• Title/Summary/Keyword: M1 polarization

Search Result 645, Processing Time 0.022 seconds

Coolant Leak Effect on Polymer Electrolyte Membrane Fuel Cell (고분자전해질연료전지의 냉각수 누설에 대한 연구)

  • Song, Hyun-Do;Kang, Jung-Tak;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.301-305
    • /
    • 2007
  • The performance of polymer electrolyte membrane fuel cell could be decreased due to coolant leaked from connection part. Micro pump was used to put small amount of coolant and investigate the effect on fuel cell. The stoichiometric ratio of hydrogen/air was 1.5/2.0, both side of gas was fully humidified, and current density of $400mA/cm^2$ was used as standard condition in this experiment. Constant current method was used to check performance recovery from coolant effect in 3 cell stack. The performance was recovered when coolant was injected in cathode side. On the other hand, the performance was not recovered when coolant was injected in anode side. Ethylene glycol could be converted to CO in oxidation process and cause poisoning effect on platinum catalyst or be adhered on GDL and cause gas diffusion block effect resulting performance decrease. Water with nitrogen gas was supplied in anode side to check performance recovery. Polarization curve, cyclic voltammetry, electrochemical impedance spectroscopy was used to check performance, and gas chromatography was used to check coolant concentration. Constant current method was not enough in full recovery of performance. However, water injection method was proved good method in full recovery of performance.

Cathodic Polarization Measurements on La0.9Sr0.1MnO3 Electrode for Solid Oxide Fuel Cells

  • Lee, H.Y.;Oh, S.M.
    • Applied Chemistry for Engineering
    • /
    • v.4 no.1
    • /
    • pp.153-161
    • /
    • 1993
  • Cathodic oxygen reduction kinetics on $La_{0.9}Sr_{0.1}MnO_3$ electrode have been examined at $700-900^{\circ}C$ under various oxygen partial pressures. AC impedance and current interruption techniques were employed for the determination of charge transfer resistances for electrochemical oxygen reduction. The $R_{ct}$ values obtained from two different methods were very close each other for $La_{0.9}Sr_{0.1}MnO_3$ electrode. Activation energy for the electrochemical oxygen reduction was found to be 174kJ/mol under atmospheric oxygen pressure. $R_{ct}$ measurements as a function of oxygen partial pressure indicate that the rate-determining step for the electrochemical oxygen reduction on $La_{0.9}Sr_{0.1}MnO_3$ electrode is the charge transfer process.

  • PDF

A Study on Chloride Threshold Level of Blended Cement Mortar Using Polarization Resistance Method (분극저항 측정기법을 이용한 혼합 시멘트 모르타르의 임계 염화물 농도에 대한 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu;Ann, Ki-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.245-253
    • /
    • 2009
  • The importance of chloride ions in the corrosion of steel in concrete has led to the concept for chloride threshold level (CTL). The CTL can be defined as the content of chlorides at the steel depth that is necessary to sustain local passive film breakdown and hence initiate the corrosion process. Despite the importance of the CTL, due to the uncertainty determining the actual limits in various environments for chloride-induced corrosion, conservative values such as 0.4% by weight of cement or 1.2 kg in 1 $m^3$ concrete have been used in predicting the corrosion-free service life of reinforced concrete structures. The paper studies the CTL for blended cement concrete by comparing the resistance of cementitious binder to the onset of chloride-induced corrosion of steel. Mortar specimens were cast with centrally located steel rebar of 10 mm in diameter using cementitious mortars with ordinary Portland cement (OPC) and mixed mortars replaced with 30% pulverized fuel ash (PFA), 60% ground granulated blast furnace slag (GGBS) and 10% silica fume (SF), respectively, at 0.4 of a free W/B ratio. Chlorides were admixed in mixing water ranging 0.0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0% by weight of binder(Based on $C1^-$). Specimens were curd 28 days at the room temperature, wrapped in polyethylene film to avoid leaching out of chloride and hydroxyl ions. Then the corrosion rate was measured using the polarization resistance method and the order of CTL for binder was determined. Thus, CTL of OPC, 60%GGBS, 30%PFA and 10%SF were determined by 1.6%, 0.45%, 0.8% and 2.15%, respectively.

