• 제목/요약/키워드: M2M Device

검색결과 2,296건 처리시간 0.032초

Fe-Si 전기강판 폐스크랩을 이용한 연자성 분말 및 테이프 제조기술 (Manufacturing Technology for Tape Casting and Soft Magnetic Powder Using by Recycling Scrap of Fe-Si Electrical Sheet)

  • 홍원식;김상현;박지연;오철민;이우성;김승겸;한상조;심금택;김휘준
    • 마이크로전자및패키징학회지
    • /
    • 제23권2호
    • /
    • pp.11-18
    • /
    • 2016
  • This study focused on examining the possibility for recycling of Fe-Si electric sheet. We manufactured Fe-6.5Si mother alloy using by Fe-Si electric sheet scrap for transformer core materials. And then, soft magnetic alloy powder which diameter and shape were $45{\sim}150{\mu}m$ and sphere type was prepared by gas atomization process. As we compared to commercial Fe-6.5Si powder, its diameter distribution and microstructure of recycled powder was a similar. To investigate the possibility of reusing the soft magnetic composite sheet for electronics, recycled powder was treated to have a high aspect ratio (AR), and we finally obtained the 65~66 AR and $2.3{\mu}m$ thickness powder. To release the residual stress of powder, heat treatment was conducted under $300{\sim}400^{\circ}C$, $N_2$ gas. And then, soft magnetic sheet was made by tape casting process using by those powders. After the density and permeability of tape was measured, and we confirmed that the recycled Fe-Si electric sheet scrap was possible to reuse the soft magnetic materials of electronics.

국부치료를 위한 Retractor용 LED 광섬유 의료보조조명 장치 개발 (LED Fiber-Optic Lighting Devices Developed for Medical Assistance for the Local Treatment Retractor)

  • 어익수
    • 한국산학기술학회논문지
    • /
    • 제17권2호
    • /
    • pp.666-671
    • /
    • 2016
  • 본 논문에서 소개하는 기기는 병의원의 수술실에서 수술전용조명인 무영등만으로는 직접 조명할 수 없는 수술부위의 환부에 근접 국부조명을 제공하는 장치로서, 임상의들이 인체 깊숙한 환부의 질환 치료를 안전하게 시술하도록 한다. 이 의료 보조조명 장치는 종양제거나 혈관봉합과 같은 미세한 수술과정에서 발생할 수 있는 치명적인 수술 실패를 방지하기 위해서 필요한 장치이다. 광원 및 전원부 등의 구성요소는 저전력, 소형화로 설계되었으며, 협각렌즈를 사용하여 광확산 효과의 증가와 집중 조명에 용이하도록 하였다. 광케이블을 사용한 조명전송과 조명장치의 Endcap은 사용 후 다음 환자를 위하여 소독이 가능하도록 방수형으로 설계되었다. 리트렉터 조명장치 개발 후 이루어진 광원특성 측정 결과, 조도 490lux, 휘도 $11,550cd/m^2$, 연색성 78, 색온도 11,000K 및 고른 조도분포도를 보여 국부 의료보조조명으로서 적합하였음이 확인되었다.

Pb(Ni1/3Nb2/3)O3-PZT 세라믹스 고용체에서 과잉 NiO첨가에 따른 압전특성 변화 (The Effect of NiO Addition to the PNN-PZT Piezoelectric Ceramics on Piezoelectric Properties)

  • 최용길;손영진;권준철;조경원;윤만순;김일호;김영민;어순철
    • 한국재료학회지
    • /
    • 제15권6호
    • /
    • pp.413-418
    • /
    • 2005
  • Perovskite $Pb(Ni_{1/3}Nb_{2/3})O_3-Pb(Zr,Ti)O_3[PNN-PZT]$ ceramics were synthesized by conventional ceramic processing technique. In order to modify piezoelectric properties for sensor application in this system, NiO addition was considered to provide $Ni^{+2}$ as an acceptor, which was known to occupy with B site in the structure. The effect of NiO addition up to $8\;mol\%$ on the following piezoelectric properties as well as sintering properties was investigated. When NiO added more than $1\;mol\%$, average grain size was decreased and second phase was found to form. Moreover, the second phase caused decrease in relative dielectric constant $(\varepsilon_{33}T/\varepsilon0)$, electro-mechanical coupling factor $(k_p)$, and piezoelectric charge constant $(d_{33})$, while increasing mechanical quality factor $(Q_m)$. When $1\;mol\%$ NiO was added, density, dielectric properties and piezoelectric properties were abruptly increased.

