• Title/Summary/Keyword: Lower polished surface

Search Result 47, Processing Time 0.049 seconds

Comparison of surface topography and roughness in different yttrium oxide compositions of dental zirconia after grinding and polishing

  • Shin, Hyun-Sub;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.258-267
    • /
    • 2021
  • PURPOSE. The purpose of this study was to compare the surface roughness, phase transformation, and surface topography of dental zirconia with three different yttrium oxide compositions under same grinding and polishing conditions. MATERIALS AND METHODS. Three zirconia disks (IPS e.max ZirCAD LT, MT, MT multi, Ivoclar Vivadent AG, Schaan, Liechtenstein) were selected for experimental materials. Sixty-nine bar-shaped specimens were fabricated as 12.0 × 6.0 × 4.0 mm using a milling machine and glazing was conducted on 12.0 × 6.0 mm surface by same operator. With a custom polishing device, 12.0 × 6.0 mm surfaces were polished under same condition. Surface roughness (Ra[㎛]) was measured before grinding (C), after grinding (G), and at every 3 steps of polishing (P1, P2, P3). X-ray diffraction and FE-SEM observation was conducted before grinding, after grinding, and after fine polishing (P3). Statistical analysis of surface roughness was performed using Kruskal-Wallis test and Mann-Whitney-U test was used as a post hoc test (α = .05). RESULTS. There were no significant differences of surface roughness between LT, MT, and MM groups. In LT, MT, and MM groups, P3 groups showed significantly lower surface roughness than C groups. X-ray diffraction showed grinding and polishing didn't lead to phase transformation on zirconia surface. In FE-SEM images, growths in grain size of zirconia were observed as yttrium oxide composition increases. CONCLUSION. Polished zirconia surface showed clinically acceptable surface roughness, but difference in yttrium oxide composition had no significant influence on the surface roughness. Therefore, in clinical situation, zirconia polishing burs could be used regardless of yttrium oxide composition.

DENTINAL MICROLEAKAGE STUDY ON THE LIGHT CURABLE RESTORATIVE GLASS IONOMER CEMENT (광중합형 충전용 글라스 아이오노머 시멘트의 상아질 변연누출에 관한 정량분석)

  • Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.832-838
    • /
    • 1995
  • The purpose of this study was to evaluate the amount of marginal microleakage of 2 light curable GI cements(Fuji II LC & VariGlass), which contain some resin components. 4 volunteers kept on acrylic resin plates, which contained dentin disks with cavities filled with test materials for 2 weeks. The time when polishing was done(5 minutes and 24 hours after filling) and the use of protective agents were varied, so 8 groups with each 6 specimens were tested. After having specimens(disks with cavities filled with materials) penetrated with 1% Methylene Blue solution, specimens were stored in 40% nitric acid solution for 4 days to extract adsorbed dye material. Supernatants of centrifuged samples were diluted 5 times and Spectrophotometer was used to determine the degree of absorption. Dye concentration was calculated through the pre-obtained Linear Regression Curve. The results were as follows. 1. The best result was seen in groups (PF24, PV24) which were protected and polished 24 hours later and the opposite phenomenon was seen in groups(NF24, NV24) which were held without protection and polished 24 hours later. Groups polished S minutes later showed moderate leakage pattern. 2. Groups polished 5 minutes later showed similar leakage amount irrespective of using of protective agent. But statistically insignificant lower values were seen in VariGlass than in Fuji II LC groups, So It was considered that VariGlass may be more resistant to early moisture attack than Fuji II LC. 3. In groups polished 24 hours later, there was no significant difference between materials but was definitely significant difference according to the use of protective agent. If the cement in which polishing will be done 24 hours later, Protective agent should be used to cover the surface.

  • PDF

A STUDY ON THE REMOVAL TORQUE OF TITANIUM IMPLANTS (Titanium Implant의 Removal Torque에 관한 연구)

  • Lee, June-Seok;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.148-169
    • /
    • 1994
  • The concept of biologic attachment of load-bearing implants has developed over the past decades as an alternative to the difficulties associated with long term implantation using mechanical fixation and bone cement. The choice of implant material is also as critical an element as site preparation or insertion procedure. The properties of implants that affect host tissue responses are not limited to chemical composition alone, but also include shape, surface characteristics, site of implantation, and mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium. This experiment will give insight into important factors that must be considered when interpreting in vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated the significance of different surface textures by comparison of the withdrawal forces necessary for removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial response on the light microscopic level to implant surface. And the priority of the area of insertion on osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months later Kanon Torque Gauge was used to unscrew the implants. The results were as follows : 1. No significant difference was seen in the removal torque due to variation in surface treatment, 23 Ncm for the sandblasted and 23.33 Ncm for the polished surface (p>0.05). 2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in comparison to ones in the posterior (18 Ncm) region (p<0.05). 3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p>0.05).

