• Title/Summary/Keyword: Lung, CT

Search Result 864, Processing Time 0.023 seconds

Migrating Lobar Atelectasis of the Right Lung: Radiologic Findings in Six Patients

  • Tae Sung Kim;Kyung Soo Lee;Jung Hwa Hwang;In Wook Choo;Jae Hoon Lim
    • Korean Journal of Radiology
    • /
    • v.1 no.1
    • /
    • pp.33-37
    • /
    • 2000
  • Objective: To describe the radiologic findings of migrating lobar atelectasis of the right lung. Materials and Methods: Chest radiographs (n = 6) and CT scans (n = 5) of six patients with migrating lobar atelectasis of the right lung were analyzed retrospectively. The underlying diseases associated with lobar atelectasis were bronchogenic carcinoma (n = 4), bronchial tuberculosis (n = 1), and tracheobronchial amyloidosis (n = 1). Results: Atelectasis involved the right upper lobe (RUL) (n = 3) and both the RUL and right middle lobe (RML) (n = 3). On supine anteroposterior radiographs (n = 5) and on an erect posteroanterior radiograph (n = 1), the atelectatic lobe(s) occupied the right upper lung zone, with a wedge shape abutting onto the right mediastinal border. On erect posteroanterior radiographs (n = 6), the heavy atelectatic lobe(s) migrated downward, forming a peri- or infrahilar area of increased opacity and obscuring the right cardiac margin. Erect lateral radiographs (n = 4) showed inferior shift of the anterosuperiorly located atelectatic lobe(s) to the anteroinferior portion of the hemithorax. Conclusion: Atelectatic lobe(s) can move within the hemithorax according to changes in a patient s position. This process involves the RUL or both the RUL and RML.

  • PDF

Magnetic Resonance Imaging in Thorax (흉부의 자기공명영상)

  • Choi, Byoung Wook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.6
    • /
    • pp.571-584
    • /
    • 2004
  • Magnetic Resonance Imaging (MRI) is one of the most advanced imaging techniques in clinical and research medicine. However, clinical application of MRI to the lung or thorax has been limited due to various drawbacks. Low signal intensity of the lung and cardiac and respiratory movements are the most serious problems with MRI in thorax. Nevertheless, MRI is superior to CT in some selected patients with thoracic diseases. The role of clinical MRI in thoracic disease has been widened with improvement of MR equipments and development of new pulse sequences. Otherwise, functional assessment of lung by MRI has been studied for the last decade. These include perfusion MRI with or without contrast enhancement and ventilation MRI with oxygen-enhancement or hyperpolarized noble gas, $^3He$ and $^{129}Xe$.

DOUBLE PULMONARY BLASTOMAS - A CASE REPORT - (다발성폐아세포종 -수술치험 1례 -)

  • 김태식;조원민;류영진;김욱진;최영호;김학제;이주한;김한겸
    • Korean Journal of Bronchoesophagology
    • /
    • v.2 no.2
    • /
    • pp.248-252
    • /
    • 1996
  • Pulmonary blastoma is rare malignant neoplasm usually situated peripherally in lung and composed of epithelial and mesenchymal components that resemble the lung at about 3 months gestation. Fortysix year-old man had no symptoms and signs, but solitary pulmonary nodule was found accidentally in a routine simple chest X-ray occupying right upper lung field. Preoperative chest CT-guided aspiration cytology revealed adenocarcinoma. We had done right upper lobectomy with Iymph node dissecton therapeutically. Final postoperative pathology reported this tumor as double pulmonary blastomas(well differentiated fetal adenocarcinoma). We report a case of pulmonary blastoma with review of literature.

  • PDF

Occupational Lung Diseases: Spectrum of Common Imaging Manifestations

  • Alexander W. Matyga;Lydia Chelala;Jonathan H. Chung
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.795-806
    • /
    • 2023
  • Occupational lung diseases (OLD) are a group of preventable conditions caused by noxious inhalation exposure in the workplace. Workers in various industries are at a higher risk of developing OLD. Despite regulations contributing to a decreased incidence, OLD remain among the most frequently diagnosed work-related conditions, contributing to significant morbidity and mortality. A multidisciplinary discussion (MDD) is necessary for a timely diagnosis. Imaging, particularly computed tomography, plays a central role in diagnosing OLD and excluding other inhalational lung diseases. OLD can be broadly classified into fibrotic and non-fibrotic forms. Imaging reflects variable degrees of inflammation and fibrosis involving the airways, parenchyma, and pleura. Common manifestations include classical pneumoconioses, chronic granulomatous diseases (CGD), and small and large airway diseases. Imaging is influenced by the type of inciting exposure. The findings of airway disease may be subtle or solely uncovered upon expiration. High-resolution chest CT, including expiratory-phase imaging, should be performed in all patients with suspected OLD. Radiologists should familiarize themselves with these imaging features to improve diagnostic accuracy.

