• Title/Summary/Keyword: M&S Technique

Search Result 2,401, Processing Time 0.026 seconds

LOCATING ROOTS OF A CERTAIN CLASS OF POLYNOMIALS

  • Argyros, Ioannis K.;Hilout, Said
    • East Asian mathematical journal
    • /
    • v.26 no.3
    • /
    • pp.351-363
    • /
    • 2010
  • We introduce a special class of real recurrent polynomials $f_m$$($m{\geq}1$) of degree m+1, with positive roots $s_m$, which are decreasing as m increases. The first root $s_1$, as well as the last one denoted by $s_{\infty}$ are expressed in closed form, and enclose all $s_m$ (m > 1). This technique is also used to find weaker than before [6] sufficient convergence conditions for some popular iterative processes converging to solutions of equations.

An Improvement of Distance Relay Technique Reliability using Elman Network (Elman Network를 이용한 거리계전기법의 신뢰성 향상)

  • Jung, H.S.;Lee, J.J.;Shin, M.C.;Lee, B.K.;Park, C.W.;Jang, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.212-214
    • /
    • 2000
  • The distance relay technique used for transmission line protection operates overreach and underreach to the self protection region because the power system becomes complex and fault conditions are different. To solve these problems, this paper describes new technique to set the reliable self protection lesion. The trip region of the quadrilateral distance relay is set by training of multi layer recurrent elman network. The proposed network is able to reach the trip zone for the fault impedance, fault initial angle and source impedance variance correctly.

  • PDF

Ultra-fast Detection and Differentiation of Mycoplasma haemofelis and Candidatus M. Haemominutum in Korean Feral Cats by Microchip Electrophoresis with Programmed Field Strength Gradients

  • Kumar, Kailasa S.;Lee, Hee-Gu;Yoo, Dong-Jin;Kang, Seong-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.153-158
    • /
    • 2008
  • A microchip-based capillary gel electrophoresis (MCGE) technique was developed for the ultra-fast detection and differentiation of Candidatus Mycoplasma haemominutum (Candidatus M. haemominutum, California strain) and Mycoplasma haemofelis (M. haemofelis, Ohio strain) in Korean feral cats through the application of programmed field strength gradients (PFSG) in a conventional glass double-T microchip. The effects of the poly (ethyleneoxide) (PEO) concentration and electric field strength on the separation of DNA fragments were investigated. The PCR-amplified products of Candidatus M. haemominutum (202-bp) and M. haemofelis (273-bp) were analyzed by MCGE within 75 s under a constant applied electric field of 117.6 V/cm and a sieving matrix of 0.3% PEO (Mr 8 000 000). When the PFSG was applied, MCGE analysis generated results 6.8-times faster without any loss of resolution or reproducibility. The MCGE-PFSG technique was also applied to eleven samples selected randomly from 33 positive samples. The samples were detected and differentiated within 11 s. The analysis time of the MCGE-PFSG technique was approximately 980-times faster than that using conventional slab gel electrophoresis.

A Study on Reducing of Entrance Surface Dose with the Eye in the Computed Radiography by Using High Kilo Voltage Peak Technique (컴퓨터 방사선영상에서 고 관전압 기법을 이용한 안구 입사표면선량 감소에 관한 연구)

  • Seoung, Youl-Hun;Rhim, Jea-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study was to minimize of entrance surface dose (ESD) at the eye using high kVp technique in the computed radiography. We used REX-650R (Listem, Korea) general X-ray unit, and external detector with ESD dosimeter of Piranha 657 (RTI Electronics, Sweden). We used head of the whole body phantom. The total 64 images of X-ray anterior-posterior of skull were acquired using the film/screen (F/S) method and the digital of computed radiography method. The three radiology professor of more 10 years of clinical career evaluated a X-rays images in the same space by 5-point scale. The external detector was performed measurement of ESD of three times by same condition on the eye of the head phantom. The good image quality in the F/S method (90 kVp, 2.5 mAs) showed at the minimized ESD of 0.310 ${\pm}$ 0.001 mGy. the good image quality in the computed radiography method (90 kVp, 2.0 mAs) showed at the minimized ESD of 0.180 ${\pm}$ 0.002 mGy (P = 0.002). Finally the radiation dose could reduced about 50% in the computed radiography method more than the F/S method. In addition the eye entrance surface dose using high kVp technique with the computed radiography was reduced 92% more than conventional technique (F/S method).