액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발 (Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • 제22권4호
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

대전 일부 지역 치과종사자의 화학소독제에 관한 지식도 연구 (Knowledge on the chemical disinfectants among dental workers in some Daejeon region)

  • 민희홍;안권숙
    • 한국치위생학회지
    • /
    • 제7권4호
    • /
    • pp.455-470
    • /
    • 2007
  • The usage of appropriate disinfectants is essential for infection control in dental hospitals, dental clinics. Inadequate use of disinfectants is the cause of human or environmental toxicity and is a waste of cost. This study was aimed to assess the level of knowledge on the disinfection and chemical disinfectants among dental workers in dental hospitals, dental clinics. It's ultimately intended to serve as a basis for the preparation of more effective, appropriate educational programs on the disinfection and manuals on the use of disinfectants for dental workers. This study enforced a questionnaire with 184 dental workers employed in dental hospitals, dental clinics from 15 Aug. to 15 Sep. 2007, in the area of Daejeon. The obtained result were as follows; 1. The population sociological feature of dental hospital and dental clinic showed that significant differences of dental service career(pM0.039). Dental service career of dental workers shows; below 3 years 42.9%, 4~6 years 34.7%, more than 7 years 22.4% in dental hospitals, below 3 years 30.4%, 4~6 years 26.7%, more than 7 years 43.0% in dental clinics(pM0.039). 2. The average score of dental workers knowledge in 'Critical item soaks in high-level disinfectants for 20minutes was 2.73V0.49 point, got from knowledge of dental instrument is appropriate to immerse before sterilization in the dental device disinfection(pM0.002). 3. In the general disinfection which it follows in education experience of chemical disinfectants direction for use, 'Direction for use by Spaulding process classification' responded that the correct answer was the education experience dental workers 60.0%, the education non-experience dental workers 39.5%(p=0.026). 4. In the dental device disinfection which it follows in education experience of chemical disinfectants direction for use. 'High level disinfection is not applied for the non-critical items and equipment' responded that the education experience dental workers 49.2%, the education non-experience dental workers 31.9%(pM0.045), 'Semi-critical items is applied same method in presence of the infection disease which it acts responded that the education experience dental workers 44.6% answer back, the education non-experience dental workers 24.4%(pM0.017). 5. 'A hand disinfectants of anticeptics have effect' the education experience dental workers 78.5% answer back, the education non-experience dental workers 52.9%(pM0.003). 1t uses with hand disinfectants when the instruments which be imbrued and patient contact', the education experience dental workers 78.5% answer back, the education non-experience dental workers 62.2%(pM0.026), 'Boric acid solution uses for the skin disinfectants the education experience dental workers 52.3% answer back, the education non-experience dental workers is 37.0%(pM0.016), 'Gluconate have effective difference which it follows in chemical disinfectant consistency and the solution type' education experience dental workers 72.3% answer back, education non-experience dental workers 47.9%(pM0.004). 6. The education experience dental workers were appeared higher than the education non-experience dental workers in knowledge of the disinfection and chemical disinfectants. Consequently system and the specialty education which is standardized continuously must be provided to all dental workers.

  • PDF

CMOS 공정을 이용한 2차원 SSIMT의 특성 (Characteristics of the 2-D SSIMT using a CMOS Process)

  • 송윤귀;류지구
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.697-700
    • /
    • 2007
  • A novel 2-Dimensional Suppressed Sidewall Injection Magnetotransistor (SSIMT) with high linearity has been fabricated on the standard CMOS technology and experimentally verified. The novel 2-Dimensional SSIMT overcomes the restriction of the standard CMOS technology. Experimental results of the fabricated 2-Dimensional SSIMT show that the variation of each collector output currents are extremely linear as a function of magnetic field from -200mT to 200mT at $I_B = 1 mA,\;V_{CE} = 5 V\;and\;V_{SE} = 5 V$. The relative sensitivity shows up to 13 %/T. The measured nonlinearity of the fabricated device is about 0.9%.

스핀밸브 바이오 센서를 이용한 혈액과 나노입자의 자성특성 검출 (The Detection of Magnetic Properties in Blood and Nanoparticles using Spin Valve Biosensor)

  • 박상현;소광섭;안명천;황도근;이상석
    • 한국자기학회지
    • /
    • 제16권3호
    • /
    • pp.157-162
    • /
    • 2006
  • 이온빔 증착 스퍼터링법과 고아 리소그래피법으로 FeMn-스핀밸브 바이오 센서를 제작하였다. 혈액내의 Fe를 포함한 헤모글로빈(Hemoglobin)과 나노 자성입자의 자성검출은 최대 자장감응 약 $0.1{\sim}0.8%/Oe$인 거대자기저항 스핀밸브 바이오 센싱소자를 이용하였다. 사용된 혈액은 인체의 피였고, Co-페라이트 나노 자성입자는 수용성 무정형 실리카로 코팅이 되었으며, 그 크기의 평균직경의 범위는 9nm에서 50nm이었다. 실제 크기가 $5x10{\mu}m^2 $ 혹은 $2x6{\mu}m^2 $로 제작된 센싱소자의 4 전극 중 전류 입력단자에 흐르는 감지전류는 1 mA로 하였다. 혈액과 나노자성 입자가 소자의 중앙부분으로 떨어졌을 때, 출력신호는 각각 자성 여부의 검출 특성을 알 수 있는 충분한 크기로 나타났다.

