• Title/Summary/Keyword: Lower discharge

Search Result 1,025, Processing Time 0.051 seconds

A Study on the Optimum Preparation Conditions of MgO Protecting Layer in AC PDP by Unbalanced Magnetron Sputtering (불평형 마그네트론 스파터링에 의한 AC PDP용 MgO 보호층의 최적형성조건에 관한 연구)

  • Kim, Young-Kee;Park, Jung-Tae;Kim, Gyu-Seup;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1096-1098
    • /
    • 1999
  • The performance of as plasma display panels (PDP) is influenced strongly by the surface glow discharge characteristics on the MgO thin films. This paper deals with the optimum preparation conditions of MgO Protecting layer by RF unbalanced magnetron sputtering(UBMS) in surface discharge type AC PDP. The samples prepared with the do bias voltage of -10V showed lower discharge voltage, lower erosion rate as a consequence of ion bombardment, higher optic transparency and higher crack resistance in annealing process than those samples prepared by conventional magnetron sputtering or E-beam eraporation.

  • PDF

Development of a Low Noise and High Efficiency Rotary Compressor by a New Muffler (신규 저소음 및 고효율 머플러 적용 회전식 압축기 개발)

  • Jarng, In-Sun;Kim, Bong-Jun;Youn, Young;Sung, Choon-Mo;Lee, Seung-Gap
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.533-539
    • /
    • 2004
  • The rotary compressor is widely used for the air conditioner because it is efficient and compact. In recent, the need for silent and efficient compressors is much stronger than the past. The new type muffler was invented to reduce noise level and to improve efficiency. The new type muffler that has two side discharge holes and dome shape represents much lower overall noise level, especially noise levels around 1kHz than the old type one that has one center discharge hole In acoustic spectra. Also it has higher air conditioner efficiency by lower oil discharging amount of a compressor than old type one that has rectangular shape and two side discharge holes. The noise reduction and efficiency improvement effects of the new type muffler were verified by tests for rotary compressors and air conditioners.

  • PDF

Evaluation of Applicability for Nonpoint Discharge Coefficient using Watershed Model (유역모형을 이용한 비점배출계수 적용성 평가)

  • Lee, Eun Jeong;Kim, Tae Geun
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.3
    • /
    • pp.339-352
    • /
    • 2012
  • Total maximum daily load have been implemented and indicated that nonpoint discharge coeffients in flow duration curve were 0.50 of Normal flow duration ($Q_{185}$) and 0.15 of low flow duration($Q_{275}$). By using SWAT, nonpoint discharge coefficients are studied with the conditions of the instream flow and the rainfall in two study areas. The nonpoint discharge coefficient average of BOD and TP for normal flows duration in 3 years are 0.32~0.36 and 0.28~0.31. For the low flow duration, the nonpoint discharge coefficient avergae of BOD and TP were 0.10~0.12 and 0.10~0.11. These are lower than the coefficients of total maximum load regulation. There are big differences between one of regulation and one of SWAT for the normal flow duration. With the consideration of rainfall condition, the nonpoint discharge coefficient of flood flow duration are influenced on the amount of rainfalls. However, the nonpoint discharge coefficients of normal flow duration and low flow duration are not effected by the rainfall condition. Since the spatial distribution and geomorphological characteristics could be considered with SWAT, the estimation of nonpoint discharge coefficient in watershed model is better method than the use of the recommended number in the regulation.

