Usefulness Evaluation of Low-dose CT for Emphysema : Compared with High-resolution CT (폐기종에 대한 저선량 CT의 유용성 평가: 고해상도 CT와 비교)

  • Lee, Won-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.329-336
    • /
    • 2016
  • The purpose of this study was to evaluate the usefulness of low-dose CT (LDCT) for emphysema compared with high-resolution CT (HRCT). Measurements of radiation dose and noise were repeated 3 times in same exposure condition which was similar with obtaining HRCT and LDCT images. We analysed reading results of 146 subjects. Six images per participants selected for emphysema grading. Emphysema was graded for all 6 zones on the left and right sides of the lungs by the consensus reading of two chest radiologists using a 4-point scale. Between the HRCT and LDCT images, diagnostic differences and agreements for emphysema were analyzed by McNemar's and unweighted kappa tests, and radiation doses and noise by a Mann-Whitney U-test, using the SPSS 19.0 program. Radiation dose from HRCT was significantly higher than that of LDCT, but the noise was significantly lower in HRCT than in LDCT. Diagnostic agreement for emphysema between HRCT and LDCT images was excellent (k-value=0.88). Emphysema grading scores were not significantly different between HRCT and LDCT images for all six lung zones. Emphysema grading scores from LDCT images were significantly correlated with increased scores on HRCT images (r=0.599, p < 0.001). Considering the tradeoff between radiation dose and image noise, LDCT could be used as the gold standard method instead of HRCT for emphysema detection and grading.

Feature-based Non-rigid Registration between Pre- and Post-Contrast Lung CT Images (조영 전후의 폐 CT 영상 정합을 위한 특징 기반의 비강체 정합 기법)

  • Lee, Hyun-Joon;Hong, Young-Taek;Shim, Hack-Joon;Kwon, Dong-Jin;Yun, Il-Dong;Lee, Sang-Uk;Kim, Nam-Kug;Seo, Joon-Beom
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.237-244
    • /
    • 2011
  • In this paper, a feature-based registration technique is proposed for pre-contrast and post-contrast lung CT images. It utilizes three dimensional(3-D) features with their descriptors and estimates feature correspondences by nearest neighborhood matching in the feature space. We design a transformation model between the input image pairs using a free form deformation(FFD) which is based on B-splines. Registration is achieved by minimizing an energy function incorporating the smoothness of FFD and the correspondence information through a non-linear gradient conjugate method. To deal with outliers in feature matching, our energy model integrates a robust estimator which discards outliers effectively by iteratively reducing a radius of confidence in the minimization process. Performance evaluation was carried out in terms of accuracy and efficiency using seven pairs of lung CT images of clinical practice. For a quantitative assessment, a radiologist specialized in thorax manually placed landmarks on each CT image pair. In comparative evaluation to a conventional feature-based registration method, our algorithm showed improved performances in both accuracy and efficiency.

Feasibility of Shrinking Field Radiation Therapy through 18F-FDG PET/CT after 40 Gy for Stage III Non-Small Cell Lung Cancers

  • Ding, Xiu-Ping;Zhang, Jian;Li, Bao-Sheng;Li, Hong-Sheng;Wang, Zhong-Tang;Yi, Yan;Sun, Hong-Fu;Wang, Dong-Qing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.1
    • /
    • pp.319-323
    • /
    • 2012
  • Objective: To explore the feasibility of shrinking field technique after 40 Gy radiation through 18F-FDG PET/CT during treatment for patients with stage III non-small cell lung cancer (NSCLC). Methods: In 66 consecutive patients with local-advanced NSCLC, 18F-FDG PET/CT scanning was performed prior to treatment and repeated after 40 Gy. Conventionally fractionated IMRT or CRT plans to a median total dose of 66Gy (range, 60-78Gy) were generated. The target volumes were delineated in composite images of CT and PET. Plan 1 was designed for 40 Gy to the initial planning target volume (PTV) with a subsequent 20-28 Gy-boost to the shrunken PTV. Plan 2 was delivering the same dose to the initial PTV without shrinking field. Accumulated doses of normal tissues were calculated using deformable image registration during the treatment course. Results: The median GTV and PTV reduction were 35% and 30% after 40 Gy treatment. Target volume reduction was correlated with chemotherapy and sex. In plan 2, delivering the same dose to the initial PTV could have only been achieved in 10 (15.2%) patients. Significant differences (p<0.05) were observed regarding doses to the lung, spinal cord, esophagus and heart. Conclusions: Radiotherapy adaptive to tumor shrinkage determined by repeated 18F-FDG PET/CT after 40 Gy during treatment course might be feasible to spare more normal tissues, and has the potential to allow dose escalation and increased local control.

