• 제목/요약/키워드: M1 polarization

검색결과 647건 처리시간 0.036초

전기화학적 방법에 의한 타이타늄 분극특성 및 나노메쉬 형성 (Characteristics of titanium polarization curve and formation of nanomesh by electrochemical method)

  • 박진서;김부섭
    • 대한치과기공학회지
    • /
    • 제38권2호
    • /
    • pp.79-84
    • /
    • 2016
  • Purpose: The aim of this study was to make nanomesh on the surface of titanium by potentiostatic technique which was done at the suitable potential level. Methods: In order to find the suitable potential level, use a $25^{\circ}C$ NaCl, NaOH and NH4F solution of 1 M and 5 M as supporting electrolyte, working electrode(positive potential) was contact to the titanium specimen and counter electrode(negative potential) was contact to the Pt substrate. At the transpassive potential which was observed by potentiostatic technique, potentiostatic technique was done for 2hours. Results: As a result, 1 M NaOH solution was suitable as a supporting electrolyte, potentiostatic technique used a $25^{\circ}C$ NaOH solution of 1 M for 2hours, nanomesh was formed. Conclusion: The potentiostatic technique was used $25^{\circ}C$ NaOH solution of 1 M and 5 M as supporting electrolyte for 2hours. Nanomesh was built more uniform and fine in 1 M NaOH solution than 5 M NaOH solution.

복강대식세포의 염증성 표현형에 대한 곰피(Ecklonia stolonifera) 유래 Phlorotannins의 효과 (Effect of Phlorotannins Isolated from the Ethyl Acetate Fraction of Ecklonia stolonifera on Peritoneal Macrophage Polarization)

  • 최민우;최준형;김형락;김재일
    • 한국수산과학회지
    • /
    • 제48권4호
    • /
    • pp.439-446
    • /
    • 2015
  • Inflammation is a protective response to infection or injury. However, prolonged inflammation can contribute to the pathogenesis of many diseases, such as cancer, diabetes, arthritis, atherosclerosis, and Alzheimer's disease. Recent studies have shown that activated macrophages, inflammatory effector cells, can react to tissue insults in a polarized manner, in which their phenotypes are polarized into two major subtypes, categorized as M1 or M2. Classical M1 activation involves the production of pro-inflammatory cytokines, such as interleukin (IL)-6 and tumor necrosis factor (TNF)-${\alpha}$, and free radicals, while M2 or alternative activation is an anti-inflammatory phenotype involved in homeostatic processes, such as wound healing, debris scavenging, and the dampening of inflammation via the production of very low levels of pro-inflammatory cytokines and high levels of anti-inflammatory mediators, including IL-10. As part of our ongoing effort to isolate anti-inflammatory compounds from seaweeds, we investigated the effects of phlorotannins isolated from the brown alga Ecklonia stolonifera on macrophage polarization. Mouse peritoneal macrophages were treated with various concentrations of the extracts, and real-time RT-PCR analyses were performed to examine the expression of polarization markers: IL-$1{\beta}$, IL-6, and TNF-${\alpha}$ for M1 and arginase-1, peroxisome proliferator-activated receptor (PPAR)-${\gamma}$, found inflammatory zone-1 (Fizz-1), chitinase 3-like 3 (Ym1), and$Kr{\ddot{u}}ppel$-like factor 4 (Klf-4) for M2. The pretreatment of cells with eckol, dieckol, and phlorofucofuroeckol-A (PFF-A), isolated from the ethyl acetate fraction of E. stolonifera ethanolic extract, potentiated the anti-inflammatory M2 phenotype of the macrophages. These results indicate that phlorotannins derived from E. stolonifera can be used to enrich macrophages with markers of the M2 anti-inflammatory state.

Effect of iron on the proteolytic activity of live Uronema marinum (Ciliata: Scoticociliatida) measured by fluorescence polarization

  • 이은혜;권세련;최승혁;김기홍
    • 한국어병학회지
    • /
    • 제19권1호
    • /
    • pp.83-86
    • /
    • 2006
  • Effect of iron on the extracellular proteolytic activity of live Uronema marium was determined by fluorescence polarization (FP) method. Supplementation of 0.5 and 5.0 μM iron significantly increased caseinolytic activity of live U. marinum. In contrast, supplementation of 50 μM iron showed no significant differences in FP values compared to the control. The present result suggests that iron in cultured water or skin tissue of olive flounder may influence on the penetration and establishment of U. marinum, correlating with modulation of extracellular protease activity of the ciliates.

