• Title/Summary/Keyword: M1 polarization

Search Result 647, Processing Time 0.028 seconds

DEVELOPMENT OF 230 GHZ RADIO RECEIVER SYSTEM FOR SRAO

  • Lee, Jung-Won;Kim, Chang-Hee;Kang, Hyunwoo;Lee, Bangwon;Han, Junghwan;Lee, Seok-Ho;Jeong, Il-Gyo;Koo, Bon-Chul;Park, Yong-Sun
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.6
    • /
    • pp.225-234
    • /
    • 2013
  • We develop a radio receiver system operating at ${\lambda}{\sim}1.3$ mm for the 6 m telescope of Seoul Radio Astronomy Observatory. It consists of a dual polarization receiver, a couple of IF processing units, two FFT spectrometers, and associated software. By adopting sideband-separating superconductor mixers with image band terminated to waveguide load at 4.2 K, we achieve $T_{RX}{\leq}100$ K and $T_{sys}$ less than 150 K at best weather condition over 210-250 GHz frequency range. The intermediate frequency signal of 3.5-4.5 GHz is down converted to 0-1 GHz and fed into the FFT spectrometers. The spectrometer covers 1 GHz bandwidth with a spectral resolution of 61 KHz. Test observations are conducted toward several radio sources to evaluate the performance of the system. Aperture and beam efficiencies measured by observing planets are found to be typically 44 ~ 59% and 47 ~ 61%, respectively over the RF band, which are consistent with those measured at 3 mm band previously.

Study on the Anti-inflammatory Effects of Soyangin-Hyeongbangpaedok-san (소양인 형방패독산의 함염증효과에 대한 실험적 연구)

  • Heo, Jeong-Won;Kang, Hee;Ahn, Kwang-Seok;Kim, Sung-Hoon;Choi, Seung-Hoon;Ahn, Kyoo-Seok;Shim, Bum-Sang
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.2
    • /
    • pp.443-451
    • /
    • 2009
  • Soyangin-Hyeongbangpaedok-san(SHBPDS) is used for treating upper respiratory infections, In an effort to investigate the anti-inflammatory effects of SHBPDS, we measured production of several cytokines and immunoglobulin in various immune cells. SHBPDS decreased the secretion of TNF-${\alpha}$, but not that of IL-6 in PMA/A23187 stimulated HMC-1 cells. As for mouse B cells, it induced proliferation and caused differential effects in expressions of surface IgE as determined by flow cytometry and secretions of IgE, IgG1, ILA and INF-${\gamma}$as measured by ELISA but showed little change in CD23 or CD69 expression. SHBPDS increased proliferation in anti-CD3/anti-CD28 stimulated CD4 Th cells. Under the Th1/Th2 polarization conditions, SHBPDS at 200 ${\mu}g/m{\ell}$ suppressed the secretion of INF-${\gamma}$ and IL-4. Based on the above results, we conclude that SHBPDS has antiinflammatory activities in mast cells and different immunomodulatroy effects in B cells and Th cells.

Impaired phagocytosis of apoptotic cells causes accumulation of bone marrow-derived macrophages in aged mice

  • Kim, Ok-Hee;Kim, Hyojung;Kang, Jinku;Yang, Dongki;Kang, Yu-Hoi;Lee, Dae Ho;Cheon, Gi Jeong;Park, Sang Chul;Oh, Byung-Chul
    • BMB Reports
    • /
    • v.50 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • Accumulation of tissue macrophages is a significant characteristic of disease-associated chronic inflammation, and facilitates the progression of disease pathology. However, the functional roles of these bone marrow-derived macrophages (BMDMs) in aging are unclear. Here, we identified age-dependent macrophage accumulation in the bone marrow, showing that aging significantly increases the number of M1 macrophages and impairs polarization of BMDMs. We found that age-related dysregulation of BMDMs is associated with abnormal overexpression of the anti-inflammatory interleukin-10. BMDM dysregulation in aging impairs the expression levels of pro-inflammatory cytokines and genes involved in B-cell maturation and activation. Phagocytosis of apoptotic Jurkat cells by BMDMs was reduced because of low expression of phagocytic receptor CD14, indicating that increased apoptotic cells may result from defective phagocytosis of apoptotic cells in the BM of aged mice. Therefore, CD14 may represent a promising target for preventing BMDM dysregulation, and macrophage accumulation may provide diagnostic and therapeutic clues.

