• Title/Summary/Keyword: M.I.V

Search Result 2,505, Processing Time 0.028 seconds

STATIC AND RELATED CRITICAL SPACES WITH HARMONIC CURVATURE AND THREE RICCI EIGENVALUES

  • Kim, Jongsu
    • Journal of the Korean Mathematical Society
    • /
    • v.57 no.6
    • /
    • pp.1435-1449
    • /
    • 2020
  • In this article we make a local classification of n-dimensional Riemannian manifolds (M, g) with harmonic curvature and less than four Ricci eigenvalues which admit a smooth non constant solution f to the following equation $$(1)\hspace{20}{\nabla}df=f(r-{\frac{R}{n-1}}g)+x{\cdot} r+y(R)g,$$ where ∇ is the Levi-Civita connection of g, r is the Ricci tensor of g, x is a constant and y(R) a function of the scalar curvature R. Indeed, we showed that, in a neighborhood V of each point in some open dense subset of M, either (i) or (ii) below holds; (i) (V, g, f + x) is a static space and isometric to a domain in the Riemannian product of an Einstein manifold N and a static space (W, gW, f + x), where gW is a warped product metric of an interval and an Einstein manifold. (ii) (V, g) is isometric to a domain in the warped product of an interval and an Einstein manifold. For the proof we use eigenvalue analysis based on the Codazzi tensor properties of the Ricci tensor.

AC loss Measurement of Superconducting Power Cable (초전도 전력케이블의 교류손실 측정)

  • Hwang, Si-Dole;Hyun, Ok-Bae;Sohn, Song-Ho;Choi, Hyung-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.524-526
    • /
    • 2005
  • As a research activity of the project of "Verification Test of Superconducting Power Cable", we measured the AC loss of a short length superconducting power cable. The rating and the length of the cable were 22.9kV, 1,250A and 2.2m. The voltage taps for measuring the AC loss were attached to both ends of the conductor of the superconducting cable. Through the voltage taps and a lock-in amplifier we measured the in-phase component of the voltage($V_x$) with the load current(I). The AC loss was measured by multiplying the in-phase component of the voltage($V_x$) by the load current(I). The value of the AC loss of the superconducting power cable was 1.18W/m/phase/kA at 77.3K, 1atm.

  • PDF

Electrical Properties by Organic Thin Films According to Manufacture Condition (제작조건에 따른 유기박막의 전기특성)

  • Song, Jin-Won;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.467-469
    • /
    • 2000
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 20[mN/m]. LB layers of Arac. acid deposited by LB method were deposited onto Y-type silicon wafer as x, y, z-type film. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/arachidic acid/Al, the number of accumulated layers Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V].

  • PDF

Electrical Properties of Organic Thin Films by Deposition Type (유기박막의 누적형태에 따른 전기특성)

  • 송진원;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.287-290
    • /
    • 2000
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 20[mN/m]. LB layers of Arac. acid deposited by LB method were deposited onto y-type silicon wafer as x, y, z-type film. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/arachidic acid/Al, the number of accumulated layers. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V].

  • PDF

Flow Analysis Of Cardio Vascular Assist By Laser Doppler Velocimeter Measure munt (L.D.V 계측에 의한 보조장기의 유동해석)

  • Park, G.M.;Park, S.B.;Kamm, R.D.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.195-198
    • /
    • 1996
  • This paper is studid the flow analysis of cardio vascular assist device. The experimental study is carried out to measure velocity profiles, Shear stress distributions and Velocity Vector for the flowrare of 4l/min, the frequency of 0.5Hz, the stroke volume of 60ml, the inlet and outlet pressure of 100mmHg by the L.D.V and P.I.V system. These results are agreed with the numerical simulations.

  • PDF

DETERMINATIONS OF ITS ABSOLUTE DIMENSIONS AND DISTANCE BY THE ANALYSES OF LIGHT AND RADIAL-VELOCITY CURVES OF THE CONTACT BINARY - I. V417 Aquilae (접촉쌍성의 광도와 시선속도곡선의 분석에 의한 절대 물리량과 거리의 결정 -1. V417 Aquilae)

  • 이재우;김천휘;이충욱;오규동
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.2
    • /
    • pp.73-82
    • /
    • 2004
  • New photometric and spectroscopic solutions of W-type overcontact binary V 417 Aql were obtained by solving the UBV light curves of Samec et al. (1997) and radial-velocity ones of Lu & Rucinski (1999) with the 2003 version of the Wilson-Devinney binary code. In the light curve synthesis the light of a third-body, which Qian (2003) proposed, was considered and obtained about 2.7%, 2.2%, and 0.4% for U, B, and V bandpasses, respectively. The model with third-light is better fitted to eclipse parts than that with no third-light. Absolute dimensions of V417 Aql are determined from our solution as $M_1$= 0.53 $M_{*}$, $M_2$= 1.45 $M_{*}$, $R_1$= 0.84 $R_{*}$, and $R_2$= 1.31 $M_{*}$, and the distance to it is deduced as about 216pc. Our distance is well consistent with that (204pc) derived from Rucinski & Duerbeck's (1997) relation, $M_{v}$ = $M_{v}$(log P, B-V), but is more distant than that (131$\pm$40pc) determined by the Hipparcos trigonometric parallax. The difference may result from the relatively large error of Hipparcos parallax for V 417 Aql.l.