Evaluation 4D-CT Simulation used of Motion Organ and Tumor for Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 4D-CT simulation을 이용한 동적장기와 종양 움직임 평가)

  • Kim, Seung-Chul;Kim, Min-A
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.395-402
    • /
    • 2015
  • when the radiation therapy of chest and abdomen, evaluation of the tumor motion and the data was used to minimize damage to normal tissues by separating the tumor and normal tissue and maximize tumor therapeutic effect. Lung and liver cancer each 20 patients based on the 50% top phase using 4D-CT simulation and Light speed-16 of shooting equipment 30 ~ 70 % gating phase interval and 0 ~90 % movement in the full phase interval was measured. If the full phase 0 ~ 90% with gating phase 30~70% of tumors in the liver and lung is shown the biggest difference compared to the motion and the size of the GTV was the largest difference in the I(inferior), full phase 0~90% degree of tumor motion only when a relatively large, gating phase to 30~70% of the tumor when the movement has been found that the reduced average 7.1mm. In the 4D-CT simulation comparing the motion value when the full phase 0~90 % and gating phase 30~70 % when the motion value, twice in the gating phase 30~70 % more than full phase 0~90 % showed a small movement value. The exposure to normal tissues, based on the results obtained from the 4D-CT simulation can be significantly alleviated, After treatment will reduce pain and disability in patients with radiation is expected to be able to effective treatment.

Quality Assessment for Elbow CT scan by positioning and respiratory control (팔꿈치관절 CT검사에서 환자 자세 및 호흡에 따른 화질평가)

  • Lim, Jong-Chun;Park, Sang-Hyun;Lee, In-Jae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.110-114
    • /
    • 2017
  • Because the arm can't be sutured due to fracture during a elbow CT scan, a CT scan is proceeded in a state of abdomen and L-spire are overlapped which beam hardening artifact is done many times, and it often lowers the quality of elbow CT images. So there are many difficulties in reading and due to increase in radiation dose from it, the number of patient's exposure keeps increasing. In this research, it plans to improve the quality of the images by avoiding overlap with abdomen, and increasing the number of photon overlapped with lung field which the line attenuation is relatively small. The way of experiment is based on patient's right elbow and place him as head first position, then place his elbow at L2-3 level in supine position, turn about 30 degrees to the left in non-control breathing and in supine position, and compared with full inspiration after overlapping with lung. After figuring out the average value and standard deviation data using Image J program 5 times each for 16, 128 channels, the evaluation is proceeded by measuring each of CNR, MSR are statistically analyzed using SPSS program. Therefore, through positioning and inspiration during elbow CT scan, the way of inspection minimized the exposure radiation dose, and seems to be meaningful in a way to improve the quality of the images.

Lymphopenia after Mediastinal Irradiation in Lung Cancer (폐암환자에서 종격동 방사선조사 후에 발생하는 림프구 감소증)

  • Oh Yoon Kyeong;Ha Chul Soo;Park Hee Chul;Lee Seung Il;Ryu So Yeon;Kee Keun Hong;Jeon Ho Jong
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.34-40
    • /
    • 2002
  • Purpose : This study was undertaken to retrospectively evaluate white blood ceil kinetics, especially lymphocyte depression after different treatments, and to find the correlation between immunosuppression and large blood volume and dynamic blood flow within the mediastinal radiotherapy (RT) field in lung cancer. Materials and Methods : Thirty-four patients with lung cancer were retrospectively evaluated; 10 patients had only radiotherapy (RT group), 8 had chemotherapy (CT group) and 16 fad chemotherapy and radio-therapy (RT/CT group). The mean follow-up periods of the RT-including groups (RT group and RT/CT group) and the RT-excluding group (CT group) were 6 and 8 months, respectively. Complete blood cell counts including lymphocyte percentage $(\%)$ were checked weekly during RT but less frequently during CT and after RT and after RT. Results : Changes in total white blood cell counts were not significantly different among the three groups. The lymphocyte count and lymphocyte $\%$ were much lower in the RT-including groups than in the RT-excluding group. The difference between pre-treatment and final lymphocyte count and the difference between pre-treatment and final lymphocyte $\%$ were significant (p=0.044 and p=0.037) between the RT-including groups and the RT-excluding group. Conclusion : lymphopenia was more marked after treatment containing RT than CT only. Lymphopenia may be one cause of a compromised immune system after mediastinal irradiation in lung cancer. We suggest cautiously that previous studies showing evidence of lymphocyte apoptosis after low-dose irradiation and large blood volume and dynamic blood flow within the RT fields could be somewhat related to lymphopenia after mediastinal irradiation.