Effects of Deposition Pressure on the Phase Formation and Electrical Properties of BiFeO3 Films Deposited by Sputtering

  • Park, Sang-Shik
    • Korean Journal of Materials Research
    • /
    • v.19 no.11
    • /
    • pp.601-606
    • /
    • 2009
  • $BiFeO_3$ (BFO) thin films were prepared on $Pt/TiO_2/Si$ substrate by r.f. magnetron sputtering. The effects of deposition pressure on electrical properties were investigated using measurement of dielectric properties, leakage current and polarization. When BFO targets were prepared, Fe atoms were substituted with Mn 0.05% to increase electrical resistivity of films. (Fe+Mn)/Bi ratio of BFO thin films increases with increasing partial pressure of $O_2$ gas. The deposited films showed the only BFO phase at 10 mTorr, the coexistence of BFO and $Bi_2O_3$ phase at 30-50 mTorr, and the only $Bi_2O_3$ phase at 70 mTorr. The crystallinity of BFO films was reduced due to the higher Bi contents and the decrease of surface mobility of atoms at high temperature. The porosity and surface roughness of films increased with the increase of the deposition pressure. The films deposited at high pressure showed low dielectric constant and high leakage current. The dielectric constant of films deposited at various deposition pressures was 84${\sim}$153 at 1 kHz. The leakage current density of the films deposited at 10${\sim}$70 mTorr was about $7{\times}10.6{\sim}1.5{\times}10.2A/cm^2$ at 100 kV/cm. The leakage current was found to be closely related to the morphology and composition of the BFO films. BFO films showed poor P-E hysteresis loops due to high leakage current.

Lithium ion Transport Characteristics of Gel-Type Polymer Electrolytes Containing Lithium p-[Methoxyoligo(ethyleneoxy)] benzenesulfonates (리튬 p-[메톡시 올리고(에틸렌옥시)]벤젠설폰산염으로 제조된 젤형 고분자 전해질의 리튬 이온 운반 특성)

  • 허윤정;강영구;한규승;이창진
    • Polymer(Korea)
    • /
    • v.27 no.4
    • /
    • pp.385-391
    • /
    • 2003
  • Lithium p-[Methoxyoligo(ethyleneoxy)] benzenesulfonates (LiEOnBS) with different repeating unit of ethylene oxide were synthesized and were used for preparing gel-polymer electrolytes. The conductivities and lithium ion transference number were measured as a function of Li-salt concentration and repeating unit of ethylene oxide of the LiEOnBS. The maximum conductivity of the resulting gel-polymer electrolyte was found to be 4.89${\times}$10$\^$-4/ S/cm (LiEO7.3BS, 0.5 M) at 30$^{\circ}C$. The lithium ion transference number (t$\sub$Li$\sub$+//) measurement were performed by means of the combination do polarization and ac impedance methods in gel-polymer electrolytes. Lithium ion transference number was measured to be in the range of 0.75∼0.92 for the LiEOnBS containing gel-polymer electrolytes. The maximum t$\sub$Li$\sub$+// was obtained to be 0.92 for the 0.1 M LiEOnBS containing polymer electrolytes. The synthesized LiEOnBS showed single ion transport like characteristics when n was large than 3.

Design and implementation of photopolymer-based holographic volume grating couplers for optical interconnection (광연결을 위한 포토폴리머형 홀로그래픽 부피격자 커플러의 설계 및 구현)

  • Lee, Kwon-Yeon;Jeung, Sang-Huek;Cho, Byung-Mo;Son, Myung-Sik;Jeon, Seok-Hee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.261-271
    • /
    • 2008
  • Holographic volume grating couplers (VGCs) are become increasingly attractive device for the application of optical interconnects because of their higher preferential coupling, dry fabrication processing, compact, and low cost. In this paper, the analysis, design, and implementation of the waveguide-imbedded input-output VGC with $45^{\circ}$ grating slant angle using holographic photopolymer(Dupont HRF600-20) for guided-wave optical interconnection applications, are presented. To show the usefulness of the proposed VGC, we fabricated the VGCs operating at 632.8nm and 1550nm wavelengths and its results are presented. The measured input coupling efficiency of the single VGC with $0.5{\mu}m$ grating period at 632.8nm wavelength is above 86.6% for TE-polarization. The input coupling efficiency of the $1\times2$ VGC with $0.73068{\mu}m$ grating period at 1550nm wavelength is about 90.8%.

