• Title/Summary/Keyword: Low-density concentration

Search Result 714, Processing Time 0.025 seconds

Studies on the Geological Environment of the Nanjido Waste Disposal Site: Gravity and Magnetic Investigations (난지도 매립지 및 그 주변의 지질환경 연구: 중력 및 자력탐사)

  • Kwon, Byung-Doo;Kim, Cha-Seop;Chung, Ho-Joon;Oh, Seok-Hoon
    • Economic and Environmental Geology
    • /
    • v.28 no.5
    • /
    • pp.469-480
    • /
    • 1995
  • Gravity and magnetic surveys were carried out to investigate the three-dimensional configuration and characteristics of the landfills at Nanjido waste disposal site. For terrain correction and three-dimensional density inversion of gravity data an algorithm, which calculates the gravity effect of a three-dimensional body by using the solid angle method, is developed. This algorithm has been proved to give more accurate terrain correction values for the small survey area having varied topography like Nanjido site as compared with widely used methods such as Hammer's method and multiquadric equation method. Density inversion of gravity anomaly data gives very useful information about the lateral and vertical variation of the landfills, which can be used to discriminate the kinds of wastes. The average density of filled materials appears to be $1.7\;g/cm^3$ which is much higher than the value $(0.8\;g/cm^3)$ estimated by Seoul City. The lateral variation of density shows high correlation with the pattern of ongoing depression of the landfills. The northern region of the landfill no. 1, which shows low density and high depression, is closely associated with the industrial waste and sludge filled area. The magnetic anomaly data provide information about relative concentration of magnetic materials, which is also very useful to investigate characteristics of the fills. Several high positive anomaly regions on the reduced-to-pole magnetic anomaly map are appeared to be associated with the industrial waste fills, but certain industrial waste fills show low negative anomalies. This kind of magnetic information can be used in selecting drilling locations over landfills away from buried metal products during the stabilization process.

  • PDF

The Effect of Pulse Plating on the Current Efficiency in Trivalent Chromium Bath (3가크롬 도금욕에서 펄스도금조건이 전류효율에 미치는 영향)

  • 황경진;안종관;이만승;오영주
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.2
    • /
    • pp.161-167
    • /
    • 2003
  • In order to investigate the effects of pulse plating conditions on the electrodeposition of trivalent chromium, electroplating experiments from bath with low concentration of trivalent chromium were performed. The variation of current efficiency of chromium electroplating with the electroplating conditions was explained. The maximum current efficiency of pulse plating is 6.4 times as high as that of direct plating at the same mean current density The nodular size increased with pulse plating time and the pulse frequency.

Electrical Properties of XLPE/VLDPE B1ends (XLPE/VLDPE 블렌드의 전기적 성질)

  • 고정우;서광석;김종은;강형식;김덕주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.215-218
    • /
    • 1998
  • XLPE/VLDPE (Crosslinked polyethylene/very low density polyethylene) blends were prepared by a twin screw extruder and their electrical properties such as water tree and breakdown characteristic were measured. it was found that both water tree and breakdown characteristics of XLPE were improved by the addition of VLDPE to polyethylene. It was also found that the extent of improvement of electrical properties by the addition of VLDPE to polyethylene depends on the type and concentration of VLDPE.

  • PDF

Prediction of Service Life of a Respirator Cartridge by the Occupational Environment(II) (작업현장의 환경조건에 따른 방독마스크 정화통의 수명예측(II))

  • 김기환;김덕기;신창섭
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.72-78
    • /
    • 1996
  • The breakthrough curves of a sampling tube were studied to predict the service life of a respirator cartridge for organic vapors. The fixed bed adsorption model was applied to respirator cartridge and it's variables were calculated from tile experiment of sampling tube. By the experiment and simulation, it was possible to predict the service life of a respirator cartridge, however, not adequate at low $CCl_4$ concentration less than 700ppm and at high air humidify. The breakthrough curves of sampling tube were irregular compare to that of respirator cartridge due to .packing density.

