• 제목/요약/키워드: M2M Device

검색결과 2,296건 처리시간 0.031초

소형 계수용 및 영상용 감마프로브 시스템의 설계와 성능평가 (Design and Performance Evaluation of Small Size Counting and Imaging Gamma Probe System)

  • 양묘근;곽철은;심용걸;김희중;최용;정준기;이명철;고창순
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권3호
    • /
    • pp.291-299
    • /
    • 1997
  • As a microimaging device detecting gamma rays emitted from small lesions or tumors during operation, the intraoperative surgical probe has been proposed and is now under development. We have designed a multipurpose portable gamma prove system and evaluated the performance both for the absolute counting purpose of residual radioactivities and for the localizing capability of gamma events using the NaI(Tl) crystal and two types of photomultiplier tubes(PMTs). Counting efficiencies in the range of routine clinical use of radiation dose were measured using the assembly of single channel PMTs and 0.5 inch thick NaI(Tl) crystal of 1 inch diameter. The positioning of gamma events for imaging purpose requires the multiple channel PMTs with appropriate positioning electronics. We have designed a simple and reliable positioning circuit based on the concept of modified Anger. In preliminary experiments using the multiple channel PMT of 3 inch diameter and the dim lighth source, we were able to trace and localize the correct position with reduced positioning error by the use of two multiplier/divider chipset and simplified peripherals. The energy resolutions for the counting gamma probe measured as full width at half maximum(FWHM) for Cs-137, F-18, Tc-99m were 12%, 13%, and 36%, respectively. The spatial resolution for the imaging gamma probe measured as FWHM for green LED was 2.9 mm. The results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine. Future studies will include developing collimators, improving interface hardwares, and evaluating the system with clinical data.

  • PDF

온도 차이에 따른 수영훈련이 결핵균 감염정도에 미치는 영향 (Effects of Swim Training on Tuberculosis infection in the Mouse Model at Different Temperature)

  • 곽이섭
    • 생명과학회지
    • /
    • 제15권4호
    • /
    • pp.652-656
    • /
    • 2005
  • 본 연구를 통하여 규칙적인 수영 트레이닝이 체중의 감소를 일으켰으며(온수 및 냉수), 특히 냉수 훈련이 큰 감소를 나타내었다. 온수 훈련군에서는 $INF-\gamma$의 감소를 유발하여 림프구의 증식을 Th0에서 Th2 쪽으로 유도한다는 사실을 알 수 있었으며, 이로 인해 결핵균을 감염시켰을 경우 오히려 폐와 비장에서 결핵균의 수가 현저히 증가하는 사실을 알 수 있어, 수영 훈련군에게서의 결핵균 감염 시 대조군에 비해 균수가 현저히 증가함을 알 수 있었다. 하지만 냉수 훈련군에서는 통제군에 비해 $INF-\gamma$의 현저한 증가를 보여, 결핵균 감염 시 폐에서 결핵균 수가 감소함을 확인 할 수 있었다.

$BaTiO_3$-PVDF 복합체로 제작한 무기 EL 소자 (Inorganic Electro-luminescence Device Fabricated with $BaTiO_3$-PVDF Composite Film)