생활계(生活系) 폐기물(廢棄物) 봉투(封套) 파봉을 위한 회전(回傳)칼날팔각(八角)드럼식(式) 파봉장치(裝置) 개발(開發)에 관(關)한 연구(硏究) (Development of Bag Rupturing Device with Octagonal Rotating Blade Drums for MSWs)

  • 이병선;나경덕;한상국;최우진;박은규;김동호
    • 자원리싸이클링
    • /
    • 제18권5호
    • /
    • pp.63-71
    • /
    • 2009
  • 재활용선별시설에서 파봉공정은 연계된 선별공정을 위한 필수 공정으로 주로 인력에 의한 작업과 일부 기계식 파봉장치가 도입되었다. 그러나, 기계식 파봉장치의 경우 재활용 대상폐기물을 파쇄하여 선별효율의 저하 및 폭발 등 작업자의 안전문제가 자주 발생하고 있다. 본 연구에서는 기존 파봉 방식의 문제점을 해결 할 수 있는 회전칼날팔각드럼식 파봉 정량공급 장치를 개발하여 성능평가 및 환경성 검토를 통한 현장 적용 가능성 평가를 수행하였다. 실험결과에 의하면 처리용량은 드럼회전수 8.2 rpm, 벨트컨베이어 속도 1.25 m/min에서 5.6 ton/hr로 설계용량인 5.0 ton/hr를 만족하였으며, 최대 처리용량은 8.8 ton/hr으로 나타났다. 봉투 속 봉투의 파봉효율은 95.6% 및 겉봉투의 경우에는 100%로 나타났으며, 특히 재활용대상폐기물 중 가장 쉽게 파손되는 유리병의 원형보존율은 약 96.5%로 정가되었다. 본 장치의 소음, 진동 및 비산먼지 농도 등에 대한 환경성 정토결과 환경오염배출허용 법적기준치를 모두 만족하는 것으로 조사되었다. 따라서, 본 파봉장치를 재활용선별시설에 적용할 경우 기존의 인력파봉과 기계식파봉에서 발생되었던 문제점을 크게 개선할 수 있다.

Optically transparent and electrically conductive indium-tin-oxide nanowires for transparent photodetectors

  • Kim, Hyunki;Park, Wanghee;Ban, Dongkyun;Kim, Hong-Sik;Patel, Malkeshkumar;Yadav, Pankaj;Kim, Joondong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.390.2-390.2
    • /
    • 2016
  • Single crystalline indium-tin-oxide (ITO) nanowires (NWs) were grown by sputtering method. A thin Ni film of 5 nm was coated before ITO sputtering. Thermal treatment forms Ni nanoparticles, which act as templates to diffuse Ni into the sputtered ITO layer to grow single crystalline ITO NWs. Highly optical transparent photoelectric devices were realized by using a transparent metal-oxide semiconductor heterojunction by combining of p-type NiO and n-type ZnO. A functional template of ITO nanowires was applied to this transparent heterojunction device to enlarge the light-reactive surface. The ITO NWs/n-ZnO/p-NiO heterojunction device provided a significant high rectification ratio of 275 with a considerably low reverse saturation current of 0.2 nA. The optical transparency was about 80% for visible wavelengths, however showed an excellent blocking UV light. The nanostructured transparent heterojunction devices were applied for UV photodetectors to show ultra fast photoresponses with a rise time of 8.3 mS and a fall time of 20 ms, respectively. We suggest this transparent and super-performing UV responser can practically applied in transparent electronics and smart window applications.

  • PDF

A Dielectrophoresis Microfluidic Device for Trapping Bioparticles at Low Voltage and Frequency

  • Jeong, Jin-Tae;Shin, Hyun-Min;Kim, Duwoon;Lee, Kyeong-Hwan
    • Journal of Biosystems Engineering
    • /
    • 제41권1호
    • /
    • pp.60-65
    • /
    • 2016
  • Purpose: The necessity for precise manipulation of bioparticles has greatly increased in the fields of bioscience, biomedical, and environmental monitoring. Dielectrophoresis (DEP) is considered to be an ideal technique to manipulate bioparticles. The objective of this study is to develop a DEP microfluidic device that can trap fluorescent beads, which mimic bioparticles, at the low voltage and frequency of the sinusoidal signal supplied to the microfluidic device. Methods: A DEP microfluidic device, which is composed of polydimethylsiloxane (PDMS) channels and interdigitated electrode networks, is fabricated to trap fluorescent beads. The geometry of the interdigitated electrodes is determined through computational simulation. To determine the optimum voltage and frequency of the sinusoidal signal supplied to the device, the experiments of trapping beads are conducted at various combinations of voltage and frequency. The performance of the DEP microfluidic device is evaluated by investigating the correlation between fluorescent intensities and bead concentrations. Results: The optimum ratio of the widths between the negative and positive electrodes was 1:4 ($20:80{\mu}m$) at a gap of $20{\mu}m$ between the two electrodes. The DEP electrode networks were fabricated based on this geometry and used for the bead trapping experiments. The optimum voltage and frequency of the supplied signal for trapping fluorescent beads were 15 V and 5 kHz, respectively. The fluorescent intensity of the trapped beads increased linearly as the bead concentration increased. The coefficient of determination ($R^2$) between the fluorescent intensity and the bead concentration was 0.989. Conclusions: It is concluded that the microfluidic device developed in this study is promising for trapping bioparticles, such as a cell or virus, if they are conjugated to beads, and their concentration is quantified.