• 제목/요약/키워드: Low-Energy Photon

검색결과 124건 처리시간 0.024초

The effect of photon energy on intensity-modulated radiation therapy (IMRT) plans for prostate cancer

  • Sung, Won-Mo;Park, Jong-Min;Choi, Chang-Heon;Ha, Sung-Whan;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • 제30권1호
    • /
    • pp.27-35
    • /
    • 2012
  • Purpose: To evaluate the effect of common three photon energies (6-MV, 10-MV, and 15-MV) on intensity-modulated radiation therapy (IMRT) plans to treat prostate cancer patients. Materials and Methods: Twenty patients with prostate cancer treated locally to 81.0 Gy were retrospectively studied. 6-MV, 10-MV, and 15-MV IMRT plans for each patient were generated using suitable planning objectives, dose constraints, and 8-field setting. The plans were analyzed in terms of dose-volume histogram for the target coverage, dose conformity, organs at risk (OAR) sparing, and normal tissue integral dose. Results: Regardless of the energies chosen at the plans, the target coverage, conformity, and homogeneity of the plans were similar. However, there was a significant dose increase in rectal wall and femoral heads for 6-MV compared to those for 10-MV and 15-MV. The $V_{20Gy}$ of rectal wall with 6-MV, 10-MV, and 15-MV were 95.6%, 88.4%, and 89.4% while the mean dose to femoral heads were 31.7, 25.9, and 26.3 Gy, respectively. Integral doses to the normal tissues in higher energy (10-MV and 15-MV) plans were reduced by about 7%. Overall, integral doses in mid and low dose regions in 6-MV plans were increased by up to 13%. Conclusion: In this study, 10-MV prostate IMRT plans showed better OAR sparing and less integral doses than the 6-MV. The biological and clinical significance of this finding remains to be determined afterward, considering neutron dose contribution.

Gamma radiation attenuation properties of tellurite glasses: A comparative study

  • Al-Hadeethi, Y.;Sayyed, M.I.;Tijani, S.A.
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.2005-2012
    • /
    • 2019
  • This work investigated the radiation attenuation characteristics of three series of tellurite glass systems with the following compositions: 30PbO-10ZnO-xTeO2-(60-x)B2O3 where x = 10, 30, 40, 50 and 60 mol%, xBaO-xB2O3-(100-2x)TeO2 with x = 15-40 mol% and 50ZnO-(50-x)P2O5-xTeO2, where x = 0, 10, .40 mol%. The results revealed that the attenuation parameters in all the samples decrease with increase in the energy, which implied that all the samples have better interaction with gamma photons at low energies and thus higher photon attenuating efficiency. From the three systems, the samples coded as PbZnBTe60, BaBTe70 and ZnPTe40 have the lowest half value layer values and accordingly have superior photon attenuation efficacy. The maximum effective atomic number values were found for energy less than 0.1 MeV particularly near the K-edges absorption of the heavy atomic number elements such as Te, Ba and Pb. At the lowest energy, the Zeff values are found in the range of 62.33-66.25, 49.43-50.81 and 24.99-35.83 for series 1-3 respectively. Also, we found that the density of the glass remarkably affects the photon attenuation ability of the selected glasses. The mean free path results showed that the PbO-ZnO-TeO2-B2O3 glass system has better radiation shielding efficiency than the glass samples in series 2 and 3.

A closer look at the structure and gamma-ray shielding properties of newly designed boro -tellurite glasses reinforced by bismuth (III) oxide

  • Hammam Abdurabu Thabit;Abd Khamim Ismail;N.N. Yusof;M.I. Sayyed;K.G. Mahmoud;I. Abdullahi;S. Hashim
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1734-1741
    • /
    • 2023
  • This work presents the synthesis and preparation of a new glass system described by the equation of (70-x) B2O3-5TeO2 -20SrCO3-5ZnO -xBi2O3, x = 0, 1, 5, 10, and 15 mol. %, using the melt quenching technique at a melting temperature of 1100 ℃. The photon-shielding characteristics mainly the linear attenuation coefficient (LAC) of the prepared glass samples were evaluated using Monte Carlo (MC) simulation N-particle transport code (MCNP-5) at gamma-ray energy extended from 59 keV to 1408 keV emitted by the radioisotopes Am-241, Ba-133, Cs-137, Co-60, Na-22, and Eu-152. Furthermore, we observed that the Bi2O3 content of the glasses had a significantly stronger impact on the LAC at 59 and 356 keV. The study of the lead equivalent thickness shows that the performance of fabricated glass sample with 15 mol.% of Bi2O3 is four times less than the performance of pure lead at low gamma photon energy while it is enhanced and became two times lower the perforce of pure lead at high energy. Therefore, the fabricated glasses special sample with 15 mol.% of Bi2O3 has good shielding properties in low, intermediate, and high energy intervals.

