• Title/Summary/Keyword: Low-flow

Search Result 6,290, Processing Time 0.029 seconds

Experimental study on the performance characteristics of the diffuser due to the variation of vane angle (베인각도의 변화에 따른 디퓨저의 성능특성에 관한 실험적 연구)

  • Cho, S. K.;Kang, S. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.142-148
    • /
    • 1998
  • Recently for the impressive gains of performance and efficiency over vaneless diffuser with apparently little or no loss in flow range, the use of LSVD(Low Solidity Vaned Diffuser) is well recommended. The experiments on the effect of the vane turning angle variation(positive, negative, zero) with other design parameters fixed on the performance and flow range were carried out. Diffuser with zero turning angle has the best characteristics in terms of performance and efficiency and The FFT results show the different frequency characteristics due to the vane turning angle in low flow range.

  • PDF

NUMERICAL ANALYSIS OF THE GUST GENERATOR FOR KARI LOW SPEED WIND TUNNEL (KARI 중형 아음속 풍동용 돌풍 발생기의 수치해석)

  • Park Y. M.;Kwon K. J.;Lee S. W.;Kim T. W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.275-279
    • /
    • 2005
  • The vortex convection and induced flow field behind the KARI 3m x 4m LSWT gust generator was computed by using Computational Fluid Dynamics. For the accurate simulation of vortex convection, inviscid, laminar, Spalart-Allmars k-e and k-w turbulence models were tested with the NAL gust generator configuration and Spalart-Allmaras turbulence model was selected for the prediction of induced flow field behind the KARI LSWT gust generator. The wind tunnel test was also carried out at KARI LSWT and the results were compared with CFD prediction.

  • PDF

Evaluation of the mechanical pipe flowmeter at low hydraulic head (저수두에서 기계식 관수로 유량계의 적용성 평가)

  • Sohn, Seung-Ho;Chung, Sang-Ok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.53-56
    • /
    • 2002
  • This study presents an evaluation of the mechanical pipe flowmeter at low hydraulic heads. Three flowmeters each of 75mm and 25mm diameter were used. The Flowmeter was tested with experimental open channel apparatus. Relationship between flowmeter values and bucket values was good. The 75mm diameter flow meter showed small relative errors with hydraulic heads above 9cm. The 25mm diameter flow meter showed small relative errors with hydraulic heads above 2cm. The Irrigation flow measurement using the mechanical pipe flowmeter of 75mm diameter in paddy fields needs hydraulic head above 9cm, which is easy to get in tertiary canals.

  • PDF

Electrical Performance Characteristics of 200W PEM-Type Fuel Cells with Variations on Mass Flow Rate and Stack Temperature (공급유량 및 스택온도의 변이에 따른 200W급 PEM형 연료전지의 전기적 성능특성)

  • Hong, Kyung-Jin;Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.563-567
    • /
    • 2009
  • The polymer electrolyte membrane fuel cell(PEMFC) with the advantages of low-operating temperature, high current density, low cost and volume, fast start-up ability, and suitability for discontinuous operation becomes the most reasonable and attractive power system for transportation vehicle and micro-grid power plant in a household. 200W PEM-type FCs system was integrated by this study, then the electrical characteristics and diagnosis of the fuel cell were analyzed with variations on mass flow rate and stack temperature. The ranges of the variations are 1~8L/min on $H_2$ volume and $20{\sim}70^{\circ}C$ on stack temperature.

A Research for Reducing Methods of Sub-synchronous Vibration in Water Turbines (수차에서 발생되는 유체여기진동 저감방안 연구)

  • Park, Han-Yung;Cho, Sung-Su;Ra, Beyong-Pil;Kim, Jin-Hun;Park, Jong-Ho;Lee, Yeon-Ju
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.13-18
    • /
    • 2009
  • In this paper, it is intended to figure out the features and causes of the processes of creation, growth and disappearance of spiral-vortex-flow generated in Francis turbines generally. The spiral-vortex-flow generated in draft tubes of the Francis turbines is estimated to have negative effects on power plant structure and to the people inside the building as well as to lead to a low-frequency-vibration driven by sub-synchronous whirl vibration. Therefore, we intend to investigate how much the low-frequency-vibration has an influence upon the powerhouse structure and practice analyzing the effectiveness on the previously-introduced methods to reduce side-effects of sub-synchronous whirl vibration and finally we intend to show the optimal solutions through this paper.