  • 손용호;정준석;조찬우;우덕현;김영민;김성진;윤만순;류성림;권순용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.299-299
    • /
    • 2007
  • 후막형 무기 EL (electro-luminescence) 소자는 제조공정이 간단하고, 얇고, 가볍고, 유연한 동의 많은 장점들 때문에 휴대폰의 키패드 (key-pad) 및 광고용 back-light용으로 사용되고 있다. 이 무기 EL 소자는 비교적 손쉬운 스크린 프린팅 (screen-printing) 법으로 대면적을 제작할 수 있지만, LED (light emitting diode) 등과 비교하여 밝기가 낮아서 그 응용 분야가 제한되고 있다. EL 소자의 형광층은 전면 전극과 후면 전극 사이에 위치한다. EL은 이 형광층에 고 전기장이 걸릴 때, 전기장에 의해 가속된 전자가 형광층 내부에 첨가된 발광 중심의 전자를 여기시키고, 여기된 전자가 다시 바닥상태로 완화될 때 빛이 방출되는 현상이다. 즉, EL 소자는 이러한 전자 발광 현상을 이용한 소자로서, 전압 인가 시 발광 면 전체가 균일하게 발팡하는 평면 광원이다. 이러한 EL 소자에서 휘도의 증가는 후면 전극과 형광층 사이에 삽입되는 유전체 층의 특성과 밀접한 연관성이 있다. 본 연구에서는 고휘도 무기 EL 소자를 제작하기 위하여 이 유전체 층의 특성과 소자의 성능 사이의 관계를 알아보고자 하였다. 유전체 층에 사용하기 위해서 $BaTiO_3$-PVDF (polyvinylidene fluoride)의 복합체 필름을 제조하였다. 먼저 이 복합체 필름을 스크린 프린팅 (screen printing) 법으로 코팅하기 위한 페이스트 제작을 위해서, PVDF 수지를 용제에 녹였다. 그 다음, 일반 혼합기 및 삼단 롤밀 혼합기 (3-roll milling mixer) 등을 이용하여 $BaTiO_3$ 분말과 PVDF 용액을 다양한 비율로 혼합하여 페이스트를 제조하였다. ITO가 증착된 PET Film에 스크린 프린팅 법을 사용하여 형광층, 유전층, 배면 전극 등을 차례로 코팅하였다. $BaTiO_3$ (BT) 분말과 복합체 필름의 XRD 분석 결과, 분말 시료와 복합체 시료 모두 페로브스카이트 구조의 BT 회절선만 관찰되었다. 복합체의 단면 SEM 관찰에서는, BT 분말의 무게비가 증가할수록 더 치밀한 구조를 보여줌을 확인하였다. 또 EL소자의 유전상수와 휘도도 BT 분말의 혼합비가 증가할수록 증가하였다. 본 연구에서 제작한 무기 EL 소자의 최대 휘도는 약 $130\;cd/m^2$ 정도로 측정되었는데, 이는 휴대폰 키패드의 back-light용 광원으로 사용하기 충분하다고 판단되어진다.

  • PDF

실험적 외상성 뇌손상모델에서 외상 후 저체온법의 효과 - TUNEL과 β-APP Immunohistochemical Stain - (Effects of Posttraumatic Hypothermia in an Animal Model of Traumatic Brain Injury(TBI) - Immunohistochemical Stain by TUNEL & β-APP -)

  • 안병길;하영수;현동근;박종운;김준미
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권4호
    • /
    • pp.461-470
    • /
    • 2000
  • Objective : Many investigators have demonstrated the protective effects of hypothermia following traumatic brain injury(TBI) in both animals and humans. It has long been recognized that mild to moderate hypothermia improves neurologic outcomes as well as reduces histologic and biochemical sequelae after TBI. In this study, two immunohistochemical staining using terminal deoxynucleotidyl-transferase-mediated biotin dUTP nick end labeling(TUNEL), staining of apoptosis, and ${\beta}$-amyloid precursor protein(${\beta}$-APP), a marker of axonal injury, were done and the authors evaluated the protective effects of hypothermia on axonal and neuronal injury after TBI in rats. Material and Method : The animals were prepared for the delivery of impact-acceleration brain injury as described by Marmarou and colleagues. TBI is achieved by allowing of a weight drop of 450gm, 1 m height to fall onto a metallic disc fixed on the intact skull of the rats. Fourty Sprague-Dawley rats weighing 400 to 450g were subjected to experimental TBI induced by an impact-acceleration device. Twenty rats were subjected to hypothermia after injury, with their rectal temperatures maintained at $32^{\circ}C$ for 1 hour. After this 1-hour period of hypothermia, rewarming to normothermic levels was accomplished over 30-minute period. Following 12 hours, 24 hours, 1 week and 2 weeks later the animals were killed and semiserial sagittal sections of the brain were reacted for visualization of the apoptosis and ${\beta}$-APP. Results : The density of ${\beta}$-APP marked damaged axons within the corticospinal tract at the pontomedullary junction and apoptotic cells at the contused cerebral cortex were calculated for each animal. In comparison with the untreated controls, a significant reduction in ${\beta}$-APP marked damaged axonal density and apoptotic cells were found in all hypothermic animals(p<0.05). Conclusion : This study shows that the posttraumatic hypothermia result in substantial protection in TBI, at least in terms of the injured axons and neurons.

