• 제목/요약/키워드: M2M Device

검색결과 2,298건 처리시간 0.034초

액제 정밀계량장치를 이용한 액제 자동조제 시스템개발 (Development of Automatic Nutrient-Solution Control System Using a Low -Cost and Precise Liquid Metering Device)

  • 류관희;홍순호;이규철;이정훈;황호준
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1997년도 하계 학술대회 논문집
    • /
    • pp.89-98
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution control system for small-scale growers. The nutrient-solution control system consisted of a low-cost and precise metering device and a personal computer. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-soIution. The performance of the nutrient-solution control system was evaluated through the control of EC and pH while compared with those of commercial nutrient-solution control system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. An automatic nutrient-solution control system based on a low-cost and precise metering device was developed. 2. The developed system controlled EC and pH within $\pm$0.05 mS/cm and $\pm$0.2 pH full scale error respectively at $24^{/circ}C$. 3. When using the commercial system, the controlled values of EC and pH of the 500l of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at $22^{/circ}C$. 4. The developed nutrient-solution control system showed $\pm$0.05 mS/cm of deviation from the setting EC value over the experimental cultivation period. 5. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

자성박막 소자 에칭용 전자 사이클로트론 공명 이온밀링 시스템 제작과 특성연구 (Fabrication and Performance of Electron Cyclotron Resonance Ion Milling System for Etching of Magnetic Film Device)

  • 이원형;황도근;이상석;이장로
    • 한국자기학회지
    • /
    • 제25권5호
    • /
    • pp.149-155
    • /
    • 2015
  • 자성박막의 미세패턴 소자 제작을 위해 전자 사이크로트론 공명(electron cyclotron resonance; ECR) Ar 이온밀링 시스템을 제작하였다. 소자 식각에 적용한 ECR 이온밀링 시스템에서 주파수 2.45 GHz 파장 12.24 cm의 마이크로파 소스인 마그네트론은 전력 600 W에 의해 가동되어 파장의 정수배에 맞추어 만든 도파관을 통하여 전달되도록 설계하였다. 마이크로파 주파수와 공명시키기 위해 전자석으로 908 G의 자기장을 인가하였고, 알곤 개스를 cavity에 유입시켜서 방전된 이온들은 그리드 사이에 인가한 약 1000 V의 가속전압에 의한 에너지를 갖고 표면을 밀링한다. 이것을 이용하여 다층구조 GMR-SV(giant magnetoresistance-spin valve) 자성박막에 광 리소그래피, 이온밀링 및 전극제작 공정과정을 마치고 폭이 $1{\mu}m$에서 $9{\mu}m$까지의 소자들을 제작하여 광학현미경으로 소자 크기를 관찰하였다.

Synthesis and Electro-optical Properties of π-Conjugated Polymer Based on 10-Hexylphenothiazine and Aromatic 1,2,4-Triazole

  • Choi, Ji-Young;Kim, Dong-Han;Lee, Bong;Kim, Joo-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권9호
    • /
    • pp.1933-1938
    • /
    • 2009
  • New $\pi$-conjugated polymer with vinylene linkage, poly((10-hexyl-3,7-phenothiazine)-alt-(4-(4-butyl-phenyl)- 3,5-diphenyl-4H-[1,2,4]triazole)-3,5-vinylene) (PTV-TAZ) was synthesized by the Heck coupling reaction. The photoluminescence (PL) maximum wavelength and the band gap energy of PTV-TAZ film were 555 nm and 2.41 eV, respectively. The HOMO energy level of PTV-TAZ was -4.99 eV, which was slightly lower than that of PTV (-4.89 eV). Electron deficient aromatic 1,2,4-triazole (TAZ) in the polymer backbone does not affect the HOMO energy level significantly. The maximum efficiency and brightness of double layer structured electroluminescent (EL) device (ITO/PEDOT (30 nm)/PTV-TAZ (60 nm)/Al) were 0.247 cd/A and 553 cd/$m^2$, respectively, which were significantly higher than those of the device based PTV (1.65 ${\times}\;10^{-4}$ cd/A and 4.3 cd/$m^2$). This is due to that TAZ unit improves electron transporting ability in the emissive layer. The turn-on voltage (defined as the voltage required to give a luminescence of 1 cd/$m^2$) of brightness of the device based on PTV-TAZ was 12.0 V, which was similar to that the based on PTV (11.5 V). This is due to that the ionization potential of PTV-TAZ is very similar to that of PTV.

