• Title/Summary/Keyword: Low-Point

Search Result 5,332, Processing Time 0.035 seconds

Inhibition of Endothelial Cell-dependent Serotonin-induced Contraction of ${\beta}-endorphin$ and Increment of Plasma ${\beta}-endorphin$ of Silver Spike Point Low Frequency Electrical Stimulation (${\beta}-Endorphin$의 내피세포의존성-세로토닌 유도-근 수축 억제와 저빈도-주파수 은침점전자극의 혈장 ${\beta}-endorphin$ 증가)

  • Choi Young-Duk;Lee Joon-Hee;Kim Jung-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.22-31
    • /
    • 2004
  • The purpose of this study was to demonstrate the effects of silver spike point (SSP) low frequency electrical stimulation on plasma ${\beta}-endorphin$ activities measured by radio- immunoassay from normal volunteer and the effects of ${\beta}-endorphin$ on 5-hydroxytryptamine (5-HT, serotonin)-induced contraction investigated by isometric tension methode in rats. The current of 3 Hz continue type, but not 100 Hz continue type, of SSP low frequency electrical stimulation significantly increased in plasma ${\beta}-endorphin$ from normal volunteer. The endothelial cell-dependent 5-HT-induced contractions were inhibited by ${\beta}-endorphin$ $1{\mu}M$. These results suggest that the ${\beta}-endorphin$ regulates nociceptive-like substance, such as 5-HT, in part and that the SSP low frequency electrical stimulation, specifically current of low frequency of 3 Hz continue type, significantly increases plasma ${\beta}-endorphin$ from normal volunteer.

  • PDF

Alloy Design and Powder Manufacturing of Al-Cu-Si alloy for Low-Temperature Aluminum Brazing (저온 알루미늄 브레이징용 Al-Cu-Si-Sn 합금 설계 및 분말 제조)

  • Heeyeon Kim;Chun Woong Park;Won Hee Lee;Young Do Kim
    • Journal of Powder Materials
    • /
    • v.30 no.4
    • /
    • pp.339-345
    • /
    • 2023
  • This study investigates the melting point and brazing properties of the aluminum (Al)-copper (Cu)-silicon (Si)-tin (Sn) alloy fabricated for low-temperature brazing based on the alloy design. Specifically, the Al-20Cu-10Si-Sn alloy is examined and confirmed to possess a melting point of approximately 520℃. Analysis of the melting point of the alloy based on composition reveals that the melting temperature tends to decrease with increasing Cu and Si content, along with a corresponding decrease as the Sn content rises. This study verifies that the Al-20Cu-10Si-5Sn alloy exhibits high liquidity and favorable mechanical properties for brazing through the joint gap filling test and Vickers hardness measurements. Additionally, a powder fabricated using the Al-20Cu-10Si-5Sn alloy demonstrates a melting point of around 515℃ following melting point analysis. Consequently, it is deemed highly suitable for use as a low-temperature Al brazing material.

Analysis of Corrosion Resistance and Dew Point with Exhaust Gas Concentration and Temperature for Air Preheater Materials in Power Plants (발전소 공기예열기 소재의 배기가스 농도 및 온도에 따른 내식성 및 노점 분석)

  • Seung-Jun Lee
    • Corrosion Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.351-358
    • /
    • 2023
  • Although many thermal power plants use heat recovery systems, high exhaust gas temperatures are maintained due to corrosion at dew points and ash deposits caused by condensate formation. The dew point of exhaust gas is primarily determined by the concentration of SO3 and steam, and various experiments and calculation equations have been employed to estimate it. However, these methods are known to be less suitable for exhaust gases with low SO3 concentrations. Therefore, in this study, since the temperature of the exhaust gas is expected to decrease due to the low-load operation of the coal-fired power plant, sulfuric acid condensation and low-temperature corrosion are anticipated. We aimed to conduct a quantitative evaluation to propose ways to prevent damage by limiting operating conditions and improving facilities. The experimental results showed that the corrosion rate increased linearly with rising temperatures at a certain sulfuric acid concentration. Furthermore, variations in sulfuric acid concentrations generated during the current power plant operation process did not significantly affect the dew point, and the dew point of sulfuric acid under these conditions was observed to be between 120 - 130 ℃.

A Study on Efficient Technique of 3-D Terrain Modelling (3차원 지형모델링의 효율적 기법에 관한 연구)

  • 윤철규;신봉호;양승룡;엄재구
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.2
    • /
    • pp.207-213
    • /
    • 1997
  • The purpose of this study is to aim at presenting efficient technique of 3-D Terrain Modelling through multilateral approach methods and to compare with raw data, using low-densed randomly located point data. The subject religion of this study are selected two sites and take into consideration for degree of freedom about low-densed randomly located point data. The result of this study by precision analysis of digital cartographic map-ping using low-densed randomly located point data bave shown that . First, making digital cartographic map, the technique of making it using low-desned randomly located point data by TIN-based results to good and fast run-time in A and B sites all together. Second, the visualization analysis results of digital cartographic map using TIN and GRID-based terrain modeling techniqus similar exacts A and B sites, but the terrain modeling techniqus by TIN-based are small data size than GRID-based with the data with the data size of saving with DXF files. Third, making digital catographic map using terrain modeling techniques by Grid-based, the standard errors of low-densed randomly located point data and interpolated data using gridding method have more good results by radial basis function interpolation techniques at A and B sites all together.

