• 제목/요약/키워드: Lower attachments

검색결과 20건 처리시간 0.023초

Prosodic Disambiguation of Low versus High Syntactic Attachment across Lexical Biases in English

  • Jeon, Yoon-Shil;Yoon, Kyu-Chul
    • 말소리와 음성과학
    • /
    • 제4권1호
    • /
    • pp.55-65
    • /
    • 2012
  • In this study, the prosodic disambiguation of the syntactic attachment differences was investigated in relation to the effect of lexical bias. Speech materials were composed of N1-conj-N2-PP phrases such as "walkers and runners with dogs." The results show that the use of durational pattern is dominant over the pitch pattern to differentiate the attachment differences. The characteristic pitch contour was the rise and fall over N1 and N2 in the high attachment. The pitch contour in the low attachment was the rise and fall over N2 and N3 although the frequency of such patterns was lower for the low attachment case. For the durational pattern, the lengthening in the N2 region plays a significant role in the disambiguation of the syntactic attachments. The interaction between the lexical bias and the syntactic attachment was not statistically significant in the duration data.

CRS의 부착방식에 따른 어린이 탑승자 안전도 비교 (Child Occupant Safety According to the ISOFIX Type of CRS)

  • 이재완;윤영한;박경진
    • 한국자동차공학회논문집
    • /
    • 제11권4호
    • /
    • pp.86-93
    • /
    • 2003
  • These days, automobile industry pays considerable attention to child occupant safety. As the US adopted requirements for universal and uniform anchor systems for child restraints, manufacturers for child seats put an enormous effort to improve the protective properties of Child Restraint System (CRS). Various standards have been studied and announced by different countries. The anchorage system is the most important in the CRS and the rules of universal anchor are to provide devices which are independent of safety belts. A new concept called International Standard Organization Fixture (ISOFIX) has been announced. It suggests some designs for the CRS. In this study, the suggested designs are evaluated with domestic products. Tests are performed and the results are incorporated into a finite element modeling process. As the finite element model is established, various numerical tests are conducted and the numerical results are discussed. A commercial software system is utilized for the nonlinear finite element analysis.

Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient

  • Ha, Seung-Ryong;Kim, Sung-Hun;Song, Seung-Il;Hong, Seong-Tae;Kim, Gy-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.254-258
    • /
    • 2012
  • Implant-supported overdenture is a reliable treatment option for the patients with edentulous mandible when they have difficulty in using complete dentures. Several options have been used for implant-supported overdenture attachments. Among these, bar attachment system has greater retention and better maintainability than others. SFI-Bar$^{(R)}$ is prefabricated and can be adjustable at chairside. Therefore, laboratory procedures such as soldering and welding are unnecessary, which leads to fewer errors and lower costs. A 67-year-old female patient presented, complaining of mobility of lower anterior teeth with old denture. She had been wearing complete denture in the maxilla and removable partial denture in the mandible with severe bone loss. After extracting the teeth, two implants were placed in front of mental foramen, and SFI-Bar$^{(R)}$ was connected. A tube bar was seated to two adapters through large ball joints and fixation screws, connecting each implant. The length of the tube bar was adjusted according to inter-implant distance. Then, a female part was attached to the bar beneath the new denture. This clinical report describes two-implant-supported overdenture using the SFI-Bar$^{(R)}$ system in a mandibular edentulous patient.

인중의 미세해부학적 고찰 (Microanatomy of Philtral ridge)

  • 이종호;전세일;명훈;임구영;서병무;최진영;정필훈;김명진;홍삼표;이재일;임창윤
    • 대한구순구개열학회지
    • /
    • 제3권1호
    • /
    • pp.11-16
    • /
    • 2000
  • 구순열 수술에서 인중의 해부, 형태, 기능적 재건에 도움을 받고자 상순 및 하순의 전층표본을 가지고 미세구조를 관찰하였으며, 자연스럽고 미적인 인중을 재건하기 위해서는 정상적 근육 부착의 재건과 구륜근 표층의 진피 부속물들의 회복과 장력 없는 상순의 접합, 진피 부속물들을 포함한 인중융기의 두께 회복 및 비탄력성 흉터 조직의 최소화가 필요하다고 사료되었다.