  • PDF

Prototype Development of a Three-wheel Riding Cultivator and Its Basic Performance

  • Lee, Beom Seob;Yoo, Soonam;Lee, Changhoon;Choi, Il Su;Choi, Yong;Yun, Young Tae
    • Journal of Biosystems Engineering
    • /
    • 제43권4호
    • /
    • pp.285-295
    • /
    • 2018
  • Purpose: The aim of this study is to develop a three-wheel riding cultivator for improving the performance of the current four-wheel riding cultivators in the market. Methods: A prototype three-wheel riding cultivator with the rated power of 15.5-kW, a primary hydrostatic and a two-speed selective gear transmission shifts, front/rear three-wheel drive, a hydraulic wheel tread adjustment, and the mid-section attachment of the major implements was designed and constructed. Its specifications and basic performance are investigated. Results: The maximum speeds of the prototype at the low and high stages were measured to be approximately 7.31, and 11.29 km/h in forward travel, respectively, and approximately 3.60, and 6.37 km/h in rearward travel, respectively. The minimum ground clearance is shown to be 670 mm. The rotating speeds of the power takeoff (PTO) shaft at the low and high stages are shown to be approximately 795 and 1,140 rpm, respectively. The tread of the rear wheels, the minimum radius of turning, and the maximum lifting height of the parallel link device are measured to be within 1,320-1,720 mm, 2.80 m, and 390 mm, respectively. Approximately 25.3% and 74.7% of the total weight of the prototype are distributed in the front and rear wheels on flat ground, respectively. When the tread of rear wheels increased from 1,320 to 1,720 mm, the left and right static lateral overturning angles increased from $33.4^{\circ}$ to $39.1^{\circ}$ and from $29.0^{\circ}$ to $36.1^{\circ}$, respectively. Conclusions: The prototype three-wheel riding cultivator showed a wide range of travel and PTO speeds, high minimum ground clearance, small minimum radius of turning, and easy control of the rear wheel tread. Further, the easy observation of cultivating operations by mid-mounting the implements can improve quality of work. Therefore, the prototype is expected to contribute to the riding mechanization of cultivating operations for various upland crops in Korea.

유방촬영용장치 부가필터에 따른 선량변화 및 화질개선 (Change of Dose Exposure and Improvement of Image Quality by Additional Filtration in Mammography)