Observation of Corrosion Behavior with Aluminum 5052 Alloy by Modulating Anodization Time (양극산화 공정시간에 따른 알루미늄 5052 합금의 산화피막 성장 및 내식성 관찰)

  • Ji, HyeJeong;Choi, Dongjin;Jeong, Chanyoung
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.67-67
    • /
    • 2018
  • The 5xxx series aluminum alloys are recently used in not only marine system but also automotive area because of a low density material, good mechanical properties and better resistance to corrosion. However, Aluminum alloys are less resistant than the purest aluminum such as 1xxx aluminum alloy. Electrochemical anodization technique has attracted in the area of surface treatment because of a simple procedure, a low-cost efficiency than other techniques such as lithography and a large volume of productivity, and so on. Here, The relationship between the corrosion behavior and the thickness of aluminum anodic oxide have been studied. Prior to anodization, The 5052 aluminum sheets ($30{\times}20{\times}1mm$) were degreased by ultra-sonication in acetone and ethanol for 10 minutes and eletropolished in a mixture of perchloric acid and ethanol (1:4, volume ratio) under an applied potential of 20V for 60 seconds to obtain a regular surface. During anodization process, Aluminum alloy was used as a working electrode and a platinum was used as a counter electrode. The two electrodes were separated at a distance of 5cm. The applied voltage of anodization is conducted at 40V in a 0.3M oxalic acid solution at $0^{\circ}C$ with appropriate magnetic stirring. The surface morphology and the thickness of AAO films was observed with a Scanning Electron Microscopy (SEM). The corrosion behavior of all samples was evaluated by an open-circuit potential and potentio-dynamic polarization test in 3.5wt% NaCl solution. Thus, The corrosion resistance of 5052 aluminum alloy is improved by the formation of an anodized oxide film as function of increase anodization time which artificially develops on the metal surface. The detailed electrochemical behavior of aluminum 5052 alloy will be discussed in view of the surface structures modified by anodization conditions such as applied voltages, concentration of electrolyte, and temperature of electrolyte.

  • PDF

Effect of Anodizing Current Density on Anti-Corrosion Characteristics for Al2O3 Oxide Film (Al2O3 산화 피막의 내식성에 미치는 양극산화 전류밀도의 영향)

  • Lee, Seung-Jun;Jang, Seok-Gi;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.153-153
    • /
    • 2016
  • Aluminum alloys have poor corrosion resistance compared to the pure aluminum due to the additive elements. Thus, anodizing technology artificially generating thick oxide films are widely applied nowadays in order to improve corrosion resistance. Anodizing is one of the surface modification techniques, which is commercially applicable to a large surface at a low price. However, most studies up to now have focused on its commercialization with hardly any research on the assessment and improvement of the physical characteristics of the anodized films. Therefore, this study aims to select the optimum temperature of sulfuric electrolyte to perform excellent corrosion resistance in the harsh marine environment through electrochemical experiment in the sea water upon generating porous films by variating the temperatures of sulfuric electrolyte. To fabricate uniform porous film of 5083 aluminum alloy, we conducted electro-polishing under the 25 V at $5^{\circ}C$ condition for three minutes using mixed solution of ethanol (95 %) and perchloric (70 %) acid with volume ratio of 4:1. Afterward, the first step surface modification was performed using sulfuric acid as an electrolyte where the electrolyte concentration was maintained at 10 vol.% by using a jacketed beaker. For anode, 5083 aluminum alloy with thickness of 5 mm and size of $2cm{\times}2cm$ was used, while platinum electrode was used for cathode. The distance between the two was maintained at 3 cm. Afterward, the irregular oxide film that was created in the first step surface modification was removed. For the second step surface modification process (identical to the step 1), etching was performed using mixture of chromic acid (1.8 wt.%) and phosphoric acid (6 wt.%) at $60^{\circ}C$ temperature for 30 minutes. Anodic polarization test was performed at scan rate of 2 mV/s up to +3.0 V vs open circuit potential in natural seawater. Surface morphology was compared using 3D analysis microscope to observe the damage behavior. As a result, the case of surface modification presented a significantly lower corrosion current density than that without modification, indicating excellent corrosion resistance.