  • PDF

측두하악관절 내장 환자의 관절원판과 관절원판 후조직의 자기공명영상 신호강도 (Magnetic resonance imaging signal intensity of temporomandibular joint disk and posterior attachment in patients with internal derangement)

  • 정연화;조봉혜
    • Imaging Science in Dentistry
    • /
    • 제31권2호
    • /
    • pp.93-99
    • /
    • 2001
  • Purpose: To analyze the possible association between magnetic resonance imaging signal intensity of temporomandibular joint disk and posterior attachment, and the type and extent of disk displacement, disk configuration, effusion and clinical signs in patients with internal derangement. Materials and Methods: Magnetic resonance images of the 132 temporomandibular joints of 66 patients with temporomandibular joint displacement were analyzed. The clinical findings were obtained by retrospective review of the patients' records. The type and extent of disk displacement, disk configuration and effusion were evaluated on the proton density MR images. The signal intensity from the anterior band, posterior band and posterior attachment were measured on MR images. The associations between the type and extent of disk displacement, disk configuration, effusion and clinical signs and the MR signal intensity of disk and posterior attachment were statistically analyzed by student's t-test. Results: Of 132 joints, 87 (65.9%) showed anterior disk displacement with reduction (ADR) and 45 (34.1%) showed anterior disk displacement without reduction (ADnR). The signals from posterior attachments were lower in joints with ADnR than those of ADR (p<0.05). The results showed statistically significant (p<0.05) association between the type and extent of disk displacement and disk configuration, and decreased signal intensity of posterior attachment. There were no statistical associations between pain, noise and limited mouth opening, and signal intensity of disk and posterior attachment. Conclusions: The average signal from posterior attachment was lower in joints with ADnR than that of ADR. The type and extent of disk displacement and disk configuration appeared to be correlated with the signal intensity from posterior attachment.

  • PDF

악관절에 대한 자기 공명 영상의 연구 (A STUDY ON MAGNETIC RESONANCE IMAGING OF THE TEMPOROMANDIBULAR JOINT)

  • 김형식;김재덕
    • 치과방사선
    • /
    • 제20권2호
    • /
    • pp.187-198
    • /
    • 1990
  • Examinations of the temporomandibular joints were performed on a 1.5 Tesla magnetic resonance (MR) system. An MR surface receiver coil 3 inch in diameter was placed on plastic frame, the patient's head being placed in the frame so that the coil was pressed against the temporal region. In taking advantage of the magnetic resonance imaging that has been studied briskly till now, author obtained the images of parasagittal and paracoronal planes about the temporomandibular joint by using MPGR (Multi-Planar Gradient Recalled), GRASS (Gradient Recalled Acquisition in the Steady State), and CSMEMP (Contiguous Slice Multiple Echo, Multi-Planar), that differ from the Spin Echo pulse sequence which the previous authors used. Five subjects with no symptoms of temporomandibular joint pain and dysfunction were studied. The plane images obtained by these methods were compared with those by Spin Echo pulse sequence. The results were as follows: 1. The optimal repetition times (TR) and echo times (TE) for T.M.J. image were; a. 400 msec and 18 msec in PMGR pulse sequence. b. 40 msec and 12 msec in GRASS pulse sequence. c. 700 msec and 30 msec in CSMEMP pulse sequence. d. 500 msec and 20 msec in Spin Echo pulse sequence. 2. When the MPGR pulse sequence was using, T2-weighted image was obtained in very short time. On the image of the paracoronal plane by GRASS pulse sequence, meniscus showed the moderate signal intensity, and the meniscus and its anteromedial, posterolateral attachments were observed definitely with gray color. 4. The signal intensity of Spin Echo pulse sequence was equal to that of CSMEMP pulse sequence, but the image by CSMEMP pulse sequence showed relatively lower level in its resolution.

