• Title/Summary/Keyword: Low-flow

Search Result 6,335, Processing Time 0.037 seconds

Dysmenorrhea and Its Related Factors among Women's High School Srudents in an Urban Area (도시지역 일부 여자고등학생들의 월경통과 관련요인)

  • Shin, Soo-Hee;Yang, Hye-Kyeong;Cho, Young-Chae
    • Journal of the Korean Society of School Health
    • /
    • v.20 no.1
    • /
    • pp.91-101
    • /
    • 2007
  • Purpose: The present study intended to reveal the association between the physique of adolescent women and dysmenorrhea, and the factors related to the frequency of dysmenorrhea. Methods: The study subjects included 511 girls of a women's high school in Daejeon city and they were, during the period of March 1st through April 30th, 2005, given self-administered questionnaires about frequency of menstruation, age, physique, exercise, and such menstruation-related items as age of menarche, menstrual period and days, and amount. Results: As with the frequency of dysmenorrhea, 38.4% experienced it 「always」, 44.6% 「occasionally」, and 17.0% 「almost scarcely」, and those with dysmenorrhea accounted for 83.0% of the subjects. The frequency of dysmenorrhea was not significant difference according to the BMI and HPI. However, the lower the age of menarche and the greater the amount of menstrual flow, the more frequent dysmenorrhea. The symptoms of dysmenorrhea included the highest frequency of low back pain(68.5%) and it was followed by abdominal pain(65.9%), sensibility(54.0%), fatigue(51.7%), and nervousness(49.5%). These accompanied symptoms tended to be worse as the frequency of dysmenorrhea increased. The multiple logistic regression analysis revealed that the relative risk of frequency of dysmenorrhea is 2.2 times in age of 14, by a standard age of 15 as menarchial age, 2.2 in 13, and 3.1 in below 12. The menstrual days was 3.0 times in both below 2 days and over 8 days with the standard days of 3-7 days. The menstrual amount was 1.9 times in the group with a greater amount of menstrual bleeding and 1.5 times in the group with a less amount than the normal group, respectively. Conclusion: The above results suggest that the rate of experiencing dysmenorrhea was up to 83.0% and 38.4% from these had dysmenorrhea upon every menstruation. It is thought that dysmenorrhea could be a great disadvantage sufficient to impair optimal health to a larger body of school girls. Further, for quality of life, it is required that more fundamental strategies instead of pain killers or others for palliation of dysmenorrhea would be established among adolescents.

Determination of Optimum Capacity Rainwater Utilizing Facilities by Analysis of the Water Supply by Land Use Scenario (토지이용 시나리오별 용수공급 분석에 따른 빗물이용시설 최적 용량 결정)

  • Lim, Seok Hwa;Kim, Byung Sung;Ryoo, Kyong Sik;Lee, Sang Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.387-397
    • /
    • 2021
  • Most of Korea's agricultural water is supplied by reservoirs, so dependence on them is very high. Accordingly, it is important to reduce this dependence and provide a stable agricultural water supply by utilizing an applicable alternative water source. Therefore, in this work, scenarios for different land uses were constructed, and an optimal water supply plan using rainwater and reused sewage water - which are alternative water sources - was created. A study was also conducted to determine the optimal capacity of a rainwater facility. From the analysis, a stable water supply was achieved in the scenario of maximum utilization of rainwater by changing an existing paddy area to a greenhouse area, and about 0.82 ton of flow capacity was required for 1 mm of rainfall on farms utilizing rainwater. As a result of analyzing the optimal scenario to derive the ratio of the storage capacity per unit water collection area, the rainwater storage capacity determined through MODSIM and the storage capacity determined through actual monitoring showed similar results, about 31 and 32 %, respectively, and the optimal capacity of rainwater facilities was calculated to be about 5,796,000-6,182,400 ton.

Basic Study on 250KW-class IoT Electric Heater for Ship Fuel Heating (선박연료 가열용 250KW급 판형 IoT 전기히터의 기초연구)

  • Jang, Sung-Cheol
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.63-68
    • /
    • 2021
  • Domestic electric heater manufacturers are focusing on technology development to improve the efficiency of existing products. The electric heater for ship fuel is large in size and has high difficulty in miniaturization/high efficiency, so there are not many companies that try to develop technology yet. The existing electric heater has a structure of low heating efficiency because the contact time with the heat exchange tube of the heating medium is very short because the flow path of the ship engine fuel is monotonous. Since it is manufactured in a tubular shape, the volume is very large regardless of the heating efficiency. As a result, the tubular electric heater device applied by overseas advanced companies has difficulty in maintaining and repairing because it is necessary to decompose all tubular heaters when a specific part of the inside is damaged and if the heat exchange tube is damaged, all the heat exchange tubes must be decomposed. In this study, a basic study on plate type electric heaters capable of heating 10 tons of ship engine fuel per hour and setting a maximum temperature of up to 150℃ was conducted through a 250kW capacity plate type electric heater.

