• 제목/요약/키워드: Low-temperature Heat Source

검색결과 280건 처리시간 0.026초

포접화합물의 열물성에 미치는 첨가제의 효과 (II) -TMA 물계 포접화합물에 Ethylene Glycol을 첨가한 경우- (The Effects of Additives on the Thermal Properties of a Clathrate Compound (II) -The Case of Ethylene Glycol-)

  • 정낙규;김진흥;김창오;김광일
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.499-505
    • /
    • 2004
  • The objective of this study is to investigate the effect of supercooling repression on the TMA clathrate by adding ethylene glycol. For this purpose, phase change temperature, supercooling, specific heat, latent heat and rate of volume change were measured and evaluated experimentally for heat source temperatures of -6$^{\circ}C$, -7$^{\circ}C$, -8$^{\circ}C$. The results show that supercooling was decreased. Thus the experimental results are expected to be used for the increase of coefficient of performance of low temperature thermal storage system in the building.

PTC와 평판형 태양열집열기의 성능평가 비교 연구 (The Comparative Study on Performance of PTC and Flat-plate Solar Collector)

  • 김인환;허남수;김만석;이정언
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.28-33
    • /
    • 2010
  • Solar collectors to be applied are mainly flat-plate or vacuum tube collector which is used for hot water supply of house because of low heat value and low temperature. There are a necessity to expand applicable scope of solar collector into the industrial process heat source and air conditioner for coping with renewable energy policy of government and industrial trend. This study is to analysis the performance of PTC solar collector of concentrating type and flat-plate of non-concentrating. For this, temperature difference and heating value as insolation of air outside is measured from these two collectors mounted on 2-axial solar tracking system. It is investigated that temperature profile obtained from PTC solar collector is uniform and collecting heat per unit area is 6.8kcal/$m^2$ min which is about 3 times with compare to flat-plate collector of 2kcal/$m^2$min. Also the amount of heat to be produced from PTC solar collector is 3 Mcal/$m^2$ which is about 2 times with compare to flat-plate collector of 1.5Mcal/$m^2$ as a result of operating these two collectors during one month. Therefore, it is obtained that heat collecting performance of PTC solar collector is superior to flat-plate.

A SMALL MODULAR REACTOR DESIGN FOR MULTIPLE ENERGY APPLICATIONS: HTR50S

  • Yan, X.;Tachibana, Y.;Ohashi, H.;Sato, H.;Tazawa, Y.;Kunitomi, K.
    • Nuclear Engineering and Technology
    • /
    • 제45권3호
    • /
    • pp.401-414
    • /
    • 2013
  • HTR50S is a small modular reactor system based on HTGR. It is designed for a triad of applications to be implemented in successive stages. In the first stage, a base plant for heat and power is constructed of the fuel proven in JAEA's $950^{\circ}C$, 30MWt test reactor HTTR and a conventional steam turbine to minimize development risk. While the outlet temperature is lowered to $750^{\circ}C$ for the steam turbine, thermal power is raised to 50MWt by enabling 40% greater power density in 20% taller core than the HTTR. However the fuel temperature limit and reactor pressure vessel diameter are kept. In second stage, a new fuel that is currently under development at JAEA will allow the core outlet temperature to be raised to $900^{\circ}C$ for the purpose of demonstrating more efficient gas turbine power generation and high temperature heat supply. The third stage adds a demonstration of nuclear-heated hydrogen production by a thermochemical process. A licensing approach to coupling high temperature industrial process to nuclear reactor will be developed. The low initial risk and the high longer-term potential for performance expansion attract development of the HTR50S as a multipurpose industrial or distributed energy source.

