• Title/Summary/Keyword: Lower Structure

Search Result 4,955, Processing Time 0.037 seconds

A Study on the Correlationship between Spatial Structure and Shop Composition in Mixed-Use Facilities - Focused on the Typological Analysis about Lower Part of the Facilities Built After the Year 2000 - (복합상업시설 실내 공간구조와 매장구성 성향간 상관성 분석 - 2000년대 건립사례 저층부의 유형학적 분석을 중심으로 -)

  • Hyun, Chang-Yong
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.6
    • /
    • pp.62-70
    • /
    • 2017
  • This study has a purpose that definitize correlationship of spatial structure and sales strategies in mixed-use complexes which established in Korea since year 2000. For this purpose, this study tries to analysis spatial structure of mixed-use facilities through space syntax theory and makes an typological categorization based on their space composition. As a result of categorization, Korean mixed-use facilities can be classed as three types. First type is integrated stacking type. Second one is parallel connecting type. Third type is room to room type. According to differences between categories, their spatial structures show different meaning with different sales strategies. Integrated stacking type sales luxury brands and expensive stuffs and it also has deep and complicated structure. That means theses spaces usually make a strategy of exclusion. Parallel connecting type sales special categories and it also has shallow and easy spatial structure. That means these facilities want to make a smooth connection between apposed volumes. Room to room type sales cheap and fancy objects and it also has simple and shallow structure. That means simple spatial structure can be lead contact customer to stuffs. These results mean spatial structure have a effect on design of sales space.

Electromigration Characteristics Stduy DCV Interconnect Structures in Cu Dual-Damascene Process (Cu Dual Damascene 배선 공정에서의 DCV 배선구조의 EM 특성 연구)

  • Lee, Hyun-Ki;Choi, Min-Ho;Kim, Nam-Hoon;Kim, Sang-Yong;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.123-124
    • /
    • 2005
  • We investigated the effect of a Ta/TaN Cu diffusion barrier existence on the reliability and the electrical performance of Cu dual-damascene interconnects. A high EM performance in Cu dual-damascene structure was observed the BCV(barrier contact via) interconnect structure to remain Ta/TaN barrier layer. Via resistance was decreased DCV interconnect structure by bottomless process. This structure considers that DCV interconnect structure has lower activation energy and higher current density than BCV interconnect structure. The EM failures by BCV via structure were formed at via hole, but DCV via structure was formed EM fail at the D2 line. In order to improve the EM characteristic of DCV interconnect structure by bottomless process, after Ta/TaN diffusion barrier layer in via bottom is removed by Ar+ resputtering process, it is desirable that Ta thickness is thickly made by Ta flash process.

  • PDF

A Study on the Scale and Dimensions of member of Sectional structure for Five-Purlin Houses from Joseon Era (조선시대 민가 오량가(五樑架) 종단구성의 규모와 부재치수에 관한 연구)

  • Kim, Jae-Ung
    • Journal of architectural history
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2019
  • As a part of the research on existing structures of private homes from Joseon Era. Focusing on one hundred twenty five-purlin houses, the current study investigated the features and characteristics of the house structure from style, size, proportion and roof pitch, and measurements of key parts, and developed the following conclusions. Most are single-houses (89, 83%), and among them, there are 47 single front-terrace houses (39%), which is the highest number. The sizes of lower house structure do not differ greatly depending on the vertical structure, and single rear terrace house and double-house have relatively larger side sizes. The size of upper structure is larger in double-houses compared to other vertical structures, indicating a relatively higher roof. The cross-section measurement of major parts show that double-houses are larger than single-houses by 3cm in pillar, 3-4.5cm in crossbeam length, and 4.5cm in crossbeam width. However, Janghyeo width was consistent at 7.5 to 10.5cm, maintaining uniformity regardless of vertical structure of the houses. In addition, the cross-section measurements decreased from sixteenth to nineteenth century, with the size of pillar size decreasing the most. The result that the Janghyeo width is not related to the house structure house confirmed that the Janghyeo width was kept consistent regardless of the size of the house structure.