Objective in Vivo Quantification of Emphysema by Thin-Section CT: Correlation with Physiologic Findings (고해상 전산화단층촬영을 이용한 폐기종의 정량적 분석: 폐기능 검사와의 비교)

  • Lee, Jee-Young;Lee, Kye-Young;Choi, Eun-Kyoung;Kim, Sang-Joon;Choi, Young-Hi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.992-999
    • /
    • 1998
  • Background: To correlate the emphysema score for quantification of the overall extent of emphysema in both lungs by CT with physiologic fingings and to get more objective and simple method to assess the extent of emphysema. Method: Thin-section CT and pulmonary function test(PFT) were performed in 17 patients with emphysema (all males, mean age, 62 years). Emphysema score was obtained as percentage of emphysematous lung area, dividing the total area of the emphysema(voxels with attenuation value less than -880, -900, -920HU, respectively) by the overall area of both lungs(voxels with attenuation value less than -400HU) with highlighting voxels using "Density mask" program. Emphysema score was calculated from whole lung(ESV) and 5 representative scans(ESR) using "Density mask", Visual emphysema score(ESV) was obtained by visual assessment from 5 representative scans. Correlation of these emphysema scores(ESW, ESR, ESV) and physiologic findings were performed, comparing the ESW with ESR and ESV. Results: ESW had correlation with DLCO(r=0.53-0.64) and $FEV_1/FVC$(r=0.42-0.57) among PFT parameters. ESR had good correlation with ESW and with PFT parameters as well. ESV did not correlate with PFT parameters except DLCO. Conclusion: CT quantification of emphysema using "density mask" correlated well with physiologic findings. To assess the severity of emphysema, both ESW and ESR are more reliable than ESV, and ESR is recommended in routine practice as it is objective, simple and reliable.

  • PDF

Preliminary Application of Synthetic Computed Tomography Image Generation from Magnetic Resonance Image Using Deep-Learning in Breast Cancer Patients

  • Jeon, Wan;An, Hyun Joon;Kim, Jung-in;Park, Jong Min;Kim, Hyoungnyoun;Shin, Kyung Hwan;Chie, Eui Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.4
    • /
    • pp.149-155
    • /
    • 2019
  • Background: Magnetic resonance (MR) image guided radiation therapy system, enables real time MR guided radiotherapy (RT) without additional radiation exposure to patients during treatment. However, MR image lacks electron density information required for dose calculation. Image fusion algorithm with deformable registration between MR and computed tomography (CT) was developed to solve this issue. However, delivered dose may be different due to volumetric changes during image registration process. In this respect, synthetic CT generated from the MR image would provide more accurate information required for the real time RT. Materials and Methods: We analyzed 1,209 MR images from 16 patients who underwent MR guided RT. Structures were divided into five tissue types, air, lung, fat, soft tissue and bone, according to the Hounsfield unit of deformed CT. Using the deep learning model (U-NET model), synthetic CT images were generated from the MR images acquired during RT. This synthetic CT images were compared to deformed CT generated using the deformable registration. Pixel-to-pixel match was conducted to compare the synthetic and deformed CT images. Results and Discussion: In two test image sets, average pixel match rate per section was more than 70% (67.9 to 80.3% and 60.1 to 79%; synthetic CT pixel/deformed planning CT pixel) and the average pixel match rate in the entire patient image set was 69.8%. Conclusion: The synthetic CT generated from the MR images were comparable to deformed CT, suggesting possible use for real time RT. Deep learning model may further improve match rate of synthetic CT with larger MR imaging data.

The Difference of Standardized Uptake Value on PET-CT According to Change of CT Parameters (PET-CT에서 CT의 관전압 및 관전류에 따른 SUV값의 변화)

  • Shin, Gyoo-Seul;Dong, Kyeong-Rae
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2007
  • Purpose : There is difference between PET and PET/CT method on their transmission image for attenuation correction. The CT image is used for attenuation correction on PET/CT and the parameters of CT may be affected on PET image. We performed the phantom study to evaluate whether the change of CT parameters(kilovolts peak and milliampere) affect standardized uptake value(SUV) on PET image. Material and Method: The data spectrum lung phantom containing diluted [18F]fluorodeoxyglucose ([18F]FDG) solution(1.909 mCi for phantom 1, $913\;{\mu}Ci$ for phantom 2) was used. The CT images of phantom were acquired with varying parameters (80, 100, 120, 140 for kVp, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 for mA). The PET images were reconstructed with the each CT images and SUVs were compared. Result : The SUVs of phantom 1 reconstructed with each 80, 100, 120 and 140 kVp showed $12.26{\pm}0.009$, $12.27{\pm}0.005$, $12.27{\pm}0.006$ and $12.27{\pm}0.009$, respectively. The SUVs of phantom 2 revealed $4.52{\pm}0.043$, $4.53{\pm}0.004$, $4.52{\pm}0.007$ and $4.52{\pm}0.005$ with elevation of voltage. There was no statistically significant difference of SUVs between groups based on various kVp. Also SUVs of phantom 1 and 2 showed no significant change with elevation of milliampere in CT parameter. Conclusion : The parameters of CT did not significantly affect SUV on PET image in our study. Therefore we can apply various parameters of CT appropriated for clinical conditions without significant change of SUV on PET CT image.

  • PDF