Efficient orange-red OLED using a new DCM derivative as a doping molecule

  • Hwang, Do-Hoon;Lee, Jong-Don;Lee, Moon-Jae;Lee, Chang-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.579-581
    • /
    • 2004
  • A new DCM derivative containing the phenoxazine moiety (DCPXZ) has been synthesized for use as a red fluorescent dye molecule in organic light-emitting diodes (OLEDs). The photoluminescence and electroluminescence properties of DCPXZ were examined. The maximum photoluminescence of DCPXZ in chloroform solution ($10^{-5}$ mol) was observed at 616 nm. EL devices were fabricated with the structure ITO/PEDOT-PSS/Cu-PC(15nm)/${\alpha}$-NPD(45nm)/$Alq_3$:DCPXZ(30nm)/$Alq_3$(30nm)/LiF(0.5nm)/Al. The maximum EL emission for the 2.0% DCPXZ-doped device was at 608 nm with CIE coordinates (0.57, 0.42). The EL device exhibited a maximum brightness of 15,000 cd/$m^2$ at 19.4 V and a power efficiency of 1.04 lm/W at a luminance of 100 cd/$m^2$.

  • PDF

Synthesis and Electroluminescent Properties of Cabazolyl Vinylene Derivatives

  • Seo, H.J.;Park, H.C.;Lee, S.E.;Park, J.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.952-954
    • /
    • 2003
  • We report the photo-(PL) and electroluminescence (EL) properties of new conjugated compounds based on carbazolyl vinylene moiety, 3,3'-(1,4-phenylene di-2,1-ethenediyl) bis[9-ethyl-(E,E)-9H-carbazole](PEEC) and 3,3'-([1,1'-biphenyl]-4,4'-diyldi-2,1-ethenediyl)bis[9-ethyl-9H-carbazole](BPEEC), as emitting materials. The ITO/m-MTDATA/NPB/BPEEC/Alq3/LiF/Al device shows bluish-green EL spectrum at 490nm and turn-on voltage at 8V. PEEC shows bluish-green EL around ${\lambda}$ max=496nm and turn-on voltage at 6V and 2.4 Cd/A efficiency in ITO/m-MTDATA/NPB/PEEC/Alq3/LiF/Al device.

  • PDF

서브마이크론 MOSFET의 파라메터 추출 및 소자 특성 (1)

  • 서용진;장의구
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권2호
    • /
    • pp.107-116
    • /
    • 1994
  • In the manufacturing of VLSI circuits, variations of device characteristics due to the slight differences in process parameters drastically aggravate the performances of fabricated devices. Therefore, it is very important to establish optimal process conditions in order to minimize deviations of device characteristics. In this paper, we used one-dimensional process simulator, SUPREM-II, and two dimensional device simulator, MINIMOS 4.0 in order to extract optimal process parameter which can minimize changes of the device characteristics caused by process parameter variation in the case of short channel nMOSFET and pMOSFET device. From this simulation, we have derived the dependence relations between process parameters and device characteristics. Here, we have suggested a method to extract process parameters from design trend curve(DTC) obtained by these dependence relations. And we have discussed short channel effects and device limitations by scaling down MOSFET dimensions.

  • PDF

엣시머 레이져를 이용한 폴리우레탄의 미세 가공에 관한 연구 (A Study on the Micro Machining in Polyurethane by Excimer Laser)

  • 김재구;이성국;윤경구
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.366-370
    • /
    • 1997
  • This paper descibes a micro groove machining process on the polyurethane biopolymer by KrF excimer laser. To investigate the etch charcteristics of polyurethane biopolymer quantitatively,laser system for ablation was installed with high precison moter and then polymer ablation experiment, in which paramteters were fluence,pulse repetition rate,numbers of pulses and assist gas, was carred out. In this experiment, we found out that the value of critical energy density for ablation is 30mJ/cmsup2/ and the etching rate is more dependent on the pulse number and fluence than any other pamameter. Finally, we machined micro grooves for fiexibility as width 300.mu.m depth 100.mu.m and port for micro-devices mounting as length 100.mu.m width 300.mu.m depth .mu.m on the outer wallof polyurethane biopolymer tube which is used as medical device.

