• Title/Summary/Keyword: M-적분

Search Result 273, Processing Time 0.038 seconds

A predictor-corrector algorithm of the generalized-$\alpha$ method for analysis of structural dynamics (동적해석을 위한 일반화된$\alpha$ 방범의 예측 수정자 알고리즘)

  • ;Hulbert, Gregory M.
    • Journal of KSNVE
    • /
    • v.5 no.2
    • /
    • pp.207-213
    • /
    • 1995
  • A new predictor-corrector explicit time integration algorithm is presented for solving structural dynamics problems. The basis of the algorithm is the implicit generalized-.alpha. method recently developed by the authors. Like its implicit parent, the explicit generalized-$\alpha$ method is a one- parameter family of algorithms in which the parameter defines the high-frequency numerical dissipation. The algorithm can be utilized effectively for linear and nonlinear structural dynamics calculations is which numerical dissipation is needed to reduce spurious oscillations inherent in non-dissipative time integration methods used to solve wave propagation problems.

  • PDF

Three-dimensinal electro static field calculation of thin film dielectric substance using boundary integral equation method. (경계 적분법을 이용한 박막유전체의 3차원 정전장 해석)

  • Kim, Yong-Il;HwangBo, Hoon;Choi, Hong-Soon;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1123-1125
    • /
    • 2005
  • 본 논문에서는 3차원 공간에 종이와 같은 박막형 유전체가 있을 때 임의의 점에서의 전계$\vec{E}$를 구하기 위해 유전체의 분극벡터$\vec{P}$를 미지수로 하는 경계적분법(Boundary integral method)을 사용한다. 경계적분법의 사용으로 FEM 3차원 해석에 있어서의 요소분할의 난이성 및 계수 행렬의 대형화로 인한 컴퓨터 수행능력의 한계를 극복할 수 있다. 여기서 분극벡터$\vec{P}$를 구하기 위해 전하에서의 전계${ves{E}}_s$에 의한 유전체내의 분극벡터$\vec{P}$를 수식으로 정리하여 $[\vec{K}][\vec{P}]=[\vec{E}]$ 형태의 $\vec{P}$를 미지수로 하는 system matrix를 구성한다. 위의 system matrix 통해 구해진 분극벡터 $\vec{P}$를 이용하여 유전체 밖의 한 점에서의 전계세기 ${\vec{E}}_m$를 구한 후 우리가 구하고자 하는 전계$\vec{E}$를 계산한다.

  • PDF

The intensity of a singular near-tip field around the vertex of a three-dimensional notch or wedge (3 차원 놋치 및 쐐기의 응력 강도계수)

  • Lee, Yong-Woo;Im, Se-Young
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.157-162
    • /
    • 2003
  • Singular stress fields around three-dimensional wedges are examined, and the near-tip intensity is calculated via the two-state M-integral with the aid of the domain integral representation. A numerical example demonstrates the effectiveness and accuracy of the present scheme for computing the stress intensities of singular stresses near the generic three-dimensional wedges.

  • PDF

Performance Analysis of MIMO-OFDM System over Nakagami Fading Channel (나카가미 페이딩 채널하에서 MIMO-OFDM 시스템의 성능분석)

  • Kang, Kyung-Sik;Kim, Won-Sub;Park, Chun-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.8
    • /
    • pp.1797-1804
    • /
    • 2011
  • In this paper, I analyzed array organization of MIMO channel antenna and effect of operation environment by evaluating average BER from linear Space-Time Block Code orthogonal design and suggests designing condition of MT antenna for improved BER and the fading index m. To analyze system performance, I used M-PSK and M-QAM modulation, and to use analysis equations I used integrated by Nakagami fading variable, non-integrated Nakagami fading variable. We can get the organization of channel array by using mathematical calculation on matrix. STBE BER performance will decrease as AOA spreading decrease and such loss can be compensated from extending antenna spacing, and changing array organization.

