• 제목/요약/키워드: M&S Technique

검색결과 2,406건 처리시간 0.032초

The ensemble averaged bispectrum을 이용한 유발전위 검출 알고리즘 (Algorithm detecting an evoked potential using the ensemble averaged bispectrum)

  • 최정미;배병훈;김수용
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.124-127
    • /
    • 1994
  • A technique based on bispectrun averaging is described for generally recovering the signal waveform from a set of noisy signals with variable signal delay. The technique does not require explicit tune alignment of signals and any initial estimate of signal. The new method is suggested and is compared with other methods. This method are numerically investigated using computer generated-data and a physiological signal and noise Some experimental results for the evoked potential studios that demonstrate the technique are given. The results show the effectiveness of the technique: various potential applications of the technique might be expected.

  • PDF

자기연마기술을 이용한 고속절삭공구 성능향상에 관한 연구 (A Study on the Improvement of Performance of High Speed Cutting Tool using Magnetic Fluid Grinding Technique)

  • 박성률;조종래;박명균;양순철;정윤교
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1289-1293
    • /
    • 2005
  • We will improve tools performance without the change of a tools' physical shape, if we process mirror like finishing on the surface of cutting tools. Because cutting tools' shapes are very complex, the general method of polishing can't be polished. So we will apply new method of polishing which is magnetic fluid grinding technique. Magnetic fluid grinding technique can polish complex shape's workpiece by pressing the surface of workpiece with magnetic and abrasive grains in magnetic field. Therefore we developed the polishing equipment to improve the performance of cutting tools and experimented on various polishing conditions to determine the polishing conditions of cutting tools.

  • PDF

Sex Determination of In Vitro Fertilized Bovine Embryos by Fluorescence In Situ Hybridization Technique

  • Han, M.S.;Cho, E.J.;Ha, H.B.;Park, H.S.;Sohn, S.H.
    • Reproductive and Developmental Biology
    • /
    • 제28권2호
    • /
    • pp.133-137
    • /
    • 2004
  • Sexing from bovine embryos which were fertilized in vitro implicate a possibility of the sex-controlled cattle production. This study was carried out to investigate the possibility of determining of embryo sex by fluorescence in situ hybridization (FISH) technique. FISH was achieved in in vitro fertilized bovine embryos using a bovine Y-specific DNA probe which constructed from the btDYZ-1 sequences. To evaluate Y-chromosome specificity of the FISH probe, metaphase spreads of whole embryos and lymphocytes were prepared and tested. A male-specific signal was detected on 100% of Y chromosome bearing metaphase specimens. Using the FISH technique with a bovine Y-specific probe, 232 whole embryos of 8 cell- to blastocyst-stage were analyzed. Observing the presence of the Y-probe signal on blastomeres, 102 embryos were predicted as male, and 130 embryos as female. The determining rate of embryo sex by FISH technique was about 93% regardless of embryonic stages. In conclusion, the FISH using a bovine Y-specific DNA probe is an accurate, reliable and quick method for determining the sex of bovine embryos.

고분해능 이색 PIV를 이용한 가솔린 엔진 연소실내 난류의 공간적 해석 (Spatial Analysis of Turbulent Flow in Combustion Chamber using High Resolution Dual Color PIV)

  • 이기형;이창식;이현직;전문수;주영철
    • 한국자동차공학회논문집
    • /
    • 제6권6호
    • /
    • pp.132-141
    • /
    • 1998
  • Particle image velocimetry(PIV), a planar measuring technique, is an efficient tool for studying the complicated flow field such as in-cylinder flow, and intake port flow. PIV can be also used for analyzing the integral length scale of turbulence, which is a measure of the size of the large eddies that contain most of the turbulence kinetic energy. In this study, dual color scanning PIV was designed and demonstrated by using a rotating mirror and a beam splitter. This PIV system allowed enlargement of flexibility in the intensity of vectors to be calculated by spatial filtering technique, even in combustion chamber with high velocity gradient and high vorticity$({\sim}1000s^{-1})$. A new color image processing algorithm was developed, which was used to find the direction of particle movement directly from the digital image. These measuring techniques were successfully applied to obtaining the turbulence intensity (~0.1m/s) and the turbulent integral length scale of vorticity(~1mm).

  • PDF

합성 진상전류 개폐 시험설비의 회로설계에 관한 연구 (A study on circuit design of synthetictest facilities of capacitive current switching tests)

  • 김맹현;서윤택;윤학동;신영준;강영식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.38-40
    • /
    • 2002
  • A study on the test method and the test facilities of synthetic capacitive current tests have been very slight and the direct test method with the short-circuit generator and power transformer only used up to now. However, according to the development of analysis technique of power system and design and manufacture technique we are realized that direct testing method is not satisfactory to evaluate the performance of circuit-breaker because it is difficult to simulate precisely the conditions of power system. Therefore, in order to solve these problem this paper deals with the tests methods and the design technique of the tests facilities of the synthetic capacitive current based on the same theory with the synthetic short-circuit tests.