  • PDF

Design of control software for GMACS (Giant Magellan Telescope Multi-Object Astronomical and Cosmological Spectrograph)

  • Lee, Hye-In;Ji, Tae-Geun;Pak, Soojong;Cook, Erika;Froning, Cynthia;Schmidt, Luke M.;Marshall, Jennifer L.;DePoy, Darren L.
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.79.3-79.3
    • /
    • 2019
  • GMACS is one of the first light instruments for the Giant Magellan Telescope (GMT). The development of GMACS control software follows Agile software development process, and the design of the software is based on the Unified Model Language (UML). In this poster, we present the architecture of the GMACS software and the development processes. As an example of the software development, we show the software of the Slit Mask Exchange Mechanism Prototype (SMEM-P) which is part of the GMACS Device Control Package (DCP).

  • PDF

Wavelength Conversion Lanthanide(III)-cored Complex for Highly Efficient Dye-sensitized Solar Cells

  • Oh, Jung-Hwan;Song, Hae-Min;Eom, Yu-Kyung;Ryu, Jung-Ho;Ju, Myung-Jong;Kim, Hwan-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2743-2750
    • /
    • 2011
  • Lanthanide(III)-cored complex as a wavelength conversion material has been successfully designed and synthesized for highly efficient dye-sensitized solar cells, for the first time, since light with a short wavelength has not been effectively used for generating electric power owing to the limited absorption of these DSSCs in the UV region. A black dye (BD) was chosen and used as a sensitizer, because BD has a relatively weak light absorption at shorter wavelengths. The overall conversion efficiency of the BD/WCM device was remarkably increased, even with the relatively small amount of WCM added to the device. The enhancement in $V_{oc}$ by WCM, like DCA, could be correlated with the suppression of electron recombination between the injected electrons and $I_3{^-}$ ions. Furthermore, the short-circuit current density was significantly increased by WCM with a strong UV light-harvesting effect. The energy transfer from the Eu(III)-cored complex to the $TiO_2$ film occurred via the dye, so the number of electrons injected into the $TiO_2$ surface increased, i.e., the short-circuit current density was increased. As a result, BD/WCM-sensitized solar cells exhibit superior device performance with the enhanced conversion efficiency by a factor of 1.22 under AM 1.5 sunlight: The photovoltaic performance of the BD/WCM-based DSSC exhibited remarkably high values, $J_{sc}$ of 17.72 mA/$cm^2$, $V_{oc}$ of 720 mV, and a conversion efficiency of 9.28% at 100 mW $cm^{-2}$, compared to a standard DSSC with $J_{sc}$ of 15.53 mA/$cm^2$, $V_{oc}$ of 689 mV, and a conversion efficiency of 7.58% at 100 mW $cm^{-2}$. Therefore, the Eu(III)-cored complex is a promising candidate as a new wavelength conversion coadsorbent for highly efficient dye-sensitized solar cells to improve UV light harvesting through energy transfer processes. The abstract should be a single paragraph which summaries the content of the article.

Conversion coefficients for the estimation of effective dose in cone-beam CT

  • Kim, Dong-Soo;Rashsuren, Oyuntugs;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.21-29
    • /
    • 2014
  • Purpose: To determine the conversion coefficients (CCs) from the dose-area product (DAP) value to effective dose in cone-beam CT. Materials and Methods: A CBCT scanner with four fields of view (FOV) was used. Using two exposure settings of the adult standard and low dose exposure, DAP values were measured with a DAP meter in C mode ($200mm{\times}179mm$), P mode ($154mm{\times}154mm$), I mode ($102mm{\times}102mm$), and D mode ($51mm{\times}51mm$). The effective doses were also investigated at each mode using an adult male head and neck phantom and thermoluminescent chips. Linear regressive analysis of the DAP and effective dose values was used to calculate the CCs for each CBCT examination. Results: For the C mode, the P mode at the maxilla, and the P mode at the mandible, the CCs were 0.049 ${\mu}Sv/mGycm^2$, 0.067 ${\mu}Sv/mGycm^2$, and 0.064 ${\mu}Sv/mGycm^2$, respectively. For the I mode, the CCs at the maxilla and mandible were 0.076 ${\mu}Sv/mGycm^2$ and 0.095 ${\mu}Sv/mGycm^2$, respectively. For the D mode at the maxillary incisors, molars, and mandibular molars, the CCs were 0.038 ${\mu}Sv/mGycm^2$, 0.041 ${\mu}Sv/mGycm^2$, and 0.146 ${\mu}Sv/mGycm^2$, respectively. Conclusion: The CCs in one CBCT device with fixed 80 kV ranged from 0.038 ${\mu}Sv/mGycm^2$ to 0.146 ${\mu}Sv/mGycm^2$ according to the imaging modes and irradiated region and were highest for the D mode at the mandibular molar.