  • 조우일;김영근;이길동
    • Journal of Radiation Protection and Research
    • /
    • 제38권2호
    • /
    • pp.78-90
    • /
    • 2013
  • 최근 방사선 피폭에 대한 관심이 높아지고 있다. 유방촬영용장치의 방사선 피폭은 일반 X선 촬영에 비해 비교적 흡수선량이 높기 때문에 화질은 개선하되 불필요한 피폭을 줄여야 노력을 할 필요가 있다. 최근 국제방사선방어위원회(ICRP)나 우리나라의 한국의료영상품질관리원(KIAMI)에서 권고하는 평균유선선량은 3 mGy이하이지만 이는 유방의 두께에 따라 다르므로 모든 경우에 권고수치가 넘지 않는다고 해서 적다고 말할 수는 없다. 일반적으로 방사선 촬영에 사용되는 선질은 영상의 화질과 피폭선량을 결정하는 중요한 인자로 촬영 관전압과 부가필터에 영향을 받는다. 일반적으로 유방촬영용장치에서 방출되는 X선 에너지는 연속 스펙트럼(spectrum)으로서 영상의 화질에 미치는 영향이 적은 저 에너지부터 이미지상의 대조도(contrast)를 저해하는 고 에너지 성분까지 포함하고 있다[1,3]. 현재 유방촬영용장치에 많이 사용되고 있는 부가필터는 몰리브덴(molybdenum, Mo), 로듐(rhodium, Rh)등이 있으며, 이는 사용되어지는 X선질의 에너지 영역에 따라 구분하여 사용되고 있다. 현재 유방촬영용장치에 가장 많이 사용되어지고 있는 부가필터의 물질인 몰리브덴(Molybdenum, Mo), 로듐(rhodium, Rh)외에 원자번호와 K-흡수단 영역이 비슷한 니오븀(niobium, Nb)이나 지르코늄(zirconium, Zr)재질의 부가여과판을 사용 하였을때 화질과 선량의 개선된 변화를 알아보고, X선의 저에너지를 흡수할 수 있는 알루미늄(aluminum, Al)재질을 복합으로 사용하였을 때 유방촬영용장치의 화질에 손실없이 알루미늄(aluminum, Al)두께에 따른 조사선량의 경감 정도를 확인하려 한다. 본 실험에서는 몰리브덴(molybdenum, Mo), 니오븀(niobium, Nb), 지르코늄(zirconium, Zr)등의 부가필터를 종류별로 단일필터로 사용할 경우와 이들 단일필터에 알루미늄(aluminum, Al)필터를 복합으로 사용한다. 이 경우 상기 부가필터의 종류에 따른 화질의 개선이 될 것으로 판단되고, 알루미늄(aluminum, Al)필터를 복합으로 사용함으로 인해 저 에너지의 불필요한 X선이 흡수되므로 동일한 농도가 되었을 때 화질에 큰 영향없이 선량이 감소될 것으로 기대된다.

급성 심근경색으로 인한 심인성 쇼크 환자에 대한 경피적 순환 보조장치($EBS^{(R)}$) 적용의 초기경험 (Initial Experience of the Emergency Bypass System ($EBS^{(R)}$) for the Patients with Cardiogenic Shock due to an Acute Myocardial Infarction)

