• Title/Summary/Keyword: Low-resolution image

Search Result 866, Processing Time 0.032 seconds

Inplementation of flooding simulation in coastal area based on 3D satellite images and Web GIS

  • Jo, Myung-Hee;Park, Hyeon-Cheol;Kim, Hyoung-Sub;Choi, Yong-Ki
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.166-169
    • /
    • 2006
  • Our country's coast is vulnerable area to natural disaster which the repetitive damages occur every year including a loss of lives, the damage of facilities and erosion mostly except for the east coast because of a typhoon, tidal waves, sea water overflowing by topographic structure of low-lying gentle slope and shallow sea. However, as for prevention of natural disaster occurring every year, the situation is that it's centered on the restorationcentered measures and the general disaster prevention research to minimize damages at the time of disaster occurrence is insufficient. This study intendedlop t to devehe techniques possible for real time sampling of damage prediction areas on Web in order to support decision making for damage prevention and establishment of disaster prevention policy. For this, the thematic map was produced related to disaster based on high-resolution satellite picture, and the environmental DB similar to real world was constructed through topographic construction of three-dimension integrating the parts of land and the sea. In addition, the system was developed possible for the expression of damageable regions by real time grasp of dangerous regions at the time of disaster occurrence through over flowing simulation of three-dimension, and it's intended to prepare a basis to minimize damages to disaster situations through it.

  • PDF

Laser scanning unit with plastic f$\theta$ lenses featuring high resolution (600DPI용 플라스틱 f$\theta$렌즈가 실장된 Laser Scanning Unit 의 측정 및 평가)

  • 임천석
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.364-368
    • /
    • 1999
  • We investigate the evaluation items of LSU (Laser Scanning Unit), such as beam size, f$\theta$ characteristics, linearity, skew and bow, optical power ratio between image height of 0mm and $\pm$108 mm, pitch error, Jitter and shift of printing position. Through the measurement of LSU using BSH (Beam Scan Head) installed on LMC (Linear Motion Controller) which moves linearly within the whole scanning range (-108 mm~+108 mm), we can ascertain plastic f$\theta$ lenses, which are manufactured by TVLP (Two-step Variable Low Pressure) molding method, to satisfy 600DPI(Dots Per Inch) performance.

  • PDF

Verification of Launch Vibration and Shock Isolation Performance for Spaceborne Compressor Vibration Isolator with SMA Mesh Washer (형상기억합금 메쉬 와셔를 이용한 우주용 냉각기 진동절연기의 발사 진동 및 충격 저감 성능검증)

  • Lee, Myeong-Jae;Han, Je-Heon;Oh, Hyun-Ung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.517-524
    • /
    • 2014
  • Micro-vibration induced by on-board equipments such as fly-wheel and cryogenic cooler with mechanical moving parts affects the image quality of high-resolution observation satellite. Micro-vibration isolation system has been widely used for enhancing the pointing performance of observation satellites. In general, the micro-vibration isolation system requires a launch locking mechanism additionally to guarantee the structural safety of mission payloads supported by the isolation system with low stiffness under launch environment. In this study, we propose a passive launch and on-orbit vibration isolation system using shape memory alloy mesh washers for the micro-vibration isolation of spaceborne compressor, which does not require the additional launch locking mechanism. The basic characteristics of the isolator were measured in static and free vibration tests of the isolator, and a simple equivalent model of the isolator was proposed. The effectiveness of the isolator design in a launch environment was demonstrated through sine vibration, random vibration and shock tests.

Applicability Evaluation of Agricultural Subsidies Inspection Using Unmanned Aerial Vehicle (무인항공기를 이용한 직불제 이행점검 적용성 평가)

  • Park, Jin Ki;Park, Jong Hwa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.5
    • /
    • pp.29-37
    • /
    • 2016
  • Unmanned Aerial Vehicle (UAV) have several advantages over conventional remote sensing techniques. UAV can acquire high-resolution images quickly and repeatedly with a comparatively lower flight altitude i.e. 80~400 m nullifying the effect of extreme weather and cloud. This study discussed the use of low cost-effective UAV based remote sensing application in inspection of agricultural subsidy. The study area accrue $60.5km^2$ of Buljeong-myeon, Goesan-gun, Chungbuk in South Korea. UAV image acquired 25 times from July 25 to August 11, 2015 for 3 days. It is observed that almost 81.1 % (3,571 of 4,410 parcels) parcels are truthful whereas some parcels are incorrect or fraudulent. Surveying with UAV for agricultural subsidy instead of field stuff can reduce the required time as much as 64.8 % (19 of 54 days). Therefore, it can contribute significantly in speedy and more accurate processing of grant application and can end unfair receipt of the grant which in turn will improve customer satisfaction.

A progressive study of the sausage mode wave on the pore: the pore-selection technique

  • Cho, Il-Hyun;Kim, Yeon-Han;Cho, Kyung-Suk;Bong, Su-Chan;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.66.2-66.2
    • /
    • 2013
  • In this study, we present a pore-selection technique to estimate the size of pore. The estimation of the size of pore is important to examine the temporal evolution of size itself and corresponding intensity. The size of pore is typically estimated by applying the intensity threshold technique to the fixed box which contains the entire pore. The typical method has disadvantages in the following circumstances; there are small features near the pore or the image has low spatial resolution. In the former, it is difficult to define a box containing the pore only, excluding the small features near the pore. In the latter, the background and threshold intensity are insignificant due to the insufficient number of pixel in the box. To avoid these difficulties, we use a pore-selection technique which is simply based on the measurement of distances from the pore center. In addition, we will discuss the advantage of the technique for the imaging spectrograph data like the NST FISS.