DFSS OPTIMUM DESIGN OF LOW NOISE COOLING FAN FOR AN ALTERNATOR BY NUMERICAL METHOD (수치기법을 이용한 저소음 얼터네이터 냉각팬의 DFSS 최적 설계)

  • Kim, W.;Jeon, W.H.;Hyun, J.J.;Lim, C.K.;Lee, S.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.233-238
    • /
    • 2008
  • An alternator which converts mechanical rotating energy into electric energy is an important component of a vehicle. It operates in broad range from 3000 RPM to 18000 RPM. So, sufficient flow rate and low noise are needed in such broad operating range for a cooling fan of this alternator. In current study, the cooling fan of an alternator is developed through DFSS process and numerical analysis. In order to calculate flow rate and noise level, SC/Tetra and Flow Noise are used respectively, for a new developed fan, compared with original model, numerical result shows 3 dBA reduction and measured value shows 4 dBA reduction.

  • PDF

A Theoretical Model of Critical Heat Flux in Flow Boiling at Low Qualities

  • Kim, Ho-Young;Kwon, Hyuk-Sung;Hwang, Dae-Hyun;Kim, Yongchan
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.921-930
    • /
    • 2001
  • A new theoretical critical heat flux (CHF) model was developed for the forced convective flow boiling at high pressure, high mass velocity, and low quality. The present model for an intermittent vapor blanket was basically derived from the sublayer dryout theory without including any empirical constant. The vapor blanket velocity was estimated by an axial force balance, and the thickness of vapor blanket was determined by a radial force balance for the Marangoni force and lift force. Based on the comparison of the predicted CHF with the experimental data taken from previous studies, the present CHF model showed satisfactory results with reasonable accuracy.

  • PDF

A Study on Combustion Characteristics in a Low-Pollutant Municipal Waste Incinerator - Development and Validation of a Multi-Block Simulation Code - (저공해 도시 쓰레기 소각로의 연소특성 연구 - 다중블럭 해석 프로그램의 개발 및 검증 -)

  • Sohn, Young-Min;Kim, Man-young;Baek, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.534-541
    • /
    • 2003
  • To investigate the combustion characteristics in a low-pollutant municipal waste incinerator, the generalized multi-block simulation code that can be applied to turbulent reacting flow with gaseous hydrocarbon fuel in a 3D complex geometry has been developed with nongray radiation effects. To deal with the complex geometry, structured multi-block method and the scheme which treats interfaces implicitly are adopted. The developed code is validated through various engineering problems such as curved duct flow, driven cavity flow, gray multi-block radiation, nongray radiation. and combustion in a incinerator.

DFSS OPTIMUM DESIGN OF LOW NOISE COOLING FAN FOR AN ALTERNATOR BY NUMERICAL METHOD (수치기법을 이용한 저소음 얼터네이터 냉각팬의 DFSS 최적 설계)

  • Kim, W.;Jeon, W.H.;Hyun, J.J.;Lim, C.K.;Lee, S.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.233-238
    • /
    • 2008
  • An alternator which converts mechanical rotating energy into electric energy is an important component of a vehicle. It operates in broad range from 3000 RPM to 18000 RPM. So, sufficient flow rate and low noise are needed in such broad operating range for a cooling fan of this alternator. In current study, the cooling fan of an alternator is developed through DFSS process and numerical analysis. In order to calculate flow rate and noise level, SC/Tetra and Flow Noise are used respectively, for a new developed fan, compared with original model, numerical result shows 3 dBA reduction and measured value shows 4 dBA reduction.

  • PDF

A study on the tensile strength of flow-soldered joint using low residue flux (저잔사 플럭스를 사용한 플로 솔더링부의 인장특성 연구)

  • 장인철;최명기;신영의;정재필;서창제
    • Journal of Welding and Joining
    • /
    • v.17 no.1
    • /
    • pp.77-81
    • /
    • 1999
  • Through-hole PCB(Printed Circuit Board) was soldered by flow soldering process using cleaning or noncleaning fluxes. Preheating temperature and conveyor speed were changed in the range of 323∼413K and 0.3∼2m/min respectively. The soldered joints were tensile tested in order to evaluated bonding strength. As experimental results, relatively high tensile fracture load, 120∼140N, were obtained in case of preheating temperature of 383K, and conveyor speed was 0.6∼1.0 m/min. Fractured surfaces of higher tensile strength show some dimple area, while those of lower tensile fracture load show brittle fracture.

  • PDF