• 제목/요약/키워드: M-G set

검색결과 545건 처리시간 0.028초

Multi-scale wireless sensor node for health monitoring of civil infrastructure and mechanical systems

  • Taylor, Stuart G.;Farinholt, Kevin M.;Park, Gyuhae;Todd, Michael D.;Farrar, Charles R.
    • Smart Structures and Systems
    • /
    • 제6권5_6호
    • /
    • pp.661-673
    • /
    • 2010
  • This paper presents recent developments in an extremely compact, wireless impedance sensor node (the WID3, $\underline{W}$ireless $\underline{I}$mpedance $\underline{D}$evice) for use in high-frequency impedance-based structural health monitoring (SHM), sensor diagnostics and validation, and low-frequency (< ~1 kHz) vibration data acquisition. The WID3 is equipped with an impedance chip that can resolve measurements up to 100 kHz, a frequency range ideal for many SHM applications. An integrated set of multiplexers allows the end user to monitor seven piezoelectric sensors from a single sensor node. The WID3 combines on-board processing using a microcontroller, data storage using flash memory, wireless communications capabilities, and a series of internal and external triggering options into a single package to realize a truly comprehensive, self-contained wireless active-sensor node for SHM applications. Furthermore, we recently extended the capability of this device by implementing low-frequency analog-to-digital and digital-to-analog converters so that the same device can measure structural vibration data. The compact sensor node collects relatively low-frequency acceleration measurements to estimate natural frequencies and operational deflection shapes, as well as relatively high-frequency impedance measurements to detect structural damage. Experimental results with application to SHM, sensor diagnostics and low-frequency vibration data acquisition are presented.

Purification, Crystallization, Preliminary X-ray Diffraction and Molecular-Replacement Studies of White-Breasted Water hen (Amaurornis Phoenicurus) Haemoglobin

  • Jagadeesan, G.;Jaimohan, S.M.;Malathy, P.;Aravindhan, S.
    • 통합자연과학논문집
    • /
    • 제6권4호
    • /
    • pp.193-196
    • /
    • 2013
  • Haemoglobin is an interesting physiologically significant protein composed of specific functional prosthetic haem and globin moieties. In recent decades, there has been substantial interest in attempting to understand the structural basis and functional diversity of avian haemoglobins (Hbs). Towards this end, purification, crystallization, preliminary X-ray diffraction and molecular-replacement studies have been carried out on Amaurornis phoenicurus Hb. Crystals were grown by the hanging drop vapor-diffusion method using PEG 2000 and NaCl as precipitants. The crystals belonged to the primitive monoclinic system $P2_1$, with unit-cell parameters $a=65.33{\AA}$, $b=93.14{\AA}$, $c=98.54{\AA}$, ${\beta}=100.48^{\circ}$; a complete data set was collected to a resolution of $2.6{\AA}$. The Matthews coefficient of $2.30{\AA}^3Da^{-1}$ for the crystal indicated the presence of two ${\alpha}_2{\beta}_2$ tetramers in the asymmetric unit.

Beam Characteristics of Polychromatic Diffracted Neutrons Used for Prompt Gamma Activation Analysis

  • S. H. Byun;G. M. Sun;Park, H. D.
    • Nuclear Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.30-41
    • /
    • 2002
  • The neutron beam is fully characterized for the prompt gamma activation analysis facility at Hanaro in the Korea Atomic Energy Research Institute(KAERI). The facility uses thermal neutrons which are diffracted vertically from a horizontal beam port by a set of pyrolytic graphite(PG) crystals positioned at the Bragg angle of 45" Neutron spectra, neutron flux and Cd-ratio are determined for the three extraction modes of diffracted beam by means of the theoretical and experimental efforts. To obtain theoretical result, the reflectivity of pyrolytic graphite is calculated in the diffraction model for mosaic crystal and the angular divergence after diffraction by mosaic crystal is estimated from Monte Carlo simulation. The time-of-flight spectrometer and gold activation wire are used for measuring the neutron spectra. Both the calculated and measured spectra have proven that the unique feature of polychromatic beam obtained by PG crystals are useful for PGAA. The thermal neutron flux of 7.9$\times$107 n/cm$^2$s and the Cd-ratio of 266 for gold have been achieved at the sample position while the reactor operates at 24 MW The uniformity of beam flux is 12% in the central 1$\times$1 cm$^2$ area. Finally, the beam is briefly characterized by the effective velocity and temperature which are determined by measuring the prompt Y-ray spectra for thin and thick boron samples.ples.