  • PDF

A Framework for Real Time Vehicle Pose Estimation based on synthetic method of obtaining 2D-to-3D Point Correspondence

  • Yun, Sergey;Jeon, Moongu
    • Annual Conference of KIPS
    • /
    • 2014.04a
    • /
    • pp.904-907
    • /
    • 2014
  • In this work we present a robust and fast approach to estimate 3D vehicle pose that can provide results under a specific traffic surveillance conditions. Such limitations are expressed by single fixed CCTV camera that is located relatively high above the ground, its pitch axes is parallel to the reference plane and the camera focus assumed to be known. The benefit of our framework that it does not require prior training, camera calibration and does not heavily rely on 3D model shape as most common technics do. Also it deals with a bad shape condition of the objects as we focused on low resolution surveillance scenes. Pose estimation task is presented as PnP problem to solve it we use well known "POSIT" algorithm [1]. In order to use this algorithm at least 4 non coplanar point's correspondence is required. To find such we propose a set of techniques based on model and scene geometry. Our framework can be applied in real time video sequence. Results for estimated vehicle pose are shown in real image scene.

Connection Management Scheme using Mobile Agent System

  • Lim, Hee-Kyoung;Bae, Sang-Hyun;Lee, Kwang-Ok
    • Journal of Integrative Natural Science
    • /
    • v.11 no.4
    • /
    • pp.192-196
    • /
    • 2018
  • The mobile agent paradigm can be exploited in a variety of ways, ranging from low-level system administration tasks to middle ware to user-level applications. Mobile agents can be useful in building middle-ware services such as active mail systems, distributed collaboration systems, etc. An active mail message is a program that interacts with its recipient using a multimedia interface, and adapts the interaction session based on the recipient's responses. The mobile agent paradigm is well suitable to this type of application, since it can carry a sender-defined session protocol along with the multimedia message. Mobile agent communication is possible via method invocation on virtual references. Agents can make synchronous, one-way, or future-reply type invocations. Multicasting is possible, since agents can be aggregated hierarchically into groups. A simple check-pointing facility has also been implemented. Another proposed solution is to use multi agent computer systems to access, filter, evaluate, and integrate this information. We will present the overall architectural framework, our agent design commitments, and agent architecture to enable the above characteristics. Besides, the each information needed a mobile agent system such as text, graphic, image, audio and video etc, constructed a great capacity multimedia database system. However, they have problems in establishing connections over multiple subnetworks, such as no end-to-end connections, transmission delay due to ATM address resolution, no QoS protocols. We propose a new connection management scheme in the thesis to improve the connection management involved of mobile agent systems.

Measurement of RBC (red blood cell) deformability using 3D Printed Chip combined with Smartphone (스마트 폰 기반 3D 프린팅 칩을 이용한 적혈구 변형성 측정)

  • Lee, Suhwan;Hong, Hyeonji;Yeom, Eunseop;Song, Jae Min
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.103-108
    • /
    • 2020
  • RBC (red blood cell) deformability is one of factors inducing blood shear thinning effect. Reduction of RBC deformability increases blood viscosity in high shear region. In this study, 3D printed chip with proper distribution of wall shear rate (WSR) was proposed to measure RBC deformability of blood samples. To fabricate 3D printed chip, the design of 3D printed chip determined through numerical simulation was modified based on the resolution of the 3D printer. For the estimation of pressure drop in the 3D printed chip, two bypass outlets with low and high WSR are exposed to atmospheric pressure through the needles. By positioning the outlet of needles in the gravity direction, the formation of droplets at bypass outlets can be captured by smartphone. Through image processing and fast Fourier transform (FFT) analysis, the frequency of droplet formation was analyzed. Since the frequency of droplet formation is related with the pressure at bypass, high pressure drop caused by reduction of RBC deformability can be estimated by monitoring the formation of blood droplets using the smartphone.

Assessment of DVC measurement uncertainty on GFRPs with various fiber architectures

  • Bartulovic, Ante;Tomicevic, Zvonimir;Bubalo, Ante;Hild, Francois
    • Coupled systems mechanics
    • /
    • v.11 no.1
    • /
    • pp.15-32
    • /
    • 2022
  • The comprehensive understanding of the fiber reinforced polymer behavior requires the use of advanced non-destructive testing methods due to its heterogeneous microstructure and anisotropic mechanical proprieties. In addition, the material response under load is strongly associated with manufacturing defects (e.g., voids, inclusions, fiber misalignment, debonds, improper cure and delamination). Such imperfections and microstructures induce various damage mechanisms arising at different scales before macrocracks are formed. The origin of damage phenomena can only be fully understood with the access to underlying microstructural features. This makes X-ray Computed Tomography an appropriate imaging tool to capture changes in the bulk of fibrous materials. Moreover, Digital Volume Correlation (DVC) can be used to measure kinematic fields induced by various loading histories. The correlation technique relies on image contrast induced by microstructures. Fibrous composites can be reinforced by different fiber architectures that may lead to poor natural contrast. Hence, a priori analyses need to be performed to assess the corresponding DVC measurement uncertainties. This study aimed to evaluate measurement resolutions of global and regularized DVC for glass fiber reinforced polymers with different fiber architectures. The measurement uncertainties were evaluated with respect to element size and regularization lengths. Even though FE-based DVC could not reach the recommended displacement uncertainty with low spatial resolution, regularized DVC enabled for the use of fine meshes when applying appropriate regularization.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF