• 제목/요약/키워드: Lung, CT

Search Result 855, Processing Time 0.032 seconds

A Case of Cavitary Pulmonary Metastases of Primary Cavitary Lung Cancer (공동형성 원발성 폐암의 다발성 공동형성 폐전이 1예)

  • Jung, Ji-Heon;Kang, Hong-Mo;Kim, Jang-Ha;Lee, Byung-Ho;Soh, Joung-Eun;Lee, Seung-Joon;Choi, Cheon-Ung;Yoo, Jee-Hong;Sung, Dong-Wook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.3
    • /
    • pp.319-324
    • /
    • 2002
  • Many disorders and abnormalities are accompanied by cavitary lesoin of the lung and one of the most common causes of cavitary lung disease are primary and metastatic lung neoplasms. but cavitary formation of primary lung cancer is not frequent and cavitary or cystic pulmonary metastases of this is also rare. We report a case of cavitary pulmonry metastases of primary lung cancer proven by bronchoscopic biopsy and chest CT. The patients was 60 year-old heavy smoker who had no known underlying lung diseases 7 years ago and complained chronic cough. The chest CT showed primary lung cancer in right low lobe with multiple cavitary or cystic metastases in both lungs and multiple lymphatic metastases.

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.

Airway Reactivity to Bronchoconstrictor and Bronchodilator: Assessment Using Thin-Section and Volumetric Three-Dimensional CT

  • Boo-Kyung Han;Jung-Gi Im;Hak Soo Kim;Jin Mo Koo;Hong Dae Kim;Kyung Mo Yeon
    • Korean Journal of Radiology
    • /
    • v.1 no.3
    • /
    • pp.127-134
    • /
    • 2000
  • Objective: To determine the extent to which thin-section and volumetric three-dimensional CT can depict airway reactivity to bronchostimulator, and to assess the effect of different airway sizes on the degree of reactivity. Materials and Methods: In eight dogs, thin-section CT scans were obtained before and after the administration of methacholine and ventolin. Cross-sectional areas of bronchi at multiple levels, as shown by axial CT, proximal airway volume as revealed by three-dimensional imaging, and peak airway pressure were measured. The significance of airway change induced by methacholine and ventolin, expressed by percentage changes in cross-sectional area, proximal airway volume, and peak airway pressure was statistically evaluated, as was correlation between the degree of airway reactivity and the area of airways. Results: Cross-sectional areas of the bronchi decreased significantly after the administration of methacholine, and scans obtained after a delay of 5 minutes showed that normalization was insufficient. Ventolin induced a significant increase in cross-sectional areas and an increase in proximal airway volume, while the effect of methacholine on the latter was the opposite. Peak airway pressure increased after the administration of methacholine, and after a 5-minute delay its level was near that of the control state. Ventolin, however, induced no significant decrease. The degree of airway reactivity did not correlate with airway size. Conclusion: Thin-section and volumetric spiral CT with three-dimensional reconstruction can demonstrate airway reactivity to bronchostimulator. The degree of reactivity did not correlate with airway size.

  • PDF

A Case of Transient Radiographic Progression during Treatment of Pulmonary Tuberculosis: Early CT Findings (폐결핵의 치료 중에 발생한 일시적인 방사선학적 악화를 보인 1예: 초기 CT 소견)

  • Yoo, Seung Min;Lee, Hwa Yeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.4
    • /
    • pp.339-342
    • /
    • 2008
  • Early CT findings of transient radiographic progression (TRP) during treatment of active pulmonary tuberculosis including subpleural, interlobular or intralobular septal thickening and micronodules are shown in the present case. Late CT findings of TRP are subpleural, enhancing nodular infiltration with internal low attenuation. These CT features accompanied by a lack of clinical worsening in young patients taking antituberculous medication due to pulmonary tuberculosis can help to differentiate TRP from other disease entities.