  • PDF

단말의 마이크로 이동성을 고려한 자원예약 메커니즘의 설계 (A Design of Resource Reservation Mechanism with Micro Host Mobility)

  • 고광신;차우석;안재영;조기환
    • 정보처리학회논문지C
    • /
    • 제9C권5호
    • /
    • pp.733-742
    • /
    • 2002
  • 이동 컴퓨팅 환경에서 사용자의 이동 특성은 실시간 멀티미디어 서비스를 제공하기 위해서 요구되는 QoS에 심각한 영향을 미친다. 기존의 유선환경에서 실시간 서비스를 제공하기 위해서 제안된 RSVP 프로토콜을 이동 사용자의 네트워크 접속점이 수시로 변화하는 이동 컴퓨팅 환경에 적용하기에는 부적합하다. 사용자의 이동이 QoS에 미치는 영향을 최소화하기 위해서 사용자가 이동할 것으로 예상되는 영역에 대한 자원을 미리 예약하는 프로토콜이 MRSVP(Mobile RSVP)이다. 본 논문은 기존의 MRSVP를 확장하여 RSVP Tunnel 및 Mobile IP의 지역 등록(Regional Registration) 프로토콜이 결합된 동적 이중 앵커노드(DDAN : Dynamic Dual Anchor Node) 구조를 제안한다. 이는 기존의 MRSVP 프로토콜에서 미리 예약되는 자원을 지역적으로 제한함으로써 자원예약을 최소화시키는 반면에, 기존의 MRSVP와 유사한 수준의 QoS 보장을 목적으로 한다.

상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포에 대한 유한요소분석 (Effect of attachments and palatal coverage of maxillary implant overdenture on stress distribution: a finite element analysis)

  • 박종희;왕원곤;이정진;박연희;서재민;김경아
    • 구강회복응용과학지
    • /
    • 제36권2호
    • /
    • pp.70-79
    • /
    • 2020
  • 목적: 상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포를 3차원 유한요소분석법을 통해 알아보고자 한다. 연구 재료 및 방법: CAD를 이용하여 전방부에 4개의 임플란트를 식립한 4종류의 상악 임플란트 피개의치에 대한 3차원 모델을 디자인하였다. 1) Ball-F: 볼 유지장치를 사용하고 구개를 피개한 군, 2) Ball-P: 볼 유지장치를 사용하고 구개를 피개하지 않은 군, 3) Bar-F: 바 유지장치를 사용하고 구개를 피개한 군, 4) Bar-P: 바 유지장치를 사용하고 구개를 피개하지 않은 군. 응력분석은 유한요소 분석 프로그램인 ANSYS Workbench Ver. 14를 사용하였으며, 편측 저작의 상황을 고려하여 우측 제1대구치에 100 N의 정적하중을 적용하여 임플란트, 임플란트 주위 골, 점막에 발생하는 최대 응력값을 기록하였다. 결과: 볼 유지장치를 사용한 군이 바 유지장치를 사용한 군보다 임플란트 및 임플란트 주위골에 발생하는 최대 응력값이 작았다. 하지만 점막에서의 최대 응력값은 그 반대로 나타났다. 구개를 피개하면 유지장치의 종류와 무관하게 임플란트, 임플란트 주위 골, 점막 모두에서 최대응력값이 작아졌다. 결론: 본 연구의 한계 내에서 상악동 전방부에 4개의 임플란트를 식립하여 수복된 피개의치에서 바 유지장치보다는 볼 유지장치를 사용하고 구개를 완전히 피개하는 경우가 임플란트와 임플란트 주위 골의 응력분산에 효과적이다.