  • 류경민;김삼현;서필원;류재욱;김석곤;김영화;박성식
    • Journal of Chest Surgery
    • /
    • 제41권3호
    • /
    • pp.329-334
    • /
    • 2008
  • 배경: 경피적 순환 보조장치는 다른 수단으로는 소생이 불가능한 심인성 쇼크 환자에 있어서 매우 효과적인 생명유지 장치이다. 특히 심근경색 및 고위험군의 관상동맥중재술, 심장수술 후 심인성 쇼크 등 다양한 임상상황에서 사용되며, 사용이 손쉬운 장점을 가지고 있다. 저자들은 급성 심근경색으로 입원한 환자 중 심인성 쇼크가 발생하여 경피적 순환 보조장치를 사용한 환자들의 초기경험을 분석하였다. 대상 및 방법: 2005년 1월부터 2006년 12월까지 급성 심근경색에 의한 심인성 쇼크 환자 8명에게 경피적 순환 보조장치(CAPIOX emergent bypass system, $EBS^{(R)}$, Terumo Inc., Tokyo, Japan)를 적용하였다. Seldinger방법을 사용하여 대퇴정맥에 20Fr의 유입관을 우심방까지 거치하고, 대퇴동맥에 16Fr의 유출관을 거치하면서 동시에 자가 충진을 완료하였다. 혈류량을 $2.5{\sim}3.0L/min/m^2$으로 유지하였고, 헤파린을 정주하면서 ACT를 200초 이상으로 유지하였다 결과: 환자의 평균나이는 $61.1{\pm}14.2$세($39{\sim}77$세)였다. 관상동맥중재술(PCI) 시행 이전에 거치한 경우가 3예, 중재술 도중 발생하여 거치한 경우가 3예, 중재술 후가 1예, 관상동맥우회술 후가 1예였다. 평균 $EBS^{(R)}$가동시간은 $47.5{\sim}27.9$시간$(8{\sim}76$시간)이었으며, 이 중 $EBS^{(R)}$ 이탈이 가능하였던 경우가 5명(62.5%)으로 이들은 모두 퇴원이 가능하였다. $EBS^{(R)}$적용으로 인한 합병증은 모두 3예로 급성 신부전이 2예, 위장관 출혈이 1예 있었다. 사망한 3명의 환자 중 2명은 $EBS^{(R)}$ 적용 전 심정지가 와 있었던 경우였으며, 1명은 난치성 심실세동이 있었던 경우였다. 퇴원한 환자는 모두 생존하여 평균 $16.8{\pm}3.1$개월($12{\sim}20$개월)째 외래 추적관찰 중이다. 결론: 다른 방법으로 소생이 힘든 급성 심근경색으로 인한 심인성 쇼크 환자에게 $EBS^{(R)}$를 적용함으로써 환자의 생명을 구할 수 있었고, 일단 회복된 환자들은 별다른 후유증 없이 생존하였다. 향후 $EBS^{(R)}$의 적절한 적용시기와 적용방법에 대해서는 보다 많은 경험 및 임상연구가 필요할 것으로 생각된다.

국내 치과방사선의 현황 및 이용 실태 (The Actual State and the Utilization for Dental Radiography in Korea)

  • 신귀순;김유현;이보람;김세영;이귀원;박창서;박혁;장계용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.109-120
    • /
    • 2010
  • 치과 X선 검사 시 환자선량의 권고량 가이드라인을 개발하기 위해서 우선 국내 치과방사 선의 현황 및 이용 실태를 설문조사하여 비교분석하였다. 응답을 받은 77곳의 치과병 의원 중에서 치과대학이 있는 치과대학병원을 A그룹(11곳), 치과대학이 없는 대학병원을 포함한 치과병원을 B그룹(30곳), 치과의원을 C그룹(36곳)으로 분류하였다. 그룹별로 분석한 결과는 다음과 같았다. 치과병 의원 한 곳당 평균 unit chairs수는 A그룹 140.2개, B그룹 15.3개, C그룹 5.8개, 평균치과의사수는 A그룹 112.6명, B그룹 7.3명, C그룹 1.7명, 평균방사선사수는 A그룹 3.1명, B그룹 0.5명, C그룹에는 한 명도 없었고, 평균치과위생사수는 A그룹 19.7명, B그룹 12.5명, C그룹 3.3명이었다. 설치된 치과용 X선장치의 평균보유수는 A그룹 14.64대, B그룹 3.21대, C그룹 2.19대로 나타났다. 이 중에서 구내촬영장치가 가장 많았고, 다음은 파노라마 장치, 세팔로 장치, CBCT 장치 순이었으며, 장치시스템의 비율은 세 그룹 모두 DR 시스템이 50% 이상으로 가장 많았다. 필름 시스템인 경우, 사용된 구내필름은 감광도가 높은 Insight 필름(Kodak, USA)이 대부분이었으며, 자동 현상기는 사용하는 곳이 적었으나, 필름유지기구는 사용하는 곳이 약간 많았다. PACS 이용률은 A그룹 90.9%, B그룹 83.3%, C그룹 16.7%이었고, 프로그램은 국내의 Infinitt에서 개발된 PiView STAR가 가장 많이 이용되고 있었다. 치과병 의원 한 곳당 2008년도의 연간 평균촬영건수는 A그룹이 B그룹보다 6.8배, C그룹보다 21.2배 더 많았으며, 구내 치근단 촬영과 파노라마 촬영이 대부분이었다. 구내 치근단 촬영 시 관전압과 관전류는 세 그룹 모두 비슷하였으나, 노출시간은 C그룹이 A그룹의 12배, B 그룹의 3.5배 정도 길었다. 즉, 대부분 치과위생사가 촬영하고 있는 C그룹에서는 방사선 노출량이 다른 그룹에 비해 훨씬 많았다. 그러나 파노라마촬영 시의 조건은 세 그룹에서 큰 차이가 없었다. 결론적으로, 촬영조건은 경험적 지식을 따르기보다는 권장량을 사용해야 하며, 필름시스템에서는 자동현상기와 필름유지기구를 사용하여 방사선의 노출량을 줄여준다. 또한 환자선량의 감소와 X선 영상의 질 향상을위해서 X선발생장치 및 관련기기의 체계적인 정도관리가 반드시 필요하다.

