to variation between individual winetasters. Nevertheless, these results warrant further investigation and may provide valuable Insight into the main parameters affecting wine quality.

  • PDF