• 제목/요약/키워드: Low-flow channel

검색결과 351건 처리시간 0.013초

Analysis of Channel Flow Low During Fuelling Operation of Selected Fuel Channels at Wolsong NPP

  • I. Namgung;Lee, S.K.
    • Nuclear Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.502-516
    • /
    • 2002
  • Wolsong NPP are CANDU6 type reactors and there are 4 CANDU6 type reactors in commercial operation. CANDU type reactors require on-power refuelling by two remote controlled F/Ms (Fuelling Machines). Most of channels, fuel bundles are float by channel coolant flow and move toward downstream, however in about 30% of channels the coolant flow are not sufficient enough to carry fuel bundles to downstream. For those channels a special device, FARE (Flow Assist Ram Extension) device, is used to create additional force to push fuel bundles. It has been showing that during fuelling operation of some channels the channel coolant flow rate is reduced below specified limit (80% of normal), and consequently trip alarm signal turns on. This phenomenon occurs on selected channels that are instrumented for the channel flow and required to use the FARE device for refuelling. Hence it is believed that the FARE device causes the problem. It is also suspected that other channels that do not use the FARE device for refuelling might also go into channel flow low state. The analysis revealed that the channel How low occurs as the FARE device is introduced into the core and disappears as the FARE device is removed from the core. This paper presented the FARE device behavior, detailed fuelling operation sequence with the FARE device and effect on channel flow low phenomena. The FARE device components design changes are also suggested, such as increasing the number or now holes in the tube and flow slots in the ring orifice.

다양한 하천복원 기술을 통한 원주천의 어류 서식처 향상에 대한 연구 (A Study on the Improvement of Fish Habitat through Various River Restoration Techniques in the Wonju-cheon Stream, Korea)

  • 김종주;최종근;최흥식
    • Ecology and Resilient Infrastructure
    • /
    • 제6권3호
    • /
    • pp.145-153
    • /
    • 2019
  • 본 연구는 저수로 변화를 통한 하천 복원이 수생 서식처에 미치는 영향을 파악하기 위하여 원주천을 대상으로 물리서식처분석을 수행하였다. 대상 어종은 원주천에 서식하는 우점종인 피라미를 대상으로 하였다. 흐름 분석은 2차원 모형인 River2D 모형을 사용하였으며, 서식처 분석은 서식처 적합도 곡선을 이용하여 서식처의 양과 질을 산정하는 서식처 적합도 모형을 사용하였다. 먼저 저수로 복원을 위하여 자연 하도에 가까운 형태로 복원을 하고 저수로 폭을 확대 및 축소하여 설계하였다. 그 결과 저수로 폭의 변화를 확대하였을 때 대상 어종의 가중가용면적은 각각 약 72% 향상되었으며, 저수로 폭을 축소하였을 때는 서식처가 약 25% 악화되는 것으로 나타났다.

DEVELOPMENT OF AN IMPROVED FARE TOOL WITH APPLICATION TO WOLSONG NUCLEAR POWER PLANT

  • Lee, Sun Ki;Hong, Sung Yull
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.257-264
    • /
    • 2013
  • In Canada Deuterium Uranium (CANDU)-type nuclear power plants, the reactor is composed of 380 fuel channels and refueling is performed on one or two channels per day. At the time of refueling, the fluid force of the cooling water inside the channel is exploited. New fuel added upstream of the fuel channel is moved downstream by the fluid force of the cooling water, and the used fuel is pushed out. Through this process, refueling is completed. Among the 380 fuel channels, outer rows 1 and 2 (called the FARE channel) make the process of using only the internal fluid force impossible because of the low flow rate of the channel cooling water. Therefore, a Flow Assist Ram Extension (FARE) tool, a refueling aid, is used to refuel these channels in order to compensate for the insufficient fluid force. The FARE tool causes flow resistance, thus allowing the fuel to be moved down with the flow of cooling water. Although the existing FARE tool can perform refueling in Korean plants, the coolant flow rate is reduced to below 80% of the normal flow for some time during refueling. A Flow rate below 80% of the normal flow cause low flow rate alarm signal in the plant operation. A flow rate below 80% of the normal flow may cause difficulties in the plant operation because of the increase in the coolant temperature of the channel. A new and improved FARE tool is needed to address the limitations of the existing FARE tool. In this study, we identified the cause of the low flow phenomena of the existing FARE tool. A new and improved FARE tool has been designed and manufactured. The improved FARE tool has been tested many times using laboratory test apparatus and was redesigned until satisfactory results were obtained. In order to confirm the performance of the improved FARE tool in a real plant, the final design FARE tool was tested at Wolsong Nuclear Power Plant Unit 2. The test was carried out successfully and the low flow rate alarm signal was eliminated during refueling. Several additional improved FARE tools have been manufactured. These improved FARE tools are currently being used for Korean CANDU plant refueling.