  • PDF

The Protection Potential Decision by Electrochemical Experiment of Al-Mg-Si Alloy for Ship in Seawater (해수용액에서 선박용 Al-Mg-Si 합금의 전기화학적 실험에 의한 방식전위 결정)

  • Jeong, S.O.;Park, J.C.;Han, M.S.;Kim, S.J.
    • Corrosion Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.48-55
    • /
    • 2010
  • The many vessels are built with FRP(Fiber-Reinforced Plastic) material for small boats and medium vessels. However, FRP is impossible to be used for recyclable material owing to environmental problems and causes large proportion of collision accidents because radar reflection wave is so weak that large vessels could not detect FRP ships during the sailing. Hence, Al alloy comes into the spotlight to solve these kinds of problems as a new-material for next generation instead of FRP. Al alloy ships are getting widely introduced for fish and leisure boats to save fuel consumption due to lightweight. In this study, it was selected 6061-T6 Al alloy which are mainly used for Al-ships and carried out various electrochemical experiment such as potential, anodic/cathodic polarization, Tafel analysis, potentiostatic experiment and surface morphologies observation after potentiostatic experiment for 1200 sec by using the SEM equipment to evaluate optimum corrosion protection potential in sea water. It is concluded that the optimum corrosion protection potential range is -1.4 V ~ -0.7 V(Ag/AgCl) for 6061-T6 Al alloy, in the case of application of ICCP(Impressed current cathodic protection), which was shown the lowest current density at the electrochemical experiment and good specimen surface morphologies after potentiostatic experiment for Al-Mg-Si(6061-T6) Al alloy in seawater environment.

Channel Model and Wireless Link Performance Analysis for Short-Range Wireless Communication Applications in the Terahertz Frequency (테라헤르츠 대역 주파수에서 근거리 무선 통신 응용을 위한 채널 모델 및 무선 링크 성능 분석)

  • Chung, Tae-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.868-882
    • /
    • 2009
  • In this paper, channel model and wireless link performance analysis for the short-range wireless communication system applications in the terahertz frequency which is currently interested in many countries will be described. In order to realize high data rates above 10 Gbps, the more wide bandwidths will be required than the currently available bandwidths of millimeter-wave frequencies, therefore, the carrier frequencies will be pushed to THz range to obtain larger bandwidths. From the THz atmospheric propagation characteristics based on ITU-R P.676-7, the available bandwidths were calculated to be 68, 48 and 45 GHz at the center frequencies of 220, 300 and 350 GHz, respectively. With these larger bandwidths, it was shown from the simulation that higher data rate above 10 Gbps can be achieved using lower order modulation schemes which have spectral efficiency of below 1. The indoor propagation delay spread characteristics were analyzed using a simplified PDP model with respect to building materials. The RMS delay spread was calculated to be 9.23 ns in a room size of $6\;m(L){\times}5\;m(W){\times}2.5\;m(H)$ for the concrete plaster with TE polarization, which is a similar result of below 10 ns from the Ray-Tracing simulation in the reference paper. The indoor wireless link performance analysis results showed that receiver sensitivity was $-56{\sim}-46\;dBm$ over bandwidth of $5{\sim}50\;GHz$ and antenna gain was calculated to be $26.6{\sim}31.6\;dBi$ at link distance of 10m under the BPSK modulation scheme. The maximum achievable data rates were estimated to be 30, 16 and 12 Gbps at the carrier frequencies of 220, 300 and 350 GHz, respectively, under the A WGN and LOS conditions, where it was assumed that the output power of the transmitter is -15 dBm and link distance of 1 m with BER of $10^{-12}$. If the output power of transmitter is increased, the more higher data rate can be achieved than the above results.