손가락 빨기로 인한 부정교합의 치험례 (TREATMENT OF MALOCCLUSION, AS RELATED TO FINGER SUCKING : CASE REPORT)

  • 문상진;최영철
    • 대한소아치과학회지
    • /
    • 제31권1호
    • /
    • pp.1-10
    • /
    • 2004
  • 손가락 빨기는 유아의 심리적인 욕구와 영양적인 욕구에서 유발되어 흔히 $2{\sim}3$세까지는 정상적으로 간주된다. 이 시기까지의 상, 하악골과 교합을 포함하는 치열궁에의 영향은 습관의 중단과 함께 자연적으로 개선되는 경향을 보이는 것으로 알려져 있다. $3.5{\sim}4$세 이후까지 손가락 빨기가 지속된 경우, 이로 인해 유발된 부정교합의 정도가심하고 상, 하악골 발달의 부조화가 현저하며 자연적인 개선을 예측하기 어려울 때에는 적극적인 치료를 시행하는 것이 바람직하다. 습관의 중단 및 습관으로 인한 부정교합과 심한 골격적 부조화를 해소하기 위해 $Fr\ddot{a}nkel$ appliance는 매우 효과적인 장치이다. 본 증례는 경희대학교 치과병원 소아치과에 내원한 환아 중 손가락 빨기로 인한 심한 수평피개도와 상, 하악골 발달의 부조화, 심하게 함몰된 안모를 가진 3세 어린이와 정중선 변위, 안면 비대칭, 편측성 구치부 반대 교합을 지닌 4세 어린이에서 습관의 중단과 부정 교합의 치료를 위해 $Fr\ddot{a}nkel$ appliance를 이용해 치료하였다. 환아들은 $Fr\ddot{a}nkel$ appliance를 장착한 이후에 습관이 바로 중단되었으며 증례 1 에서는 심한 수평피개도와 상, 하악골의 부조화가 FR-II 장착 16개월 후 개선되었다. 증례 2 에서는 정중선의 변위, 하악골의 편위, 편측성 구치부 반대교합 안모 비대칭이 FR-III 장착 10개월 후 개선되었다. $Fr\ddot{a}nkel$ appliance는 골격적 부조화의 개선 및 Habit breaker로서 추천할 만한 장치이다. time이 짧았다. 36개월 이상인 환아는 $N_2O/O_2$를 사용하여 수면을 유도하는 경우가 많았다. 연령과 $N_2O/O_2$ 사용시간, $N_2O/O_2$사용과 치료시간사이에는 상관관계가 존재한 반면, 체중과 $N_2O/O_2$사용시간사이에는 상관관계가 없었다. 치료시간 연장, $N_2O/O_2$사용여부와 부작용 발생간에서 는 통계학적으로 유의한 차이는 확인되지 않았다.^{(R)}$를 도포한 후 중합한 군이 산소억제층의 두께가 평균 49%의 감소되었으며(p<0.05), 이들 산소를 차단한 군 간의 유의차는 없었다.며 CYP1A2유전자형에 따른 영향은 관찰할 수 없었다. CYP1A2유전자형에 따른 생체내 대사능을 관찰하는 실험이 향후 이루어 져야 할 것으로 사료된다.san film보다 큰 수증기 투과도를 보였다.적으로 유의한 차이를 보이지 않았다.y tissue layer thinning은 3 군모두에서 관찰되었고 항암 3 일군이 가장 심하게 나타났다. 이상의 실험결과를 보면 술전 항암제투여가 초기에 시행한 경우에는 조직의 치유에 초기 5 일정도까지는 영향을 미치나 7 일이 지나면 정상범주로 회복함을 알수 있었고 실험결과 항암제 투여후 3 일째 피판 형성한 군에서 피판치유가 늦어진 것으로 관찰되어 인체에서 항암 투여후 수술시기는 인체면역계가 회복하는 시기를 3주이상 경과후 적어도 4주째 수술시기를 정하는 것이 유리하리라 생각되었다.한 복합레진은 개발의 초기단계이며, 물성의 증가를 위한 연구가 필요할 것으로 사료된다.또 다른 약물인 glycyrrhetinic acid($100{\mu}M$)도 CCh 자극으로