  • PDF

Initial bacterial adhesion on resin, titanium and zirconia in vitro

  • Lee, Byung-Chul;Jung, Gil-Yong;Kim, Dae-Joon;Han, Jung-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.81-84
    • /
    • 2011
  • PURPOSE. The aim of this in vitro study was to investigate the adhesion of initial colonizer, Streptococcus sanguis, on resin, titanium and zirconia under the same surface polishing condition. MATERIALS AND METHODS. Specimens were prepared from Z-250, cp-Ti and 3Y-TZP and polished with $1 {\mu}m$ diamond paste. After coating with saliva, each specimen was incubated with Streptococcus sanguis. Scanning electron microscope, crystal violet staining and measurement of fluorescence intensity resulting from resazurin reduction were performed for quantifying the bacterial adhesion. RESULTS. Surface of resin composite was significantly rougher than that of titanium and zirconia, although all tested specimens are classified as smooth. The resin specimens showed lower value of contact angle compared with titanium and zirconia specimens, and had hydrophilic surfaces. The result of scanning electron microscopy demonstrated that bound bacteria were more abundant on resin in comparison with titanium and zirconia. When total biofilm mass determined by crystal violet, absorbance value of resin was significantly higher than that of titanium or zirconia. The result of relative fluorescence intensities also demonstrated that the highest fluorescence intensity was found on the surface of resin. Absorbance value and fluorescence intensity on titanium was not significantly different from those on zirconia. CONCLUSION. Resin specimens showed the roughest surface and have a significantly higher susceptibility to adhere Streptococcus sanguis than titanium and zirconia when surfaces of each specimen were polished under same condition. There was no significant difference in bacteria adhesion between titanium and zirconia in vitro.

Biocompatibility study of lithium disilicate and zirconium oxide ceramics for esthetic dental abutments

  • Brunot-Gohin, Celine;Duval, Jean-Luc;Verbeke, Sandra;Belanger, Kayla;Pezron, Isabelle;Kugel, Gerard;Laurent-Maquin, Dominique;Gangloff, Sophie;Egles, Christophe
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.6
    • /
    • pp.362-371
    • /
    • 2016
  • Purpose: The increasing demand for esthetically pleasing results has contributed to the use of ceramics for dental implant abutments. The aim of this study was to compare the biological response of epithelial tissue cultivated on lithium disilicate ($LS_2$) and zirconium oxide ($ZrO_2$) ceramics. Understanding the relevant physicochemical and mechanical properties of these ceramics will help identify the optimal material for facilitating gingival wound closure. Methods: Both biomaterials were prepared with 2 different surface treatments: raw and polished. Their physicochemical characteristics were analyzed by contact angle measurements, scanning white-light interferometry, and scanning electron microscopy. An organotypic culture was then performed using a chicken epithelium model to simulate peri-implant soft tissue. We measured the contact angle, hydrophobicity, and roughness of the materials as well as the tissue behavior at their surfaces (cell migration and cell adhesion). Results: The best cell migration was observed on $ZrO_2$ ceramic. Cell adhesion was also drastically lower on the polished $ZrO_2$ ceramic than on both the raw and polished $LS_2$. Evaluating various surface topographies of $LS_2$ showed that increasing surface roughness improved cell adhesion, leading to an increase of up to 13%. Conclusions: Our results demonstrate that a biomaterial, here $LS_2$, can be modified using simple surface changes in order to finely modulate soft tissue adhesion. Strong adhesion at the abutment associated with weak migration assists in gingival wound healing. On the same material, polishing can reduce cell adhesion without drastically modifying cell migration. A comparison of $LS_2$ and $ZrO_2$ ceramic showed that $LS_2$ was more conducive to creating varying tissue reactions. Our results can help dental surgeons to choose, especially for esthetic implant abutments, the most appropriate biomaterial as well as the most appropriate surface treatment to use in accordance with specific clinical dental applications.