Characteristics of Laser-Guided DC Discharge by Nd: YAG Laser at Low Pressure

  • Lee, Dong-Hoon;Kim, Hee-Je
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.3
    • /
    • pp.316-321
    • /
    • 1998
  • In recent years, concern has been raised about the technique of controlling electrical breakdown by using laser in many fields. Especially, laser has attracted much attention in the Electro-Discharge Macining(EDM) because of its many merits. Therefore, this research has been performed to obtain fundamental data relevant to discharge processing by using a pulsed Nd:YAG laser. The experiments of laser-guided dc discharge by laser radiation have been carried out at low air pressure ranging from 0.2 to 20 torr. The minimum laser-guided dc discharge voltage V\ulcorner at the given pressures P and distances D between an anode and a cathode was measured. It is found that the minimum laser-guided dc discharge voltage is much lower than the natural discharge voltage V\ulcorner\ulcorner, and the values of V\ulcorner and V\ulcorner as a function of P.D has a similar tendency. The laser output energy Eout decreases with input pulse duration tp increasing, and the more the value of tp increases, the higher that of V\ulcorner is obtained because the number of photons during the discharge time N decreases with t\ulcorner increasing. There is the time lag frequently when the discharge by laser radiation is misguided under the condition of the applied voltage less than V_G.min.

  • PDF

Experimental Study on the Effect of Plasma Reactor Type on Corona Discharge and NO-NO2 Conversion Characteristics (플라즈마 반응기구조에 따른 코로나방전 및 NO-NO$_2$ 전환특성에 관한 실험적 연구)

  • 박용성;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.65-71
    • /
    • 2002
  • Characteristics of corona discharge of the different types of the plasma reactors which are cone-hole and cone-plate is investigated experimentally. The discharge starts at lower voltage for the cathode corona than the anode corona and spark occurs at higher voltage for the cathode corona. And the cathode corona makes more stable discharge than the anode corona. The effect of the base gas in corona discharge for different O$_2$/N$_2$ concentrations is related with the gas molecular weight. The discharge for the smaller molecular weight gas occurs easier than for the high molecular weight gas. The discharge current decreases with the increase of oxygen concentration and it increases more sharply for anode corona than for cathode corona as discharge voltage increases after corona onset voltage. NO-NO$_2$ conversion increases with the energy density of corona discharge and the addition of O$_2$ in a base N$_2$ gas.

A Study on the Characteristics on a Discharge Cell by the Electrode Gap Using 2-D Simulation (2차원 시뮬레이션을 이용한 전극 간격에 따른 방전셀 내부의 특성 연구)

  • Lee, Don-Kyu
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.524-528
    • /
    • 2019
  • Although different types of discharge cells exist, in common it is the primary goal for all discharge cells to have lower drive voltages and higher efficiency characteristics. To improve these factors, many studies are conducted that prolong the discharge path inside the discharge cell or change the composition of the working gas. In this paper, the two-dimensional fluid simulation was used to calculate the discharge voltage (firing voltage and sustain voltage) and the change in luminance and luminous efficacy according to the change in gap distance between discharge electrodes. In addition, we looked at changes in various charged particles, exciting particles and VUV particles, and studied the causes of the resulting values.

Frictional Characteristics of Wire Electric Discharge Machined STDll Surface (STD11 와이어 방전가공면의 마찰특성)

  • 김영욱;조성산
    • Tribology and Lubricants
    • /
    • v.16 no.4
    • /
    • pp.253-258
    • /
    • 2000
  • Frictional behavior of wire electric discharge machined surfaces of spheroidized annealed STDll steel was investigated. The surfaces were produced with a various series of finish cuts where pulse energy was reduced with increase in the number of finish cuts. Roughness and micro-hardness of the surfaces were also measured. It is observed that the increase in the number of finish cuts produces the surface exhibiting lower frictional resistance followed by higher resistance after considerable wear. Effects of finish cuts on the friction characteristics are discussed with the aid of roughness and micro-hardness of the surfaces.