리튬 이온전지용 알루미늄 박판의 블랭킹 공정에 관한 연구 (Blanking Process of Aluminum Thin Sheet for Lithium Ion Battery)

  • 김민기;김재홍;신현집;문지희;고대철
    • 소성∙가공
    • /
    • 제30권4호
    • /
    • pp.179-185
    • /
    • 2021
  • Lithium ion batteries are generally manufactured by laser and etching using aluminum thin sheet. These processes are relatively expensive and have low productivity. In this study, blanking process of aluminum thin sheet for lithium ion battery was employed to replace laser cutting and etching process, all to reduce the production cost and improve productivity. Mechanical properties for aluminum and coating were determined by experimental results and rule of mixture for FE analysis of blanking process. Normalized Cockcroft-Latham criteria was also applied to describe shear behavior and critical damage values were determined by comparison of analytical and experimental result. We performed FE analysis to investigate the effects of clearance and punch-die radius on sheared surface of aluminum thin sheet and to determine optimal process condition. We manufactured the die set using the determined optimal process and conducted an experiment to confirm the feasibility of blanking process. The sheared surface of manufactured product was observed by optical microscope. As a results, the proposed process conditions successfully achieved the dimensional requirement in production of lithium ion battery parts.

A Survey of Globular Cluster Systems of Massive Compact Elliptical Galaxies in the Local Universe

  • 강지수;이명균
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.32.2-32.2
    • /
    • 2020
  • Massive Compact Elliptical Galaxies (MCEGs) found in the local universe are as massive as normal galaxies but extremely compact (M∗ > 1011 Msun, Reff < 1.5 kpc). They are considered to be the relics of red nugget galaxies found at high redshift. They are not likely to have undergone many mergers, keeping their original mass and size. Moreover, it is expected that they host a dominant population of red (metal-rich) globular clusters rather than blue (metal-poor) ones. Indeed, Beasley et al. (2018) found that the color distribution of the cluster system of NGC 1277 is unimodal, showing only a red population. However, NGC 1277 is the only case whose cluster system was studied among MCEGs. In this study, we investigate globular cluster systems of 14 nearby MCEGs with a homogeneous data set of HST/WFC3 F814W/F160W archive images. We detect tens to hundreds of globular clusters in each galaxy and examine their color distributions. Surprisingly, the fractions of red globular clusters are similar to those of normal galaxies, and are much lower than that of NGC 1277. We additionally obtain Gemini/GMOS-N g'r'i' images of PGC 70520, one of the 14 nearby MCEGs, to detect more globular clusters from deeper and wider images. We will discuss the results from the Gemini data combined with the results from the HST data in relation with the formation of MCEGs.

  • PDF

Analysis of forced convection in the HTTU experiment using numerical codes

  • M.C. Potgieter;C.G. du Toit
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.959-965
    • /
    • 2024
  • The High Temperature Test Unit (HTTU) was an experimental set-up to conduct separate and integral effects tests of the Pebble Bed Modular Reactor (PBMR) core. The annular core consisted of a randomly packed bed of uniform spheres. Natural convection tests using both nitrogen and helium, and forced convection tests using nitrogen, were conducted. The maximum material temperature achieved during forced convection testing was 1200 ℃. This paper presents the numerical analysis of the flow and temperature distribution for a forced convection test using 3D CFD as well as a 1D systems-CFD computer code. Several modelling approaches are possible, ranging from a fully explicit to a semi-implicit method that relies on correlations of their associated phenomena. For the comparison between codes, the analysis was performed using a porous media approach, where the conduction and radiative heat transfer were lumped together as an effective thermal conductivity and the convective heat transfer was correlated between the solid and gas phases. The results from both codes were validated against the experimental measurements. Favourable results were obtained, in particular by the systems-CFD code with minimal computational and time requirements.