유기랭킨사이클로 구동되는 증기압축냉동사이클의 엑서지 해석 (Exergy Analysis of Vapor Compression Cycle Driven by Organic Rankine Cycle)

  • 김경훈
    • 대한기계학회논문집B
    • /
    • 제37권12호
    • /
    • pp.1137-1145
    • /
    • 2013
  • 본 연구에서는 열 구동 냉동사이클로서 유기 랭킨사이클 (ORC)과 증기 압축 냉동사이클(VCC)의 복합 사이클에 대한 엑서지 해석을 수행하였다. 시스템의 열원으로는 다양한 재생 에너지 열원이나 산업체에서의 폐열 등 현열 형태의 저온 열원을 고려하였으며 작동유체로서 R143a, R22, R134a, 프로판, 이소부탄, 부탄, R245fa 및 R123 등 여덟가지 작동유체들을 고려하였다. 터빈 입구 압력의 변화나 작동유체의 종류에 따라 시스템의 COP 나 엑서지 효율은 물론 시스템의 각 요소에서의 엑서지 파괴 (아너지)에 미치는 다양한 영향에 대해 분석하고 논의하였다. 해석 결과는 주어진 열원 온도에 대해 시스템에서 가장 엑서지 파괴가 큰 구성 요소는 터빈 입구 압력과 작동유체에 따라 민감하게 변화하는 사실을 보여준다.

재생형 증발식 냉각기를 이용한 제습 냉방시스템의 성능해석 (Cycle Simulation of a Desiccant Cooling System with a Regenerative Evaporative Cooler)

  • 이재완;이대영;강병하
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.566-573
    • /
    • 2004
  • Comparison of the cooling performance is provided between the desiccant cool-ing systems incorporating a direct evaporative cooler and a regenerative evaporative cooler, respectively. Cycle simulation is conducted, and the cooling capacity and COP are evaluated at various temperature and humidity conditions. The COP of the system with a regenerative evaporative cooler and the regeneration temperature of 6$0^{\circ}C$ is evaluated 0.65 at the outdoor air condition of 35$^{\circ}C$ and 40% RH. This value is found about 3.4 times larger than that of the system with a direct evaporative cooler. Furthermore, incorporating a regenerative evaporative cooler eliminates the need for deep dehumidification in a desiccant dehumidifier that is necessary to achieve low air temperature in the system with a direct evaporative cooler. Subsequently, the regenerative evaporative cooler enables the use of low temperature heat source to regenerate the dehumidifier permitting the desiccant cooling system more beneficial compared with other thermal driven air conditioners.

저온축열물질의 열물성에 미치는 첨가제의 영향 (The Effects of Additives on the Thermal Properties of a Low Temperature Thermal Storage Material)

  • 강승현;김진홍;정낙규;김창오
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1165-1170
    • /
    • 2004
  • The purpose of this study is to investigate the supercooling improvement of TMA30wt% clathrate when the chloroform is added to it. For this purpose, phase change temperature and supercooling are measured and evaluated experimentally in heat source of $-7^{/circ}C$. The results show that phase change temperature and supercooling are improved. From the results, this research can provide and important data for the low temperature thermal storage.

  • PDF

Effect of Heat-Treated Temperature on Surface Crystal Structure and Catalytic Activity of ACF/ZnO Composite under Ultraviolet Irradiation and Ultrasonication

  • Zhang, Kan;Oh, Won-Chun
    • 한국세라믹학회지
    • /
    • 제47권2호
    • /
    • pp.136-141
    • /
    • 2010
  • ACF/ZnO photocatalyst was synthesized by a sol-gel method using activated carbon fiber (ACF) and Zn $(NO_3)_2$ as precursors. Samples were characterized by Brunauer-Emmett-Teller measurements (BET), scanning electron microscope (SEM), X-ray diffraction (XRD), and energy dispersive X-ray (EDX). The XRD results showed that ACF/ZnO composites only included a hexagonal phase by heat-treated temperature at $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, and $700^{\circ}C$. The SEM analysis revealed that the ACF/ZnO composites did not exhibit any morphological changes of the catalyst surface according to the different heat-treated temperatures. The photocatalytic activity of the samples was tested for degradation of methylene blue (MB) solutions under ultraviolet (UV) light and ultrasonication respectively. The results showed that the photocatalytic activity of ACF/ZnO composites heat-treated at $500^{\circ}C$ was higher than other samples, which is ascribed to the fine distribution of ZnO particles on the surface of the ACF. In addition, an ultrasound of low power (50 W) was used as an irradiation source to successfully induce ACF/ZnO composites to perform sonocatalytic degradation of MB. Results indicated that the sonocatalytic method in the presence of ACF/ZnO composites is an advisable choice for the treatments of organic dyes.