VAD 공법을 이용한 판다형 편광유지광섬유 제조 및 특성평가 (Fabrication and characteristics evaluation of Panda polarization-maintaining fibers by VAD method)

  • 최성순;구석수;정창현;이경구;오치환;유기선;조민식;권오선;최우석;송기원
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2008년도 하계학술발표회 논문집
    • /
    • pp.425-426
    • /
    • 2008
  • The Panda-type polarization maintaining fibers were fabricated by VAD(vapor-phase axial deposition) method. We fabricate Panda style polarization maintaining fibers that have small form factor($80{\mu}m$), high H-parameter of about $1{\times}10^{-4}/m$ and low optical loss of about 3dB/km.

  • PDF

냉난방용 배관 용접부의 전기화학적 부식특성에 관한 연구 (A Study on Characteristics of the Electrochemical Corrosion of Weld Zone for Refrigerating and Heating Systems Pipe)

  • 임우조;윤병두;김환식
    • 수산해양교육연구
    • /
    • 제19권1호
    • /
    • pp.84-90
    • /
    • 2007
  • This paper was studied on the electrochemical corrosion characteristics of weld zone for refrigerating and heating systems pipe. Austenitic stainless steel is widely applied to various fields of industry, because it is good to corrosion resistance and mechanical properties. But STS 304 is reliable to sensitization by heat cycle on welding. Therefore, in this study, electrochemical polarization test of STS 304 steel pipe manufactured by arc welding in tap water was carried out. And then polarization resistance behavior, uniform and local corrosion behaviors of base metal(BM), weld metal(WM) and heat affected zone(HAZ) for STS 304 pipe were investigated. The corrosion current density of STS 304 steel pipe is high in order of BM(153nA/cm2) < WM(614nA/cm2) < HAZ ($1.675{\mu}A/cm2$). The pitting potential of HAZ(238mV/SCE) for STS 304 is lower than BM(1206mV/SCE) and WM(369mV/SCE). Therefore, the local corrosion like pitting corrosion, galvanic corrosion and crevice corrosion of HAZ for STS 304 is more sensitive than BM and WM.

Comparative Study on Conductivity and Moisture Content Using Polarization and Depolarization Current (PDC) Test for HV Insulation

  • Jamail, N.A.M.;Piah, M.A.M.;Muhamad, N.A.;Kamarudin, Q.E.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권1호
    • /
    • pp.7-11
    • /
    • 2014
  • The Polarization and Depolarization Current (PDC) measurement is an efficient and effective diagnostic technique based on time domain measurement, for evaluating the high voltage insulation condition. This paper presents a review and comparison results from several published papers on the application of the PDC method to finding the conductivity and moisture content of various types of insulators. For solid insulation, the study was focused on cable insulation, electric machine stator insulation, and paper insulator in transformer insulation with different conditions. For liquid insulation, the review and comparison was done on biodegradable and mineral transformer oils, with fresh oil condition, and aged condition. The results from previous researchers tests were complied, analyzed and discussed, to evaluate the application of the PDC method to monitor the conductivity and moisture of HV equipment insulation systems. From the review results, the PDC technique successfully gives an indication of the conductivity and moisture level of high voltage insulation.

임팩션 효과에 편극전하 방식을 부가한 다층 다단 다공성 플레이트 시스템의 집진특성 (Dust Collection Characteristics of Multi-layer Multi-stage Porous Plate System with Polarization Charge to Impaction Effect)

  • 김보배;김일규;여석준
    • 대한환경공학회지
    • /
    • 제33권8호
    • /
    • pp.598-605
    • /
    • 2011
  • 본 연구의 주 목적은 다층 다단 다공성 시스템에 편극전하 방식을 부가하여 본 시스템의 집진특성을 실험적으로 해석하는데 있다. 본 시스템의 압력손실 및 집진효율 특성 해석을 위해 실험은 인가전압, 시스템 유입유속, 유입농도 및 stage 수 등의 실험적 변수들에 의해 수행된다. 실험결과, 기류유입 시 유입유속 $v_{in}$ = 3.11 m/s에서 단(stage) 수 변화($1{\rightarrow}5$단)에 따라 압력손실은 $18{\sim}134mmH_2O$를 나타낸다. 인가전압 0 kV 및 기류유입이 없을 때, 시스템 유입유속 $v_{in}$ = 2.58 m/s인 경우 5 stage에서 집진효율은 92.5% 인 데 비해, 동일 유속에서 플레이트 별 편극전하(alternating polarization charge-applied voltage 2.5 kV) 및 기류유입 시스템인 경우 5 stage 효율은 98.5%로 전자에 비해 6% 정도 매우 높은 효율 상승을 보인다.