전남 여수지역 곰솔의 현존량 확장계수, 상대생장식 및 임분 현존량 (Biomass Expansion Factors, Allometric Equations and Stand Biomass of Pinus thunbergii in Southern Korea)

  • 박인협;김소담
    • 한국환경생태학회지
    • /
    • 제32권5호
    • /
    • pp.507-512
    • /
    • 2018
  • 곰솔의 줄기밀도, 현존량 확장계수, 상대생장식 및 임분 현존량을 파악하기 위하여 전라남도 여수지역에 위치하고 있는 15년생, 29년생, 45년생 등 3개 곰솔 천연임분을 대상으로 임분별 5주씩 총 15주의 표본목을 선정 벌목하여 조사하였다. 줄기밀도는 $0.440-0.457g/cm^3$이었으며, 임분간 유의적인 차이는 없었다. 지상부와 뿌리를 포함한 임목 전체의 현존량 확장계수는 모두 임령이 증가할수록 감소하였으며, 임분 1은 지상부 현존량 확장계수에서 임분 2, 3과 유의적인 차이가 있었고, 임목 전체 현존량 확장계수에서 임분 3과 유의적인 차이가 있었다. 이것은 임령이 증가할수록 줄기의 건중량 구성비가 높아지기 때문이며, 임분 1의 경우 유령림의 생장특성을 보이기 때문으로 판단되었다. 흉고직경(D) 또는 흉고직경과 수고($D^2H$)를 독립변수로 하고 부위별 건중량(Wt)을 종속변수로 하는 2개 유형의 상대생장식($Wt=aD^b$, $Wt=a(D^2H)^b$)을 유도하고 적합도를 검정하였다. 임분 1, 2, 3의 지상부 현존량은 각각 50.72t/ha, 89.92t/ha, 194.07t/ha이었으며, 뿌리를 포함한 임목 전체 현존량은 각각 61.62t/ha, 113.12t/ha, 248.36t/ha이었다.

Hematological Characteristics of the Cultured Eel, Anguilla japonica by Vibration Stress

  • Kim, Dae-Hee;Nam, Myung-Mo;Lee, Si-Woo;Kang, Kyoung Ho;Kang, Yue Jai;Hur, Jun Wook
    • 한국해양생명과학회지
    • /
    • 제3권2호
    • /
    • pp.81-86
    • /
    • 2018
  • The purpose of this study is to determine the effects of vibration on primary (e.g. plasma cortisol), secondary (e.g. plasma glucose, aspartate aminotransferase (AST), alanine aminotransferase (ALT), Na+, K+ and Cl- and tertiary (e.g. mortality) stress responses in cultured eel, Anguilla japonica. For this purpose, three groups (including one control group and two stress groups) were set up. The control group was made exposed to vibration corresponding to 48 decibel (dB, V) (produced using electric vibrators) for 15 minutes per hour every day, and the two stress groups was made exposed to vibration corresponding to 58 and 68 dB (V) (produced using the same electric vibrators), equally, for 15 minutes per hour every day. Blood was sampled at day 0 (before starting vibration stress tests, BS), and days 1, 3, 5, 7, 9 and 11 (after starting vibration stress tests). As a result, plasma cortisol showed trend to continuously rise by consecutive stress from 4.1±0.1 ng/ml in BS. In 48 dB group (control), cortisol showed the highest level with 7.6±0.9 ng/ml after 7 days (p<0.05), but at 9 and 11 days was not significantly compared with BS level. In 58 dB group, the cortisol showed the highest level with 43.1±4.8 ng/ml after 1st day. Cortisol of 68 dB group increased significantly during the experimental period (14.4±2.3~32.0±5.7 ng/ml) (p<0.05). In 58, and 68 dB groups during the experimental period differed significantly compared to 48 group (p<0.05). Glucose in 48 dB were increased from 42.0 ±5.7 (BS) to 52.5±2.1 (1 day), the level was not significantly from 1 to 11 days. Glucose in 58 and 68 dB groups was increased significantly than BS during experimental period (p<0.05). K+ in 68 dB increased significantly (p<0.05) from 2.3±0.2 mE/ql (BS) to 3.3±0.5 mE/ql at 5 days. In 48 and 58 dB groups during the experimental period differed significantly (p<0.05). Na+ and Cl- levels were not differed significantly during the experimental period. AST and ALT in 58 and 68 dB groups showed trend to continuously rise by consecutive stress. At 7 and 9 days in AST, between 48, 58 and 68 dB groups differed significantly (p<0.05). In 48, 58 and 68 dB groups at 1 day, blood hematocrit increased significantly higher than BS. The 11 days after vibration stress, the mortality in 48, 58 and 68 dB groups was 1.1, 5.1 and 5.8%, respectively. The present results have shown that A. japonica exhibited ''typical'' physiological responses when exposed to chronic vibration stress. These data suggested that chronic vibration stress caused substantial stress in the fish; especially the persisting elevated plasma AST and ALT levels observed would be expected to adverse effect. In conclusion, chronic vibration stress could greatly affects the hematological characteristics in A. japonica.