Effect of surface roughness onto the scattering in low loss mirrors (기판의 표면거칠기와 반사경 산란에 대한 연구)

  • 조현주;신명진;이재철
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.3
    • /
    • pp.209-214
    • /
    • 2002
  • The effect of surface roughness on mirror scattering has been studied. Five kinds of substrates with different surface roughness were fabricated. On those substrates, a dielectric multi-layer coating with high reflectivity was deposited by ion beam sputtering and electron beam evaporation. A total integrated scattering measurement set-up was built for the evaluation of deposited samples. Most of the ion beam sputtered mirrors showed lower scattering than the electron beam evaporated one, which deposited on substrates similar in surface roughness. Over ~2 $\AA$ in surface roughness, scattering strongly depend on the micro-structure of the super-polished surface. The lowest scattering we have achieved is 2.06 ppm by ion beam sputtering from the substrate with surface roughness of 0.23 $\AA$.

AN ELECTROCHEMICAL STUDY ON SURFACE FINISH OF DENTAL AMALGAM (아말감의 표면연마에 관한 전기화학적 연구)

  • Suk, Chang-In;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.18-32
    • /
    • 1991
  • The purpose of this study was to observe characteristic properties of amalgam through the polarization curves and SEM images from 4 type amalgams (Amalcap, Shofu spherical. Dispersalloy and Tytin) with 3 different surface finish procedures (polishing, burnishing and carving) by using the potentiostats (EG & GPARC) and SEM (Jeol JSM-35). After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of mechanical amalgamator (Samki), the triturated mass was inserted into the cylndrical metal mold which was 12 mm in diameter and 10 mm in height and was pressed with $100kg/cm^2$. 4 specimens of each type amalgam were burnished with egg burnisher and another 4 specimens of each type amalgam were carved with Hollenback carver. Above 8 specimens and remaining untreated 4 specimens were stored at room temperature for about 7 days. Untreated 4 specimens of each type amalgam were polished with abrasive papers (Deer) from #400 to #1200 and finally on the polishing cloth with $0.5{\mu}m$ and $0.06{\mu}m$ $Al_2O_3 $ powder suspended water. Anodic polarization measurements was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution at $37^{\circ}C$. The open circuit potential was determined after 30 minutes immersion of specimen in electrolyte. The scan rate was 1 mV/sec and the surface area of amalgam exposed to the solution was $0.64cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). SEM images of each specimen were taken after + 800 mV (SCE) polarization. The results were as follows: 1. The corrosion potential of high copper amalgam was more anodic than that of low copper amalgam. 2. The polished amalgam were more resistant to corrosion than any other burnished and carved amalgam. 3. In the case of polishing, current density of high copper amalgam was lower than that of low copper amalgam.

  • PDF

AN EXPERIMENTAL STUDY ON PENETRATION OF DYE IN COMPOSITE RESIN (수종(數種) Composite Resin의 색소침투(色素浸透)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Lee, Myung-Chong
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.155-163
    • /
    • 1986
  • The purpose of this study was to measure penetration of dye stuff (2% Methylene blue, 2% Hematoxylin, 2% crystal violet and 2% safranin-O) on unfilled resin (Lang Dental MFG Co.) Hipol (Boopyung Dental Chemical Co. Macrocomposite resin) Durafill (Kulzer, Co. Microfilled Composite resin) and Heliosit (Vivadent Co. Microfilled Composite resin) The unfilled resin with dough stage was inserted into plastic tuble (5mm in diameter and 4mm in height) with condensation force of 1000 gr, 2000 gr and without condensation force. Hipol mixed on the mixed pad was inserted into the plastic tube by the same method as the unfilled resin. The microfilled resins which were Durafill and Heliosit were polymerized for 60 seconds with the visible light on each surface of the plastic tube which was upper and lower, under condensation force of 1000 gr, 2000 gr and without condensation force. All specimens were stored in the air for 24 hours, then specimens were immersed in the various kind of dye solution for different period of time (1 hour and 24 hours). These dye-treated specimens were polished horizontally until removing 0.5mm of each surface on the emery paper (#1000), and the dye penetration in the polished surface was measured under the digital microscope (Japan Fosuh). Following results were obtained 1. The penetration of dyes was the most excessive in Durafill and was not influenced on the condensation force and the period of immersion time. 2. All dyes were penetrated into Hipol, and Crystal violet was penetrated most excessively in all dyes. 3. The penetration of dye in all resins was not influenced by the period of immersion time and condensation force. 4. There was no evidence of dye penetration in unfilled resin.