임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교 (Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment)

  • 최재원;채성기;허중보
    • 대한치과보철학회지
    • /
    • 제59권2호
    • /
    • pp.173-180
    • /
    • 2021
  • 목적: 본 연구는 반복적인 착탈에 따른 임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장치의 유지력 특성을 평가해보고자 하였다. 재료 및 방법: 본 연구에서는 새롭게 개발된 유지장치(ADD-Lock; AL)와 기존의 상용화된 유지장치(Locator blue; LB)의 두 가지 유지장치를 평가하였다. 두 개의 고정체를 하부 구조물에 평행하게 위치시키고, 각 유지장치의 patrix를 고정체에 연결하였다. 각 유지장치의 matrix는 대합되는 상부 구조물에 위치시키고 고정하였다. Universal testing machine을 이용하여 초기, 100, 250, 500, 1000, 2000, 2500회의 반복적인 착탈 동안에 각 유지장치의 유지력을 측정하였다. 유지장치의 마모 및 변형 정도는 주사전자현미경으로 관찰하였다. Kruskal-Wallis test, Mann-Whitney U test (α = .05), 그리고 wilcoxon signed-rank test (α = .05)를 이용하여 통계분석 실시하였다. 결과: 초기 유지력과 2500회의 반복적인 착탈 후 유지력에서, AL군(15.24 ± 1.46 N, 9.74 ± 1.16 N)은 LB군(43.53 ± 12.39 N, 22.99 ± 4.77 N)보다 유의하게 작은 값을 보였다(P < .05). 또한, 유지력 소실량에 있어서도 AL군(5.50 ± 1.08 N, 36.08%)이 LB군(20.54 ± 11.89 N, 47.19%)에 비해 낮은 값을 보였다(P < .05). 주사전자현미경 분석 결과, AL군은 patrix에서, LB군은 matrix에서 눈에 띄는 마모 및 변형이 관찰되었다. 결론: Locator는 새롭게 개발된 유지장치보다 높은 초기 유지력을 보인 반면 높은 유지력 소실량을 보였다. 한편, 두 가지 부가적인 유지장치는 반복적인 착탈 후에도 충분한 유지력을 가지는 것으로 나타났다.

무치악 환자에서 기성 조립식 bar를 이용한 임플란트 피개의치 증례 (Implant-retained overdentures with pre-fabricated bar attachment system in edentulous patients)

  • 소나영;홍영기;하승룡
    • 대한치과보철학회지
    • /
    • 제54권1호
    • /
    • pp.41-48
    • /
    • 2016
  • 치아 상실에 이어 심각한 치조골 소실을 보이는 무치악 환자들은 전통적인 방식의 총의치를 사용하는데 어려움이 많다. 이러한 문제를 보완할 수 있도록 임플란트를 이용한 피개의치가 사용되고 있다. SFI-bar$^{(R)}$는 진료실에서 직접 조정이 가능한 기성품으로 복잡한 기공과정을 필요로 하는 기존의 바 시스템보다 간결하여 시간과 비용을 절감할 수 있다. 첫 번째 증례는 55세 남자 환자로 기존 하악 임플란트-지지 피개의치가 파절되었다는 주소로 내원하였고 내구성이 있으며 통증이 없는 의치를 원하였다. 파절된 Locator$^{(R)}$ 어태치먼트를 제거 후 바를 이용한 피개의치로 치료하였다. 두 번째 증례는 파킨슨병을 앓고 있는 77세 여자 환자로 하악 치조골이 심각하게 흡수되어 의치가 자주 탈락한다는 주소로 내원하였고 통증이 없고 유지력이 있는 의치를 원하였다. 하악 전치부에 두개의 임플란트를 식립한 후 임플란트에 연결된 어댑터에 바를 연결하였다. 그 후 바에 맞는 여성부를 새로운 의치에 장착하여 치료하였다. 2년의 추적 관찰 결과 상기 환자 모두 심미적, 기능적으로 만족할만한 결과를 보였으므로 증례를 보고하고자 한다.