Treatment of Benign Bone Tumor with Xenograft (이종골 이식을 이용한 양성 골 종양 치료)

  • Kim, Han-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.2
    • /
    • pp.189-193
    • /
    • 1995
  • The authors reviewed 49 cases(48 patients) of benign bone tumor who had surgical treatment with xenograft at department of orthopedic surgery, Seoul National University Hospital from May, 1980 to May, 1994. Materials consist of 21 males and 27 females. The mean age at operation was 20.1 years(range : 4 -55 years) and the mean follow up period was 25.4 months(range : 7 - 85 months). We did xenograft only in 34 cases and xenograft mixed with autograft in 15 cases(14 cases, from ilium, 1 case from femur). The used materials for xenograft were $Lubboc^{(R)}$ in 29 cases, $Surgibone^{(R)}$ in 17 cases and $Pyrost^{(R)}$ in 3 cases. The average durations when bony union was achieved in radiograph were 13.8 weeks in whole cases, 12.5 weeks(range : 8 - 24 weeks) in $Lubboc^{(R)}$ graft cases and 15.7 weeks(range : 6 - 24 weeks) in $Surgibone^{(R)}$ graft cases. The tumor recurred in 4 cases, 1 case was recurred giant cell tumor at distal femur treated with mixed auto and $Lubboc^{(R)}$ graft and 2 cases were large cystic lesions at the proximal humerus diagnosed as simple bone cyst and at distal tibia diagnosed as fibrous dysplasia treated with $Surgibone^{(R)}$ graft and 1 case was aneurysmal bone cyst of the proximal tibia treated with $Lubboc^{(R)}$ graft. Wound infection occurred in 1 case. More transfusion was done in the cases that the lesion was larger than 5cm, the lesions were in the ilium or femur and the cases that were treated with mixed with autograft. This study implies that benign bone tumor is successfully treqated with curettage and xenograft or xenograft mixed with autograft. And also this method will reduce morbidity of donor site, intraoperative bleeding and post-transfusion complications.

  • PDF

Clinical Experience of Anterior Cervical Interbody Fusion with the PCB System (전방 경추 유합술에서의 PCB System의 임상적 경험)

  • Kim, Sung Han;Kim, Ho Jin;Kang, Jae Kyu;Doh, Jong Oung;Lee, Chun Dae
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1170-1176
    • /
    • 2001
  • Objective : The purpose of the study was to evaluate the clinical and radiological results after discectomy and Lubboc bone graft in the surgical management of the cervical diseases with a new titanium interbody implant and integrated screw fixation(PCB) by anterior approach. Methods : The authors retrospectively analyzed 28 cases of anterior cervical fusion with PCB system and Lubboc bone(xeno graft) from september 1998 to december 2000. Twenty-eight patients with cervical diseases underwent decompression cervical lesion and followed from 5 to 27 months with a mean follow-up of 14 months. There patients were evaluated with clinically and radiologically at immediate postoperative period and at 3, 6, 9, and 12 months. Result : The authors investigated the pre- and postoperative intervertebral disc space, clinical outcomes, radiography fusion rate, and Cobb angle in the fixed segments by anterior approach. The lordotic angles and height of disc space were increased after the operation. The clinical outcome of patients follow-up was good or excellent result based on Odom's criteria with improvement of clinical symptom in about 92.9% of the cervical diseases. Two patients showed loosening of the lower and upper cervical screw of PCB instruments, and two patients showed swallowing difficulty and wound infection Conclusion : The PCB system is a new implant for anterior cervical interbody fusion in the degenerative cervical disease and disc herniations. It provides immediate stability and segment distraction. The results of this study indicate that the PCB system is safe, easy handling of hardware, less complications, high fusion rate, and has provide the keeping the intervertebral disc space height and lordotic angles.