Correlation Between Left Ventricular Peak Systolic Pressure/End-Systolic Volume Ratio and Symptomatic Improvement with Valve Replacement in Patients with Aortic Regurgitation and Enlarged End-Systolic Volume (대동맥판역류증과 좌심실수축말기용적 확장이 있는 환자에서 좌심실최고수축기압/수축말기용적비와 판막치환후의 증상적 호전과의 관계)

  • Kim, Woong-Han;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.867-874
    • /
    • 1996
  • This study was designed to assess the left ventricular peak systolic pressure/end-systolic volume (PSP/ESV) ratio in predicting symptomatic improvement with valve replacement in patients with aortic regurgitation and enlarged left von'lrlcular volume. We studied 21 patients (15 men and 6 women aged 15 to 60 years) with moderate or severe aortic regur- gitation, no other cardiovascular abnormalities and left ventricular end-systolic volume over 60 m11m2. In this group we assessed the preoperative variables which routinely were measured at cardiac catheterlzation to predict symptomatic improvement with valve replacement. Six months after operation, symptoms were alleviated in 13 patients(62%), and unchanged in 8()8%). By multivariate analysis, the PSP/ESV rati was a strong predictor for functional class 6 months after surgery(p=0.005) and also for change- in functional class prior to an operation to 6 months postoperatively(p=0.0)2). By 6 months after receiving valve replacement, all patients with a ratio over 1. 71 mmHglml/m'were in functional class I or II , in contrast, of those with a ratio < 1.71 mmHg/ml/m2, 40% were in functional class III. The PSP/ESV ratio may help to predict which patients with aortic regurgitation and enlarged left ven- tricular end-systolic volume will have symptomatic improvement with valve replacement.

  • PDF

Evaluation of Shape Parameter Effect on the J-R Curve of Curved CT Specimen Using Limit Load Method (한계하중법을 이용한 Curved CT 시험편의 파괴저항곡선에 미치는 형상변수 영향 평가)

  • Shin, In Hwan;Park, Chi Yong;Seok, Chang Sung;Koo, Jae Mean
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.7
    • /
    • pp.757-764
    • /
    • 2014
  • In this study, the effect of shape parameters on the J-R curves of curved CT specimens was evaluated using the limit load method. Fracture toughness tests considering the shape factors L/W and $R_m/t$ of the specimens were also performed. Thereafter, the J-R curves of the curved CT specimens were compared using the J-integral equation proposed in the ASTM (American Society for Testing and Materials) and limit load solution. The J-R curves of the curved CT specimens were also compared with those of the CWP (curved wide plate), which is regarded to be similar to real pipe and standard specimens. Finally, the effectiveness of the J-R curve of each curved CT specimen was evaluated. The results of this study can be used for assessing the applicability of curved CT specimens in the accurate evaluation of the fracture toughness of real pipes.

High Speed Inductive Link Using Complementary Switching Transmitter and Integrating Receiver (상보적으로 스위칭하는 송신기와 적분형 수신기를 이용한 고속 인덕티브 링크)

  • Kim, Hyun-Ki;Roh, Joon-Wan;Chun, Young-Hyun;Kwon, Kee-Won;Chun, Jung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.12
    • /
    • pp.37-44
    • /
    • 2011
  • This paper presents the method of improving the data rate and BER in the inductive coupling link using a BPM signaling method. A complementary switching transmitter is used to remove invalid glitches at transmitted data, and the concept of pre-distortion is introduced to optimize received data. Also, an integrating receiver is used to increase the sampling margin and equalizing transistors are added in the pre-charge path of the integrator and comparator for high frequency operation. The transceiver designed with a 0.13 um CMOS technology operates at 2.4 Gb/s and consumes 5.99 mW from 1.2 V power supply.