Flow of a low concentration polyacrylamide fluid solution in a channel with a flat plate obstruction at the entry

  • Kabir, M.A.;Khan, M.M.K.;Rasul, M.G.
    • Korea-Australia Rheology Journal
    • /
    • 제16권2호
    • /
    • pp.63-73
    • /
    • 2004
  • Flow in a channel with an obstruction at the entry can be reverse, stagnant or forward depending on the position of the obstruction. These flow phenomena have potential applications in the control of energy and various flows in process engineering. Parameters that affect this flow inside and around the test channel are the gap (g) between the obstruction geometry and the test channel, the Reynolds number (Re) and the length (L) of the test channel. The influence of these parameters on the flow behavior was investigated using a flat plate obstruction at the entry of the channel. A low concentration polyacrylamide solution (0.018% by weight) showing a powerlaw fluid behavior was used as the fluid in this investigation. The flow phenomena were investigated by the velocity measurement and the flow visualization and their results were compared with numerical simulation. These results of low concentration polyacrylamide solution are also compared with the results of water published elsewhere (Kabir et al., 2003). The maximum reverse flow inside the test channel observed was 20% - 30% of the outside test channel velocity at a g/w (gap to width) ratio of 1 for Reynolds numbers of 1000 to 3500. The influence of the test channel length (L) and the Reynolds number (Re) on the velocity ratio ($V_i$/$V_o$: inside velocity/outside velocity in the test channel) are also presented and discussed here.

채널 간격에 따른 대향류 확산화염의 가연 영역의 변화 (Flammability Limits Variation of Opposed Flow Diffusion Flames for Different Channel Gap)

  • 이민정;김남일
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.323-324
    • /
    • 2012
  • Flammability limits of opposed flow diffusion flame in a narrow channel was investigated experimentally and theoretically. There were three different extinction modes corresponding to high strain rate (HSR), low strain rate (LSR) and dilution ratio (DR) limits. To investigate these limits, a theoretical study was followed by focusing on flow and heat transfer characteristics. Consequently, a dead space concept that has been used for premixed flames was important to reveal the heat loss mechanism in a narrow channel especially for LSR conditions even in the case of diffusion flames.

  • PDF

복단면인 직선수로 내 사행 저수로의 형태에 따른 흐름특성 연구 (A Study on Flow Characteristics according to Meandering Low Flow Channel Shape in the Compound Cross Section Typed Straight Channel)

  • 김성환;최계운
    • 한국습지학회지
    • /
    • 제19권4호
    • /
    • pp.484-490
    • /
    • 2017
  • 복단면 형태를 이루는 직선하도 내 사행하는 저수로의 형태에 따른 흐름 특성을 파악하기 위해, 국내 대표적인 하도 형태를 상정해 실내 수리모형을 실시해서 3차원 수치모의의 유효성을 확인하고, 이를 바탕으로 다른 유형의 하도 형태에 대해서도 수치모의로 검토를 실시하였다. 본 연구결과, 수리모형 실험에서 관측한 수심별 유속값을 이용하여 수치모형의 검정을 수행한 결과, 수치모의 결과와 충분히 일치하는 것으로 확인하였다. 이를 토대로, 추가적인 저수로 형태 변화에 따른 유동장에 대해 분석한 바에 따르면, 선행 연구들에서 검토된 이차류 현상이 발생하였음을 확인한 한편, 고수부지 내 유수단면적 확대에 따라 최고유속분포 지점이 이동하는 현상을 확인할 수 있었다. 궁극적으로 저수로 폭 변화가 흐름에 영향을 끼쳐 궁극적으로 하천설계에 중요한 요소인 수충부의 위치와 그 영향 정도를 파악하는 것이 필요하다고 판단된다.

