• 제목/요약/키워드: Low-power software

검색결과 399건 처리시간 0.029초

복합발전 적용을 위한 1kW급 수평축 풍력터빈 유동해석 (Flow Analysis on a 1kW-class Horizontal Axis Wind Turbine Blade for Hybrid Power Generation System)

  • 이준용;최낙준;최영도
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.60.2-60.2
    • /
    • 2011
  • This study is to develop a 1kW-class small wind turbine blade which will be applicable to relatively low speed regions. For this blade, a high efficiency wind turbine blade is designed and a light and low cost composite structure blade is adopted considering fatigue life. In this study, shape design of 1kW-class small wind turbine blade for hybrid power generation system is carried out by BEMT(blade element momentum theory). X-FOIL open software was used to acquire lift and drag coefficients of the 2D airfoils used in power prediction procedure. Moreover, pressure and velocity distributions are investigated according to TSR by CFD analysis.

  • PDF

Design and Implementation of a Microwave Motion Detector with Low Power Consumption

  • Sohn, Surg-Won
    • 한국컴퓨터정보학회논문지
    • /
    • 제20권7호
    • /
    • pp.57-64
    • /
    • 2015
  • In this paper, we propose a design of microwave motion detector using X-band doppler radar sensor to minimize the power consumption. To minimize the power consumption and implement battery operated system, pulse input with 2 KHz, 4% duty cycle is exerted on the doppler radar sensor. In order to simplify the process of working with ATmega2560 microcontroller unit, Arduino compatible board is designed and implemented. Arduino is open source hardware and many library software is published as open source tools. Smartphone app is also proposed and designed as a real-time user interface of the motion detector. The SQLite database on the Android mobile operating system is used for recording raw data of motion detection for post-processing job, such as fast Fourier transform (FFT). Bluetooth interface module is implemented on the motion detection board as a wireless communication interface to the smartphone. The speed of human movement is identified by post-processing FFT.

HVDC용 사이리스터 소자의 전기적 특성 simulation 연구 (Electrical characteristics simulation of thyristor devices for HVDC transmission)

  • 김상철;서길수;김은동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1559-1561
    • /
    • 2003
  • In northeast Asia, there will be several important HVDC transmission lines to be established in Korea and China for perspective electric network market. 5500V 4-inches High voltage thyristor can be used in the DC transmission and distribution of electric power system. In this application, many thyristors are connected in series for each thyristor valves. Therefore, the required low reverse-recovery charge QRR and low on-state voltage drop $V_{TM}$ for such thyristor is necessary to this application. In our work, the on-state and off-state voltage performance was simulated by commercial simulation software.

  • PDF

송전선과 분전반 모선으로부터 발생하는 극저주파 자기장 저감을 위한 연구 (Study on minimizing Extremely-Low-Frequency magnetic fields around power cables and busbars)

  • 로우밍;정기우;김동훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.88-90
    • /
    • 2009
  • Extremely-Low-Frequency(ELF) magnetic fields are generated around power cables and bus bars in power systems. Such the stray fields may cause disturbances to nearby electronic apparatus and affect even human health. In order to seeking out a proper way to reducing the fields, the first thing to do is to accurately predict field distribution around analysis models of interest. Then, optimization techniques should be applied for finding a more improved design than the initial one. To achieve this goal, commercial electromagnetic software, MagNet, is combined with evolution strategy algorithm. For verification of the proposed method, three-phase power line cables and busbar systems have been tested.

  • PDF

Energy Management of a Grid-connected High Power Energy Recovery Battery Testing System

  • Zhang, Ke;Long, Bo;Yoo, Cheol-Jung;Noh, Hye-Min;Chang, Young-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.839-847
    • /
    • 2016
  • Energy recovery battery testing systems (ERBTS) have been widely used in battery manufactures. All the ERBTS are connected in parallel which forms a special and complicated micro-grid system, which has the shortcomings of low energy recovery efficiency, complex grid-connected control algorithms issues for islanded detection, and complicated power circuit topology issues. To solve those shortcomings, a DC micro-grid system is proposed, the released testing energy has the priority to be reutilized between various testing system within the local grid, Compared to conventional scheme, the proposed system has the merits of a simplified power circuit topology, no needs for synchronous control, and much higher testing efficiency. The testing energy can be cycle-used inside the local micro-grid. The additional energy can be recovered to AC-grid. Numerous experimental comparison results between conventional and proposed scheme are provided to demonstrate the validity and effectiveness of the proposed technique.

Rack-Level DC Power Solution for Volume Servers

  • Kwon, Won-Ok;Seo, Hae-Moon;Choi, Pyung
    • ETRI Journal
    • /
    • 제32권6호
    • /
    • pp.940-949
    • /
    • 2010
  • Rack-level DC power supply is the optimal technology for providing DC power to a volume server without any power infrastructure changes in an existing AC data center. In this paper, we propose a smartly controllable and monitorable DC rack power system. The proposed system improves power efficiency by changing the power distribution architecture of a conventional method in the rack. We developed an optimal power control method in multipower modules to provide high efficiency at low loads. In addition, the proposed system provides real-time web monitoring of the rack power and environment around a rack. In our experiments, the proposed system improved the power efficiency by over 10% compared to an AC power system providing N+1 redundant power and power monitoring.

