• Title/Summary/Keyword: Low-power System

Search Result 5,551, Processing Time 0.032 seconds

An Investigation on Operating Characteristics of the Closed Cycle System Using High Pressure Diesel Engine (고압 디젤엔진을 이용한 폐회로 시스템의 운전특성에 관한 고찰)

  • 김인교;박신배
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.65-72
    • /
    • 2002
  • The closed cycle diesel system is operated in closed circuit system where there is non air breathing with working fluid consists of combination of oxygen, argon and recycled exhaust gas far obtaining underwater or underground power sources. Experimental apparatus using the MTU8V183SE92 high pressurized engine adapted for closed cycle running, capable of operating at the system pressure of maximum 5 bar is constructed with ACAP as data acquisition system in order to operate equally in the open cycle in surface or the closed cycle in submerged conditions. The general features and the characteristics of combustion of HP(high pressure) diesel engine, specially designed and manufactured only for CCDE, are investigated. The test results of performance of HP diesel engine in closed cycle system are presented with respect to power and boost pressure and compared with those of low pressure diesel engine. The oxygen concentration and specific heat ratio are investigated with its deviation

Study on Low Pressure Loop EGR System for Heavy-duty Diesel Engine to Meet EURO-5 NOx Regulation (LPL EGR System 적용 대형 디젤엔진의 EURO-5 NOx 규제대응에 관한 연구)

  • Lee, K.S.;Baek, M.Y.;Park, H.B.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.12-17
    • /
    • 2007
  • Recently, many small and medium size diesel vehicles have been equipped with turbocharger and EGR system to get high performance and reduce $NO_x$ emissions but its application to heavy-duty diesel engine is not common yet. In this work, the simulation model for EURO-3 engine was developed using WAVE and then its performance and emission level were verified by comparing with experimental results. The possibility of current EURO-3 engine equipped with LPL EGR system which would be satisfied the EURO-5 regulation are examined. ESC 13 mode was chosen as the primary engine test mode, and the injection timing and fuel quantity were changed to compensate the lost engine performance caused by EGR. The system developed in this study shows that the current EURO-3 engine could satisfy EURO-5 $NO_x$ regulation by applying LPL EGR.

  • PDF

Performance and Safety Analysis of Marine Solid Oxide Fuel Cell and Gas Turbine Hybrid Power System (under Conditions of Turbine Cooling and Constant TIT) (선박동력용 SOFC/GT 하이브리드시스템의 성능 및 안전성 해석 (터빈 냉각 및 TIT 일정 조건을 중심으로))

  • Kim, Myoung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.484-496
    • /
    • 2009
  • The strengthened regulations for atmospheric emissions from ships like MARPOL Annex VI have caused a necessity of new, alternative power system in ships for the low pollutant emissions and the high energy efficiency. This paper attempts to investigate the configuration of SOFC/GT hybrid power system for LNG tanker taking into account the safety and to analyze the influence of design parameters on the system performance. The simulation results provide the basic data for the design and efficiency improvement of SOFC/GT hybrid system and indicate the guidelines for the safe system operation.

Removal of Volatile Organic Compounds Using a Plasma Assisted Biotrickling System (플라즈마를 결합한 바이오 트리클링 시스템에 의한 휘발성 유기물질의 제거)

  • Kim, Hak-Joon;Han, Bang-Woo;Kim, Yong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.727-733
    • /
    • 2007
  • In this study, a newly developed biotrickling system, combined with a non-thermal plasma reactor, was investigated to effectively treat gaseous contaminants such as VOCs (Volatile Organic Compounds). Three kinds of non-thermal plasmas (NTPs) such as a rod type dielectric barrier discharge (DBD) plasma, a packed bead type DBD plasma and a gliding arc (GA) plasma, were tested and compared in terms of power consumption. The rod type DBD plasma was selected as one for integration with biotrickling system due to its relatively high VOC removal efficiency, low power consumption and low pressure drop. Toluene and xylene as representatives of VOCs were used as test gases. The experiment results showed that the efficiency of biotrickling system was especially very low at the high gas concentration and high flow rate and the removal efficiencies of VOCs were considerably enhanced in the biotrickling system, when the DBD plasma was worked in front of that even at the high gas concentration and high flow rate.

On Determining the Optimal Amount of Barbour Tagboat (항내 예선의 적정규모 결정에 관하여)

  • Park Chang-H;Woo Byung-Goo;Lee Cheol-Yeong
    • Journal of Korean Port Research
    • /
    • v.2 no.1
    • /
    • pp.75-106
    • /
    • 1988
  • As port transport system consists of subsystems such as navigation system, cargo handling system, storage system, inland transport system, and Management and Information system, the productivity of this system is determined by the minimum level of subsystem. From the viewpoint of elaborating the efficiency of integrated system, it is valuable to determine the optimal level of harbour tug boat which is the most important factor of navigation system. This paper treats the optimal amount of harbour tug boat by simulation, and applied to Pusan port. In the course of simulation, an emperical formula is introduced for determining the Horse Power (HP) of tug boat by the ship's gross tonnage (G/T) refering to the cases of various ports of other countries, that is ; $Y=9.96X^{0.6}+569$. X : The gross tonnage of vessel (G/T). Y : The Horse Power (HP) of tug boat. The results of the simulation are summarized as follows ; 1) In 1987, three or four low-powered harbour tug boats, five mid-powered harbour tug boats and four high-powered harbour tug boats are necessary in the mean level. But, five or seven low-powered harbour tug boats, ten mid-powered harbour tug boats and eight high-powered harbour tug boats are necessary lest delay should occur at all. 2) In 1992, 1lee or four low-powered harbour tug boats, six mid-powered harbour tug boats and seven high-powered harbour tug boats are estimated and be necessary in the mean level.