Changes in Nutritional Status according to Biochemical Assay, Body Weight, and Nutrient Intake Levels in Gastrectomy Patients (위절제 환자들의 혈액의 생화학적 지표, 체중 및 영양소 섭취 변화에 관한 추적 연구)

  • Yu, Eun-Joo;Kang, Ju-Hee;Yoon, Sun;Chung, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.18 no.1
    • /
    • pp.16-29
    • /
    • 2012
  • The purpose of this study was to investigate the changes in nutritional status of gastrectomy patients. The anthropometric and biochemical data were measured at pre-operation, at discharge, 1 month after discharge, and 3 months after discharge. Nutrient intake levels, nutrients adequacy ratio (NAR), mean adequacy ratio (MAR), and the proportion of patients with intake levels inferior to those of dietary reference intakes (DRIs) were analyzed at discharge, 1 month after discharge, and 3 months after discharge. Finally, the data on 23 patients (15 male and 8 female) were collected and used for statistical analysis. Fifteen patients underwent subtotal gastrectomy, and 8 patients underwent total gastrectomy. Compared to pre-operation, body weight and body mass index of subjects significantly decreased at discharge, 1 month after discharge, and 3 months after discharge (P<0.001). Serum albumin (P<0.001), total lympocyte count (P<0.001), total cholesterol (P<0.001), hemoglobin (P<0.001), hematocrit (P<0.001), and mean corpuscular hemoglobin concentration (P<0.05) were significantly different between pre-operation, at discharge, 1 month after discharge, and 3 months after discharge. The proportions of patients with lower nutrient intake levels than DRIs were substantial. MAR at discharge, 1 month after discharge, and 3 months after discharge were 0.70, 0.80 and 0.91, respectively. Especially, the NARs of folate, niacin, vitamin $B_2$, vitamin C, and zinc were all low. Considering the various nutritional problems of gastrectomy patients, systematic medical nutrition therapy is needed after gastrectomy.

A Study on the V22Ti16Zr16Ni39X7(X=Cr, Co, Fe, Mn, Al) Metal Hydride Electrodes (V22Ti16Zr16Ni39X7(X=Cr, Co, Fe, Mn, Al) 금속수소화물전극에 관한 연구)

  • Kim, Jeong-Seon;Cho, Won-Il;Cho, Byung-Won;Yun, Kyung-Suk;Kim, Sang-Joo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • Lattice structure, hydrogen absorption characteristics, discharge capacity and cycle life of $V_{22}Ti_{16}Zr_{16}Ni_{39}X_7$(X= Cr, Co, Fe, Mn, Al) alloys were investigated. The matrix phases of these alloys were the C14 Laves phase. Chromium-containing alloy had a vanadium-rich phase in addition to the Laves phase. The chromium, maganese, or aluminum-containing alloys had lower hydrogen equilibrium pressure and larger hydrogen absorption content than the cobalt or iron-containing alloys. The discharge capacities of these alloys were 270~330mAh/g. The discharge capacity according to the alloying element X decreased in the order of Mn>Cr>Co, Al)Fe. The charge/discharge cycle lives of the chromium, cobalt or iron-containing alloys were longer than those of maganese or aluminum-containing alloys due to the lower vanadium dissolution rate.

  • PDF

Preparation of MgO Protective Layer for AC PDP by Unbalanced Magnetron Sputtering (불평형 마그네트론 스파터링에 의한 AC PDP의 MgO 보호층 형성에 관한 연구)

  • Ko, Kwang-Sic;Kim, Young-Kee;Park, Jung-Tae;Kim, Eun-Chin;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.142-145
    • /
    • 2000
  • The performance of ac plasma display panels (PDP) is influenced strongly by the surface glow discharge characteristics on the MgO thin films. This paper deals with the surface glow discharge characteristics and some physical properties of MgO thin films prepared by reactive RF planar unbalanced magnetron sputtering in connection with ac PDP. The samples prepared with the dc bias voltage of -10V showed lower discharge voltage and lower erosion rate by ion bombardment than those samples prepared by conventional magnetron sputtering or E-beam evaporation. The main factor that improves the discharge characteristics by bias voltage is considered to be due to the morphology changes or crystal structure of the MgO thin film by ion bombardment during deposition process.

  • PDF