This study aimed to verify the hypothesis that urea denatures hemoglobin in the blood, thereby exposing active sites of enzymes and enhancing the chemiluminescence of the blood-luminol reaction. When blood was pretreated with urea, higher concentrations of pretreatment urea or longer pretreatment times resulted in enhanced chemiluminescence in the blood-luminol reaction, supporting the above hypothesis. However, the chemiluminescence was enhanced when blood was treated with luminol mixed with an 8 M urea solution, although the fact that the time for urea to denature hemoglobin was shorter compared to when blood was pretreated with urea and followed by luminol. In addition, the chemiluminescence was enhanced when a transition metal without hemoglobin was reacted with urea-containing luminol. Based on these results, it is anticipated that urea not only denatures hemoglobin but also plays a role in the luminol-hydrogen peroxide reaction.
Seulgi, Jang;Minkyoung, Kim;Heejin, Kim;Munhee, Lee;Sungwook, Hong
Analytical Science and Technology
/
v.35
no.6
/
pp.242-248
/
2022
The effect of ethylenediamine (EDA) on the reaction of luminol or Bluestar with blood and bleaches was studied. For this purpose, blood, chlorine bleach, and oxygen bleach were applied to filter paper, treated with EDA-containing luminol or Bluestar, and the changes in chemiluminescence intensity were observed. It was found that the chemiluminescence intensity of the luminol (or Bluestar)-blood reaction did not change with the increasing concentration of EDA. However, the chemiluminescence intensity of the luminol (or Bluestar)-chlorine bleach reaction decreased and the chemiluminescence intensity of the luminol (or Bluestar)-oxygen bleach reaction increased, with increasing EDA concentration. Thus, it was found that when EDA was added to luminol (or Bluestar), which is a blood-sensitive reagent, EDA suppressed the false-positive reaction induced by chlorine bleach and induced a false-positive reaction with oxygen bleach. Consequently, the addition of EDA is not recommended for enhancing bloodstains with luminol or Bluestar.
Kim, Hyung-Il;Kang, Chul-Goo;Kang, Moon-Sik;Park, Jung-Ho;Min, Nam-Ki
Proceedings of the KIEE Conference
/
2002.07c
/
pp.1552-1554
/
2002
본 논문에서는 실리콘을 기초로 한 포토다이오드를 제작하여 현재 바이오센서에서 이용되고 있는 luminol 화학 발광을 전기적으로 검출하였다. 우선, 실리콘 웨이퍼에 이온주입을 통해 p-n 접합을 형성하고 Al 전극을 형성시켜 포토다이오드를 제작하였다. PDMS을 passivation 막으로 사용하여 horseradish peroxidase(HRP) 농도 변화에 따른 발광의 최적조건과 luminol, HRP가 섞인 용액에 서로 다른 양의 과산화수소를 넣어 발광이 최대로 발생하는 혼합비를 측정하였다. 최종적으로 2mM luminol, 25U HRP 조건 하에서 과산화수소 농도에 따른 화학 발광을 측정하였으며, $10{\mu}M$부터 $500{\mu}M$ 범위의 과산화수소 농도 변화에 따른 포토다이오드의 감도는 단위 면적당 23.429pA/ ${\mu}M$이다.
Lim, Seung;Kim, Jung-mok;Jung, Ju Yeon;Lim, Si-Keun
Analytical Science and Technology
/
v.31
no.1
/
pp.47-56
/
2018
Finding the blood left at a crime scene is very important to reconstruct or solve a criminal case. Although numerous reagents have been developed for use at crime scenes, luminol is the most representative. Bluestar Forensic has been used in recent years, but is expensive and cannot be stored after preparation. This study aims to develop a new luminol reagent that can be stored for a long period of time while maintaining the chemiluminescence intensity at the level of Bluestar Forensic. Because luminol dissolves well in aqueous alkaline solutions, the use of sodium hydroxide in the preparation of luminol reagents can promote the decomposition of hydrogen peroxide. Magnesium sulfate, sodium silicate, and potassium triphosphate have been used as hydrogen peroxide stabilizers. The effects of the addition of these substances on the chemiluminescence emission intensity and the storage period of the luminol reagents were confirmed. The addition of a hydrogen peroxide stabilizer was shown to have no significant affect on the chemiluminescence emissions intensity or stabilized pH of the luminol reagent during storage. It also greatly increases the shelf life of the reagents. The use of magnesium sulfate as a hydrogen peroxide stabilizer is the most appropriate. When sodium perborate is used instead of hydrogen peroxide as an oxidizing agent, there is no significant change in the sensitivity and chemiluminescence emissions intensity, but the storage period is shortened. However, after the reaction with blood, the pH of the mixed solution does not increase significantly, and is judged to be more suitable than a reagent made of hydrogen peroxide.