Dosimetric Effects of Low Dose 4D CT Using a Commercial Iterative Reconstruction on Dose Calculation in Radiation Treatment Planning: A Phantom Study

  • Kim, Hee Jung;Park, Sung Yong;Park, Young Hee;Chang, Ah Ram
    • Progress in Medical Physics
    • /
    • v.28 no.1
    • /
    • pp.27-32
    • /
    • 2017
  • We investigated the effect of a commercial iterative reconstruction technique (iDose, Philips) on the image quality and the dose calculation for the treatment plan. Using the electron density phantom, the 3D CT images with five different protocols (50, 100, 200, 350 and 400 mAs) were obtained. Additionally, the acquired data was reconstructed using the iDose with level 5. A lung phantom was used to acquire the 4D CT with the default protocol as a reference and the low dose (one third of the default protocol) 4D CT using the iDose for the spine and lung plans. When applying the iDose at the same mAs, the mean HU value was changed up to 85 HU. Although the 1 SD was increased with reducing the CT dose, it was decreased up to 4 HU due to the use of iDose. When using the low dose 4D CT with iDose, the dose change relative to the reference was less than 0.5% for the target and OARs in the spine plan. It was also less than 1.1% in the lung plan. Therefore, our results suggests that this dose reduction technique is applicable to the 4D CT image acquisition for the radiation treatment planning.

Significance Evaluation of Lung Volume and Pulmonary Dysfunction (폐용적과 폐기능 환기장애에 대한 유의성 평가)

  • Ji-Yul Kim;Soo-Young Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.767-773
    • /
    • 2023
  • To In this study, we sought to evaluate related factors affecting lung volume and their significance in pulmonary function and ventilation disorders. As experimental subjects, 206 normal adult men and women who underwent a low-dose chest CT scan and a spirometry test were selected at the same time. The experimental method was to measure lung volume using lung CT images obtained through a low-dose chest CT scan using deep learning-based AVIEW. Measurements were made using the LCS automatic diagnosis program. In addition, the results of measuring lung function were obtained using a spirometer, and gender and BMI were selected as related factors that affect lung volume, and significance was evaluated through an independent sample T-test with lung volume. As a result of the experiment, it was confirmed that in evaluating lung volume according to gender, all lung volumes of men were larger than all lung volumes of women. he result of an independent samples T-test using the respective average values for gender and lung volume showed that all lung volumes were larger in men than in women, which was significant (p<0.001). And in the evaluation of lung volume according to BMI index, it was confirmed that all lung volumes of adults with a BMI index of 24 or higher were larger than all lung volumes of adults with a BMI index of less than 24. However, the independent samples T-test using the respective average values for BMI index and lung volume did not show a significant result that all lung volumes were larger in BMI index 24 or higher than in BMI index less than 24 (p<0.055). In the evaluation of lung volume according to the presence or absence of pulmonary ventilation impairment, it was confirmed that all lung volumes of adults with normal pulmonary function ventilation were larger than all lung volumes of adults with pulmonary ventilation impairment. And as a result of the independent sample T-test using the respective average values for the presence or absence of pulmonary ventilation disorder and lung volume, the result was significant that all lung volumes were larger in adults with normal pulmonary function ventilation than in adults with pulmonary function ventilation disorder (p <0.001). Lung volume and spirometry test results are the most important indicators in evaluating lung health, and using these two indicators together to evaluate lung function is the most accurate evaluation method. Therefore, it is expected that this study will be used as basic data by presenting the average lung volume for adults with normal ventilation and adults with impaired lung function and ventilation in similar future studies on lung volume and vital capacity testing.