  • PDF

8 Years Follow-up of Complications after Maxillary Cyst Enucleation with Xenograft: Case Report (상악골낭종 적출술 후 이식된 이종골지지체의 술 후 8년 감염 증례)

  • Lee, Eun-Young;Kim, Kyoung-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.5
    • /
    • pp.425-429
    • /
    • 2011
  • Bone grafts are becoming increasingly common in oral and maxillofacial surgery to improve bone healing procedures. Bovine bone as a xenograft is a representative osteoconductor and space filler; however, sometimes complications, such as infection and wound dehiscence are encountered with its use. We report the result of an eight-year follow-up of a xenograft case and processing methods of inorganic bovine bone along with a review of the literature. Xenograft ($LUBBOC^{(R)}$) was used in a cyst enucleation site of the maxilla, as a bone substitute and space filler. Inflammation and infection were defined several times as lack of osseous contact between the graft and host bone, caused by remodeling failure over an eight-year period. Pathologic findings of the xenograft revealed dead bony trabeculae with inflamed fibrous tissue and actinomycosis.

PCB Instrumentation with Lubboe Bone in Anterior Cervical Interbody Fusion (PCB 기구와 이종골을 이용한 경추체간 전방 유합술)

  • Park, Jeong Hyun;Oh, Seong Hoon;Yi, Hyeong Joong;Kim, Ju Heon;Kim, Young Soo;Ko, Yong;Kim, Kwang Myung;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1284-1290
    • /
    • 2001
  • Objective : PCB cervical instrument is a newly introduced fusion device which comprises cervical plate, cage (spacer) and screw system. It is developed to enhance fusion rate and stability, as well as to reduce complications related to hardware failure. We investigated the efficacy of clinical and radiological results of PCB instrument and Lubboc bone. Methods : From August, 1998 to October, 1999, authors performed 54 cases of anterior cervical interbody fusion with PCB instrument and Lubboc bone. Retrospective analysis was undertaken based on clinical and radiological findings. Clinical improvement was evaluated according to Odom's criteria. Cervical plain films and tomography were taken every 2 months to evaluate the degree of interbody fusion and disc height changes. Results : Bone fusion was observed in 36 cases(90%) over 6 months after operation, and during which time there was no significant interval change. There were 3 cases of hardware dislodgement. Disc height was increased significantly and preserved in all cases. Clinical outcome over good degree was seen more than 94% of patients. Conclusion : Longer follow-up period and comparative studies to similar instrument appear to be necessary, but this instrumentation system has shown high fusion rate and fewer adverse effects in our series. We believe this system might be indicated for the treatment of cervical trauma and degenerative disease in selective cases.

  • PDF

Percutaneous Autologous Marrow and Heterograft Bone Grafting in a Treatment for Simple Bone Cyst (경피적 자가 골수 및 이종골 이식을 이용한 고립성 골낭종의 치료)

  • Lee, Keun-Bae;Rowe, Sung-Man;Yoon, Taek-Rim;Son, Il-Jin;Jung, Sung-Taek
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.24-30
    • /
    • 2003
  • Purpose: To clarify the results of simple bone cyst (SBC) treatment in children by percutaneous autologous bone marrow grafting and xenografting. Materials and Methods: We studied seven cases (4 males, 3 females) of SBC, which were treated by percutaneous autologous marrow and heterograft bone grafting from January 1996 to February 1999. Their mean age at surgery was 10 years (6 to 15), and the mean follow-up period was 35.6 months (20 to 52). Three cases were located in the proximal and middle humerus; three cases were in the proximal femur; and one case occurred in the ilium. Mean volume was 14.7 $cm^2$ (10 to 23). Six cases were active, and one was inactive. Five patients had a history of receiving a mean of 3.2 steroid injections. The mean quantity of bone marrow used in treatment was 14.3 ml (10 to 20), and the mean amount of $Lubboc^{(R)}$ heterograft bone (Transphyto S.A. Clermont Ferrand, France) used was 6.4 blocks (5 to 10). Results were analyzed using the modified Neer classification. Results: Five cases completely healed with obliteration of the cyst cavity (Grade IV). Two cases demonstrated sclerosis around a partially visible cyst (Grade III). All treatment results were satisfactory and without intraoperative or postoperative complications. Conclusione: Percutaneous autologous marrow and heterograft bone grafting is recommended as an effective treatment method for simple bone cyst. It offers ease of operative technique, a high rate of healing, a low recurrence rate, low morbidity, a low incidence of postoperative complications, and free from bone graft donor site problems.

  • PDF