셋톱박스의 에너지 효율 개선에 관한 연구 (Study on Improving Energy-Efficiency of Set-top Box)

  • 이상학;윤정미
    • 정보처리학회논문지D
    • /
    • 제18D권3호
    • /
    • pp.197-204
    • /
    • 2011
  • 방송 신호를 수신하여 TV 등의 디스플레이 장치로 전달하는 셋톱박스는 다른 가전과는 다르게 대기모드, 즉 저전력모드가 존재하지 않는다. 이는 기술적 제약과 운용상의 이유로 인한 것이다. 현재 셋톱박스의 전원을 리모컨으로 끄면 방송을 시청하는 온모드 대비 80~90%의 높은 소비전력을 보인다. 이는 1W 미만으로 동작하는 다른 가전에 비해 월등히 높은 것이다. 국내 및 해외 선진국들은 셋톱박스의 에너지 효율을 높이고자 하는 정책을 시행하고 있다. 본 논문에서는 셋톱박스의 에너지 효율을 개선하고자 저전력 셋톱박스를 설계하고 진행 중인 개발에 대해 기술한다. 저전력 모드를 지원하는 SoC, 전원 모드를 구분하여 동작하도록 하는 시스템 하드웨어 및 소프트웨어, 그리고 방송사와의 연동을 통한 전원관리를 이루는 미들웨어 등이 핵심 개발 내용이다. 그리고 이를 통해 이룰 수 있는 에너지 소비 절감 효과를 보인다.

MSP430 기반 저전력 뇌 신경자극기 S/W 설계 및 구현 (Design and Implementation of Low-power Neuromodulation S/W based on MSP430)

  • 홍상표;권성호;심현민;이상민
    • 전자공학회논문지
    • /
    • 제53권7호
    • /
    • pp.110-120
    • /
    • 2016
  • 인체 삽입형 뇌 신경자극기는 소비전력에 있어서 효율적인 구조로 설계되어야 한다. 이들 자극신호는 파형이 단순하고, MCU(micro controller unit)의 대기시간은 실행시간보다 훨씬 긴 특성을 가짐에도 불구하고, 이러한 특성을 고려한 저전력 설계가 되어 있지 않다. 본 논문에서는 자극신호 특성에 기반하는 저전력 알고리즘을 제안한다. 또한 뇌 신경자극기 S/W, NMS(neuro modulation simulation)의 설계 및 구현 결과도 제시한다. 저전력 알고리즘 구현을 위해, 기존 뇌 신경자극기 프로그램의 함수별 수행(running) 시간을 분석하여, 실행(execution) 시간과 대기(waiting) 시간을 도출하였다. 그리고 AM-LPM(active mode-low power mode) 전환시간을 추정하여 저전력 알고리즘 구현에 반영하였다. 본 논문에서 제안하는 저전력 알고리즘은 자극신호의 특성을 이용하여 출력을 다수의 구간으로 분할하고, MCU를 구간별 AM 또는 LPM으로 운용한다. 제안하는 알고리즘의 검증을 위해, 외부 제어프로그램을 개발하여 알고리즘의 동작상태를 확인하였고, 오실로스코프를 이용하여 출력신호의 정확성을 확인하였다. 검증 결과, 제안하는 저전력 알고리즘을 적용할 경우, 기존 뇌 신경자극기 대비 소모전류를 76.31% 감소시킴을 확인 할 수 있었다.

성능 저하 식별을 통한 저전력 개선용 코드 가시화 방법 (Code Visualization Approach for Low level Power Improvement via Identifying Performance Dissipation)

  • 안현식;박보경;김영철;김기두
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제9권10호
    • /
    • pp.213-220
    • /
    • 2020
  • 높은 사양이 필요한 하드웨어 기반의 모바일 및 IoT 임베디드 시스템은 저전력과 성능에 중요한 이슈를 갖고 있다. 이는 전력 소비로 발열량 증가 및 기기의 수명 단축 문제가 발생된다. 이러한 환경에서 소프트웨어도 제한된 전력, 메모리 등에서 안정적인 동작을 수행해야하므로 디바이스의 소비전력이 증가한다. 이를 해결하고자, 코드 관점에서 성능을 저하시키는 모듈을 식별하고, 그 모듈의 전력 최소화를 통한 성능 개선 가시화 방법을 제안한다. 이는 코드 가시화를 통해 복잡한 모듈(특히 Cyclomatic complexity, Coupling & Cohesion)을 식별하고, 저전력 코드 패턴화와 성능 코드를 간결화 한다. 이런 코드로 소비전력을 감소 및 성능 개선 함으로써 코드의 품질을 최적화 할 수 있다.

Energy Balance and Power Performance Analysis for Satellite in Low Earth Orbit

  • Jang, Sung-Soo;Kim, Sung-Hoon;Lee, Sang-Ryool;Choi, Jae-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권3호
    • /
    • pp.253-262
    • /
    • 2010
  • The electrical power system (EPS) of Korean satellites in low-earth-orbit is designed to achieve energy balance based on a one-orbit mission scenario. This means that the battery has to be fully charged at the end of a one-orbit mission. To provide the maximum solar array (SA) power generation, the peak power tracking (PPT) method has been developed for a spacecraft power system. The PPT is operated by a software algorithm, which tracks the peak power of the SA and ensures the battery is fully charged in one orbit. The EPS should be designed to avoid the stress of electronics in order to handle the main bus power from the SA power. This paper summarizes the results of energy balance to achieve optimal power sizing and the actual trend analysis of EPS performance in orbit. It describes the results of required power for the satellite operation in the worst power conditions at the end-of-life, the methods and input data used in the energy balance, and the case study of energy balance analyses for the normal operation in orbit. Both 10:35 AM and 10:50 AM crossing times are considered, so the power performance in each case is analyzed with the satellite roll maneuver according to the payload operation concept. In addition, the data transmission to the Korea Ground Station during eclipse is investigated at the local-time-ascending-node of 11:00 AM to assess the greatest battery depth-of-discharge in normal operation.