Measurement of Variation in Water Equivalent Path Length by Respiratory Organ Movement

  • Minohara, Shinichi;Kanai, Tatsuaki;Endo, Masahiro;Kato, Hirotoshi;Miyamoto, Tadaaki;Tsujii, Hirohiko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.90-93
    • /
    • 2002
  • In particle radiotherapy, a shape of the beam to conform the irradiation field is statically defined by the compensator, collimator and potal devices at the outside of the patient body. However the target such as lung or liver cancer moves along with respiration. This increases the irradiated volume of normal tissue. Prior discussions about organ motions along with respiration have been mainly focused on inferior-superior movement that was usually perpendicular to beam axis. On the other hand, the change of the target depth along the beam axis is very important especially in particle radiotherapy, because the range end of beam (Bragg peak) is so sharp as to be matched to distal edge of the target. In treatment planning, the range of the particle beam inside the body is calculated using a calibration curve relating CT number and water equivalent path length (WEL) to correct the inhomogeneities of tissues. The variation in CT number along the beam path would cause the uncertainties of range calculation at treatment planning for particle radiotherapy. To estimate the uncertainties of the range calculation associated with patient breathing, we proposed the method using sequential CT images with respiration waveform, and analyzed organ motions and WELs at patients that had lung or liver cancer. The variation of the depth along the beam path was presented in WEL rather than geometrical length. In analyzed cases, WELs around the diaphragm were remarkably changed depending on the respiration, and the magnitude of these WEL variations was almost comparable to inferior-superior movement of diaphragm. The variation of WEL around the lung was influenced by heartbeat.

  • PDF

Automatic Lung Segmentation using Hybrid Approach (하이브리드 접근 기법을 사용한 자동 폐 분할)

  • Yim, Yeny;Hong, Helen;Shin, Yeong-Gil
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.7
    • /
    • pp.625-635
    • /
    • 2005
  • In this paper, we propose a hybrid approach for segmenting the lungs efficiently and automatically in chest CT images. The proposed method consists of the following three steps. first, lungs and airways are extracted by two- and three-dimensional automatic seeded region growing and connected component labeling in low-resolution. Second, trachea and large airways are delineated from the lungs by two-dimensional morphological operations, and the left and right lungs are identified by connected component labeling in low-resolution. Third, smooth and accurate lung region borders are obtained by refinement based on image subtraction. In experiments, we evaluate our method in aspects of accuracy and efficiency using 10 chest CT images obtained from 5 patients. To evaluate the accuracy, we Present results comparing our automatic method to manually traced borders from radiologists. Experimental results show that proposed method which use connected component labeling in low-resolution reduce processing time by 31.4 seconds and maximum memory usage by 196.75 MB on average. Our method extracts lung surfaces efficiently and automatically without additional processing like hole-filling.

Spect-guidance to Reduce Radioactive Dose to Functioning Lung for Stage III Non-small Cell Lung Cancer

  • Wang, Zhong-Tang;Wei, Li-Li;Ding, Xiu-Ping;Sun, Ming-Ping;Sun, Hong-Fu;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.1061-1065
    • /
    • 2013
  • Objective: To investigate the treatment effect of additional information obtained by single photon emission computed tomography (SPECT) lung perfusion imaging (LPI) in the radiotherapy planning process for patients with stage III non-small cell lung cancer (NSCLC). Methods: 39 patients with stage III NSCLC were enrolled. Gross tumor volume (GTV) was outlined by SPECT/CT images, SPECT-LPIs being used to define functional lung (FL) and non-functional lung (NFL) regions. Two sets of IMRT plans were designed to deliver 64Gy to PTV. One was a regular IMRT plan using CT images only (Plan 1), and the other was a corresponding IMRT plan using co-registered images (Plan 2). $FL_{Vx}$ (the % volume of functional lung receiving ${\geq}$x Gy) and $WL_{Vx}$ (% volume of whole lung to receive ${\geq}$x Gy) were compared by paired Student's t test. Kendalls correlation was used to analyze the factor (s) related with the FLV20 decrease. Results: Compared with plan 1, both $WL_{Vx}$ and $FL_{Vx}$ were decreased in plan 2. $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V30}$ and $WL_{V35}$ decreased 9.7%, 13.8%, 17.2%, 12.9%, 9.8% and 9.8%, and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ and $FL_{V35}$ decreased 10.8%, 14.6%, 17.3%, 14.5%, 14.5% and 10.5%. $FL_{Vx}$ decreased significantly compared with $WL_{Vx}$. There were significant differences in $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V3}$ and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ between plan 1 and plan 2 (P=0.002, 0.000, 0.000, 0.005, 0.027 and 0.002, 0.000, 0.000, 0.006, 0.010). According to Kendall correlation analysis, NFL had a negative relation with the percentage FLV20 decrease (r=-0.559, P<0.01), while the distance of PTV and NFL center had a significantly positive relation with the percentage of FLV20 decrease (r=0.768, P<0.01). Conclusion: Routine use of SPECT-LPI for patients undergoing radiotherapy planning for stage III NSCLC appears warranted.

Multimodality Image Registration and Fusion using Feature Extraction (특징 추출을 이용한 다중 영상 정합 및 융합 연구)

  • Woo, Sang-Keun;Kim, Jee-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.2 s.46
    • /
    • pp.123-130
    • /
    • 2007
  • The aim of this study was to propose a fusion and registration method with heterogeneous small animal acquisition system in small animal in-vivo study. After an intravenous injection of $^{18}F$-FDG through tail vain and 60 min delay for uptake, mouse was placed on an acryl plate with fiducial markers that were made for fusion between small animal PET (microPET R4, Concorde Microsystems, Knoxville TN) and Discovery LS CT images. The acquired emission list-mode data was sorted to temporally framed sinograms and reconstructed using FORE rebining and 2D-OSEM algorithms without correction of attenuation and scatter. After PET imaging, CT images were acquired by mean of a clinical PET/CT with high-resolution mode. The microPET and CT images were fusion and co-registered using the fiducial markers and segmented lung region in both data sets to perform a point-based rigid co-registration. This method improves the quantitative accuracy and interpretation of the tracer.

  • PDF

Hypermetabolism of Compensatory Laryngeal Muscles in Unilateral Vocal Cord Palsy: Comparison Study between Speech and Silence with Normal Subjects by Co-registered PET-CT Fusion Images (일측 성대마비 환자의 보상기전에 관여하는 후두내근육 : PET-CT 융합 영상을 사용한 정상군과의 발성시 및 비발성시의 비교)

  • Pai, Moon-Sun;Kim, Hyon-Kyong;Kim, Han-Su
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.23-27
    • /
    • 2006
  • Purpose: There are a few case reports on asymmetric vocal cord uptake on FDG-PET in patients with unilateral vocal cord paralysis, which could be a potential pitfall in the interpretation of FDG-PET images. We evaluated the metabolic activity of laryngeal muscles of patients with unilateral vocal cord paralysis in comparison to normal controls during both speech and silence. Methods: Eleven patients with unilateral vocal cord palsy (thyroldectomy=7, lung cancer=1, others=3) and 12 normal controls underwent FDG-PET with usual protocol. They were divided into two groups respectively; one group read books aloud for 20 minutes (phonation group) and the other kept silence (non-phonation groups) after FDG injection. Recent neck CT scan were co-registered with FDG-PET to produce PET-CT fusion images to elaborate small laryngeal muscles. Results: In patients with unilateral vocal cord palsy, contralateral non-paralyzed vocal cord showed hypermetabolism mainly on thyroarytenoid muscle, more intensely with phonation group ($SUV=5.88{\pm}2.65$) than with non-phonation group ($SUV=2.30{\pm}0.39$). Normal control subjects showed hypermetabolism ($3.68{\pm}0.96$) in interarytenoid muscle and symmetric mild hypermetabolism in both lateral cricoarytenoid muscles in only phonation group. Conclusion: FDG-PET with fusion images using CT scan in patients with unilateral vocal cord paralysis showed hypermetabolism of contralateral non-paralyzed thyroarytenoid muscle, suggesting compensatory action during phonation. Phonation durung FDG PET study enhanced FDG uptake on different laryngeal muscles between patients with unilateral vocal cord paralysis and normal subjects.