• 제목/요약/키워드: Low-temperature Heat Source

검색결과 280건 처리시간 0.025초

실리카겔을 이용한 흡착식 담수화 시스템 개발 (Development of Adsorption Desalination System Utilizing Silica-gel)

  • 현준호;;이윤준;천원기
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.364-369
    • /
    • 2012
  • The development of solar thermal energy used adsorption desalination technology have been examined as a viable option for supplying clean energy. In this study, the modelling of the main devices for solar thermal energy used and adsorption desalination system was introduced. Silica gel type adsorption desalination system is considered to be a promising low-temperature heat utilization system. The design is divided into three parts. First, the evaporator for the vaporization of the tap water is designed, and then the reactor for the adsorption and release of the steam is designed, followed by the condenser for the condensation of the fresh water is designed. In addition, new features based on the energy balance are also included to design absorption desalination system. In this basic research, One-bed(reactor) adsorption desalination plant that employ a low-temperature solar thermal energy was proposed and experimentally studied. The specific water yield is measured experimentally with respect to the time controlling parameters such as heat source temperatures, coolant temperatures, system switching and half-cycle operational times. Desalination is processes that permeate our daily lives, but It requires substantial energy input, powered either from electricity or from thermal input. From the environmental and sustainability perspecives, innovative thermodynamic cycles are needed to produce the above-mentioned useful effects at a lower specific energy input. This article describes the development of adsorption cycles for the production of desalting effects. We want that this adsorption system can be driven by low temperature heat sources at 60 to $80^{\circ}C$, such as renewable, solar thermal energy.

  • PDF

스프레이 열전달을 이용한 저온도차 스털링 엔진의 실험적 개념 연구 (Experimental Feasibility Study on Low-Temperature Differential Stirling Engines with Water Spray Heat Transfer)

  • 장선준;이윤표;심규호
    • 대한기계학회논문집B
    • /
    • 제38권6호
    • /
    • pp.475-482
    • /
    • 2014
  • 본 연구는 스프레이 열전달을 이용한 저온도차 스털링 엔진의 실험적 개념 연구를 제시한다. 스프레이 열교환기는 노즐을 통하여 엔진 작동 공간에 직접 물을 분사함으로써 엔진 성능을 저해하는 불용 공간을 최소화하고 열전달 효율을 높였다. 직접 구현된 실험 스털링 엔진의 실증 실험은 운전 시점의 기동 특성, 정상 상태의 운전 특성, 엔진의 출력 특성에 대하여 진행하였다. 실험 결과, 열수 유량 증가에 대하여 엔진 기동 시 작동 최소 온도는 감소한 반면, 고온부 온도와 고온부-저온부 온도차는 대체로 일정하였다. 정상 상태 운전의 경우 열수 온도 및 유량 증가에 대하여 작동 주파수는 증가하였다. 엔진 출력은 열수 온도 및 유량 증가에 따라 사이클당 일 및 작동 주파수 증가로 인하여 증가하였다. 본 연구에서 구현된 실험 스털링 엔진은 열수 유량 30 ml/min, 열수 온도 $65^{\circ}C$, 고온부-저온부 온도차 $6^{\circ}C$ 이상에서 엔진 출력 0.05W 수준으로 안정된 기동 및 운전 특성을 보였으며, 향후 출력 증가 및 다양한 적용 연구를 지속할 계획이다.

공원녹지의 토지피복비율과 기온간의 요인분석 (Factor Analysis of the Relation Between Land Cover Ratio of Green Spaces and Temperature)

