• Title/Summary/Keyword: Lung perfusion

Search Result 139, Processing Time 0.041 seconds

A Case of Hepatopulmonary Syndrome Diagnosed by $^{99m}Tc-MAA$ Perfusion Lung Scan ($^{99m}Tc-MAA$ 폐관류스캔으로 진단한 간폐증후군)

  • Oh, Hyung-Tae;Lee, Moo-Yong;Song, Il-Han;Park, Seok-Gun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.203-208
    • /
    • 2002
  • In patients with chronic liver disease, hepatopulmonary syndrome, the right to left shunt without previous pulmonary and cardiac disease, can develope and cause respiratory distress. Tools to prove shunt are contrast echocardiography, pulmonary angiography, and $^{99m}Tc-MAA$ perfusion lung scan. Among them, $^{99m}Tc-MAA$ scan is a simple and safe method detecting the right to left shunt. At the same time, quantitation of shunt amount is possible by this method. We report a case of hepatopulmonary syndrome confirmed by $^{99m}Tc-MAA$ scan and contrast echocardiography with review of literlatures.

Optimal Attenuation Threshold for Quantifying CT Pulmonary Vascular Volume Ratio

  • Hyun Woo Goo;Sang Hyub Park
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.756-763
    • /
    • 2020
  • Objective: To evaluate the effects of attenuation threshold on CT pulmonary vascular volume ratios in children and young adults with congenital heart disease, and to suggest an optimal attenuation threshold. Materials and Methods: CT percentages of right pulmonary vascular volume were compared and correlated with percentages calculated from nuclear medicine right lung perfusion in 52 patients with congenital heart disease. The selected patients had undergone electrocardiography-synchronized cardiothoracic CT and lung perfusion scintigraphy within a 1-year interval, but not interim surgical or transcatheter intervention. The percentages of CT right pulmonary vascular volumes were calculated with fixed (80-600 Hounsfield units [HU]) and adaptive thresholds (average pulmonary artery enhancement [PAavg] divided by 2.50, 2.00, 1.75, 1.63, 1.50, and 1.25). The optimal threshold exhibited the smallest mean difference, the lowest p-value in statistically significant paired comparisons, and the highest Pearson correlation coefficient. Results: The PAavg value was 529.5 ± 164.8 HU (range, 250.1-956.6 HU). Results showed that fixed thresholds in the range of 320-400 HU, and adaptive thresholds of PAavg/1.75-1.50 were optimal for quantifying CT pulmonary vascular volume ratios. The optimal thresholds demonstrated a small mean difference of ≤ 5%, no significant difference (> 0.2 for fixed thresholds, and > 0.5 for adaptive thresholds), and a high correlation coefficient (0.93 for fixed thresholds, and 0.91 for adaptive thresholds). Conclusion: The optimal fixed and adaptive thresholds for quantifying CT pulmonary vascular volume ratios appeared equally useful. However, when considering a wide range of PAavg, application of optimal adaptive thresholds may be more suitable than fixed thresholds in actual clinical practice.

Isolated Lung Perfusion with Cisplatin in Rabbit - evaluation of pharmacokinetics and long term pathologic changes of the lung- (가토에서 Cisplatin을 사용한 분리 폐 관류 -약리학적 변화 및 폐의 장기적 병리학적 변화에 관한 연구-)

  • 김관민;김진국;한정호
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.613-620
    • /
    • 1999
  • Background: Recently, regional or isolated organ perfusion is being studied again as a drug administration modality which is able to reduce systemic toxicity while delivering high-dose chemotherapeutic agents. This research was planned to evaluate the pharmacokinetics and long-term pathologic changes of the lung in isolated lung perfusion (ILP) with cisplatin. Material and Method: Twenty-five New Zealand white rabbits were divided into 2 groups (Group I: 10, Group II: 15). The groups were then subdivided into 2 and 3 subgroups of 5 rabbits. In group I, tissue samples of the lung and kidney, and systemic blood for platinum concentration measurement were taken 30 minutes after systemic intravenous infusion of cisplatin (5 mg/kg) and isolated lung perfusion in each 5 rabbits. In 2 subgroups of group II, lung tissues for pathologic exams were taken 30 minutes and 1 week after ILP in each 5 rabbits, which received 10% pentastarch solution only and cisplatin, respectively. In the other subgroups, lung biopsy was undertaken 4 weeks after ILP with cisplatin. Result: When cisplatin was infused via systemic vein, the platinum concentration in the lung, kidney and plasma were 1.50${\pm}$0.43 $\mu\textrm{g}$/g, 7.65${\pm}$2.49 $\mu\textrm{g}$/g, 1.19${\pm}$0.03 $\mu\textrm{g}$/ml, respectively. However, the platinum concentration in the lung was about 50 times higher (75.43${\pm}$11.47 $\mu\textrm{g}$/g) than that of intravenous infusion group, and those in the kidney and plasma were decreased (1.30${\pm}$ 0.35 $\mu\textrm{g}$/g, 0.13${\pm}$0.02 $\mu\textrm{g}$/ml) when cisplatin was introduced through ILP. Pathologic change in the treated lung with ILP was characterized by the medial hypertrophy of the pulmonary arterioles and interstitial eosinophilic infiltration, which was not dependent on cisplatin