  • PDF

무가압침투법에 의한 $SiC_p/Al$ 복합재료의 제조 및 기계적 특성 (Fabrication and Mechanical Properties of $SiC_p/Al$ Composites by Pressureless Infiltration Technique)

  • 진훈구;오명석;김영식
    • 동력기계공학회지
    • /
    • 제5권4호
    • /
    • pp.74-81
    • /
    • 2001
  • The infiltration behavior of molten Al-alloy, microstructures, hardness, and the interfacial reactions of $SiC_p/Al$ composites fabricated by the pressureless infiltration technique were investigated. It was made clear that both the weight fraction of SiC reinforcement and additive Mg content considerably influenced on the infiltration behavior of the molten Al-alloy matrix. Complete infiltration of molten Al-alloy achieved under the conditions that weight fraction of SiC content is more than 30wt%, and additive Mg content is more than 9wt%. Interfacial region of Al-alloy matrix and SiC reinforcement phase, $Mg_2Si$ was formed by the reaction between Mg and SiC. Another reaction product AlN was also formed by the reaction between Al-alloy matrix and gas atmosphere nitrogen.

  • PDF

양방향 풀-브릿지 DC-DC 컨버터를 위한 새로운 소프트 스위칭 기법 (A New Soft Switching Technique for Bi-directional Power Flow, Full-bridge DC-DC Converter)

  • 송유진;박석인;정학근;한수빈;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.251-255
    • /
    • 2005
  • This paper proposes a new soft switching technique for a phase-shift controlled bi-directional DC-DC converter. The described converter employs a low profile high frequency transformer and two active full-bridge converters for bidirectional power flow capability. A new soft switching technique is proposed, which guarantees soft switching over wide range (no load to full load) without any additional circuit components. In the proposed switching scheme, the switch pairs in the diagonal position of the converter each are turned on/off simultaneously by the switching signals with a variable duty ratio depending on the phase shift amount, and the converter is operated without freewheeling interval.

  • PDF

An Iterative Technique for Real-Time Tracking of Power System Harmonics

  • Sidhu, T.S.;Zadeh, M.R.D.;Pooranalingam, P.J.;Oh, Yong-Taek
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.319-327
    • /
    • 2011
  • An iterative technique based on orthogonal filters and frequency tracking is proposed to estimate harmonic components in power systems. The technique uses frequency interpolation to estimate fundamental frequency and harmonics when the nominal frequency of the signal is a non-integer value. Due to the number of computations involved during the generation of filter coefficients, an offline computation is suggested. Beneficial features of the proposed technique include fixed sampling rate and fixed data window size. The performance of the proposed technique is examined by simulating different power system operating conditions and evaluating the data from these simulations. A technique based on Fast Fourier Transform is also used to estimate the harmonic components for all the simulated signals. These estimates are compared with those obtained from the proposed technique. Results show that the proposed technique can converge to the accurate fundamental frequency and therefore, provide accurate harmonic components even when the fundamental frequency is not equal to the nominal frequency.

Capillary Size-exclusion Chromatography as a Gel-free Strategy in Plasma Proteomics

  • Cho, Man-Ho;Wishnok, John S.;Tannenbaum, Steven R.
    • Molecular & Cellular Toxicology
    • /
    • 제1권2호
    • /
    • pp.87-91
    • /
    • 2005
  • Although 2D-PAGE has been widely used as the primary method for protein separation, difficulties in displaying proteins with an extreme values of isoelectric paint (pI), molecular size and hydrophobicity limit the technique. In addition, time consuming steps involving protein transfer and extraction from the gel-pieces can result in sample loss. Here, we describe a novel protein separation technique with capillary size-exclusion chromatography (CSEC) for rapid protein identification from human plasma. The method includes protein fractionation along with molecular size followed by in-solution tryptic digestion and peptide analysis through reversed phase liquid chromatography (RPLC) coupled to nanoflow electrospray-tandem mass spectrometry (ESI-MS/MS). Tryptic peptides are applied an a $100\;{\mu}m\;i.d.{\times}10mm$ length pre-column and then separated on a $75\;{\mu}m{\times}200mm$ analytical column at -100 nL/min flaw rate. Proteins were identified over the wide ranges of pI (3.7-12.3) when this technique was applied to the analysis of $1-2\;{\mu}L$ of human plasma. This gel-free system provides fast fractionation and may be considered a complementary technique to SDS-PAGE in proteomics.

최소침습 방사능 유도 부갑상선 수술 (Minimally Invasive Radio-guided Parathyroid Surgery)

  • 정웅윤;장항석;이종두;박정수
    • 대한두경부종양학회지
    • /
    • 제15권2호
    • /
    • pp.194-199
    • /
    • 1999
  • Introduction: Since 1996, Dr. James Norman has successfully performed mimimally invasive radio-guided parathyroidectomy(MIRP) using intraoperative nuclear mapping with $^{99m}Tc$ sestamibi scanning and radioactivity detection probe. Objectives: We aimed to introduce this new surgical technique and evaluate it's efficacy by our own experiences. Method: From May to October 1999, five consecutive patients with primary hyperparathyroidism underwent parathyroidectomy by using modified MIRP technique. $^{99m}Tc$ sestamibi scanning was performed 1.0 or 1.5 hour before operation. After intraoperative localization of the tumor under the guidance of quantitative gamma counting with a NEVIGATOR probe, an unilateral small skin incision(3.0-4.0cm) was placed. Without a skin flap, the strap muscle was directly divided with the use of a Harmonic scalpel. After careful dissection, the parathyroid tumor was removed. Result: In all patients, a single adenoma could be easily detected and removed by this new technique. Mean incision length was 3.2cm(3.0-4.0cm) and operative time ranged from 40 to 110minute. All the patients were discharged within 2 days of surgery without any complication. Conclusion: This new operative technique could become the most minimally invasive alternative to the standard operative procedure for parathyroid adenoma.

  • PDF