Construction of Recombinant DNA for Purification of the Gag-Pro Transframe Protein of Human T-cell Leukemia Virus Type I (HTLV-I) (Human T-cell Leukemia Virus Type I (HTLV-I) 의 Gag-Pro Transframe 단백질 정제를 위한 재조합 DNA 의 제작)

  • 남석현
    • Korean Journal of Microbiology
    • /
    • v.30 no.6
    • /
    • pp.466-471
    • /
    • 1992
  • To determine the site at which -1 ribosomal frameshifting occurs within the gag-pro overlap of HTL V-I. DNA fragment corresponding to a portion of the gene overlap was cloned into a SP6 vector. The resultant plasmid harbors the hybrid gene consisting of a synthetic gene encoding 5 amino acids derived from chick prelysozyme including the initiator methionine plus 141 nucleotides of gag-pro overlapping region followed by Staphylococcus aurcus protein A gene fragment. In vitro transcription by SP6 RNA polymerase with this DNA template made an abundant amount of single species mRNA. Cell-free translation programmed with the RNA transcribed in vitro yielded a polypeptide of 21 kDal in size. which could be purified into homogeneity by IgG-Sepharose affinity chromatography. In vitro system described in this study must be useful for rapid purification and sequencing of the Gag-Pro transframe protein. allowing to determine the exact frameshift site on mRNA and to identify the tRNA involved in frameshifting event for the expression of pro gene.

  • PDF

Application of Pine Peroxidase to the Amperometric Determination of Hydrogen Peroxidase (과산화수소의 전류법적 정량을 위한 소나무 과산화효소의 활용)

  • Yoon, Kil-Joong
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.3
    • /
    • pp.329-334
    • /
    • 2013
  • A pine needle-embedded graphite enzyme electrode, of which bonding agent is CSM rubber, was newly designed and its electrochemistry was studied based on the amperometry. It involved a ground green leaves of pine tree as a zymogen together with electrochemical mediator, ferrocene within the paste. The plots of ln($i(1-e^{nf{\eta}})$) vs. ${\eta}$ and Lineweaver-Burk at the low potential (-100 to -500 mV) showed good linearities indicating that the amperometric response is by the catalytic power of pine peroxidase. Electrochemical parameters obtained, symmetry factor (${\alpha}$, 0.17), limiting current ($i_1$, 1.99 $A/cm^2$), exchange current density ($i_0$, $5.86{\times}10^{-5}\;A/cm^2$), Michaelis constant ($K_M$, $1.68{\times}10^{-3}$ M) and many others showed that pine peroxidase discharges the role of catalyst quantitatively on the electrode surface. Those proved that the practical use of pine peroxidase is promising in place of the marketed.

Susceptometry Application of Portable HTS SQUID-Based System

  • Timofeev, V.P.;Kim, C.G.;Shnyrkov, V.I.
    • Journal of Magnetics
    • /
    • v.3 no.3
    • /
    • pp.86-88
    • /
    • 1998
  • A portable RF HTS SQUID-based susceptometer was used for small size magnetized sample testing in weak DC (up to 200A/m) and AC (up to 4 A/m) magnetic fields. The system resolution for the magnetic moment is of the order of $1.6{\times}10^{-10} A.m^2$. The measured DC susceptibility of a tested sample agrees well with the value obtained by using a commercial liquid helium susceptometer.

  • PDF

Electrochemical Studies of Lithium Ion Battery Current Collector in the Aprotic Electrolytes: I. Al Current Collector (비수용성 전해질내 리튬이온전지용 집전체의 전기화학적 특성 연구: I. Al 집전체)

  • Park, Heai-Ku
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.620-627
    • /
    • 1999
  • Electrochemical properties of the Al current collector being used in lithium ion batteries have been studied in the 4 different aprotic electrolytes(1 M $LiBF_4$ EC : DMC, 1 M $LiBF_4$ EC : EMC. 1 M $LiPF_6$ EC : DMC. 1 M $LiPF_6$ EC : EMC) employing cyclic voltammetry and impedance measurement. Al electrode showed a wide range of the electrochemical window(0.5~4.1 V vs. $Li/Li^{+}$). However, solid interfacial materials has been formed on the Al surface due to reduction of impurities($H_2O$, $O_2$, etc), lithium salts, and electrolytes at low applied potentials, and aluminum oxides in the highly oxidizing potential as well. Especially, Al current collector was susceptible to localized in consequence of impurities in electrolytes.

  • PDF