3rd SDM with FDPA Technique to Improve the Input Range (입력 범위를 개선한 FDPA 방식의 3차 시그마-델타 변조기)

  • Kwon, Ik-Jun;Kim, Jae-Bung;Cho, Seong-Ik
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.192-197
    • /
    • 2014
  • In this paper, $3^{rd}$ SDM with FDPA(Feedback Delay Pass Addition) technique to improve the input range is proposed. Conventional architecture with $3^{rd}$ transfer function is just made as adding a digital delay path in $2^{nd}$ SDM architecture. But the input range is very small because feedback path into the first integrator is increased. But, proposed architecture change feedback path into the first integrator to the second integrator, so input range could be improved about 9dB. The $3^{rd}$ SC SDM with only one operational amplifier was implemented using double-sampling technique. Simulation results for the proposed SDM designed in $0.18{\mu}m$ CMOS technology with power supply voltage 1.8V, signal bandwidth 20KHz and audible sampling frequency 2.8224MHz show SNR(Signal to Noise Ratio) of 83.8dB, the power consumption of $700{\mu}W$ and Dynamic Range of 82.8dB.

A Study of Extensional Viscosity of Fluid M1 in Converging Channel Rheometer Using K-BKZ Intergral Constitutive Equation (수렴관 유변측정기에서 K-BKZ 적분형 구성식을 사용한 M1유체의 신장점도에 관한 연구)

  • 김동회
    • The Korean Journal of Rheology
    • /
    • v.6 no.1
    • /
    • pp.30-40
    • /
    • 1994
  • 고분자 물질의 신장점도를 측정하기 위하여 설계된 수렴관을 지나는 시험 유체 M1 에대하여 유한요소방법으로 수치모사를 수행하였다. 구성방정식은 세 개의 이완시간을 가진 적분형 K-BKZ모형을 사용하였다. 신장변형이 지배적이고 변형속도가 매우 큰 흐름에 대하 여 실험적 방법으로 측정이 가능한 범위까지 수치모사를 수행하였다. 두 개의 압력 측정꼬 지 사이의 벽면 압력차에 대하여 압력 신호로 측정한 실험값을 수치모사결과와 비교하였다. 걷보기 전단속도가 매우 큰 1300s-1에 이르는 높은 유속의 전 실험범위에 대하여 안정된 수 치해를 얻을수 있었다. 3$0^{\circ}C$에서는 모든 실험범위의 유속에서 압력차에 대한 수치모사 결과 가 실험값과 잘일치했다. 21$^{\circ}C$에서는 0.1$\times$10-3m3/s보다 낮은 유속범위에서 실험값과 일치하 는 결과를 얻었으나 그보다 높은 유속에서 실험값과 일치하는 결과를 얻었으나 그보다 높은 유속에서 실험값과 다른 경향의 결과를 얻었다. 이것은 낮은 온도 높은 유속 조건에서 M1 유체의 성질이 불안정하고 또한 그러한 조건의 실험에서 발생한 압력 측정꼭지 부근의 기포 들이 정확한 압력측정에 영향을 끼쳤기 때문이다. 수치모사 결과로부터 얻은 압력과 응력분 포로부터 수렴관 유변측정기의 유동특성을 밝힐수 있었다. 이는 실험적 방법을 통해서는 얻 기 어려운 결과들로서 중요한의미를 가진다. 특별한 모양을 갖도록 설계된 수렴관을 통과하 는 M1 유체가 중심부근에서 일정한 신장변형속도로 변형됨을 확인할 수 있었으며 수직응력 은 지수적으로 증가하다가 축소부분을 지난 후 매우 장점도를 얻기 위하여 신장변형속도가 일정한 구역이 두 배로 확장된 수렴관이 수치적으로 다루어졌고 이를 통하여 기존의 수렴관 에서 구한 값보다 큰 신장점도를 얻을 수 있었다.

  • PDF

A Strength Analysis of Welded Plates Using the J-integral (J-적분을 이용한 용접부 강도 해석)

  • 이민호;양영수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.326-329
    • /
    • 2000
  • Study of Weldment fracture behavior mcludes thermal analysis, residual stress analysis, and fracture analysis The 1-integral loses its path-independency in a res~dual stress field Therefore, it id necessary to develop a program to calculate the J-integral in a welded plate. m this study, theoretical formulation and program were developed for the evaluation of the 1-integral at the crack tip o i weldments. To verify equations and program, welded thin plate and thick plate were used to calculate residual stress and the J-integral.

  • PDF