Comparison and Evaluation of the Effectiveness between Respiratory Gating Method Applying The Flow Mode and Additional Gated Method in PET/CT Scanning. (PET/CT 검사에서 Flow mode를 적용한 Respiratory Gating Method 촬영과 추가 Gating 촬영의 비교 및 유용성 평가)

  • Jang, Donghoon;Kim, Kyunghun;Lee, Jinhyung;Cho, Hyunduk;Park, Sohyun;Park, Youngjae;Lee, Inwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.54-59
    • /
    • 2017
  • Purpose The present study aimed at assessing the effectiveness of the respiratory gating method used in the flow mode and additional localized respiratory-gated imaging, which differs from the step and go method. Materials and Methods Respiratory gated imaging was performed in the flow mode to twenty patients with lung cancer (10 patients with stable signals and 10 patients with unstable signals), who underwent PET/CT scanning of the torso using Biograph mCT Flow PET/CT at Bundang Seoul University Hospital from June 2016 to September 2016. Additional images of the lungs were obtained by using the respiratory gating method. SUVmax, SUVmean, and Tumor Volume ($cm^3$) of non-gating images, gating images, and additional lung gating images were found with Syngo,bia (Siemens, Germany). A paired t-test was performed with GraphPad Prism6, and changes in the width of the amplitude range were compared between the two types of gating images. Results The following results were obtained from all patients when the respiratory gating method was applied: $SUV_{max}=9.43{\pm}3.93$, $SUV_{mean}=1.77{\pm}0.89$, and $Tumor\;Volume=4.17{\pm}2.41$ for the non-gating images, $SUV_{max}=10.08{\pm}4.07$, $SUV_{mean}=1.75{\pm}0.81$, and $Tumor\;Volume=3.56{\pm}2.11$ for the gating images, and $SUV_{max}=10.86{\pm}4.36$, $SUV_{mean}=1.77{\pm}0.85$, $Tumor\;Volume=3.36{\pm}1.98$ for the additional lung gating images. No statistically significant difference in the values of $SUV_{mean}$ was found between the non-gating and gating images, and between the gating and lung gating images (P>0.05). A significant difference in the values of $SUV_{max}$ and Tumor Volume were found between the aforementioned groups (P<0.05). The width of the amplitude range was smaller for lung gating images than gating images for 12 from 20 patients (3 patients with stable signals, 9 patients with unstable signals). Conclusion In PET/CT scanning using the respiratory gating method in the flow mode, any lesion movements caused by respiration were adjusted; therefore, more accurate measurements of $SUV_{max}$, and Tumor Volume could be obtained from the gating images than the non-gating images in this study. In addition, the width of the amplitude range decreased according to the stability of respiration to a more significant degree in the additional lung gating images than the gating images. We found that gating images provide information that is more useful for diagnosis than the one provided by non-gating images. For patients with irregular signals, it may be helpful to perform localized scanning additionally if time allows.

  • PDF

TP63 Gene Polymorphisms, Cooking Oil Fume Exposure and Risk of Lung Adenocarcinoma in Chinese Non-smoking Females

  • Yin, Zhi-Hua;Cui, Zhi-Gang;Ren, Yang-Wu;Su, Meng;Ma, Rui;He, Qin-Cheng;Zhou, Bao-Sen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6519-6522
    • /
    • 2013
  • Background: Genetic polymorphisms of TP63 have been suggested to influence susceptibility to lung adenocarcinoma development in East Asian populations. This study aimed to investigate the relationship between common polymorphisms in the TP63 gene and the risk of lung adenocarcinoma, as well as interactions of the polymorphisms with environmental risk factors in Chinese non-smoking females. Methods: A case-control study of 260 cases and 318 controls was conducted. Data concerning demographic and risk factors were obtained for each subject. The genetic polymorphisms were determined by Taqman real-time PCR and statistical analyses were performed using SPSS software. Results: For 10937405, carriers of the CT genotype or at least one T allele (CT/TT) had lower risks of lung adenocarcinoma compared with the homozygous wild CC genotype in Chinese nonsmoking females (adjusted ORs were 0.68 and 0.69, 95%CIs were 0.48-0.97 and 0.50-0.97, P values were 0.033 and 0.030, respectively). Allele comparison showed that the T allele of rs10937405 was associated with a decreased risk of lung adenocarcinoma with an OR of 0.78 (95%CI=0.60-1.01, P=0.059). Our results showed that exposure to cooking oil fumes was associated with increased risk of lung adenocarcinoma in Chinese nonsmoking females (adjusted OR=1.58, 95%CI=1.11-2.25, P=0.011). However, we did not observe a significant interaction of cooking oil fumes and TP63 polymorphisms. Conclusion: TP63 polymorphism might be a genetic susceptibility factor for lung adenocarcinoma in Chinese non-smoking females, but no significant interaction was found with cooking oil fume exposure.