  • 윤용한;박봉주;김원태;박선영
    • 한국환경과학회지
    • /
    • 제17권5호
    • /
    • pp.485-491
    • /
    • 2008
  • The present study examined the relation between land cover condition and temperature in various types of urban green spaces. The diagram of temperature distribution showed that high-temperature zones are formed around paved areas, and low temperature zone around planted areas and grassy areas. Even in planted areas where low-temperature zones were formed, temperature was different according to hierarchical structure. That is, temperature was relatively low in areas covered with arbor + sub-arbor. With regard to land cover ratio, the increase of planted areas and grassy areas had an effect on the fall of temperature and the effect was higher in order of planted areas and grassy areas. On the contrary, paved areas and bare areas had an effect on the rise of temperature. According to the results of factor analysis, in case of the highest temperature, planted area and grassy area were put together into a factor lowering temperature, paved area and temperature into a factor raising temperature, and bare area alone into a factor of low significance. In case of the lowest temperature, grassy area and bare area were put together into a factor, and the validity of the factor analysis was proved by the analysis of urban heat islands. An increase in the number of trees by height was effective in lowering temperature, and the effect was high in order to arbor and sub-arbor, and the source of coldness in planted area was tall trees.

소형 유기랭킨사이클 시스템 개발 및 작동특성에 관한 연구 (Development of Small-scale Organic Rankine Cycle System and Study on its Operating Characteristics)

  • 윤은구;김현동;윤상열;김경천
    • 대한기계학회논문집B
    • /
    • 제37권10호
    • /
    • pp.919-926
    • /
    • 2013
  • 본 연구에서는 소형 저온 유기랭킨사이클 시스템의 작동특성을 파악하기 위하여 R-245fa를 작동유체로 사용한 소형 ORC 발전 시스템을 설계 및 제작하였고, 다양한 저온의 열원온도에 대한 실험적 연구를 수행하였다. 저온 열원을 모사하기 위하여 최고 $150^{\circ}C$의 물을 공급할 수 있는 110 kW급의 전기저항 히터를 제작하였으며, 컨트롤러를 통해서 다양한 열원 온도 및 유량조건에 대한 실험이 가능하도록 구성하였다. 또한, 상용 공기용 스크롤 압축기를 이용하여 팽창기로 개조하고 동력계 및 동기식 모터와 직접 연결하였다. 로드뱅크 및 PI 제어방식을 사용하여 팽창기의 회전속도에 따른 동일 열원온도 조건에 대한 실험을 각각 수행하였으며, 소형 ORC 시스템의 성능에 영향을 미치는 다양한 인자들에 대하여 분석하고 논의하였다.

첨가제를 첨가한 저온축열물질의 냉각특성에 대한 연구 (A Study on Cooling Characteristics of Low Temperature Thermal Storage Material with Additives)

  • 정낙규;김진흥;정종헌;김창오;강승현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1746-1750
    • /
    • 2004
  • The objective of this study is to investigate the effect of supercooling repression on the clathrate compound by adding additives. For this purpose, phase change temperature and supercooling were measured when additives added to TMA30wt% clathrate for heat source temperature of $-6^{\circ}C$. The experimental results show that the phase change temperature with the chloroform of 0.1wt% is higher by $0.3^{\circ}C$ than TMA30wt% and the supercooling with the surfactant 0.1wt% is reduced by $9.2^{\circ}C$.

  • PDF

열펌프의 정량적 특허기술 분석에 관한 연구 (An Analysis of the Patents for Heat Pumps)

  • 최종민;김용찬;천덕우;심윤희;이상혁;곽재수
    • 설비공학논문집
    • /
    • 제17권9호
    • /
    • pp.808-815
    • /
    • 2005
  • A technical analysis was conducted to predict the development trends for heat pump system. This study was based on submitted patents from 1983 to 2002 in Korea, USA, and Japan. The total number of raw data from the registered database was 19,261 and the obtained data to be analyzed through the filtering process was 5,143. Japan's technical development for the heat pump system was more dominant than the other countries. Approximately $54\%$ of the total patents related with the heat pump system was registered by Japan. The number of patents for the heat pump system registered by Korea was very low in 1980's, but it increased rapidly in 1990's. As a result, the number of patents applied by Korea was $21\%$ of all patents. When the patent was categorized into compression, absorption/ad-sorption, and chemical type, the technology of compression type made up over $80\%$ in each country. Approximately $93\%$ of the patents surveyed in this study was developed for air or water source heat pumps because of easy applications compared with other heat sources. The $89\%$ of all patents was applied by companies when applicants were divided into three groups of company, individual, and the others (national institute, university, and so on).