  • PDF

Effect of Operational Parameters on the Removal of Microcystis aeruginosa in Electro-flotation Process

  • Lucero, Arpon Jr;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.25 no.10
    • /
    • pp.1417-1426
    • /
    • 2016
  • Despite the low removal efficiencies reported by previous studies, electro-flotation still stands out among other microalgae removal methods for its economical and environmental benefits. To enhance removal efficiency, the important factors that limit the performance of this method must be investigated. In this study, the possible ways of increasing the removal efficiency of microalgae have been explored by investigating the effects of several important variables in electro-flotation. Eight parameters, namely flotation time, rising time, current density, pH, conductivity, electrode distance, temperature and initial concentration were evaluated using a one-parameter-at-a-time approach. Results revealed that the operational parameters that greatly affected the removal efficiency of microalgae were electro-flotation time, current density, pH, and initial concentration. The effect of conductivity, electrode distance, and temperature on removal efficiency were insignificant. However, they exhibited positive an indirect positive effect on power demand, which is nowadays considered an equally important aspect in the running of a feasible and economically efficient electro-flotation process.

Effect of Citric Acid in Cu Chemical Mechanical Planarization Slurry on Frictional Characteristics and Step Height Reduction of Cu Pattern

  • Lee, Hyunseop
    • Tribology and Lubricants
    • /
    • v.34 no.6
    • /
    • pp.226-234
    • /
    • 2018
  • Copper chemical mechanical planarization (CMP) has become a key process in integrated circuit (IC) technology. The results of copper CMP depend not only on the mechanical abrasion, but also on the slurry chemistry. The slurry used for Cu CMP is known to have greater chemical reactivity than mechanical material removal. The Cu CMP slurry is composed of abrasive particles, an oxidizing agent, a complexing agent, and a corrosion inhibitor. Citric acid can be used as the complexing agent in Cu CMP slurries, and is widely used for post-CMP cleaning. Although many studies have investigated the effect of citric acid on Cu CMP, no studies have yet been conducted on the interfacial friction characteristics and step height reduction in CMP patterns. In this study, the effect of citric acid on the friction characteristics and step height reduction in a copper wafer with varying pattern densities during CMP are investigated. The prepared slurry consists of citric acid ($C_6H_8O_7$), hydrogen peroxide ($H_2O_2$), and colloidal silica. The friction force is found to depend on the concentration of citric acid in the copper CMP slurry. The step heights of the patterns decrease rapidly with decreasing citric acid concentration in the copper CMP slurry. The step height of the copper pattern decreases more slowly in high-density regions than in low-density regions.

Comparison of Polymer Electrolyte Membrane Fuel Cell performance obtained by 1D and CFD simulations (1D와 CFD(Computational fluid dynamic) 시뮬레이션을 통한 PEMFC(Polymer Electrolyte Membrane Fuel Cell) 성능 비교)

  • Wonwoo Jeon;Sehyeon An;Jaewan Yang;Jiwon Lee;Hyunbin jo;Eunseop Yeom
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.3
    • /
    • pp.49-56
    • /
    • 2023
  • The Polymer electrolyte membrane fuel cell (PEMFC) operates at ambient temperature as a low-temperature fuel cell. During its operation, voltage losses arise due to factors such as operating conditions and material properties, effecting its performance. Computational simulations of fuel cells can be categorized into 1D simulation and CFD, chosen based on their specific application purposes. In this study, we carried out an analysis validation using 1D geometry and compared its performance with the results from 2D geometry analysis. CFD allows for the representation of pressure, velocity distribution, and fuel mass fraction according to the geometry, enabling the analysis of current density. However, the 1D simulation, simplifying governing equations to reduce time cost, failed to accurately account for fuel distribution and changes in fuel concentration due to fuel cell operations. As a result, it showed unrealistic results in the cell voltage region dominated by concentration loss compared to CFD.