Anthracite Oxygen Combustion Simulation in 0.1MWth Circulating Fluidized Bed (0.1 MWth 급 순환유동층에서의 무연탄 연소 전산유체역학 모사)

  • Go, Eun Sol;Kook, Jin Woo;Seo, Kwang Won;Seo, Su Been;Kim, Hyung Woo;Kang, Seo Yeong;Lee, See Hoon
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.417-428
    • /
    • 2021
  • The combustion characteristics of anthracite, which follow a complex process with low reactivity, must be considered through the dynamic behavior of circulating fluidized bed (CFB) boilers. In this study, computational fluid dynamics (CFD) simulation was performed to analyze the combustion characteristics of anthracite in a pilot scale 0.1 MWth Oxy-fuel circulating fluidized bed (Oxy-CFB) boiler. The 0.1MWth Oxy-CFB boiler is composed of combustor (0.15 m l.D., 10 m High), cyclone, return leg, and so on. To perform CFD analysis, a 3D simulation model reactor was designed and used. The anthracite used in the experiment has an average particle size of 1,070 ㎛ and a density of 2,326 kg/m3. The flow pattern of gas-solids inside the reactor according to the change of combustion environment from air combustion to oxygen combustion was investigated. At this time, it was found that the temperature distribution in air combustion and oxygen combustion showed a similar pattern, but the pressure distribution was lower in oxygen combustion. addition, since it has a higher CO2 concentration in oxygen combustion than in air combustion, it can be expected that carbon dioxide capture will take place actively. As a result, it was confirmed that this study can contribute to the optimized design and operation of a circulating fluidized bed reactor using anthracite.

A Study on Improvement of Hydrologic Cycle by Selection of LID Technology Application Area -in Oncheon Stream Basin- (LID 기술 적용 지역 선정에 따른 물순환 개선 연구 -온천천 유역을 대상으로-)

  • Kim, Jae-Moon;Baek, Jong-Seok;Shin, Hyun-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.545-553
    • /
    • 2021
  • The frequency by water disaster in urban areas are increasing continuously due to climate change and urbanization. Countermeasures are being conducted to reduce the damage caused by water disasters. An analysis based on permeability, one of the parameters that affect runoff, is needed to predict quantitative runoff in urban watersheds and study runoff reduction. In this study, the SWAT model was simulated for the oncheon stream basin, a representative urban stream in Busan. The permeability map was prepared by calculating the CN values for each hydrologic response unit. Based on the permeability map prepared, EPA SWMM analyzed the effect of LID technology application on the water cycle in the basin for short-term rainfall events. The LID element technology applied to the oncheon stream basin was rooftop greening in the residential complex, and waterproof packaging was installed on the road. The land cover status of the land selected based on the permeability map and the application of LID technology reduced the outflow rate, peak flow rate, and outflow rate and increased the infiltration. Hence, LID technology has a positive effect on the water cycle in an urban basin.

A Study on the Fundamental Properties of Mortar Mixed with Converter Slag and Ferronickel Slag (전로슬래그 및 페로니켈슬래그를 혼입한 모르타르의 기초물성 연구)

  • Kim, Ji-Seok;Park, Eon-Sang;Ann, Ki-Yong;Cho, Won-Jung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.152-160
    • /
    • 2021
  • Converter steel slag(BOF slag) is a vast amount of solid waste generated in the steelmaking process which has very low utilization rate in Korea. Due to the presence of free CaO which can derive bad volume stability in BOF slag, it usually land filled. For recycling BOF and identify its applicability as fine aggregate, this study investigates the fundamental characteristics of mortar with cement replaced ferronickel slag(FNS), which has the potential to be used as a binder. The results suggest that the mineral phases of BOF slag mainly include larnite(CaSiO4), mayenite(Ca12Al14O33) and wuestite(FeO) while olivine crystallines are shown in FNS. The results of flow and setting time reveals that the flowability and process of hardening increased when the amount of FNS and BOF slag incorporated was increased. The length change shows that the amount of change in the length of the mortar was almost constant regardless of mix proportion while compressive strength was reduced. Micro structure test results revealed that FNS or/and BOF slag mix took a long time to react in the cement matrix to form a complete hydration products. To achieve the efficient utilization of B OF slag as construction materials, proper replacement rate is necessary.