A Case of Epithelioid Hemangioendothelioma Involving the Lung and Liver (폐와 간을 침범한 유상피 세포성 혈관내피종 1예)

  • Lee, Seung-Keun;Choi, Seung-Hyuk;Yang, Dong-Gyoo;Park, Jae-Min;Kim, Seong-Kyoo;Lee, Won-Young;Shin, Dong-Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1396-1402
    • /
    • 1997
  • Epithelioid Hemangioendothelioma(EH) is a rare vascular tumor, originating from endothelial cells. The principal locations are lung, soft tissue, bone and liver. This tumor is of borderline malignancy, relatively benign course. In the lung, the tumor is often multifocal, bilateral and frequently lead to the mistaken diagnosis of metastatic carcinoma. Although EH of the lung is relatively slow growing tumor, extensive pulmonary involvement, systemic metastasis, mainly to the liver have been documented. A 26-year-old man with EH involving the lung and liver was reported. Chest X-ray and chest CT showed multiple nodules in both lung fields and Abdominal CT multiple round low densities in liver. Transbronchial lung biopsy was performed. The patient diagnosed as EH by light microscopic finding and immunohistochemical study for Factor VIII-related antigen.

  • PDF

The Spectrum of CT Findings of COVID-19 Pneumonia: Acute Alveolar Insult and Organizing Pneumonia as Different Phases of Lung Injury and Repair (COVID-19 폐렴의 다양한 CT 영상 소견: 급성 폐포 손상과 기질화 폐렴)

  • Yun Su Kim;Ung Rae Kang;Young Hwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.359-370
    • /
    • 2021
  • Purpose To analyze the findings and serial changes in chest CT lesions in 123 symptomatic patients with coronavirus disease 2019 (COVID-19). Materials and Methods From February 19 to April 7, 2020, a total of 123 confirmed COVID-19 patients (male, 44; female, 79; mean age, 59.2 ± 18.6) were enrolled in this retrospective study. A total of 234 CT scans were reviewed for the following patterns: acute alveolar insult (AAI) patterns: ground-glass opacity (GGO), crazy-paving appearance, mixed pattern, and consolidation; organizing pneumonia (OP) patterns: perilobular patterns, band opacity, curvilinear opacity, reversed halo opacity, and small nodular consolidation; resolving patterns: pure GGO, remnant curvilinear, small nodular consolidation, and serial changes of lung abnormalities. We compared the proportions of AAI pattern, OP pattern, or resolving pattern with time progression and analyzed the association between the patterns and disease severity using Pearson chi-square and Fisher's exact test. Results Predominant CT patterns were AAI pattern (87%) in the early hospital period group (0-10 days, after the onset of symptoms), OP pattern (45.7%) in the later hospital period group (after 10 days), and resolving pattern in discharge and follow-up group (47.2% and 84.8%, respectively). The difference in the proportions of predominant CT patterns with time progression was statistically significant (p < 0.001, Pearson's chi-square test). No statistically significant association was observed between the patterns and disease severity (p = 0.055, Fisher's exact test). No fibrous changes in the lesions were observed on follow-up CT scans. Conclusion The serial CT scans of COVID-19 patients showed the spectrum of COVID pneumonia CT manifestations as different phases of lung injury and repair.

Feature-based Non-rigid Registration between Pre- and Post-Contrast Lung CT Images (조영 전후의 폐 CT 영상 정합을 위한 특징 기반의 비강체 정합 기법)

  • Lee, Hyun-Joon;Hong, Young-Taek;Shim, Hack-Joon;Kwon, Dong-Jin;Yun, Il-Dong;Lee, Sang-Uk;Kim, Nam-Kug;Seo, Joon-Beom
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.237-244
    • /
    • 2011
  • In this paper, a feature-based registration technique is proposed for pre-contrast and post-contrast lung CT images. It utilizes three dimensional(3-D) features with their descriptors and estimates feature correspondences by nearest neighborhood matching in the feature space. We design a transformation model between the input image pairs using a free form deformation(FFD) which is based on B-splines. Registration is achieved by minimizing an energy function incorporating the smoothness of FFD and the correspondence information through a non-linear gradient conjugate method. To deal with outliers in feature matching, our energy model integrates a robust estimator which discards outliers effectively by iteratively reducing a radius of confidence in the minimization process. Performance evaluation was carried out in terms of accuracy and efficiency using seven pairs of lung CT images of clinical practice. For a quantitative assessment, a radiologist specialized in thorax manually placed landmarks on each CT image pair. In comparative evaluation to a conventional feature-based registration method, our algorithm showed improved performances in both accuracy and efficiency.