  • PDF

Low Cost High Power Density Photovoltaic Power Conditioning System with an Energy Storage System

  • Jang, Du-Hee;Han, Sang-Kyoo
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.487-494
    • /
    • 2012
  • A new low cost high power density photovoltaic power conditioning system (PV PCS) with an energy storage system is proposed in this paper. Its high power density and cost effectiveness can be achieved through the unification of the maximum power point tracker and the battery charger/discharger. Despite the reduced power stage, the proposed system can achieve the same performance in terms of maximum power point tracking and battery charging/discharging as the conventional system. When a utility power failure happens, the proposed system cannot perform maximum power point tracking at the UPS mode. However, the predetermined battery voltage near the maximum power point of the PV array can effectively generate a reasonable PV power even at the UPS mode. Therefore, it features a simpler structure, less mass, lower cost, and fewer devices. Finally, to confirm the operation, validity, and features of the proposed system, a theoretical analysis and experimental results from a single phase AC 220Vrms/1.5kW prototype are presented.

Electrical Measurement of SOx Dew Point (SOx노점의 전기적 측정)

  • Chun, Y.N.;Yong, K.J.;Chae, J.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.600-610
    • /
    • 1995
  • When combustion gas is cooled down below the dew point of sulfuric acid vapor in the heat recovery systems, condensation occurs. Since the condensed sulfuric acid solution causes low-temperature corrosion in materials, it is important to measure the SOx dew point by electric measurement. In this study, two kinds of probes having electric gaps of 1mm or 2mm were used. and experiments were carried out by the parameters of sulfuric acid vapor and water vapor concentration. The changes of electric current caused by sulfuric acid condensed on the surface of probe according to the cooling rate and the probe head surface temperature were sudied. The opimum cooling rate was decreased with the increasing of water vaper concentration regardless of sulfuric acid concentration. The sensitivity of electric current is improved for the narrower gap(1mm) of ring electrodes, but it rarely affects the SOx dew point measuring of different probes according to the change of cooling rate.

  • PDF

Renewable Low-viscosity Dielectrics Based on Vegetable Oil Methyl Esters

  • Yu, Hui;Yu, Ping;Luo, Yunbai
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.820-829
    • /
    • 2017
  • Vegetable oil dielectrics have been used in transformers as green alternatives to mineral insulating oils for about twenty years, because of their advantages of non-toxic, biodegradability, and renewability. However, the viscosity of vegetable oils is more than 3 times of mineral oils, which means a poor heat dissipation capacity. To get low-viscosity dielectrics, transesterification and purification were performed to prepare vegetable oil methyl esters in this study. Electrical and physical properties were determined to investigate their potential as dielectrics. The results showed that the methyl ester products had good dielectric strengths, high water saturation and enough fire resistance. The viscosities (at $40^{\circ}C$) were 0.2 times less than FR3 fluid, and 0.7 times less than mineral oil, which indicated superior cooling capacity as we expected. With the assistance of 0.5 wt% pour point depressants, canola oil methyl ester exhibited the lowest pour point ($-26^{\circ}C$) among the products which was lower than FR3 fluid ($-21^{\circ}C$) and 25# mineral oil ($-23^{\circ}C$). Thus, canola oil methyl ester was the best candidate as a low-viscosity vegetable oil-based dielectric. The low-viscosity fluid could extend the service life of transformers by its better cooling capacity compared with nature ester dielectrics.

Assessment of traffic-induced low frequency sound radiated from a viaduct by field experiment

  • Kawatani, M.;Kim, C.W.;Nishitani, K.
    • Interaction and multiscale mechanics
    • /
    • v.3 no.4
    • /
    • pp.373-387
    • /
    • 2010
  • This study is intended to assess low frequency sound radiated from a viaduct under normal traffic. The bridge comprises steel box girders and wide cantilever decks on which vehicles pass. The low frequency sound and the acceleration response of the bridge under normal traffic are measured to investigate how bridge vibrations affect the low frequency sound observed near the bridge. Observations demonstrate that strong relationships exist between frequency characteristic of bridge's acceleration response and the sound pressure level of low frequency sound. A noteworthy point is that the dynamic feature of the sound pressure level is mostly affected by dynamic feature of the span locating near the observation point.

Experimental Study on Fracture Behavior of Low-Heat Concrete, by Three-Point Bent Test (3점 휨시험에의한 저발열콘크리트의 파괴거동에 곤한 실험적 연구)

  • 조병완;박승국
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.199-204
    • /
    • 1998
  • To analysis the failure character of Low-Heat concrete which is used to prevent the thermal crack caused by hydration heat, static loading test was performed by this test method, "Determination of the Fracture Energy of Motar and Concrete by Means of Three-Point Band Tests on Notched Beam" (suggested by RILEM 50-FMC Committe). This study compared and analysised the fracture energy of Mode I (opening mode), the most general pattern in the view of water-cemente ratio(W/C), compressive strength and age of Ordinary Portland Concrete and Low-Heat Concrete under the same mixture. The test results show that the case of Ordinary Portland Concrete and Low-Heat Concrete, low Water-Cemente ratio(W/C) cause the increase of fracture energy, and high failure-strength decrease failure-deflection, and the fracture energy of Low-Heat Concrete is similar to Ordinary Portland Concrete as the age increase. increase.

  • PDF

Analysis on the Mechanism of Fluting in the Bending of Low Carbon Steel Sheets (저탄소강판을 이용한 굽힘 가공에서 발생하는 꺽임현상에 대한 발생 기구 해석)

  • Park, K.C.;Yoon, J.B.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.05a
    • /
    • pp.336-339
    • /
    • 2007
  • In order to investigate the cause of fluting in tangential bending of low carbon steel sheet, an analytic analysis, an experiment and a series of finite element analysis for bending process were done. The fluting in bended sheet was due to the yield point elongation of material. Due to the yield point elongation, unstable plastic hinge was occurred in course of bending of elastic perfectly plastic sheet. According to the analysis and computational results, lower yield point elongation than 5% was required to prevent fluting in $0.5{\sim}0.6t$ sheet in $15{\sim}20mm$ radius bending.

  • PDF