Effect of the Amount of CH4 Content on the Characteristics of Surface Layers of Low Temperature Plasma Nitrocarburizied STS 204Cu Stainless Steel (STS 204Cu 스테인리스강의 저온 플라즈마 침질탄화 처리 시 CH4 가스 함량에 따른 경화층 (S-Phase) 거동)

  • Lee, Insup;Kim, Hojun
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.1
    • /
    • pp.54-61
    • /
    • 2018
  • Plasma Nitriding treatment was performed on STS 204Cu stainless steel samples at a temperature of $400^{\circ}C$ for 15 hours with varying $N_2$ content as 10%, 15% and 25%. Regardless of the content of $N_2$, S-Phase which is a hardened layer of Nitrogen (N) supersaturated phase, was formed in the surface of plasma treated samples. When $N_2$ content was 25%, the thickness of the hardened layer reached up to about $7{\mu}m$ and the surface hardness reached a value of $560Hv_{0.05}$, which is about 2.5 times higher than that of untreated sample (as received $220Hv_{0.05}$). From potentiodynamic polarization test, it was observed that compared to as received sample, the corrosion potential and the corrosion current density of the plasma treated samples were decreased regardless of the $N_2$ content, but the corrosion resistance was not increased much due to the precipitation of $Cr_2N$. On the other hand, pitting potential of the samples treated with 10% and 15% $N_2$ was higher than that of as received sample, however, the samples treated with 25% exhibited a lower pitting potential. Therefore, 10% $N_2$ content was selected as optimum plasma nitriding condition and to further increase both the thickness and surface hardness and the corrosion resistance of the hardened layer, different $CH_4$ content such as 1%, 3% and 5% was introduced into the plasma nitriding atmosphere. With 1% $CH_4$, the thickness of the hardened layer reached up to about $11{\mu}m$ and the surface hardness was measured as about $620Hv_{0.05}$, which is about 2.8 times that of as received sample. And the corrosion resistance of the plasma treated sample by using 1% $CH_4$ was improved significantly due to much higher pitting potential, and lower corrosion current density. When the $CH_4$ content was more than 1%, the thickness and surface hardness of the hardened layer decreased slightly and the corrosion resistance also decreased.

Polarization of Stimulated Emission from Optically Pumped AIGaN/GaInN DH (AIGaN/GaInN DH의 광여기 유도방출광의 편광)

