• 제목/요약/키워드: Low-temperature energy source

검색결과 283건 처리시간 0.029초

$Er^{3+}$$Tm^{3+}$이 복합 첨가된 실리카 광섬유의 ASE 광원에 대한 특성 평가 (Characterization of amplified spontaneous emission light source from an $Er^{3+}$/$Tm^{3+}$co-doped silica fiber)

  • Jeong, Hoon;Oh, K.
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 제11회 정기총회 및 00년 동계학술발표회 논문집
    • /
    • pp.96-97
    • /
    • 2000
  • Incoherent broadband optical sources have been applied in various areas such as a light source for optical device characterization, fiber-optic gyroscopes$^{(1)}$ , and spectrum sliced light source in wavelength division multiplexing (WDM) system$^{(2)}$ . To utilize the inherent low loss in silica optical fibers, various types of incoherent light sources are being developed. Among the light sources, the amplified spontaneous emission (ASE) from a rare earth doped fiber has benefits in temperature stability, high output power, low polarization dependence over semiconductor diodes$^{(3)}$ . Recently erbium doped fibers (EDF) have been intensively researched for ASE sources as well as optical amplifiers$^{(4)}$ . The spectrum of ASE from an EDF, however, is limited in the 1520~1560 nm range in conventional configurations. In this letter we described a new broadband ASE source which included both the conventional ASE band of Er$^{3+}$ ion, 1520nm~1560nm and ASE band from Tm$^{3+}$ ions that extends the bandwidth further. For the first time, to the best knowledge of authors, a fiber ASE source based on the energy transfer between Er$^{3+}$ and Tm$^{3+}$ ions in the range of 1460~1550 nm, has been demonstrated using a single 980nm pump laser diode. (omitted)omitted)

  • PDF

재생 유기플래시 사이클의 열역학적 성능 해석 (Thermodynamic Performance Analysis of Regenerative Organic Flash Cycle)

  • 김경훈;김만회
    • 대한기계학회논문집B
    • /
    • 제40권9호
    • /
    • pp.589-596
    • /
    • 2016
  • 최근 들어 작동유체가 액체 상태를 유지하며 흡열 과정이 일어나는 증기동력사이클인 유기플래시 사이클이 제안되었다. 본 연구에서는 재생을 이용한 수정 유기플래시 사이클을 제안하고 현열 형태의 저온 열원을 사용하는 시스템의 열역학적 성능 해석을 수행하였으며 작동유체나 플래시 온도가 순생산 동력이나 열효율 등 시스템의 성능에 미치는 영향을 체계적으로 분석하고 논의하였다. 해석 결과는 시스템의 순생산동력은 플래시 온도에 대해 최대값을 갖지만 열효율은 플래시 온도에 따라 상승함을 보여준다. 재생 사이클은 기존의 유기플래시 사이클에 비해 시스템 열효율이 높고 저온 열원의 동력 변환에 있어 성능 개선을 위한 잠재성을 보여준다.

Thermal and Non-thermal Heat Flow in a Large Crystal Detector for Neutrinoless Double Beta Decay Search

  • Kim, G.B.;Lee, S.J.;Jang, Y.S.;Lee, H.J.;Lee, J.H.;Lee, J.Y.;Lee, M.K.;Yoon, W.S.;Kim, Y.H.
    • Progress in Superconductivity
    • /
    • 제14권2호
    • /
    • pp.87-91
    • /
    • 2012
  • Metallic magnetic calorimeters (MMCs) are one of the most competitive low temperature detector (LTD) readout sensors. They have the advantages of high time resolution, no heat dissipation, and a wide range of operating temperature. We apply MMCs to our neutrinoless double beta decay ($0v{\beta}{\beta}$) search experiment. A $CaMoO_4$ crystal was employed as both a source of $0v{\beta}{\beta}$ and an energy absorber. The crystal was thermally connected to a MMC sensor. We set a simple thermal model for this detector and measured pulse shapes are compared with a numerical solution of the thermal model.