  • PDF

Usefulness of Hepatocellular Carcinoma by Hepatic Arterial Perfusion Scintigraphy with $^{99m}Tc$-MAA ($^{99m}Tc$-MAA를 이용한 간세포암의 간동맥 관류 스캔의 유용성)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.155-158
    • /
    • 2010
  • Purpose: $^{99m}Tc$-macroaggregated albumin (MAA) hepatic arterial perfusion scintigraphy was known for useful method to evaluate patients receiving intraarterial chemotherapy for liver cancer. This study evaluate about usefulness of normal liver on hepatocellular carcinoma (HCC) from HCC patients. This study is to see the usefullness of Hepatic Arterial Perfusion Scintigraphy (HAPS) by measuring mass size, shape, lung shunting and tumor to normal ratio (T/N ratio) in relative blood stream of HCC patients compared with HCC on normal liver. Materials and Methods: From June 2009 to September 2009, HAPS studies were performed on 7 patients (men 6, women 1, mean 64) who were diagnosed HCC. HAPS was performed after proper hepatic artery $^{99m}Tc$-MAA of 5 mCi (185 MBq) injection by catheter. We performed anterior, posterior, both lateral view, SPECT of chest and abdomen. Then we set up ROI and calculated lung shunting, T/N ratio for each count, count/pixel (mean value). Results: Tumor and liver size analyzed by ROI of anterior, posterior view are 2.0-10.8 cm (mean 3.75 cm), 8.8-18.5 cm (mean 14.6 cm). T/N ratio analyzed by total tumor and total normal mean value are 2.41-5.76 (mean 3.8). lung shunting analyzed by total liver count is 3.14-13.92% (mean 6.77%). Conclusion: HAPS with $^{99m}Tc$-MAA can evaluate mass size, location, quantitative analysis through T/N ratio. also HAPS can evaluate detection of arteriovenous shunt through lung uptake before radioisotope therapy. Therefore HAPS with $^{99m}Tc$-MAA can be useful method in aspect of evaluation and treatment of HCC.

  • PDF

Hepatic Arterial Perfusion Scintigraphy with Tc-99m-Macroaggregated Albumin in Hepatocellular Carcinoma (Tc-99m-MAA를 이용한 간세포암의 경동맥 관류스캔)

  • Kim, Gang-Deuk;Sohn, Kwang-Joon;Min, Kyung-Yoon;Kwon, Young-Mi;Kim, Chang-Guhn;Noh, Byung-Suk;Won, Jong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.350-356
    • /
    • 1994
  • Purpose : Hepatic arterial perfusion scintigraphy with Tc-99m-macroggregated albumin (HAPS) study was carried out in 16 patients with hepatocellular carcinoma(HCC) and in six patients without liver tumor to evaluate HAPS findings of hepatocellular carcinoma and usefullness of HAPS. Materials and Methods : HAPS with planar and SPECT study were performed in 22 patients after conventional hepatic or celiac arteriography. For HAPS study, 4-5 mCi of MAA mixed with 2ml of saline was injected into proper hepatic artery or its distal branches at the rate of approximately 1ml/sec. We analysed 21 HCCs over 2cm in diameter(average diameter; 6.4cm) and 17 of 21 HCCs were over 4cm in diameter(Table 1). CT, sonography and angiography were performed within two week in all 16 patients and liver scan was performed in 12 patients. Results : Three different pattern of tumor perfusion were observed in 16 patients with HCC (Table 2). 1) diffuse increased perfusion in 16 of 21(76%)(Fig. 1) 2) increased peripheral perfusion in 4 of 21(19%) (Fig. 2) 3) diffuse decreased perfusion in 1 of 21 (5%) Arteriovenous shunt indicated by lung uptake of MAA were observed in 9 of 16(56%)(Fig. 4). In contrast, angiography demonstrates arteriovenous shunt in 2 of 16(13%). There was no accumulation of radioactivity on RBC-blood pool scan in all six patients with HCC examined (Fig. 1). Conclusion : HAPS is useful study in evaluation of perfusion pattern or vascularity of HCC and in detection of arteriovenous shunt.