Analysis on Lower Body Type and 3D Virtual Appearance Evaluation of Boots cut Jeans for Women (성인여성의 하반신 체형분석 및 부츠 컷 청바지의 가상 외관평가)

  • Choi, Jin;Do, Wol-Hee
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.2
    • /
    • pp.73-83
    • /
    • 2008
  • The focus of this research was concerned with studying lower body type for Korean adult females. information from the measuring values based on research on the physical standard of the nation(2004) were summarized, in addition a factor of the need for appropriate fit in boots cut jean wear, basic lower body part applying to each item had to be taken into consideration to enhance sizing suitability. The body type are classified into three kinds by means of factor analysis and cluster analysis. Type 1 referred to the fat lower body, having thick rounding waist. compared to other body parts, and long leg according to its proportion. Type 2 represented medium stature but with a large skeleton structure of lower body. Type 3 represented a the long lower body having slender rounding waist. This study was attempted to evaluate the fitness of boots cut jeans pattern for women using 3D Clothes Modeling Software.

A STUDY ON MEASUREMENT OF MINIMAL DISTANCE BETWEEN PULP CHAMBER AND CORONAL SURFACE (치수강(齒髓腔)과 치관외면(齒冠外面)과의 최단거리(最短距離)에 관(關)한 실측연구(實測硏究))

  • Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.1-4
    • /
    • 1989
  • To determine the thickness of coronal hard structure the minimal distance between pupal surface and outer surface of crown was measured by means of Bowley gauge on extracted first molars. Upper(28 teeth) and lower(24 teeth) were carefully collected from 30-39 years of age and male. The teeth were split mesio-distally through central pit. On the split surface various part which are deeply related in cavity preparation were measured (schematic drawing). The results were as follows: A : Distance from mesio-cervical enamel to pulp chamber surface. upper $2.63{\pm}0.19$(mm) Lower $2.18{\pm}0.27$(um) B : Distance from mesial chamber ceiling to mesial surface upper $2.75{\pm}0.34$ Lower $2.62{\pm}0.31$ C : Distance from mesial chamber ceiling to occlusal surface upper $3.82{\pm}0.51$ Lower $3.49{\pm}0.50$ D : Distance from distal chamber ceiling to occlusal surface upper $4.28{\pm}0.69$ Lower $3.90{\pm}0.52$ E : Distance from distal chamber ceiling to distal surface upper $2.79{\pm}0.45$ Lower $2.41{\pm}0.40$ F : Distance from disto cervical enamel to pulp chamber surface upper $2.49{\pm}0.24$ Lower $2.39{\pm}0.25$.

  • PDF

Analysis of Vertical Structure of Atmosphere on the Middle Part of the Yellow Sea (서해 중부 해상 대기의 연직구조 분석)

  • Yun, Yong Hun;Im, Ju Yeon;Kim, Baek Jo;Kim, Tae Hui;Seo, Jang Won;Jo, Ha Man
    • Journal of the Korean earth science society
    • /
    • v.21 no.1
    • /
    • pp.22-22
    • /
    • 2000
  • To search out the characteristics of the lower and the upper atmospheric vertical structure, we selected the island(Oeyoundori Ochun-myen Poryeng city Chung-Nam) as an observation site, which is thought to represent the characteristics of ocean well, and observed the vertical structure of the atmosphere by Radiosonde. By using the results of the observation, we analyzed the changes of relative humidity(RH), temperature and wind when the cyclone and the anticyclone passed and compared the results in case of each event. To compare the vertical structure of the ocean atmosphere with those of the continent, we analyzed the values observed with using Radiosonde at Osan site.Through this study, we found that relative humidity changed as the cyclone and the anticyclone passed. That is, when the cyclone came, RH increased first in the upper atmosphere than in the lower and when the high came, RH in the upper decreased sharply to 10%. And the variations of relative humidity in ocean are bigger than those in continent. In the future, we plan to find out the relation between the vapor water in ocean and continent seasonally and daily through the observation in ocean and continent at same time.

