• 제목/요약/키워드: Lumen-apposing metal stent

검색결과 3건 처리시간 0.014초

No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis

  • Shyam Vedantam;Rahil Shah;Sean Bhalla;Shria Kumar;Sunil Amin
    • Clinical Endoscopy
    • /
    • 제56권3호
    • /
    • pp.298-307
    • /
    • 2023
  • Background/Aims: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. Methods: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed. Results: Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%-95.2%) and 92.1% (95% CI, 68.4%-98.4%), clinical success rates of 88.6% (95% CI, 85.4%-91.1%) and 89.6% (95% CI, 79.0%-95.1%), adverse event rates of 11.4% (95% CI, 8.1%-15.9%) and 14.7% (95% CI, 4.4%-39.1%), and reintervention rates of 10.3% (95% CI, 6.7%-15.4%) and 3.5% (95% CI, 1.6%-7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40-9.18; p=0.008). Conclusions: No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent.

Endoscopic ultrasound-guided gastrojejunostomy with a direct technique without previous intestinal filling using a tubular fully covered self-expandable metallic stent

  • Hakan Senturk;Ibrahim Hakki Koker;Koray Kochan;Sercan Kiremitci;Gulseren Seven;Ali Tuzun Ince
    • Clinical Endoscopy
    • /
    • 제57권2호
    • /
    • pp.209-216
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasonography-guided gastrojejunostomy is a minimally invasive method for the management of gastric outlet obstruction. Conventionally, a lumen-apposing metal stent (LAMS) is used to create an anastomosis. However, LAMS is expensive and not widely available. In this report, we described a tubular fully covered self-expandable metallic stent (T-FCSEMS) for this purpose. Methods: Twenty-one patients (15 men [71.4%]; median age, 66 years; range, 40-87 years) were included in this study. A total of 19 malignant (12 pancreatic, 6 gastric, and 1 metastatic rectal cancer) and 2 benign cases were observed. The proximal jejunum was punctured with a 19 G needle. The stomach and jejunum walls were dilated with a 6 F cystotome, and a 20×80 mm polytetrafluoroethylene T-FCSEMS (Hilzo) was deployed. Oral feeding was initiated after 12 to 18 hours and solid foods after 48 hours. Results: The median procedure time was 33 minutes (range, 23-55 minutes). After two weeks, 19 patients tolerated oral feeding. In patients with malignancy, the median survival time was 118 days (range, 41-194 days). No serious complications or deaths occurred. All patients with malignancy tolerated oral food intake until they expired. Conclusions: T-FCSEMS is safe and effective. This stent should be considered as an alternative to LAMS for gastric outlet obstruction.