배경 잡음 제거 알고리즘을 적용한 3차원 광자 계수 집적 영상의 화질 향상 (Visual quality enhancement of three-dimensional photon-counting integral imaging using background noise removal algorithm)

  • 조기옥;김영준;김철수;조명진
    • 한국정보통신학회논문지
    • /
    • 제20권7호
    • /
    • pp.1376-1382
    • /
    • 2016
  • 본 논문에서는, 배경 잡음 제거 알고리즘을 적용하여 일반적인 3차원 광자 계수 집적 영상의 화질을 개선하는 방법을 설명한다. 광자 계수 영상법은 광자가 매우 희박한 환경에서 소수의 광자를 검출하여 영상을 시각화 하는 방법이다. 하지만, 배경에서 발생되는 광자의 수가 많을 때, 원하는 물체의 광자 검출은 매우 어렵다. 이로 인해, 복원된 영상의 화질이 저하되는 문제점이 있다. 따라서, 본 논문에서는 불필요한 배경 잡음을 제거하고 오로지 원하는 물체에서만 광자를 검출하는 새로운 광자 계수 영상법을 제안한다. 또한, 3차원 정보를 획득하기 위해 집적 영상을 사용한다. 제안된 알고리즘의 유용성을 증명하기 위하여 광학적 실험을 수행하고 성능 평가를 위해 평균 제곱 오류 값을 계산한다.

STUDY ON THE EFFECT OF THE SELF-ATTENUATION COEFFICIENT ON γ-RAY DETECTOR EFFICIENCY CALCULATED AT LOW AND HIGH ENERGY REGIONS

  • El-Khatib, Ahmed M.;Thabet, Abouzeid A.;Elzaher, Mohamed A.;Badawi, Mohamed S.;Salem, Bohaysa A.
    • Nuclear Engineering and Technology
    • /
    • 제46권2호
    • /
    • pp.217-224
    • /
    • 2014
  • The present work used the efficiency transfer method used to calculate the full energy peak efficiency (FEPE) curves of the (2"*2" & 3"*3") NaI (Tl) detectors based on the effective solid angle subtended between the source and the detector. The study covered the effect of the self attenuation coefficient of the source matrix (with a radius greater than the detector's radius) on the detector efficiency. $^{152}$ An Eu aqueous radioactive source covering the energy range from 121.78 keV up to 1408.01 keV was used. In this study an empirical formula was deduced to calculate the difference between the measured and the calculated efficiencies [without self attenuation] at low and high energy regions. A proper balance between the measured and calculated efficiencies [with self attenuation] was achieved with discrepancies less than 3%, while reaching 39% for calculating values [without self attenuation] due to working with large sources, or for low photon energies.

Calculation of X-ray attenuation coefficients for normal and cancerous breast tissues

  • Aysun Boke
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.241-246
    • /
    • 2024
  • The study was carried out by numerical integration based on the diffraction properties and elemental composition. The elemental compositions of breast tissues in the literature were tested. The photon attenuation coefficients calculated using the recent elemental composition were found within 0.2-16% for adipose tissue and within 0.04-17% for glandular tissue with the experimental reference data. The attenuation coefficients of cancerous breast tissue calculated according to the elemental content previously measured in breast cancer patients were found within 0-17% with experimental data in the literature. The attenuation coefficients are of great interest to medical research. To calculate realistic attenuation coefficients, the characteristic coherent scatter, which is most intense at small angles, must be considered. For this reason, experimentally measured form factor data were reviewed, and the most compatible one with the theoretical form factor data produced in this study was used at low momentum transfer x (0 < x ≤ 8 nm-1). The differential linear coherent scattering distributions were calculated for an energy value of 17.44 keV and compared with their experimental counterparts.