Analysis of Vertical Structure of Atmosphere on the Middle Part of the Yellow Sea (서해 중부 해상 대기의 연직구조 분척)

  • Youn, Yong-Hoon;Lim, Joo-Yun;Kim, Baek-Jo;Kim, Tae-Hee;Seo, Jang-Won;Cho, Ha-Man
    • Journal of the Korean earth science society
    • /
    • v.21 no.1
    • /
    • pp.23-39
    • /
    • 2000
  • To search out the characteristics of the lower and the upper atmospheric vertical structure, we selected the island(Oeyoundori Ochun-myen Poryeng city Chung-Nam) as an observation site, which is thought to represent the characteristics of ocean well, and observed the vertical structure of the atmosphere by Radiosonde. By using the results of the observation, we analyzed the changes of relative humidity(RH), temperature and wind when the cyclone and the anticyclone passed and compared the results in case of each event. To compare the vertical structure of the ocean atmosphere with those of the continent we analyzed the values observed with using Radiosonde at Osan site. Through this study, we found that relative humidity changed as the cyclone and the anticyclone passed. That is, when the cyclone came, RH increased first in the upper atmosphere than in the lower and when the high came, RH in the upper decreased sharply to 10%. And the variations of relative humidity in ocean are bigger than those in continent. In the future, we plan to f d out the relation between the vapor water in ocean and continent seasonally and daily through the observation in ocean and continent at same time.

  • PDF

Seismic Response Analyses of the Structure-Soil System for the Evaluation of the Limits of the Site Coefficients (지반계수의 한계값 평가를 위한 구조물-지반체계에 대한 지진응답해석)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.1 s.53
    • /
    • pp.67-77
    • /
    • 2007
  • Site coefficients in IBC and KBC codes have some limits to predict the rational seismic responses of a structure, because they take into account only the effect of the soil amplification without the effects of the structure-soil interaction. In this study, upper and lower limits of the site coefficients are estimated through the pseudo 3-D elastic seismic response analyses of structures built on the linear or nonlinear soil layers taking Into account the effects of the structure-soil interaction. Soil characteristics of site classes of A, B and C were assumed to be linear, and those of site classes of D and E were done to be nonlinear and the Ramberg-Osgood model was used to evaluate shear modulus and damping ratio of a soil layer depending on the shear wave velocity of the soil layer, Seismic analyses were performed with 12 weak or moderate earthquake records scaled the peak acceleration to 0.1g or 0.2g and deconvoluted as earthquake records at the bedrock located at 30m deep under the outcrop. With the study results of the elastic seismic response analyses of structures, new standard response spectrum and upper and lower limits of the site coefficients of $F_{a}\;and\;F_{v}$ at the short period range and the period of 1 second are suggested including the effects of the structure-soil interaction, and new site coefficients for the KBC code are also suggested.

Low Actuation Voltage Capacitive Shunt RF-MEMS Switch Using a Corrugated Bridge with HRS MEMS Package

  • Song Yo-Tak;Lee Hai-Young;Esashi Masayoshi
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.2
    • /
    • pp.135-145
    • /
    • 2006
  • This paper presents the theory, design, fabrication and characterization of the novel low actuation voltage capacitive shunt RF-MEMS switch using a corrugated membrane with HRS MEMS packaging. Analytical analyses and experimental results have been carried out to derive algebraic expressions for the mechanical actuation mechanics of corrugated membrane for a low residual stress. It is shown that the residual stress of both types of corrugated and flat membranes can be modeled with the help of a mechanics theory. The residual stress in corrugated membranes is calculated using a geometrical model and is confirmed by finite element method(FEM) analysis and experimental results. The corrugated electrostatic actuated bridge is suspended over a concave structure of CPW, with sputtered nickel(Ni) as the structural material for the bridge and gold for CPW line, fabricated on high-resistivity silicon(HRS) substrate. The corrugated switch on concave structure requires lower actuation voltage than the flat switch on planar structure in various thickness bridges. The residual stress is very low by corrugating both ends of the bridge on concave structure. The residual stress of the bridge material and structure is critical to lower the actuation voltage. The Self-alignment HRS MEMS package of the RF-MEMS switch with a $15{\Omega}{\cdot}cm$ lightly-doped Si chip carrier also shows no parasitic leakage resonances and is verified as an effective packaging solution for the low cost and high performance coplanar MMICs.