• 제목/요약/키워드: Lumen apposing metal stents

검색결과 3건 처리시간 0.018초

No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis

  • Shyam Vedantam;Rahil Shah;Sean Bhalla;Shria Kumar;Sunil Amin
    • Clinical Endoscopy
    • /
    • 제56권3호
    • /
    • pp.298-307
    • /
    • 2023
  • Background/Aims: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. Methods: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed. Results: Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%-95.2%) and 92.1% (95% CI, 68.4%-98.4%), clinical success rates of 88.6% (95% CI, 85.4%-91.1%) and 89.6% (95% CI, 79.0%-95.1%), adverse event rates of 11.4% (95% CI, 8.1%-15.9%) and 14.7% (95% CI, 4.4%-39.1%), and reintervention rates of 10.3% (95% CI, 6.7%-15.4%) and 3.5% (95% CI, 1.6%-7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40-9.18; p=0.008). Conclusions: No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent.

A remnant choledochal cyst after choledochal cyst excision treated with a lumen-apposing metal stent: a case report

  • Bo Kyung Kim;Jung Won Chun;Sang Hyub Lee;Ji Kon Ryu;Yong-Tae Kim;Woo Hyun Paik
    • Clinical Endoscopy
    • /
    • 제55권4호
    • /
    • pp.564-569
    • /
    • 2022
  • A lumen-apposing metal stent (LAMS) is a saddle-shaped stent with large flanges at both ends, thereby preventing stent migration and helping with approximation of the adjacent structures. We report the case of a 25-year-old female with remnant choledochal cyst which was successfully treated with LAMS after initial treatment failure with a plastic stent. Although complete excision of the cyst is the definite treatment of choledochal cysts, endoscopic ultrasonography-guided cystoduodenostomy can be considered in cases wherein surgery is not feasible and dysplasia is not present. LAMS may be preferred to plastic stents for effective resolution of remnant choledochal cyst and prevention of ascending infection.

Initial United Kingdom experience of endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography

  • Puneet Chhabra;Wei On;Bharat Paranandi;Matthew T. Huggett;Naomi Robson;Mark Wright;Ben Maher;Nadeem Tehami
    • 한국간담췌외과학회지
    • /
    • 제26권4호
    • /
    • pp.318-324
    • /
    • 2022
  • Backgrounds/Aims: Gallstone disease is a recognized complication of bariatric surgery. Subsequent management of choledocholithiasis may be challenging due to altered anatomy which may include Roux-en-Y gastric bypass (RYGB). We conducted a retrospective service evaluation study to assess the safety and efficacy of endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) in patients with RYGB anatomy. Methods: All the patients who underwent EDGE for endoscopic retrograde cholangiopancreatography after RYGB at two tertiary care centers in the United Kingdom between January 2020 and October 2021 were included in the study. Clinical and demographic details were recorded for all patients. The primary outcome measures were technical and clinical success. Adverse events were recorded. Hot Axios lumen apposing metal stents measuring 20 mm in diameter and 10 mm in length were used in all the patients for creation of a gastro-gastric or gastro-jejunal fistula. Results: A total of 14 patients underwent EDGE during the study period. The majority of the patients were female (85.7%) and the mean age of patients was 65.8 ± 9.8 years. Technical success was achieved in all but one patient at the first attempt (92.8%) and clinical success was achieved in 100% of the patients. Complications arose in 3 patients with 1 patient experiencing persistent fistula and weight gain. Conclusions: In patients with RYGB anatomy, EDGE facilitated biliary access has a high rate of clinical success with an acceptable safety profile. Adverse events are uncommon and can be managed endoscopically.