Monitoring of Gamma-ray Bright AGN : The Multi-Frequency Polarization of the Flaring Blazar 3C 279

  • Kang, Sincheol;Lee, Sang-Sung;Byun, Do-Young
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.65.1-65.1
    • /
    • 2016
  • We present results of long-term multi-wavelength polarization observations of the powerful blazar 3C 279 after its ${\gamma}$-ray flare on 2013 December 20. We followed up this flare by means of single-dish polarization observations with two 21-m telescopes of the Korean VLBI Network, carried out weekly from 2013 December 25 to January 11, and at 22, 43, and 86 GHz, simultaneously. These observations were part of the Monitoring Of GAmma-ray Bright AGNs (MOGABA) program. We Measured 3C 279 total flux densities at 22, 43, and 86 GHz, showing a mild variability of a factor of ${\leq}50%$ over the period of our observations. The spectral index ranged from -0.13 to -0.36 at between 22 and 86 GHz. The degree of linear polarization was in the range of 6 ~ 12 %, and slightly decreased with time at all frequencies. We found Faraday rotation measures (RM) of -300 to $-1200rad\;m^{-2}$ between 22 and 43 GHz, and -800 to $-5100rad\;m^{-2}$ between 43 and 86 GHz. The RM values follow a power law ${\mid}RM{\mid}{\propto}{\nu}^{\alpha}$, with a mean ${\alpha}$ of 2.2, implying that the polarized emission at these frequencies travels through a Faraday screen in or near the jet. We conclude that the regions emitting polarized radio emission may be different from the region responsible for the 2013 December ${\gamma}$-ray flare, and that these regions are maintained by the dominant magnetic field perpendicular to the direction of the radio jet at milliarcsecond scales.

  • PDF

$(Pb_{1-x}Ca_x)ZrO_3$$(Pb_{0.63},Ca_{0.37-x}M_x)ZrO_3$ 세라믹스의 고주파 유전 특성 (Microwave Dielectric Properties of $(Pb_{1-x}Ca_x)ZrO_3$ and $(Pb_{0.63},Ca_{0.37-x}M_x)ZrO_3$ (M = Mg, Sr) Ceramics)

  • 윤중락;이헌용
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권6호
    • /
    • pp.533-540
    • /
    • 1997
  • The microwave dielectric properties of ((P $b_{1-x}$ C $a_{x}$)Zr $O_3$ and (P $b_{0.63}$,C $a_{0.37-x}$ $M_{x}$)Zr $O_3$(M=Mg,Sr) ceramics were investigated. In (P $b_{1-x}$ C $a_{x}$)Zr $O_3$ (X=0.33~0.40) ceramics, high quality factor and small temperature coefficient of resonant frequency were obtain in (P $b_{0.63}$C $a_{0.37}$)Zr $O_3$with perovskite structure. In the case of (P $b_{0.63}$C $a_{0.37-x}$M $g_{x}$)Zr $O_3$ dielectric constant temperature coefficient of resonant frequency increased and quality factor decreased due to increase of polarization of A-O bonding. When replacing Ca ion with Sr ion with large ion radius, polarization decreased with increased of bonding length and thus dielectric constant and temperature coefficient of resonant frequency decreased.decreased.creased.

  • PDF

대구경 광섬유 엔드캡 제작장비 개발 (Development of Fiber-end-cap Fabrication Equipment)

  • 이성헌;황순휘;김태균;양환석;윤영갑;김선주
    • 한국광학회지
    • /
    • 제32권2호
    • /
    • pp.49-54
    • /
    • 2021
  • 본 논문에서는 고출력 광섬유 레이저의 핵심 부품인 대구경 광섬유 엔드캡을 제작하는 장비를 설계 및 제작하였으며, 제작장비를 이용하여 대구경 광섬유 엔드캡을 제작하였다. 대구경 광섬유 엔드캡 제작장비는 레이저 광을 조사하여 접속 열원으로 사용하기 위한 CO2 레이저 광원부, 대구경 광섬유와 엔드캡의 위치를 이송하기 위한 정밀 스테이지 조립체, 스테이지 조립체와 연동되어 융착 시 정렬에 사용되는 비전 시스템으로 구성되어 있다. 레이저 광원의 출력은 스테이지 조립체와 연동되어 출력을 제어하며, 비전 시스템으로 대구경 편광유지 광섬유의 편광축을 정렬할 수 있도록 제작되었다. 자체 제작한 장비를 이용하여 클래드 직경이 400 ㎛인 대구경 편광유지 광섬유와 10(W)×5(D)×2(H) ㎣의 엔드캡을 레이저 융착하여 대구경 광섬유 엔드캡을 제작하였다. 제작된 대구경 광섬유 엔드캡의 신호광 삽입손실, 소광률 및 빔품질(M2)은 각각 0.6%, 16.7 dB, M2x=1.21, M2y=1.22로 측정되었다.