Absorption cooling R&D in Europe

  • Kuhn, A.;Petersen, S.;Riebow, D.;Sahin, D.;Ziegler, F.
    • 대한설비공학회지:설비저널
    • /
    • 제33권3호
    • /
    • pp.50-57
    • /
    • 2004
  • This article reviews absorption cooling R&D in Europe from the viewpoint of fundamentals, cycle development and applications. The review contains information on R&D, predominantly of public projects in the field of sorption cooling. We report on research which is performed in Europe with some stress on Germany. There is progress in fundamentals, thermodynamic cycle design, and also applications. In the fundamentals part the discussion about thermodynamics, working pairs, and heat and mass transfer is reflected. Today's discussion on thermodynamic cycles is not very strong. Main focus is on special solid sorption cycles, compression­sorption hybrids, and open cycles, In the applications part the chilling business is the main issue. Some interest is given to the improvement of efficiency on and the adaptation to low temperature waste heat use, but the stress is on the use of solar energy as heat source. The area of heat pumping for heating purposes is less prominent but not at all negligible. Finally, industrial heat pumping involves the reverse cycle (heat transformer, heat pump type Ⅱ) also, but there is no significant activity.

  • PDF

스크린 인쇄법에 의해 제작된 유기 박막 트랜지스터용 전극에 관한 연구 (A Study on Contacts for Organic thin-film transistors fabricated by Screen Printing Method)

  • 이미영;남수용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.591-592
    • /
    • 2006
  • We studied about the manufacture of the drain-source contacts for OTFTs(organic thin-film transistors) by using screen printing method. The conductive fillers used Ag and carbon black. The conductive contacts with $100{\mu}m$ of channel length were screen printed on a silicon dioxide gate dielectric layer and, the pentacene semiconductor was deposited via vacuum deposition. As a result of studying various conductive pastes, we could obtain the OTFTs which exhibited field-effect behavior over arrange of drain-source and gate voltages, similar to devices employing deposited Au contacts. By using screen-printing with conductive paste, the contacts are processed at low temperature, thereby facilitating their integration with heat sensitive substrates.

  • PDF

열전발전량에 영향을 미치는 요인과 최적의 열전발전시스템에 관한연구 (A Study for Thermoelectric Generator System And Caused Low Thermoelectric Power)

  • 문채주;정의헌;임정민;박상진;김태곤;김용구
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.68-74
    • /
    • 2008
  • This paper describes the causes and effects that have influence on thermoelectric generation. If heat transfer is unequal to thermoelectric modules, we could not get the maximum thermoelectric power. So, by experiment, we analysed the differences of power generation according to the state of the contact between thermoelectric module and heat source. And with the variation of heat transfer area, the generated power was analysed also. Using the experimental results we proposed a thermoelectric generation system.

  • PDF

태양열 해수담수화를 위한 증발식 MEMS(Multi-Effect-Multi-Stage)담수기 성능 실험 연구 (Experimental Study on Performance of MEMS(Multi-Effect-Multi-Stage) Distiller for Solar Thermal Desalination)

  • 주홍진;전용한;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.91-98
    • /
    • 2013
  • In this study, we have carried out development and performance evaluation of optimized MEMS(Multi-Effect-Multi-Stage) fresh water generator with $7m^2/day$ for solar thermal desalination system. The developed MEMS was composed of high temperature part and low temperature part. This arrangement has the advantage of increasing the availability of solar thermal energy. The MEMS consists of 2 steam generators, 5 evaporators, and 1 condenser. Tubes of heat exchanger used for steam generators, evaporators and condenser were manufactured by corrugated tubes. The performance of the MEMS was tested through in-door experiments, using an electric heater as heat source. The experimental conditions for each parameters were $20^{\circ}C$ for sea water inlet temperature to condenser, $8.16m^2$ /hour sea water inlet volume flow rate, $70^{\circ}C$ for hot water inlet temperature to generator of high temperature part, 3.6 4.8, 6.0 $m^2/hour$ for hot water inlet volume flow rate. As a result, The developed MEMS was required about 85 kW heating source to produce $7m^2/day$ of fresh water. It was analyzed that the performance ratio of MEMS was about 2.6.