폐기물 및 바이오매스 연료 사용시설의 효율적 에너지회수 및 온실가스 감축을 위한 운전조건에 관한 연구 (A study on the operation conditon of Effective Energy Recovery and Greenhouse gas Reduction by the facility using Waste / Biomass fuel)

  • 주원혁;여운호
    • 유기물자원화
    • /
    • 제28권1호
    • /
    • pp.83-95
    • /
    • 2020
  • 폐기물을 이용한 공공 자원회수시설, BIO-SRF를 이용한 민간 열원시설 열에너지를 효율적으로 활용함에 있어 투자 대비 회수 기간의 경제성 문제가 대두 되었고, 이로 인하여 기존에 통상적으로 설계 시공 운영 되었던 온도, 압력 조건 범위값을 넘어서 실현 가능한 최적의 온도, 압력 조건의 열원 설비가 필요하게 되었다. 본 연구에서는 국내에서 운영 중인 열원시설을 대상으로 온도와 압력 조건에 따른 모델링을 통하여 에너지 전력 생산량을 분석하였고, 도출된 에너지 전력 생산량을 통하여 온실가스 배출량 감축 특성을 연구하였다. 최종적으로 폐기물 및 바이오매스 연료를 이용한 열에너지 생산시설의 효율적인 에너지 활용을 위해서는 고온의 온도와 고압의 압력 생산시 효율적인 에너지 생산이 이루어지고 경제성 있는 투자와 회수로 이루어지리라 판단된다.

2-프로파놀의 탈수소화에 의한 수소제조 연구 (A Study on the Production of Hydrogen by 2-Propanol Dehydrogenation)

  • 심규성;김종원;김연순;박기배
    • 한국수소및신에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.11-16
    • /
    • 1995
  • Chemical heat pump is one of the energy conversion technologies, which enables to use waste heat as a source of high grade heat. In 2-propanol/acetone system, the dehydrogenation of 2-propanol is an endothermic(heat absorption) reaction, and can be used to generate hydrogen because 2-propanol can be converted to acetone and hydrogen at low temperature(about $8^{\circ}C$) using catalyst. For the dehydrogenation of 2-propanol 5% Ru catalyst based on activated carbon is the best one at the reaction temparature of $83^{\circ}C$.

  • PDF

TMA 농도에 따른 포접화합물의 냉각특성에 대한 연구 (A Study on Cooling Characteristics of Clathrate Compound with Concentration of TMA)

  • 김진흥;정낙규;김창오
    • 에너지공학
    • /
    • 제14권1호
    • /
    • pp.18-23
    • /
    • 2005
  • 본 연구는 저온축열물질로서 TMA(Tri-methyl-amine, (CH₃)₃N)를 20~25 wt%로 포함하고 있는 TMA-물계 포접화합물의 냉각특성에 대하여 냉열원온도 -5℃에서 실험적으로 연구를 수행하였다. 연구결과, TMA의 질량농도가 증가할수록 상변화온도와 비열이 증가하였으며, 과냉도가 감소하고 액상유지시간이 단축되었다 특히, TMA 25wt%를 포함한 TMA-물계 포접화합물은 상변화온도 평균 5.8℃, 과냉도 8.0℃, 액상유지시간 10분, 비열 4.099kJ/kg℃를 나타내었다. 본 연구의 결과로부터 TMA-물계 포접화합물은 물보다 높은 상변화온도를 나타내었으며, 과냉도가 감소하고, 액상유지시간이 단축되는 과냉각 억제효과를 확인 할 수 있었다.

NGH 특성 및 NGH 수송선 개요 (General Idea of NGH and NGH Carrier)

  • 강곤;이상수;김정훈
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 전기공동학술대회 논문집
    • /
    • pp.13-14
    • /
    • 2011
  • Methane Hydrates or Natural Gas Hydrates (hereinafter NGH) are solid-state energy source formed by the clathration of methane gas in water molecules at low temperature and high pressure. NGH is also known as "burning ice" because of its burning property and appearance similar to that of dry ice. Today, concerns about the NGH are rising as an environment-friendly energy source that can replace fossil fuels. In this paper, to keep pace with the research and development of the NGH, the properties of the NGH and the general features of NGH carriers are introduced.