A Study on the Mitigation of the Exposure Dose Applying Bolus Tracking in Brain Perfusion CT Scan (뇌 관류 CT검사에서 BolusTracking기법을 적용한 피폭선량 저감화에 관한 연구)

  • Kim, Ki-Jeong;Jung, Hong-Ryang;Lim, Cheong-Hwan;Hong, Dong-Hee;Shim, Jae-Goo;You, In-Gyu
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.353-358
    • /
    • 2014
  • This study was conducted to analyze the patient's exposed dose targeting the patients who had acute ischemic stroke symptoms and CT brain perfusion scan, by comparing fixed time technique and bolus tracking technique which was provided by the manufacturer and to identify the Time graph to implement the usability of contrast medium's tracking technique the best contrast enhancement intervals. $CTDI_{VOL}$ of PCT in patient appeared to be 431.72mGy in fixed scan delay protocol, whereas 323.61mGy in Bolus tracking technique. The value of DLP appeared to be $1243.47mGy{\cdot}cm$ in fixed scan delay protocol, whereas $932mGy{\cdot}cm$ in Bolus tracking technique. Time graph appeared to be various in fixed scan delay protocol, whereas the optimal time graph could be obtained in Bolus tracking. The exposure dose could be reduced by 25% applying Bolus tracking technique when taking brain perfusion CT scan.

Blast Modeling of Concrete Column Using PFC (PFC를 이용한 콘크리트기둥의 발파모델링)

  • Choi Byung-Hee;Yang Hyung-Sik;Ryu Chang-Ha
    • Explosives and Blasting
    • /
    • v.23 no.1
    • /
    • pp.47-54
    • /
    • 2005
  • An explosion modeling technique was developed by using the spherical discrete element code, $PFC^{3D}$, which can be used to model the dynamic stress wave propagation phenomenon. The modeling technique is simply based on an idea that the explosion pressure should be applied to a $PFC^{3D}$ particle assembly not in the form of an external force (body force), but in the form of a contact force (surface force). A test blast was conducted for a RC column, whose dimension was $600\times300\times1800$ in millimeters. The initial velocities of the surface movements were measured to be in the range of $14\~18\;m/s$ with the initiation times of $1.5\~2.0m$. Then the blasting procedure was simulated by using the modeling technique. The particle assembly representing the concrete was made of cement mortar and coarse aggregates, whose mirco-properties were obtained from the calibration processes. As a result, the modeling technique developed in this study made it possible for the burden to move with the velocity of $17\~24\;m/s$, which are slightly higher values compared to those of the test blast.

A Surface Generation Velocity Measurement Technique Using the Buried Channel MOS Structure (Buried Channel MOS 구조를 이용한 표면생성속도 측정 방법)

  • 조성호;허연철;이종덕
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.7
    • /
    • pp.56-63
    • /
    • 1992
  • A measurement technique of the surface generation velocity S$_o$ using the BC(buried channel) MOS structure with shallow and low doped channel layer (BC MOS S$_o$ measurement technique) is presented and verified analytically and experimentally. Using this measurement technique, S$_o$ can be measured more accurately than that measured using the gate-controlled diode SS1oT measurement technique. When S$_o$ is measured for the two techniques from a BC MOS structure test patten with gate length of 171$\mu$m, the results are 0,66cm/sec and 0.28cm/sec for the former and the latter respectively.

  • PDF

Optimization of Laser Photolithography Micromachining Technique based on Taguchi Method (다구찌 방법을 이용한 레이저 포토리소그라피 미세패턴가공 기술의 최적화)

  • Baek, Nam-Kook;Kim, Dae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.871-875
    • /
    • 2001
  • Laser photolithography technique is useful for fabricating micro-patterns of silicon wafers. In this work, the laser photolithography micromachining technique is optimized based on Taguchi method. Sensitivity analysis was performed using laser scanning speed and laser power level as the parameters. The results show that for the photoresist used in this work, a laser scan speed of $70{\mu}m/s$ at 50mW laser power gives the best result.

  • PDF