  • PDF

선형가속기의 품질관리를 위한 2차원이온전리함배열의 유용성 (Feasibility of Two Dimensional Ion Chamber Array for a Linac Periodic Quality Assurance)

  • 이정우;홍세미;박병문;강민영;김유현;서태석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.183-188
    • /
    • 2008
  • 본 연구의 목적은 방사선치료용 선형가속기의 품질관리를 수행하기 위한 2차원이온전리함배열의 유용성을 검증하기 위함이다. 물팬톰과 필름으로 수행하던 기존의 품질관리 방법을 2차원이온전리함배열(MatriXX, Wellhofer Dosimetrie, Germany)을 이용하여 유용성을 검증하였다. MatriXX는 1,020개의 평판형 전리함(용적: $0.08\;cm^3$, 직경: 4.5mm, 높이: 5mm, 배열간격: 7.62mm)이 일정한 간격으로 $24{\times}24\;cm^2$의 면적에 배열 되어있다. MatriXX의 유용성을 검증하기 위해 연속된 5개월에 걸쳐 선량균등도, 에너지($TPR_{20,10}$), 그리고 절대 선량을 측정하여 물팬톰과 $0.65\;cm^3$ (FC65G, Wellhofer Dosimetrie, Germany) Farmer형 이온전리함을 통해 얻은 값과 비교, 분석하였다. MatriXX 측정 시 폴리스틸렌 고체 팬톰(${\rho}:\;1.18\;g/cm^3$)을 이용하였으며, MatriXX 고유의 커버 물질의 밀도와 두께(${\rho}:\;1.06\;g/cm^3$, t: 0.36 cm)를 물과 등가의 값으로 환산하여 적용하였다. 또한, 기하학적 점검을 위한 예비실험에서 콜리메이터의 회전축과 하프빔의 접합부를 필름측정의 결과와 비교하였다. 선량계측학적 실험 결과, MatriXX로 얻은 데이터와 물팬톰의 결과가 모든 항목에서 ${\pm}1%$ 이내의 일치를 보였다. 기하학 품질관리의 예비 실험 결과 기존의 필름방식과 유사한 결과를 얻었으며, 기하학적 품질관리의 정량적 분석 가능성을 제시하였다. 본 연구를 통해 주기적인 선형가속기의 품질관리에서 물팬톰과 필름을 대체할 수 있는 MatriXX의 유용성을 확인하였으며, 향후 비용절감과 시간과 인력을 절감할 수 있는 품질관리의 새로운 방법을 제시하였다.

  • PDF