  • PDF

고효율 수퍼히트펌프에 관한 전산 해석 (Computer Simulation of a Super-Heat Pump System)

  • 김학준;정동수;김종보;하경용
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.234-248
    • /
    • 1995
  • A super-heat pump system composed of a suction line heat exchanger, low and high stage economizers, and a screw compressor is simulated to examine the energy performance and design options. CFC12, HCFC22, HFC134a, HCFC22/HCFC142b, HFC32/HFC134a, and HFC125/HFC134a are used as working fluids for comparison. The results indicate that the proposed system charged with appropriate mixtures is up to 33.4% more energy efficient than the normal system with CFC12. The performance of the super-heat pump system charged with mixtures was influenced by such factors as the temperature matching, heat source temperature difference, low stage economizer, and high stage economizer. The fluids with a larger liquid specific heat such as HFC134a would have more benefits when a suction line heat exchanger is installed. 40%HCFC22/60%HCFC142b mixture seems to be a good candidate to replace CFC12. On the other hand, 25%HFC32/75% HFC134a would be a good long term candidate to replace HCFC22.

  • PDF

주공정에서 아질산화-혐기성 암모늄 산화법에 의한 단축질소제거공정 연구동향 (Main-stream Partial Nitritation - Anammox (PN/A) Processes for Energy-efficient Short-cut Nitrogen Removal)

  • 박홍근;유대환
    • 한국물환경학회지
    • /
    • 제34권1호
    • /
    • pp.96-108
    • /
    • 2018
  • Large efforts have recently been made on research and development of sustainable and energy-efficient short-cut nitrogen removal processes owing to strong attention to the energy neutral/positive wastewater treatment system. Anaerobic ammonium oxidizing bacteria (anammox bacteria) have been highlighted since 1990's due to their unique advantages including 60% less energy consumption, nearly 100% reduction for carbon source requirement, and 80% less sludge production. Side-stream short-cut nitrogen removal using anammox bacteria and partial nitritation anammox (PN/A) has been well established, whereas substantial challenges remain to be addressed mainly due to undesired main-stream conditions for anammox bacteria. These include low temperature, low concentrations of ammonia, nitrite, free ammonia, free nitrous acid or a combination of those. In addition, an anammox side-stream nitrogen management is insufficient to reduce overall energy consumption for energy-neutral or energy positive water resource recovery facility (WRRF) and at the same time to comply with nitrogen discharge regulation. This implies the development of the successful main-stream anammox based technology will accelerate a conversion of current wastewater treatment plants to sustainable water and energy recovery facility. This study discusses the status of the research, key mechanisms & interactions of the protagonists in the main-stream PN/A, and control parameters and major challenges in process development.

Termosyphon의 지열채열 성능에 관한 고찰 (A Study on the Characteristics of the Earth Heat Extraction Using Termosyphon)

  • 신현준;서정윤
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.226-233
    • /
    • 1993
  • Thermosyphons are simple devices that can passively transport thermal energy over relatively large distance with little temperature degradation. Especially, the thermosyphon system requires no costly energy input and is completely maintenance free. These attributes permit the use of low grade thermal energy for thermal control of structures including the stabilization of highway foundations. This paper presents the experimental results of the snow melting system in which thermosyphon was utilized to ransfer the earth energy to the pavement to remove snow and ice. The test facility, three earth heated and one unheated test panels, is designed to investigate the variables associated with removing snow and ice from pavement surfaces. The results of these test show that the earth heated panel surface temperature is higher $2{\sim}6^{\circ}C$ than unheated panel when the ambient air temperature is $-7^{\circ}C$. The thermal performance of this earth source thermosyphon system for road heating showed that there was no snow on the heated test panels when the snowfall was 5cm average for the region.

  • PDF