Preparation of Porous Cobalt Thin Films by Using an Electrochemical Method (전기화학적 방법을 통한 다공성 코발트 박막 합성)

  • Ha, Seong-Hyeok;Shin, Heon-Cheol
    • Journal of Surface Science and Engineering
    • /
    • v.53 no.6
    • /
    • pp.312-321
    • /
    • 2020
  • Morphology of porous cobalt electro-deposits was systematically investigated as functions of cobalt precursors in the plating bath and applied cathodic current density with a special focus on cobalt nano-rod formation. It was proved that the concentration of cobalt precursor plays little effect on the morphology of cobalt electro-deposits at relatively low plating current density while it significantly affects the morphology with increasing plating current density. Such a dependence was discussed in terms of the kinetics of two competitive reactions of cobalt reduction and hydrogen evolution. Cobalt nano-rod structure was created at specific ranges of cobalt precursor content and applied cathodic current density, and its diameter and length varied with plating time without notable formation of side branches which is usually found during dendrite formation. Specifically, the nano-rod length was preferentially increased in relative short plating time (<15 s), resulting in higher aspect ratio of nano-rod with plating time. Whereas, both the nano-rod length and diameter were increased nearly at the same level in a prolonged plating time, making the aspect ratio unchanged. From the analysis of crystal structure, it was confirmed that the cobalt nano-rod preferentially grew in the form of single crystal on a dense poly-crystalline cobalt thin film initially formed on the substrate.

Indoor air quality evaluation in intercity buses in real time traffic

  • Kazim O. Demirarslan;Serden, Basak
    • Advances in environmental research
    • /
    • v.11 no.1
    • /
    • pp.17-30
    • /
    • 2022
  • Road transport allows all forms of land conditions to be met at less cost. Because of this function, despite numerous disadvantages, it becomes the most frequently used method of transport, especially in underdeveloped or developing countries. One of the most significant factors used in evaluating the atmosphere's air quality is the amount of CO2, increasing people's density in indoor spaces. The amount of CO2 indoors is, therefore, vital to determine. In this study, CO2 and temperature measurements made on nine different bus journey was made in Turkey. The minimum and maximum values were recorded as 555 ppm and 3000 ppm CO2, respectively, in the measurements. On all journeys, the average concentration is 1088.72 ppm. The minimum and maximum values were measured as 17.4℃ and 32.7℃ in the temperature measurements, and the average of all trips was calculated to be 25.76℃. In this study conducted before the Covid-19 pandemic, it was determined that the amount of CO2 increased with the density and insufficient ventilation in the buses. The risk of infection increases in places with high human density and low clean air. For situations such as pandemics, CO2 measurement is a rapid indicator of determining human density.

Characteristics of Power Generation and Organic Matter Removal in Air-Cathode MFC with respect to Microbial Concentration (미생물 농도에 따르는 Air-Cathode MFC의 전력발생과 유기물질제거 특성)

  • Kim, Doyoung;Lim, Bongsu;Choi, Chansoo;Kim, Daehyun
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.917-922
    • /
    • 2012
  • In order to improve applicability of a microbial fuel cell the laboratory-scaled study has been performed by adopting an air-cathode MFC system with high concentrated anaerobic slugies in this study. The concentrations of microbes are grouped into three types, Type A (TS 1.7%), Type B (TS 1.1%) and Type C (TS 0.51%). The open circuit voltage $(V_{oc})$ characteristics showed that the medium microbes concentration of 1.10% (Type B) kept a constant voltage of 1.0 V for 150 hours, which showed the longest time among three types (Type A and Type C). The discharge charge curves for a closed circuit with $500 \Omega$ also showed that Type B generated a stable discharge voltage of 0.8 V for a longer time as in the open circuit voltage case. This could be explained by the relatively large amount of the attached microbes. Under the $V_{oc}$condition the COD removal efficiency of Type B was found to be low for a long time, but those of Type A and C were found to be high for a short period of time. Therefore, the suspended microbes could decrease the coulombic efficiency. It was concluded that the high $V_{oc}$ was caused by low COD and the $V_{oc}$ became low after the COD removal. The COD reduction resulted in an unstable and low working voltage. From the polarization characteristics Type A was found to show the highest power density of $193\;mW/m^2$ with a fill factor of 0.127 due to the relatively high remaining COD even after the MFC reaction.