  • PDF

The Study on the Mechanical Characteristics of Hydrogen Embrittlement for the Weld Zone of Ferrite Stainless Steel (페라이트 스테인리스강 용접부에 대한 수소취성의 기계적 특성에 관한 연구)

  • Choi, Byung-Il;Lim, Uh-Joh
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.4 s.29
    • /
    • pp.11-16
    • /
    • 2005
  • In this paper, the hydrogen osmosis test and the mechanical tensile test were carried out to examine hydrogen cracking behavior of STS444 with welding conditions. In $0.5MH_2SO_4+0.001M \;As_2O_3$ solution, the hydrogen embrittlement characteristics of weld zone of STS444 added to load of $1,400 kg/cm^2$ together with hydrogen osmosis by current of $30mA/cm^2$ for 60 min. was considered. As a result of study on the hydrogen embrittlement and mechanical characteristics of STS444외와 with welding conditions the tensile stress and elongation of STS444 get lower by the absorption of oil or water before welding. Also, the reduction rate of tensile stress and elongation of STS444 is larger because of hydrogen embrittlement by the absorption of oil or water. STS444 by the absorption of water before welding is more sensitive to hydrogen embrittlement than oil.

  • PDF

Evaluation of Reverse Electrodialysis System with Various Compositions of Natural Resources (다양한 농도 공급원의 조합을 통한 역전기투석 장치의 성능 평가)

  • Kwon, Kilsung;Park, Byung Ho;Kim, Dukhan;Kim, Daejoong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.6
    • /
    • pp.513-518
    • /
    • 2015
  • Salinity gradient power (SGP) has attracted significant attention because of its high potential. In this study, we evaluate reverse electrodialysis (RED) with various compositions of available resources. The polarization curve (I-V characteristics) shows linear behavior, and therefore the power density curve has a parabolic shape. We measure the power density with varying compartment thicknesses and inlet flow rates. The gross power density increases with decreasing compartment thickness and increasing flow rate. The net power density, which is the gross power density minus the pumping power, has a maximum value at a compartment thickness of 0.2 mm and an inlet flow rate of 22.5 mL/min. The power density in RED is also evaluated with compositions of desalination brines, seawater, river water, wastewater, and brackish water. A maximum power density of $1.75W/m^2$ is obtained when brine discharged from forward osmosis (FO) and river water are used as the concentrated and the diluted solutions, respectively.

The Characteristics of Electric Field Distributions in a Reverberation Chamber using Cylindrical Diffuser (원통형 확산기를 사용한 전자파 잔향실내의 전기장 분포특성)

  • Lee, Yong;Rhee, Joong-Geun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.8
    • /
    • pp.121-127
    • /
    • 2008
  • This paper presents an electric field distribution in a reverberation chamber using cylindrical diffuser. The characteristics of electric field distributions are compared with QRD(Quadratic Residue Diffuser) and cylindrical diffuser for $1{\sim}3$ GHz frequency band. The FDTD(Finite-Difference Time-Domain) method is used to analyze the field characteristics, and the field uniformity. At 2 GHz, the standard deviation and the tolerance of test volume in the reverberation chamber are improved by 0.11 dB, 0.43 dB for the case of cylindrical diffuser. The field strength is increased by 43.2 dBmV/m vs QRD's of 36.6 dBmV/m. Comparing with QRD's, the characteristic of polarization is also improved. These results show that reverberation chamber using cylindrical diffuser can be used alternative facility for measurement of electromagnetic interference and immunity.

Preparation of Spherical Li4Ti5O12 and the Effect of Y and Nb Doping on the Electrochemical Properties as Anode Material for Lithium Secondary Batteries (리튬이온이차전지용 구형 Li4Ti5O12 음극 합성 및 Y와 Nb 도핑에 따른 전기화학적 특성)

  • Ji, Mi-Jung;Kwon, Yong-Jin;Kim, Eun-Kyung;Park, Tae-Jin;Jung, Sung-Hun;Choi, Byung-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.6
    • /
    • pp.659-662
    • /
    • 2012
  • Yttrium (Y) and niobium (Nb) doped spherical $Li_4Ti_5O_{12}$ were synthesized to improve the energy density and electrochemical properties of anode material. The synthesized crystal was $Li_4Ti_5O_{12}$, the particle size was less than $1{\mu}m$ and the morphology was spherical and well dispersed. The Y and Nb optimal doping amounts were 1 mol% and 0.5 mol%, respectively. The initial capacity of the dopant discharge and charge capacity were respectively 149mAh/g and 143 mAh/g and were significantly improved compared to the undoped condition at 129 mAh/g. Also, the capacity retention of 0.2 C/5 C was 74% for each was improved to 94% and 89%. It was consequently found that Y and Nb doping into the $Li_4Ti_5O_{12}$ matrix reduces the polarization and resistance of the solid electrolyte interface (SEI) layer during the electrochemical reaction.