  • PDF

A STUDY ON THE EFFECT OF DENTIN BONDING AGENTS APPLIED OVER ENAMEL ABOUT THE BOND STRENGTH OF COMPOSITE RESIN (접착강화제가 치아경조직과의 접착강도 변화에 미치는 영향에 관한 연구)

  • Choi, Woong-Dae;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.1-16
    • /
    • 1995
  • The purpose of this study was to investigate the effect of dentin bonding agents on the bond strength of composite resin restorations in case of applying the dentin bonding agents to acid etched enamel surfaces. Freshly extracted 364 bovine anterior teeth were selected as a adherents. 320 enamel specimens were divided into two groups(unetched group (1) and etched group (2) for testing the shear bond strength, 40 specimens were used for the hardness testing, and 4 specimens of rest were to observe the resin-tag formation into etched enamel surfaces. All surfaces of enamel specimens were polished with 320~1500 SiC paper under continuous running water. In Group (1), 100 enamel specimens were polished and unetched. 220 polished enamel specimens in Group (2) were etched with 37 % phosphoric acid solution for 60 seconds, washed with water for 20 seconds, and dried with a light air pressure for 60 seconds. Three kinds of dentin bonding agents(Gluma, Prisma, Scotchbond 2) were evaluated the effect on the bond strength to conditioned enamel surfaces. Shear bond strengths were measured on the three cases such as a coating of primer only, a coating of sealer only, and a sequential coating of primer and sealer to acid etched enamel surfaces were compared with the bond strengths measured by the coating of enamel bonding agent followed by the bonding of composite resin (Photo clearfil bright, Kuraray, Japan) to unetched and acid etched enamel surfaces. In addition, the hardness tested on the adhesive fractured surface between composite resin enamel as a mean of evaluation of a factor whether the mechanical bond strengths were affected and the penetration of dentin bonding agents into etched enamel surfaces was also observed. Bond strengths were measured using the method of shear bond strength by a universal testing machine (Instron-4467, USA), statistical test were applied to the results using a one way analysis variance(ANOVA), and hardness was measured by the Vicker's Hardness Tester(MHT-i, Matsuzawa, Japan) and the penetration of the resins were observed by the SEM (Hitachi, S-2300, Japan). The following conclusions were drawn; 1. Enamel bonding agent showed to affect the improvement of bond strength of composite resin to enamel surface both unetched and etched. 2. Dentin bonding agents could be resulted in increase of bond strength to unetched enamel surface, but there were no statistical significances. 3. Bond strengths to etched enamel surface were significantly decreased with a coating of dentin primer only. 4. Coating of sealer only and coating of primer and sealer noticed the similar bond strengths of composite resin to etched enamel using the enamel bonding agents. 5. The applying method proved to be more effective than the kinds of dentin bonding agents on the bond strength of composite resin to etched enamel than the kind of dentin. 6. Vicker's hardness numbers of dentin bonding agents were lower than that of composite resin, but the degree of penetration of dentin bonding agents into etched enamel surfaces was excellent.

  • PDF

A Fundamental Study of the Bonded SOI Water Manufacturing (Bonded SOI 웨이퍼 제조를 위한 기초연구)

  • 문도민;강성건;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.921-926
    • /
    • 1997
  • SOI(Silicon On lnsulator) technology is many advantages in the gabrication of MOS(Metal-Oxide Semiconductor) and CMOS(Complementary MOS) structures. These include high speed, lower dynamic power consumption,greater packing density, increased radiation tolearence et al. In smiple form of bonded SOL wafer manufacturing, creation of a bonded SOI structure involves oxidizing at least one of the mirror polished silicon surfaces, cleaning the oxidized surface and the surface of the layer to which it will be bonded,bringing the two cleanded surfaces together in close physical proximity, allowing the subsequent room temperature bonding to proceed to completion, and than following this room temperature joining with some form of heat treatment step,and device wafer is thinned to the target thickness. This paper has been performed to investigate the possibility of the bonded SOI wafer manufacturing Especially, we focused on the bonding quality and thinning method. Finally,we achieved the bonded SOI wafer that Si layer thickness is below 3 .mu. m and average roughness is below 5.angs.

  • PDF