  • ;;H. Amano;I. Akasaki
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 1994.11a
    • /
    • pp.98-98
    • /
    • 1994
  • 최근 청색반도체레이저의 실현을 위하여 ZnSe가 대표하는 II-Ⅵ족 화합물반도체와 Gan가 대표하는 III족 질화물반도체분야에서 집중적인 연구가 이루어지고 있으며, 아직까지 실용화 되지 않고 있는 청색반도체레이저의 출현에 대하여 많은관심이 모아지고 있다. III족 질화물반도체는 InM(Eg:1.9eV)부터 AIN(Eg: 6.2eV)에 이르기까지 전 조성영역에서 완전한 고용체를 이루며, 실온에서 직접천이형 에너지 대구조를 가지므로 청색 혹은 자외영역에서 동작하는 발광소자를 제작하는데 있어 유망시 되고 있는 소재이다. 특히 GaN와 InN의 3원흔정인 GaInN를 활성층으로 이용하면 그 발전파장을 370nm부터 650nm까지 즉 가시 전 영역으로부터 근 자외영역을 포함할 수 있게 된다. 이 연구에서는 AIGaN/GaInN 이중이종접합(DH) 구조의 고아여기에 의한 유도방출고아의 편광 특성을 조사하였다. 유기금속기상에피텍셜(MOVPE)법으로 성장한 AIGaN/GaInN DH 구조의 표면에 수직으로 펄스 발진 질소레이저(파장: 337.1cm, 주기 10Hz, 폭: 8nsec) 빔을 조사하고 DH구조의 단면으로부터의 유도방출광을 편광기를 통과 시킨 후 스펙트럼을 측정하였다. 입사고아 밀도가 증가함에 따라 약 402nm의 파장에서 유도발출에 의한 가도가 큰 피크가 나타났고, 그 반치폭은 약 18meV이었다. 실온에서 AIGaN/GaInN DH 구조로 부터의 유도방출에 필요한 입사광밀도의 임계치는 약 130㎾/$\textrm{cm}^2$이었다. 한편 편광각이 90$^{\circ}$일때는 발광스펙트럼의 강도가 매우 낮고 단지 자연방출에 의한 스펙트럼만이 나타났다. 편광각이 0$^{\circ}$일 때 최대의 방출광 강도를 나타내었으며, 편광각이 -90$^{\circ}$로 회전함에 따라 발고아강도의 강도가 감소하였다. 이와 같은 결과는 광여기에 의하여 AIGaN/GaInN DH 로 부터의 유도방출광이 GaInN활성층의 단면에 평행한 전기장의방향으로, 즉 TE모드로 선형적으로 편광됨을 의미한다. AIGaN/GanN DH 로 부터의 유도방출이 선형적으로 TE모드로 편광되는 것은 이 구조를 이용한 청색 및 자외선 반도체 레이저다이오드의 실현에 매우 유익한 것이다.

  • PDF

Simulation of Neutron irradiation Corrosion of Zr-4 Alloy Inside Water Pressure reactors by Ion Bombardment

  • Bai, X.D.;Wang, S.G.;Xu, J.;Chen, H.M.;Fan, Y.D.
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.96-109
    • /
    • 1997
  • In order to simulate the corrosion behavior of Zr-4 alloy in pressurized water reactors it was implanted (or bombarded) with 190ke V $Zr^+\; and \;Ar^+$ ions at liquid nitrogen temperature and room temperature respectively up to a dose of $5times10^{15} \sim 8\times10^{16} \textrm{ions/cm}^2$ The oxidation behavior and electrochemical vehavior were studied on implanted and unimplanted samples. The oxidation kinetics of the experimental samples were measured in pure oxygen at 923K and 133.3Pa. The corrosion parameters were measured by anodic polarization methods using a princeton Applied Research Model 350 corrosion measurement system. Auger Electron Spectroscopy (AES) and X-ray Photoelectric Spectroscopy (XPS) were employed to investigate the distribution and the ion valence of oxygen and zirconium ions inside the oxide films before and after implantation. it was found tat: 1) the $Zr^+$ ion implantation (or bombardment) enhanced the oxidation of Zircaloy-4 and resulted in that the oxidation weight gain of the samples at a dose of $8times10^{16}\textrm{ions/cm}^2$ was 4 times greater than that of the unimplantation ones;2) the valence of zirconium ion in the oxide films was classified as $Zr^0,Zr^+,Zr^{2+},Zr^{3+}\; and \;Zr^{4+}$ and the higher vlence of zirconium ion increased after the bombardment ; 3) the anodic passivation current density is about 2 ~ 3 times that of the unimplanted samples; 4) the implantation damage function of the effect of ion implantation on corrosion resistance of Zr-4 alloy was established.

  • PDF