  • PDF

A Study on the Performance Prediction of Low Temperature Thermal Desorption System (저온 수처리장치 열교환기의 열전달 특성에 관한 연구)

  • Lee, C.T.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.76-81
    • /
    • 2009
  • Thermal desorption systems are designed to remove organic compounds from solid matrices such as soils, sludges and filter cakes without thermally destroying them. It is a separation technology, not a destruction technology. Since it is a thermal process, there is a common belief that temperature is the only significant parameter to be monitored. While it is true that better removal efficiencies are usually achieved at higher temperatures, other factors must be considered. Since the process is governed by mass transfer, heating time and the amount of mixing are also key parameters in optimizing removal efficiency. Thermal desorption have been successfully used for just about every organic contaminant found to date. It has also been used to remove mercury. In the present study, the numerical simulation has been performed to investigate the characteristics of heat transfer of LTTD(low temperature thermal desorption). The commercial software, AMESIM was applied for analyzing the heat transfer process in the LTTD.

  • PDF

Analysis on the Likelihood of Axisymmetric Wave Propagation in Buried Water Pipes (지하매설 배관의 축대칭 파동 전파 가능성 해석)

  • Park, Kyung-Jo
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.36-41
    • /
    • 2013
  • A study of the possible axisymmetric modes that propagate at low frequencies in buried, water-filled pipes is presented. It is well known that for a vacuum-pipe-vacuum system the sole non-torsional axisymmetric mode that exists at low frequencies is the fundamental L(0,1) mode. When a pipe is filled with water and still surrounded by a vacuum it is also known that another mode then appears which at low frequencies is characterized by predominantly axial water-borne displacements. In addition to these modes. this paper explores two other, less well known axisymmetric modes whose exitence depends on the acoustic properties of the outer medium that surrounds a pipe. The predicted characteristics of these modes are presented and the likelihood of them propagating over any significant distance in a buried water pipe is discussed.

Design of Low Pass Filter to reduce EMI from 2.SG SDH system (2.5G SDH 전자파 감소용 저역통과필터 설계)

  • 이성원;김영범
    • Journal of the Korea Society for Simulation
    • /
    • v.10 no.4
    • /
    • pp.21-30
    • /
    • 2001
  • In this paper, EMI measurement, the STGU simulation being conducted, filter design, its characteristics, and its implementation to the PCB, and finally test results are discussed. When the low pass filter was implemented within the STGU, the power of EMI decreased more than 20dBm. Finally, when TE and MTIE, two important quality measure in synchronous reference clock, was assessed, ITU-T G813 requirement was satisfied. EMI(Electromagnetic Interface) is a measure of electomagnetic radiation from equipment in the range of 10KHz to 3GHz, and can cause unexpected reactions of electronics/electrical equipment. In this study, for safe and stable communication operation, a STGU (System Timing Generation Unit), which is a 2.5G SDH System and a major EMI source, was employed to simulate electromagnetic interface. Using Open-Site test, the power of fundamental frequency of EMI of interest and its harmonics were measured. Also, a low pass filter at cut-off frequency of 2GHz was specifically designed for this study to minimize the effect of EMI between electronic components.

  • PDF

Characteristics of Acoustic Waves That Propagate in Buried Iron Water Pipes (매립된 유체함입 강파이프의 파동전파 특성규명)

  • Park, K.J.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.65-70
    • /
    • 2006
  • A study of the possible axisymmetric modes that propagate at low frequencies in buried, water-filled iron pipes is presented. It is well known that for a vacuum-pipe-vacuum system the sole non-torsional axisymmetric mode that exists at low frequencies is the fundamental L(0,1) mode. When a pipe is filled with water and still surrounded by a vacuum it is also known that another mode then appears which at low frequencies is characterized by predominantly axial water-borne displacements. In addition to these modes, this paper explores two other, less well known axisymmetric modes whose existence depends on the acoustic properties of the outer medium that surrounds a pipe. In this paper the predicted characteristics of these modes are presented.

  • PDF

An Experimental Study on the Efficiency of the Water Hydraulic Piston Pump System driven by an Electric Inverter (전기 인버터 구동 수압 피스톤 펌프 시스템의 효율 성능에 관한 실험적 연구)

  • Ham, Y.B.;Park, J.H.;Kim, S.D.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.4
    • /
    • pp.1-7
    • /
    • 2006
  • A water hydraulic pump is likely to have serious problems of high leakage, friction and low energy efficiency. A water hydraulic pump has commonly a fixed displacement type and its outlet flow is adjusted by controlling rotation speed of the pump, which can be implemented by using an electric inverter. This study aims to investigate energy efficiency of the water hydraulic pump system which is driven by an electric inverter. The study is based on the experimental results. The pump which is used in the study shows relatively good efficiency and low leakage, low friction as well. The reasons for the good performance of pump is also investigated.