  • PDF

Clinical Observation of Perfusion Lung Scan with $^{131}IMAA$ and Ventilation tung Scan with $^{198}Au$ Colloid in various Lung Diseases (각종폐질환(各種肺疾患)에 있어서의 $^{131}I$표지대응집인혈청(標識大凝集賤集人血淸)알부민($^{131}I$-Macroaggregated Albumin)을 이용(利用)한 폐혈류(肺血流)스캐닝 및 교질상방사성금(膠質狀放射性金)-198($^{198}Au$ colloid)을 이용(利用)한 폐흡입(肺吸入)스캐닝에 관(關)한 고찰(考察))

  • Koh, C.S.;Rhee, C.H.;Hong, C.K.;Kim, D.J.
    • 대한핵의학회:학술대회논문집
    • /
    • 1967.11a
    • /
    • pp.104.2-104.2
    • /
    • 1967
  • PDF

A Study on Pulmonary Toxic Effect of High-Dose Cisplatin Administered by Isolated Lung Perfusion in Dogs (잡견에서 분리폐관류 방법으로 투여된 고농도 cisplatin의 페독성에 관한 연구)

  • 김관민;한정호;김주현
    • Journal of Chest Surgery
    • /
    • v.33 no.9
    • /
    • pp.697-706
    • /
    • 2000
  • Background: Isolated lung perfusion(ILP) was developed as a new treatment approach to non-resectable primary or metastatic lung cancer, because of its ability to reduce systemic toxicity while delivering high-dose chemotherapeutic agents to the target organs. This research was planned to evaluate the direct toxic effect of high-dose cisplatin to the lung tissue during isolated lung perfusion. Material and Method: Fifteen mongrel dogs were divided in the perfusate for 40 minutes. The second group was composed of 5 mongrel dogs which underwent ILP with cisplatin 2.5 mg/Kg added to the perfusate for 30 minutes and 10 minutes with washing solution without cisplatin. The third group underwent the same procedure as the second group except cisplatin 5.0 mg/Kg in the perfusate. Activities of serum angiotensin converting enzyme(ACE), tumor necrosis factor-$\alpha$(TNF-$\alpha$), and concentration of serum lactate dehydrogenase(LDH) and blood urea nitrogen/creatinine (BUN/Cr) were analyzed in each groups at the time of pre-perfusion, 1 hour, 1 day, 1 week, and 2 weeks after ILP. Result: Serum ACE activities before and 1 hour, 1 day, 1 week, and 2 weeks after ILP in control group were 45.1$\pm$6.3, 44.6$\pm$9.3, 46.7$\pm$9.5, 50.8$\pm$9.1, 46.1$\pm$4.3 U/L. Those in cisplatin 2.5 and 5.0 mg/Kg groups were 49.4$\pm$12.6, 39.0$\pm$8.6, 42.3$\pm$15.9, 50.0$\pm$2.6, 53.8$\pm$8.3 and 55.5$\pm$12.3, 47.0$\pm$6.3, 45.1$\pm$6.9, 74.8$\pm$19.5, 60.2$\pm$12.0 U/L, respectively. Serum TNF-$\alpha$ activities in each group before and after ILP were 5.0$\pm$1.5 / 7.7$\pm$2.2 / 6.6$\pm$2.5 / 4.3$\pm$1.3 / 5.2$\pm$1.1(control), 8.7$\pm$1.6 / 9.9$\pm$2.2 / 7.9$\pm$1.5 / 6.3$\pm$2.2 / 7.4$\pm$2.4 (cisplatin 2.5 mg/Kg), and 6.9$\pm$0.7 / 8.9$\pm$3.4 / 7.9$\pm$4.0 / 3.3$\pm$0.9 / 5.8$\pm$1.3 pg/ml(cisplatin 5.0 mg/Kg). Mean LDH levels of each group were 225.7 / 271.3 / 328.9 / 350.8 / 255.7(control), 235.7 / 265.7 / 336.0 / 379.5 / 299.2 (cisplatin 2.5 mg/Kg), and 259.6 / 285.2 / 340.6 / 433.4 / 292.4 IU/L(cisplatin 5.0 mg/Kg). So there was no significant difference in serum ACE, TNF-$\alpha$, and LDH activity changes after ILP between the 3 groups. And, there was no significant changes in BUN/Cr in each groups, which was independent of ILP and perfused concentration of cisplatin. In addition, all dogs survived the ILP and there was no significant evidence of pulmonary vascular injury after 2 weeks of ILP with cisplatin. Conclusion: There was no harmful effect of cisplatin to the lund tissue of the mongrel dog up to 5.0 mg/Kg in perfusate. Therefore, it is perceived to be safe and effective to deliver high-dose cisplatin to the lung without pulmonary toxicity and renal damage with ILP.

  • PDF

Magnetic Resonance Imaging in Thorax (흉부의 자기공명영상)

  • Choi, Byoung Wook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.6
    • /
    • pp.571-584
    • /
    • 2004
  • Magnetic Resonance Imaging (MRI) is one of the most advanced imaging techniques in clinical and research medicine. However, clinical application of MRI to the lung or thorax has been limited due to various drawbacks. Low signal intensity of the lung and cardiac and respiratory movements are the most serious problems with MRI in thorax. Nevertheless, MRI is superior to CT in some selected patients with thoracic diseases. The role of clinical MRI in thoracic disease has been widened with improvement of MR equipments and development of new pulse sequences. Otherwise, functional assessment of lung by MRI has been studied for the last decade. These include perfusion MRI with or without contrast enhancement and ventilation MRI with oxygen-enhancement or hyperpolarized noble gas, $^3He$ and $^{129}Xe$.