Analysis of Rainfall-Runoff Characteristics in Gokgyochun Basin Using a Runoff Model (유출모형을 이용한 곡교천 유역의 강우-유출 특성 분석)

  • Hwan, Byungl-Ki;Cho, Yong-Soo;Yang, Seung-Bin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.404-411
    • /
    • 2019
  • In this study, the HEC-HMS was applied to determine rainfall-runoff processes for the Gokgyuchun basin. Several sub-basins have large-scale reservoirs for agricultural needs and they store large amounts of initial runoff. Three infiltration methods were implemented to reflect the effect of initial loss by reservoirs: 'SCS-CN'(Scheme I), 'SCS-CN' with simple surface method(Scheme II), and 'Initial and Constant rate'(Scheme III). Modeling processes include incorporating three different methods for loss due to infiltration, Clark's UH model for transformation, exponential recession model for baseflow, and Muskingum model for channel routing. The parameters were calibrated using an optimization technique with trial and error method. Performance measures, such as NSE, RAR, and PBIAS, were adopted to aid in the calibration processes. The model performance for those methods was evaluated at Gangcheong station, which is the outlet of study site. Good accuracy in predicting runoff volume and peak flow, and peak time was obtained using the Scheme II and III, considering the initial loss, whereas Scheme I showed low reliability for storms. Scheme III did not show good matches between observed and simulated values for storms with multi peaks. Conclusively, Scheme II provided better results for both single and multi-peak storms. The results of this study can provide a useful tool for decision makers to determine master plans for regional flood control management.

A Study on Analysis and user-friendly Improvement Plan for Urban Planning Information System (수요자 중심의 도시계획정보체계 개선방안)

  • Lee, Se-won;Kang, Ji-Hun;Kim, Heung-Cheol
    • Journal of Cadastre & Land InformatiX
    • /
    • v.48 no.2
    • /
    • pp.153-170
    • /
    • 2018
  • The purpose of this study is to diagnose problems by analyzing the status of system and user in order to activate the Urban Planning Information System(UPIS). The UPIS has been distributed to all local governments through pilot and expansion projects since 2003 to utilize spatial information in urban planning and administration. The original purpose was to use GIS to support planning and to support scientific decision making, but now the main task is to designate and manage zoning districts related to land use. Therefore, the UPIS is responsible for the production (preparation procedure) and management of the local district information for use in the Korea land use information system, which is an upper concept defined by the law, but it is evaluated that its identity is ambiguous and utilization rate is low. This study is conducted to investigate the four aspects (business process, database, system, citizen service) of UPIS, and suggest concrete improvement measures. To summarize, each individual system exists in the Korea land use information system, but they all share similar data and have a linked work flow. Therefore, we suggested that the DB current plan should be established to improve the reliability of data and to redefine the business process around the UPIS.

Analysis of Proper Linked Treatment Load Using GPS-X Simulation (GPS-X 시뮬레이션을 이용한 적정 연계처리부하량 분석)

  • Kim, Sungji;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.244-250
    • /
    • 2019
  • Due to the industrial development and population growth, it has recently been shown that there are many problems caused by the rinked treatment water in local goverments and sewage treatment plants. The rinked treatment water has a characteristic of low flow rate and high concentration unlike general sewage. These characteristics increase sewage treatment difficulty and sewage treatment fee of sewage treatment facilities. Among the many influencing factors that increase sewage treatment unit cost, 'linked treatment load/design inflow load (%)' was derived as the most correlated factor. Through the selection and modeling of sewage treatment plants, the excess scope of design discharge water quality was investigated under the conditions of temperature and the conditions of 'linked treatment load/design inflow load (%)' taking into account the effects of the four seasons. The study found that for TN, 'linked treatment load/design inflow load (%)' was 19.7%, 22.6%, 25.1%and 27.7%, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$. In case of TP, 'rinked treatment load/design inflow load (%)' was 10.7%, 12.2%, 15.6% and 17.5% at $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$, and $25^{\circ}C$, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$.

Engineering Characteristics of CLSM Using Bottom Ash and Eco-friendly Soil Binder (친환경 고결제와 저회를 활용한 유동성 복토재의 공학적특성)

  • Park, Giho;Kim, Taeyeon;Lee, Yongsoo;Lee, Bongjik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.5
    • /
    • pp.23-29
    • /
    • 2019
  • In general, pipe laying works are performed by constructing underground facilities such as pipes and then refilling the rest of the area with sand or soil. However, there are many problems in the compaction process such as difficulties in tampering around the underground facility and low compaction efficiency. Such problems cause deformation and damage to the underground pipes during refilling work and ultimately cause road sinks. Construction methods using CLSM are one of the typical methods to solve these issues, and recently, studies on CLSM using coal ash, which has similar engineering properties as sand, have been actively performed to protect environment and recycle resources. While many studies have been conducted to recycle fly ash in many ways, the demand for recycling bottom ash is increasing as most of the bottom ash is not recycled and reclaimed at ash disposal sites. Therefore, in order to find bottom ash applications using eco-friendly soil binders that are environmentally beneficial and conform with CLSM standards, this study investigated flow characteristics and strength change characteristics of eco-friendly soil binders, weathered granite soil, a typical site-generated soil, bottom ash, and fly ash mixed soil and evaluated the soil pollution to present CLSM application methods using bottom ash.