LNG 냉열을 이용하는 유기랭킨사이클(ORC)의 열역학적 성능 특성 (Thermodynamic Performance Characteristics of Organic Rankine Cycle (ORC) using LNG Cold Energy)

  • 김경훈;하종만;김경천
    • 한국가스학회지
    • /
    • 제18권2호
    • /
    • pp.41-47
    • /
    • 2014
  • 본 논문에서는 유기랭킨사이클과 LNG 사이클로 구성된 복합사이클의 열역학적 성능 해석을 수행한다. 이 복합사이클에서는 현열 형태의 저등급 폐열을 사용하며 LNG 냉열은 열싱크 뿐 아니라 동력 생산에도 사용된다. 시스템의 성능에 대한 터빈입구압력, 응축온도, 열원온도 등 주 파라미터들의 영향을 상세하게 분석한다. 시뮬레이션 결과는 이 복합시스템은 LNG 냉에너지를 사용하지 않은 일반의 ORC에 비해 현저하게 성능이 개선될 수 있음을 보여준다.

암모니아-물 흡수식 시스템에서 유하액막식 발생기의 해석 (Analysis of Falling-film Generator in Ammonia-water Absorption System)

  • 김병주;손병후;구기갑
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.422-430
    • /
    • 2001
  • In the present study, an evaporative generation process of ammonia-water solution film on the vertical plate was analysed. For the utilization of waste heat, hot water of low temperature was used as the heat source. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. Counter-current solution-vapor flow resulted in the refrigerant vapor of the higher ammonia concentration than that of co-current flow. Eve the rectification of refrigerant vapor was observed near the inlet of solution film in counter-current flow. For the optimum operation of generator using hot water, numerical experiments, based on the heat exchange and generation efficiencies. revealed the inter-relationships among the Reynolds number of the solution film and hot water, and the length of generator. Enhancement of heat and mass transport in the solution film was found to be very effective for the improvement of generation performance, especially at high solution flow rate.

  • PDF

시설원예용 수평형 지열히트펌프의 난방 성능 해석 (Heating Performance of Horizontal Geothermal Heat Pump System for Protected Horticulture)

  • 강연구;유영선;강금춘;백이;김영중
    • Journal of Biosystems Engineering
    • /
    • 제32권1호
    • /
    • pp.30-36
    • /
    • 2007
  • Geothermal heat pump systems use the earth as a heat source in heating mode and a heat sink in cooling mode. These systems can be used for heating or cooling systems in farm facilities such as greenhouses for protected horticulture, cattle sheds, mushroom house, etc. A horizontal type means that a geothermal heat exchanger is laid in the trench buried in 1.2 to 1.8 m depth. Because a horizontal type has advantages of low installation, operation and maintenance costs compared to a vertical type, it is easy to be adopted to agriculture. In this study, to heat and cool farm facilities and obtain basic data for practical application of horizontal geothermal heat pump systems in agriculture, a horizontal geothermal heat pump system of 10 RT scale was installed in greenhouse. Heating performance of this system was estimated. The horizontal geothermal heat pump used in this study had heating COP of 4.57 at soil temperature of 14$^{\circ}C$ for depth of 1.75m and heating COP of 3.75 at soil temperature of 7$^{\circ}C$ for the same depth. The stratification of water temperature in heat tank appeared during the whole heat rejection period.