HPLC-DAD를 이용한 귀비탕 중 6종 생리활성 물질의 동시분석법 확립 (Simultaneous Determination of Six Bioactive Components in Guibi-tang by HPLC-DAD)

  • 양혜진;원진배;마진열;마충제
    • 생약학회지
    • /
    • 제41권4호
    • /
    • pp.313-318
    • /
    • 2010
  • Guibi-tang, a traditional herbal medicine, is used for anti-oxidant, anti-osteoporosis, hemostasis and gastroprotection. To develop an analysis method of simultaneous determination of six compounds, swertisin, decursinol, glycyrrhizin, 6-gingerol, costunolide and decursin in Guibi-tang, a high performance liquid chromatography was used with diode array detector. Six bioactive components were separated on a SHISEIDO $C_{18}$ column ($5\;{\mu}m$, 4.6 mm I.D.${\times}$250 mm) with column temperature $30^{\circ}C$. The gradient elution was composed of water with 0.1% trifluoroacetic acid (TFA) and acetonitrile. UV wavelength was set at 230 nm, 254 nm and 330 nm, respectively. Calibration curve showed good linear regression ($R^2$ > 0.9999). The limits of detection (LOD) and the limits of quantification (LOQ) ranged in 0.03 - 0.23 ${\mu}g/ml$ and 0.08 - $0.70\;{\mu}g/ml$, respectively. The RSD values of intra- and inter-day test were in the range of 0.03 ~ 0.96% and 0.01 ~ 1.46%, respectively. The evaluated results of accuracy test were varied from 92.28% ~ 105.14% with RSD < 1.60%. In conclusion, this developed simultaneous determination method was accuracy and sensitive to the quality evaluation of Guibi-tang.

폐기물소각시설의 유해대기오염물질 배출특성 연구 (Characteristics of Hazardous Air Pollutant Emissions from Waste Incinerators)

  • 박정민;이상보;강준구;김진필;최은선;황원구;권오상
    • 한국대기환경학회지
    • /
    • 제23권2호
    • /
    • pp.183-190
    • /
    • 2007
  • In this study, we have investigated waste incinerators which are one of the major HAPs emission sources. In order to obtain more reliable HAPs emission data from waste incinerators, direct sampling for the possible pollutants from the stack was carried out and the analysis was performed. The purpose of study was to understand the emission status from waste incinerators and recognize the problems and finally to set up a strategy to reduce the HAPs emissions from waste incinerators. The emission concentrations of 8 species of heavy metals and 16 species of PAHs have been analyzed for the first time in Korea. Not only the emission characteristics of HAPs from waste incinerators were identified, but also the analysis of reduction efficiencies for control devices such as BF and wet scrubbing systems was carried out.