RF Sputtering 으로 제작한 SrTiO$_3$ 박막 특성에 미치는 Ti 중간층의 영향 (A Study on the Effects of Ti interlayer on the Properties of RF Sputtering SrTiO$_3$ Thin Films)

  • 정천옥;김병인;이정재;김창석;송철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.8-11
    • /
    • 1997
  • This study makes SrTiO$_{3}$ with nonpolarity among ferroelectrics by RF sputtering as dielectric layer, produces thin film of Si/SrTiO$_{3}$ and Si/Ti/SrTiO$_{3}$ of MOS structure using Ti as buffer layer, measures and examines the electrical features with optical refractive index, absorption rate, permittivity, photon energy and as a result, ferroelectrics oscillation occurrs by the interaction within a film by light temperature and the absorption of thin film with Ti as buffer layer is increased. It is found that the pea\ulcorner of permittivity value of Ti/SrTiO$_{3}$ thin film has low values and is appeared late and as dipole which is found in dielectric is shown, the experiment satisfies the theory In the nature of permittivity by photon energy, imaginary value is higher and current variation slope of thin film of thickness SrTiO$_{3}$ has lower values in reverse bias.

  • PDF

Acclimation of maximum quantum yield of PSII and photosynthetic pigments of Panax quinquefolius L. to understory light

  • Fournier, Anick R.;T.A., John;Khanizadeh, Shahrokh;Gosselin, Andre;Dorais, Martine
    • Journal of Ginseng Research
    • /
    • 제32권4호
    • /
    • pp.347-356
    • /
    • 2008
  • Forest-grown American ginseng (Panax quinquefolius L.) is exposed to daily and seasonal light variations. Our goal was to determine the effect of understory light changes on the maximum quantum yield of photosystem II, expressed as $F_v/F_m$, and photosynthetic pigment composition of two-year-old plants. Understory light photon flux density and sunfleck durations were characterized using hemispherical canopy photography. Our results showed that understory light significantly affected the $F_v/F_m$ of American ginseng, especially during the initial development of the plants when light levels were the highest, averaging 28 mol $m^{-2}d^{-1}$. Associated with low $F_v/F_m$ during its initial development, American ginseng had the lowest levels of epoxidation state of the xanthophyll cycle of the season, suggesting an active dissipation of excess light energy absorbed by the chlorophyll pigments. As photon flux density decreased after the deployment of the forest canopy to less than 10 mol $m^{-2}d^{-1}$, chlorophyll a/b decreased suggesting a greater investment in light harvesting pigments to reaction centers in order to absorb the fleeting light energy.

Physical and Microbiological Approach in Proving the Identity of Gamma-irradiated Different Teas

  • Kausar, Tusneem;Kim, Byeong-Keun;Kim, Dong-Ho;Kwon, Joong-Ho
    • Food Science and Biotechnology
    • /
    • 제14권1호
    • /
    • pp.1-5
    • /
    • 2005
  • Photostimulated luminescence (PSL), thermoluminescence (TL), electron spin resonance (ESR), and direct epiflourescent filter technique/aerobic plate count (DEFT/APC) were applied to detect dried green, black, and oolong teas irradiated between 0-10 kGy. Teas irradiated at 2.5 kGy and higher showed over 5000 photon counts/60 sec, while non-irradiated teas yielded 650-1000 photon counts/60 sec. TL glow curves for minerals separated from teas were detected at about $300^{\circ}C$ with low intensity in non-irradiated samples, whereas around $150^{\circ}C$ with high intensity in all irradiated samples. Ratio of $TL_1/TL_2$ based on re-irradiation step, showing lower than 0.1 and higher than 1.44 for non-irradiated and irradiated samples, respectively, enhanced reliability of TL results. ESR measurements for irradiated teas showed signals specific to irradiation. Log DEFT/APC ratio increased with irradiation dose; this result could be applied to identify irradiated tea samples.

역광전자분광기의 제작 및 그 응용 (Construction of Inverse Photoemission Spectrometer and Its Application)

  • 김정원;김세훈
    • 대한화학회지
    • /
    • 제40권12호
    • /
    • pp.719-723
    • /
    • 1996
  • 고체표면의 비점유 전자에너지 상태를 연구하고자 역광전자분광기를 제작하고 시험하였다. 이 분광기는 초고진공 챔버속에 전자총과 광검출기로 구성되어 있다. 전자총은 궤도 시뮬레이션과 전류 측정을 통해 좋은 집속도와 높은 전류밀도를 가지고 있음을 알 수 있었다. 이 분광기의 전체적인 분해능은 0.74 eV이고, 광검출기의 감도는 약 10 counts/$sec{\cdot}{\mu}A$이다. 하나의 결과로서 Ge(111) 시료의 역광전자분광 스펙트럼은 이론적인 계산결과와 잘 일치하였다.

  • PDF