저수로 물길 복원을 통한 서식처 공간 변화 연구 (A Case Study of the Habitat Changes due to the Restoration of Low-Flow Channel)

  • 최종근;최흥식;최병웅
    • Ecology and Resilient Infrastructure
    • /
    • 제6권1호
    • /
    • pp.58-68
    • /
    • 2019
  • 본 연구는 저수로 물길 복원 조성을 통한 복원이 어류 서식처에 미치는 영향을 파악하기 위하여 원주천을 대상으로 물리서식처 분석을 수행하였다. 대상 어종은 원주천 중 상류에 서식하는 우점종인 참갈겨니를 대상으로 하였다. 흐름 분석은 2차원 모형인 River2D 모형을 사용하였으며, 서식처 분석은 서식처 적합도 곡선을 이용하여 서식처의 양과 질을 산정하는 서식처 적합도 모형을 사용하였다. 먼저 저수로 복원을 위하여 대상 구간의 강턱유량을 통하여 저수로 물길을 확인하고, 이를 통해 수리학적으로 유리한 저수로 단면을 설계하였다. 또한, 저수로 구간에 거석, 여울/소 구조, 그리고 단면 확폭을 통하여 다양한 복원기법을 적용하였다. 그 결과 수리학적으로 유리한 저수로 물길 복원 조성의 경우 현상태의 하폭보다 감소하였기 때문에 서식처가 악화되는 것으로 나타났다. 그러나 다양한 복원 기법을 적용하였을 때 서식처는 약 11% 정도 향상되는 것으로 나타났다.

수동급기 직접 메탄올 연료전지의 유로에 따른 성능 평가 (Performance evaluation by flow channel effect for a passive air-breathing Direct Methanol Fuel Cell)

  • 장익황;하승범;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.45-48
    • /
    • 2008
  • This paper presents a passive air-breathing direct methanol fuel cell (DMFC) which has been designed and tested. The single cell is fuelled by methanol vapor that is supplied through flow channel from a methanol reservoir at the anode, and the oxygen is supplied via natural air-breathing at the cathode. The methods for supplying the methanol vapor to the single cell were parallel channel and chamber. This research investigates various methods to identify the effects of using flow channels for providing the methanol vapor at the anode, and the opening ratio between the inlet and outlet ports for the methanol flow at the anode. The best flow channel condition for passive DMFC was a chamber, and the opening ratio was 0.8. Under these conditions, the peak power was 10.2mW/$cm^2$ at room temperature and ambient pressure. The key issues for the Passive DMFCs for using methanol vapor are that sufficient methanol needs to be supplied using a large as possible opening ratio. However, it is shown that the performance of the passive DMFC, which has a channel at the anode,is low due to the low differential pressure and insufficient methanol supply rate.

  • PDF

연료극과 공기극 유로의 겹침이 PEMFC 성능에 미치는 영향 (An Effect of the Overlapping with the Anode and Cathode Flow Channel to PEMFC Performance)

  • 이지홍;이명용;이상석;이도형
    • 신재생에너지
    • /
    • 제5권1호
    • /
    • pp.18-25
    • /
    • 2009
  • PEMFC (Proton Exchange Membrane Fuel Cell) is a low temperature fuel cells which are high efficient and clean energy. But it has many problems like economical efficiency or durability. Because of this reason, many researchers challenge various view points. One of challenge is the flow channel design and many researchers develop new flow channel design. In addition to most of them have the anode and cathode's flow channel overlapped almost perfectly. In this case, the electrochemical reaction is almost done by the inertial force of flow. So we study on the effect of the anode and cathode's flow channel which aren't overlapped perfectly, have more diffusion effect, to PEMFC performance using CFD.

  • PDF

Numerical Simulation of Flow Field and Organism Concentration in a UV Disinfection Channel

  • Li, Chan;Deng, Baoqing;Kim, Chang-Nyung
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2816-2821
    • /
    • 2008
  • This paper investigates the flow field and organism concentration in a UV disinfection channel in which vertical ultraviolet lamps are arranged in a staggered configuration. Turbulence is described by low Reynolds number ${\kappa}-{\varepsilon}$ turbulence model and standard ${\kappa}-{\varepsilon}$ turbulence model, respectively. P-1 method has been employed to solve the radiative transfer equation. The obtained incident radiation is used to compute the inactivation term in the species equation. The CFD results are in good agreement with the existing experimental data for the UV channel. For the flow field, the low-Reynolds number ${\kappa}-{\varepsilon}$ model is superior to the standard ${\kappa}-{\varepsilon}$ model. The approach velocity has a significant effect on the disinfection efficiency. The organism concentration at the outlet decreases fast to a low inlet velocity.

  • PDF