We constructed and tested an airborne peroxyacetyl nitrate (PAN) monitoring system based on luminol chemiluminescence detection with fast gas chromatography. This system allowed for simultaneous measurement of PAN and nitrogen dioxide ($NO_2$) with a time resolution of <2 min. Actual sample masses within the fixed volume sample loop at various altitudes and temperatures were adjusted to standard atmosphere, using measured pressures and temperatures. The airborne PAN measurement system was evaluated during two field studies above the southern Korean Peninsula in August and October 2009. The detection limit based on the ISO approach was 0.035 ppbv PAN, well below the observed concentrations of 0.185-1.49 ppbv during these studies. Under these conditions, the PAN mixing ratios were positively correlated with $O_x$ ($O_x=O_3+NO_2$), with slopes varying between 0.014 and 0.033 and intercepts between 22.6 and 55.1 ppbv $O_x$. The intercepts corresponded roughly to background $O_x$ mixing ratios in central Europe; however, the slopes were above the range of slopes reported in other studies. We also enhanced the durability, safety, and ease of maintenance of the PAN monitoring system by redesigning the structure of the conventional luminol cell.
Commercial one-step rapid fecal occult blood (FOB) kit which was used as a screening test to detect traces of blood in stool samples was evaluated for the feasibility of the forensic identification of human blood. The sensitivity was determined and compared with the conventional Leucomalichite green (LMG) method. In addition, the specificity of the kit and the effects of various chemicals and environmental factors were examined. FOB kit was specific for human hemoglobin and more sensitive than LMG test (approximately 100 times). FOB kit showed positive band using at least 1,000,000-fold diluted human blood. The antigen was very stable regardless of storage temperature and boiling. The positive reaction was not affected by LMG and Luminol, the traditional tests for identification of bloodstain. As a results, FOB test kit could be effectively applied to identification of human blood at crime scene and crime laboratories.
Kim, Kyung-Min;Jang, Taek-Gyun;Kim, Young-Ho;Oh, Sang-Huyb;Lee, Sang-Hak
Analytical Science and Technology
/
v.24
no.4
/
pp.243-248
/
2011
A selective determination method of mercury (II) ion in aqueous solution by luminol-based chemiluminescence system (luminol CL system) has been developed. Determination of metal ions such as copper (II), iron (III), chromium (III) ion in solution by the luminol CL system using its catalytic role in the reaction of luminol and hydrogen peroxide has been reported by several groups. In this study, the catalytic activity of mercury (II) ion in the reaction of luminol and hydrogen peroxide was observed by the enhanced CL intensity of the luminol CL system. Based on this phenomenon, experimental conditions of the luminol CL system were investigated and optimized to determine mercury (II) ion in aqueous solution. While mercury (II) ion in mixed sample solution containing mercury (I) and (II) ions highly enhanced the CL intensity of the luminol CL system, the mercury (I) ion could not enhanced the CL intensity. Thus selective determination of the mercury (II) ions in a mixture containing mercury (I) and (II) ions could be achieved. Each concentration of mercury (I) and (II) ions in aqueous solution can be obtained from the results of the CL method that give the concentration of only mercury (II) ion and the inductively coupled plasma (ICP) method that give the total concentration of mercury ions. On the optimized conditions, the calibration curve of mercury (II) ion was linear over the range from $1.25{\times}10^{-5}$ to $2.50{\times}10^{-3}M$ with correlation coefficient of 0.991. The detection limit of mercury (II) ion in aqueous solution was calculated to be $1.25{\times}10^{-7}M$.
Proceedings of the Korea Air Pollution Research Association Conference
/
2002.11a
/
pp.121-122
/
2002
PAN (Peroxyacetyl Nitrate)은 오존과 함께 대도시 광화학오염의 주요 원인물질로 알려져 있고 대기 중 NOx와 VOCs가 PAN의 생성에 복잡한 반응 경로를 통해 영향을 줄 뿐 만 아니라 원거리 이동을 통하여 비교적 청정지역에 주요한 NOx 공급원으로 알려져 있다. 하지만 PAN은 대기 중 농도가 작고 비교적 낮은 온도에서도 쉽게 열분해 되기 때문에 관측이 어려운 물질이다. (중략)
Proceedings of the Korea Air Pollution Research Association Conference
/
2003.11a
/
pp.173-174
/
2003
PAN은 1950년 중반 스모그 챔버연구원에서 'Compound X'라고 규정된 광화학 2차 오염물질로 강한 햇빛, NMHCs과 NOx의 존재하에서 이들 반응에 의해 형성된 물질이다 (Stephen, 1969) PAN은 눈을 자극하고, 식물에 대해 독성을 나타내며, 변이성과 발암을 유발할 가능성도 가지고 있다. 또한 PAN은 열적으로 불안정하여 상온에서 쉽게 NO2와 Peroxyaceyl radical로 분해 되며, 저온에서는 안정되게 존재하여 특히 상층 대류권을 통한NO2의 장거리 수송과 NO2의 reservoir역할을 한다. (중략)
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.